Submittal Log
| Activity Number | Transmittal Number | Section Number | SD Number | Submittal Item | Subpart Number | Submittal Classification | Reviewer | UNUSED | UNUSED |
| 01 33 00 | SD-01 | Submittal schedule | 3.3.1 | G | |||||
| 01 33 00 | SD-01 | List of proposed subcontractors | G | ||||||
| 01 33 00 | SD-01 | Construction Progress Schedule | |||||||
| 01 33 00 | SD-01 | Health and Safety Plan | |||||||
| 01 33 00 | SD-01 | Work Plan | |||||||
| 01 35 26 | SD-01 | Accident Prevention Plan (APP) | 1.7 | G | |||||
| 01 35 26 | SD-01 | Activity Hazard Analysis (AHA) | 1.8 | G | |||||
| 01 35 26 | SD-01 | Crane Critical Lift Plan | 1.7.1 | G | |||||
| 01 35 26 | SD-01 | Crane Operators | 1.6.1.2 | ||||||
| 01 35 26 | SD-06 | Reports | 1.12 | ||||||
| 01 35 26 | SD-06 | Accident Reports | 1.12.1 | ||||||
| 01 35 26 | SD-06 | Crane Reports | 1.12.3 | ||||||
| 01 35 26 | SD-07 | Hot work permit | |||||||
| 01 35 26 | SD-07 | Contractor Safety Self-Evaluation Checklist | 1.4 | G | |||||
| 01 35 26 | SD-07 | Certificate of Compliance | 1.12.4 | ||||||
| 01 45 01 | SD-18 | QC Plan | 2.2 | G | |||||
| 01 50 00 | SD-1 | Construction Site Plan | 1.4 | ||||||
| 01 50 00 | SD-1 | Traffic Control | 3.3 | ||||||
| 01 57 20.00 10 | SD-01 | Environmental Protection Plan | 1.8 | G | |||||
| 01 70 00 | SD-01 | Spare Parts, Special Tools | 2.1 | G | |||||
| 01 70 00 | SD-04 | As-Builts | 2.2 | G | |||||
| 01 70 00 | SD-13 | Warranty | 2.3 | G | |||||
| 01 70 00 | SD-19 | Warranty Labels | 3.1 | G | |||||
| 01 73 00 | SD-07 | Qualification Data | 1.3 | ||||||
| 01 78 00 | SD-03 | As-Built Record of Equipment and Materials | 1.3.2 | ||||||
| 01 78 00 | SD-03 | Warranty Management Plan | 1.7.1 | ||||||
| 01 78 00 | SD-03 | Warranty Tags | 1.7.5 | ||||||
| 01 78 00 | SD-03 | Final Cleaning | |||||||
| 01 78 00 | SD-03 | Spare Parts Data | 1.4 | ||||||
| 01 78 00 | SD-08 | Preventative Maintenance | 1.5 | ||||||
| 01 78 00 | SD-08 | Condition Monitoring (Predictive Testing) | 1.5 | ||||||
| 01 78 00 | SD-08 | Inspection | 1.5 | ||||||
| 01 78 00 | SD-08 | Instructions | 1.7.1 | ||||||
| 01 78 00 | SD-10 | Operation and Maintenance Manuals | 1.9 | ||||||
| 01 78 00 | SD-11 | Record Drawings | 1.3.1 | ||||||
| 01 78 00 | SD-11 | Certification of EPA Designated Items | 1.6 | G | |||||
| 01 78 00 | SD-11 | Form DD1354 | 1.11 | G | |||||
| 01 78 00 | SD-11 | Checklist for Form DD1354 | 1.11 | G | |||||
| 02 41 00 | SD-01 | Existing Conditions | 1.6.2 | G | |||||
| 02 41 00 | SD-02 | Details and Engineering Calculations | 1.14.11 | G | |||||
| 02 41 00 | SD-07 | Demolition Plan | 1.1 | G | |||||
| 02 41 00 | SD-07 | Notifications | 1.4.1 | G | |||||
| 02 41 00 | SD-11 | Receipts | 1.4.2 | ||||||
| 02 81 00 | SD-03 | On-site Hazardous Waste Management | 3.1 | G | |||||
| 02 81 00 | SD-03 | Notices of Non-Compliance and Notices of Violation | 3.2 | ||||||
| 02 81 00 | SD-06 | Recordkeeping | 3.7 | G | |||||
| 02 81 00 | SD-06 | Spill Response | 3.8 | ||||||
| 02 81 00 | SD-06 | Exception Reports | 3.7 | G | |||||
| 02 81 00 | SD-06 | Packaging Notifications | 2.1.1 | ||||||
| 02 81 00 | SD-07 | Certification | 1.4.3 | ||||||
| 02 81 00 | SD-07 | Security Plan | 3.2.4 | ||||||
| 02 81 00 | SD-07 | Transportation and Disposal Coordinator | 1.4.1 | ||||||
| 02 81 00 | SD-07 | Training | 1.4.2 | ||||||
| 02 81 00 | SD-07 | EPA Off-Site Policy | 3.2.2 | ||||||
| 02 81 00 | SD-07 | Certificates of Disposal | 3.2.5 | ||||||
| 02 81 00 | SD-07 | Shipping Documents and Packagings Certification | 3.2.3 | ||||||
| 02 81 00 | SD-07 | Waste Minimization | 3.6 | ||||||
| 02 82 14.00 10 | SD-02 | Detailed Drawings | 1.4 | G | |||||
| 02 82 14.00 10 | SD-03 | Asbestos Waste Shipment Records | 3.11.5.1 | G | |||||
| 02 82 14.00 10 | SD-03 | Weight Bills and Delivery Tickets | 3.11.4 | G | |||||
| 02 82 14.00 10 | SD-03 | Encapsulants | 2.1 | G | |||||
| 02 82 14.00 10 | SD-03 | Respiratory Protection Program | 1.12 | G | |||||
| 02 82 14.00 10 | SD-03 | Cleanup and Disposal | 3.11 | G | |||||
| 02 82 14.00 10 | SD-03 | Qualifications | 1.5 | G | |||||
| 02 82 14.00 10 | SD-03 | Training Program | 1.11 | ||||||
| 02 82 14.00 10 | SD-03 | Licenses, Permits and Notifications | 1.13 | G | |||||
| 02 82 14.00 10 | SD-06 | Exposure Assessment and Air Monitoring | 3.9 | G | |||||
| 02 82 14.00 10 | SD-06 | Local Exhaust System | 1.19 | ||||||
| 02 82 14.00 10 | SD-07 | Local Exhaust System | 1.19 | ||||||
| 02 82 14.00 10 | SD-07 | Encapsulants | 2.1 | G | |||||
| 02 82 14.00 10 | SD-07 | Medical Surveillance Requirements | 1.1 | ||||||
| 02 82 16.00 20 | SD-03 | Local exhaust equipment | 3.1.4 | G | |||||
| 02 82 16.00 20 | SD-03 | Vacuums | 3.1.5 | G | |||||
| 02 82 16.00 20 | SD-03 | Respirators | 3.1.1.1 | G | |||||
| 02 82 16.00 20 | SD-03 | Pressure differential automatic recording instrument | 3.1.4 | G | |||||
| 02 82 16.00 20 | SD-03 | Amended water | 1.2.2 | G | |||||
| 02 82 16.00 20 | SD-03 | Glovebags | 3.1.7 | G | |||||
| 02 82 16.00 20 | SD-03 | Material Safety Data Sheets (MSDS) for all materials | 1.3.8 | G | |||||
| 02 82 16.00 20 | SD-03 | Encapsulants | 2.1 | G | |||||
| 02 82 16.00 20 | SD-06 | Air sampling results | 1.5.5 | G | |||||
| 02 82 16.00 20 | SD-06 | Pressure differential recordings for local exhaust system | 1.5.6 | G | |||||
| 02 82 16.00 20 | SD-06 | Asbestos disposal quantity report | 3.3.3.2 | G | |||||
| 02 82 16.00 20 | SD-06 | Encapsulation test patches | 3.2.6.2 | G | |||||
| 02 82 16.00 20 | SD-06 | Clearance sampling | 3.2.7.3 | G | |||||
| 02 82 16.00 20 | SD-07 | Asbestos hazard abatement plan | 1.3.9 | G | |||||
| 02 82 16.00 20 | SD-07 | Testing laboratory | 1.3.10 | G | |||||
| 02 82 16.00 20 | SD-07 | Competent person documentation | 1.5.1 | G | |||||
| 02 82 16.00 20 | SD-07 | Contractor's license | 1.5.4 | G | |||||
| 02 82 16.00 20 | SD-07 | Competent person | 1.5.2 | G | |||||
| 02 82 16.00 20 | SD-07 | Worker's license | 1.5.3 | G | |||||
| 02 82 16.00 20 | SD-07 | Landfill approval | 1.3.11 | G | |||||
| 02 82 16.00 20 | SD-07 | Employee training | 1.3.3 | G | |||||
| 02 82 16.00 20 | SD-07 | Medical certification | 1.3.12 | G | |||||
| 02 82 16.00 20 | SD-07 | Waste shipment records | 1.3.11 | G | |||||
| 02 82 16.00 20 | SD-07 | Respiratory Protection Program | 1.3.6 | G | |||||
| 02 82 16.00 20 | SD-07 | Delivery tickets | 1.3.11 | G | |||||
| 02 82 16.00 20 | SD-07 | Vacuums | 3.1.5 | G | |||||
| 02 82 16.00 20 | SD-07 | Water filtration equipment | 3.1.2.3 | G | |||||
| 02 82 16.00 20 | SD-07 | Ventilation systems | 3.1.5 | G | |||||
| 02 82 16.00 20 | SD-07 | equipment used to contain airborne asbestos fibers | 3.1 | G | |||||
| 02 82 16.00 20 | SD-07 | encapsulants | 2.1 | G | |||||
| 02 82 16.00 20 | SD-07 | Notifications | 1.3.4 | ||||||
| 02 82 16.00 20 | SD-11 | Notifications | 1.3.4 | G | |||||
| 02 82 16.00 20 | SD-11 | Rental equipment | 1.6.1 | G | |||||
| 02 82 16.00 20 | SD-11 | Respirator program records | 1.3.6.1 | G | |||||
| 02 82 16.00 20 | SD-11 | Permits and licenses | 1.3.4 | G | |||||
| 02 83 13.00 20 | SD-01 | Lead Compliance Plan | 1.5.2.2 | G | |||||
| 02 83 13.00 20 | SD-01 | Competent Person | 1.5.1.1 | ||||||
| 02 83 13.00 20 | SD-01 | Training Certification | 1.5.1.2 | ||||||
| 02 83 13.00 20 | SD-01 | Lead waste management plan | 1.5.2.8 | G | |||||
| 02 83 13.00 20 | SD-01 | Written evidence | 3.5.2.1 | ||||||
| 02 83 13.00 20 | SD-01 | Medical Examinations | 1.5.2.4 | ||||||
| 02 83 13.00 20 | SD-06 | Sampling results | 1.5.2.3 | ||||||
| 02 83 13.00 20 | SD-06 | Occupational and Environmental Assessment Data Report | 1.5.2.3 | G | |||||
| 02 83 13.00 20 | SD-07 | Testing laboratory | 1.5.1.3 | ||||||
| 02 83 13.00 20 | SD-07 | Occupant Notification | 3.1.1.1 | ||||||
| 02 83 13.00 20 | SD-07 | Third party consultant qualifications | 1.5.1.4 | ||||||
| 02 83 13.00 20 | SD-07 | Clearance Certification | 3.5.1.1 | ||||||
| 02 83 13.00 20 | SD-11 | hazardous waste manifest | 3.5.2.1 | G | |||||
| 02 84 33 | SD-07 | Training certification | 1.7.1 | ||||||
| 02 84 33 | SD-07 | Qualifications of CIH | 1.7.2 | ||||||
| 02 84 33 | SD-07 | PCB removal work plan | 1.7.3 | ||||||
| 02 84 33 | SD-07 | PCB disposal plan | 1.7.4 | ||||||
| 02 84 33 | SD-07 | Notification | 1.7.5 | ||||||
| 02 84 33 | SD-07 | Transporter certification | 3.8 | ||||||
| 02 84 33 | SD-07 | Certification of Decontamination | 3.5.4 | ||||||
| 02 84 33 | SD-07 | Post cleanup sampling | 3.5.5 | ||||||
| 02 84 33 | SD-07 | Certificate of disposal | 3.8.1 | ||||||
| 05 30 00 | SD-02 | Fabrication Drawings | 1.3.5 | G | |||||
| 05 30 00 | SD-02 | Cant Strips | 2.3.1.1 | G | |||||
| 05 30 00 | SD-02 | Ridge and Valley Plates | 2.3.1.2 | G | |||||
| 05 30 00 | SD-02 | Metal Closure Strips | 2.3.1.3 | G | |||||
| 05 30 00 | SD-03 | Accessories | 2.2 | ||||||
| 05 30 00 | SD-03 | Galvanizing Repair Paint | 2.1.5 | ||||||
| 05 30 00 | SD-03 | Joint Sealant Material | 2.1.4 | G | |||||
| 05 30 00 | SD-03 | Mechanical Fasteners | 2.2.12 | G | |||||
| 05 30 00 | SD-03 | Piston Tool Operator | 1.3.2 | ||||||
| 05 30 00 | SD-03 | Repair Paint | 2.3.7 | ||||||
| 05 30 00 | SD-03 | Sound Absorbing Material | 2.1.7 | G | |||||
| 05 30 00 | SD-03 | Welder Qualifications | 1.3.3 | ||||||
| 05 30 00 | SD-03 | Welding Equipment | 1.3.3 | ||||||
| 05 30 00 | SD-03 | Welding Rods and Accessories | 1.3.3 | G | |||||
| 05 30 00 | SD-04 | Metal Roof Deck Units | 2.3 | G | |||||
| 05 30 00 | SD-04 | Flexible Closure Strips | 2.1.6 | G | |||||
| 05 30 00 | SD-04 | Flexible Closure Strips | 2.3 | G | |||||
| 05 30 00 | SD-04 | Accessories | 2.2 | G | |||||
| 05 30 00 | SD-05 | Deck units | 2.3 | G | |||||
| 05 30 00 | SD-07 | Decking Material | 1.3.1 | G | |||||
| 05 30 00 | SD-07 | Welding Procedures | 1.3.3 | ||||||
| 05 30 00 | SD-07 | Fire Safety | 1.3.4.1 | ||||||
| 05 30 00 | SD-07 | Wind Storm Resistance | 1.3.4.2 | ||||||
| 05 50 13 | SD-02 | Expansion joint covers | 2.4 | G | |||||
| 05 50 13 | SD-02 | Roof walkways | 2.5 | G | |||||
| 05 50 13 | SD-02 | Roof hatch | 3.7 | G | |||||
| 05 50 13 | SD-03 | Expansion joint covers | 2.4 | G | |||||
| 05 50 13 | SD-03 | Roof walkways | 2.5 | ||||||
| 05 50 13 | SD-03 | Roof hatch | 3.7 | G | |||||
| 05 50 13 | SD-04 | Expansion joint covers | 2.4 | ||||||
| 05 50 13 | SD-04 | Roof hatch | 2.5 | ||||||
| 05 50 13 | SD-11 | Roof hatch | 1.4 | G | |||||
| 05 51 33 | SD-02 | Ladders | 2.3 | G | |||||
| 05 51 33 | SD-03 | Ladders | 2.3 | G | |||||
| 05 52 00 | SD-02 | Steel Railings and Handrails | 2.9 | G | |||||
| 05 52 00 | SD-02 | Aluminum Railings and Handrails | 2.1 | G | |||||
| 05 52 00 | SD-02 | Steel Stair System | 2.12 | G | |||||
| 05 52 00 | SD-03 | Structural Steel Plates, Shapes, and Bars | 2.2 | G | |||||
| 05 52 00 | SD-03 | Concrete Inserts | 2.4 | G | |||||
| 05 52 00 | SD-03 | Masonry Anchorage Devices | 2.5 | G | |||||
| 05 52 00 | SD-03 | Protective Coatings | 2.8 | G | |||||
| 05 52 00 | SD-03 | Steel Railings and Handrails | 2.9 | G | |||||
| 05 52 00 | SD-03 | Aluminum Railings and Handrails | 2.1 | G | |||||
| 05 52 00 | SD-03 | Steel Stair System | 2.12 | G | |||||
| 05 52 00 | SD-03 | Structural Steel Plates, Shapes, and Bars | 2.2 | ||||||
| 05 52 00 | SD-03 | Concrete Inserts | 2.8 | G | |||||
| 05 52 00 | SD-03 | Masonry Anchorage Devices | 2.9 | G | |||||
| 05 52 00 | SD-03 | Steel Railings and Handrails | 2.13 | G | |||||
| 05 52 00 | SD-03 | Aluminum Railings and Handrails | 2.14 | G | |||||
| 05 52 00 | SD-03 | Steel Stair System | 2.11 | G | |||||
| 05 52 00 | SD-07 | Welding Procedures | 1.3 | ||||||
| 05 52 00 | SD-07 | Welder Qualification | 1.3 | ||||||
| 05 52 00 | SD-08 | Steel Railings and Handrails | 2.9 | G | |||||
| 05 52 00 | SD-08 | Aluminum Railings and Handrails | 2.1 | G | |||||
| 06 10 00 | SD-02 | Nailing Strips | 2.5.4.1 | G | |||||
| 06 10 00 | SD-03 | Underlayment | 2.4 | G | |||||
| 06 10 00 | SD-03 | Plastic Lumber | 2.1.2 | G | |||||
| 06 10 00 | SD-03 | Fire-retardant treatment | 1.8 | G | |||||
| 06 10 00 | SD-03 | Engineered wood products | 2.1.1 | G | |||||
| 06 10 00 | SD-03 | Structural-use and OSB panels | 1.4.3 | G | |||||
| 06 10 00 | SD-03 | Oriented Strand Board | 2.3 | G | |||||
| 06 10 00 | SD-03 | Adhesives | 2.5.5 | G | |||||
| 06 10 00 | SD-03 | Qualifications | 3.1 | ||||||
| 06 10 00 | SD-05 | Modifications of structural members | 1.9.2 | G | |||||
| 06 10 00 | SD-06 | Preservative-treated | 1.4.4 | ||||||
| 06 10 00 | SD-07 | Certificates of grade | 1.9.3 | ||||||
| 06 10 00 | SD-07 | Preservative treatment | 1.7 | ||||||
| 06 10 00 | SD-10 | Take-back program | 3.4 | ||||||
| 07 21 13 | SD-03 | Block or board insulation | 2.1 | G | |||||
| 07 21 13 | SD-03 | Vapor barrier | 2.2 | G | |||||
| 07 21 13 | SD-03 | Pressure sensitive tape | 2.3 | G | |||||
| 07 21 13 | SD-03 | Protection board or coating | 2.4 | G | |||||
| 07 21 13 | SD-03 | Accessories | 2.5 | G | |||||
| 07 21 13 | SD-08 | Block or Board Insulation | 2.1 | ||||||
| 07 21 13 | SD-08 | Adhesive | 2.5.1 | ||||||
| 07 22 00 | SD-02 | Roof Plan | 2.1.5 | G | |||||
| 07 22 00 | SD-02 | Wood nailers | 2.7 | ||||||
| 07 22 00 | SD-02 | Tapered roof insulation | 2.1.5 | G | |||||
| 07 22 00 | SD-02 | Tapered cants and crickets | 2.1.6 | G | |||||
| 07 22 00 | SD-03 | Fasteners | 2.6 | G | |||||
| 07 22 00 | SD-03 | Insulation | 2.1 | G | |||||
| 07 22 00 | SD-06 | Flame spread and smoke developed ratings | 1.4.1 | ||||||
| 07 22 00 | SD-07 | qualifications | 1.3 | ||||||
| 07 22 00 | SD-08 | fasteners | 2.6 | ||||||
| 07 22 00 | SD-08 | insulation | 2.1 | ||||||
| 07 31 13 | SD-03 | Shingles | 2.1.1 | G | |||||
| 07 31 13 | SD-04 | Shingles | 2.1.1 | G | |||||
| 07 31 13 | SD-04 | Color charts | 2.1.1 | G | |||||
| 07 31 13 | SD-08 | Application | 3.3 | ||||||
| 07 32 14 | SD-02 | Clay Tile Roofing Systems | 1.3 | G | |||||
| 07 32 14 | SD-03 | Clay Tile Roofing Systems | 1.3 | G | |||||
| 07 32 14 | SD-03 | Qualifications | 1.3 | ||||||
| 07 32 14 | SD-04 | Clay Roofing Tile | 2.1.2 | G | |||||
| 07 32 14 | SD-04 | Sealant | 2.1.7 | ||||||
| 07 32 14 | SD-04 | Underlayment Membrane | 2.1.3 | G | |||||
| 07 32 14 | SD-04 | Fasteners | 2.1.4 | G | |||||
| 07 32 14 | SD-07 | Materials | 2.1 | ||||||
| 07 32 14 | SD-07 | Warranty | 1.6 | G | |||||
| 07 41 13 | SD-02 | Roofing Panels | 1.4.5 | G | |||||
| 07 41 13 | SD-02 | Flashing and Accessories | 1.4.5 | G | |||||
| 07 41 13 | SD-02 | Gutter/Downspout Assembly | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Roof panels | 2.1 | G | |||||
| 07 41 13 | SD-03 | FACTORY-APPLIED COLOR FINISH | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Accessories | 2.4 | G | |||||
| 07 41 13 | SD-03 | Fasteners | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Pressure Sensitive Tape | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | UNDERLAYMENTS | 2.7 | G | |||||
| 07 41 13 | SD-03 | Gaskets and Sealing/Insulating Compounds | 2.8 | G | |||||
| 07 41 13 | SD-03 | Coil Stock | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Aluminized Steel Repair Paint | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Enamel Repair Paint | 1.4.5 | G | |||||
| 07 41 13 | SD-03 | Galvanizing Repair Paint | 1.4.5 | G | |||||
| 07 41 13 | SD-04 | Roof Panels | 2.1 | G | |||||
| 07 41 13 | SD-04 | Sealants | 2.5 | G | |||||
| 07 41 13 | SD-04 | Factory-applied Color Finish | 1.4.5 | G | |||||
| 07 41 13 | SD-04 | Accessories | 2.4 | G | |||||
| 07 41 13 | SD-04 | Fasteners | 1.4.5 | ||||||
| 07 41 13 | SD-04 | Gaskets and Sealant/Insulating Compounds | 1.4.5 | ||||||
| 07 41 13 | SD-05 | Wind Uplift Resistance | 1.2.1.2 | G | |||||
| 07 41 13 | SD-06 | Leakage Test Report | 1.2.1.1 | ||||||
| 07 41 13 | SD-06 | Wind Uplift Test Report | 1.2.1.2 | ||||||
| 07 41 13 | SD-06 | Fire Rating Test Report | 2.6.2 | ||||||
| 07 41 13 | SD-06 | Factory Finish and Color Performance Requirements | 2.2 | ||||||
| 07 41 13 | SD-07 | Roof Panels | 2.1 | G | |||||
| 07 41 13 | SD-07 | Coil stock compatibility | 1.4.5 | ||||||
| 07 41 13 | SD-07 | Self-Adhering Modified Bitumen Underlayment | 2.7.1 | ||||||
| 07 41 13 | SD-07 | Qualification of Manufacturer | 1.4.1 | ||||||
| 07 41 13 | SD-07 | Qualification of Applicator | 1.4.2 | ||||||
| 07 41 13 | SD-08 | Insulation | 2.6 | ||||||
| 07 41 13 | SD-08 | INSTALLATION MANUAL | 1.4.5 | ||||||
| 07 41 13 | SD-09 | Manufacturer's Field Inspection Reports | 3.10.1 | ||||||
| 07 41 13 | SD-11 | Warranties | 1.8 | G | |||||
| 07 41 13 | SD-11 | Information Card | 3.11 | G | |||||
| 07 41 13 | SD-11 | Date Of Installation Wall-Mounted Placard | 3.12 | G | |||||
| 07 51 13 | SD-03 | wind uplift calculations | 1.4.3 | G | |||||
| 07 51 13 | SD-03 | Asphalt | 2.4 | ||||||
| 07 51 13 | SD-03 | Felts | 3.3.4 | G | |||||
| 07 51 13 | SD-03 | Granule Surface Modified Bitumen Cap Sheet | 2.5.2 | G | |||||
| 07 51 13 | SD-03 | FLASHING MEMBRANE | 2.3 | G | |||||
| 07 51 13 | SD-03 | Fasteners | 2.1 | G | |||||
| 07 51 13 | SD-03 | Primer | 2.6 | G | |||||
| 07 51 13 | SD-03 | Asphalt Roof Cement | 2.7 | G | |||||
| 07 51 13 | SD-03 | Walkpad Materials | 2.12 | G | |||||
| 07 51 13 | SD-03 | Cant Strips | 2.8 | G | |||||
| 07 51 13 | SD-03 | Pre-Manufactured Accessories | 2.11 | G | |||||
| 07 51 13 | SD-03 | Roof Walkways | 2.12.1 | ||||||
| 07 51 13 | SD-03 | warranties | 1.8 | G | |||||
| 07 51 13 | SD-06 | Samples of Built-Up Roofing | 3.5.3 | ||||||
| 07 51 13 | SD-07 | bill of lading | 1.5.1 | ||||||
| 07 51 13 | SD-07 | Qualifications of Applicator | 1.4.1 | ||||||
| 07 51 13 | SD-08 | felts | 3.3.4 | ||||||
| 07 51 13 | SD-08 | flashings | 3.5.2 | ||||||
| 07 51 13 | SD-08 | modified bitumen cap sheet | 3.4.5 | ||||||
| 07 51 13 | SD-08 | Asphalt | 2.4 | ||||||
| 07 51 13 | SD-08 | Primer | 2.6 | ||||||
| 07 51 13 | SD-08 | asphalt roof cement | 2.7 | ||||||
| 07 51 13 | SD-08 | Fasteners | 2.1 | ||||||
| 07 51 13 | SD-08 | Cold weather condition installation | 1.6 | G | |||||
| 07 51 13 | SD-11 | WARRANTY | 1.8 | G | |||||
| 07 51 13 | SD-11 | INFORMATION CARD | 3.7 | G | |||||
| 07 54 19 | SD-02 | Detail Drawings | 1.8.4 | G | |||||
| 07 54 19 | SD-03 | PVC Roofing Membrane | 3.2.2 | G | |||||
| 07 54 19 | SD-03 | Bonding Adhesive | 2.1.1 | G | |||||
| 07 54 19 | SD-03 | Flashing | 3.2.2.2 | G | |||||
| 07 54 19 | SD-03 | Membrane Fasteners and Plates | 2.1.4 | G | |||||
| 07 54 19 | SD-03 | Roof Insulation | 2.1.8 | G | |||||
| 07 54 19 | SD-03 | Pre-manufactured accessories | 2.1.5 | G | |||||
| 07 54 19 | SD-03 | Water Cutoffs | 3.3.1 | ||||||
| 07 54 19 | SD-03 | Information Card | 2.1 | G | |||||
| 07 54 19 | SD-05 | Wind uplift calculations | 1.2.3 | G | |||||
| 07 54 19 | SD-07 | Qualification of ENERGY STAR-labeled PVC | 1.4.1 | G | |||||
| 07 54 19 | SD-07 | Qualifications of Applicator | 1.4.2 | G | |||||
| 07 54 19 | SD-07 | Wind Uplift Resistance | 1.2.3 | G | |||||
| 07 54 19 | SD-07 | Fire Resistance | 1.2.2 | G | |||||
| 07 54 19 | SD-07 | Minimum Polymer Thickness | 2.1.3 | G | |||||
| 07 54 19 | SD-07 | Warranty | 1.8 | G | |||||
| 07 54 19 | SD-08 | Application Method | 3.2 | G | |||||
| 07 54 19 | SD-08 | Membrane Flashing | 2.1.3 | G | |||||
| 07 54 19 | SD-08 | Perimeter Attachment | 3.2.5 | ||||||
| 07 54 19 | SD-08 | Auxiliary Fasteners | 2.1.4.2 | ||||||
| 07 54 19 | SD-08 | Pre-manufactured accessories | 2.1.5 | ||||||
| 07 54 19 | SD-08 | Cold weather | 1.5.2 | G | |||||
| 07 54 19 | SD-10 | Instructions to Government Personnel | 3.5 | ||||||
| 07 60 00 | SD-02 | Covering on flat, sloped, or curved surfaces | 3.1.26 | G | |||||
| 07 60 00 | SD-02 | Gutters | 3.1.17 | G | |||||
| 07 60 00 | SD-02 | Leaf Guards | 3.1.18 | G | |||||
| 07 60 00 | SD-02 | Downspouts | 3.1.19 | G | |||||
| 07 60 00 | SD-02 | Expansion joints | 3.1.27 | G | |||||
| 07 60 00 | SD-02 | Gravel stops and fascias | 3.1.15 | G | |||||
| 07 60 00 | SD-02 | Splash pans | 3.1.23 | G | |||||
| 07 60 00 | SD-02 | Flashing for roof drains | 3.1.20 | G | |||||
| 07 60 00 | SD-02 | Base flashing | 3.1.11 | G | |||||
| 07 60 00 | SD-02 | Counterflashing | 3.1.12 | G | |||||
| 07 60 00 | SD-02 | Flashing at roof penetrations | 3.1.28 | G | |||||
| 07 60 00 | SD-02 | Reglets | 3.1.13 | G | |||||
| 07 60 00 | SD-02 | Scuppers | 3.1.21 | G | |||||
| 07 60 00 | SD-02 | Copings | 3.1.31 | G | |||||
| 07 60 00 | SD-02 | Drip edge | 3.1.16 | G | |||||
| 07 60 00 | SD-02 | Conductor heads | 3.1.22 | ||||||
| 07 60 00 | SD-02 | Open valley flashing | 3.1.24 | G | |||||
| 07 60 00 | SD-02 | Eave flashing | 3.1.25 | G | |||||
| 07 60 00 | SD-11 | Quality Control Plan | 3.5 | ||||||
| 07 61 15.00 20 | SD-02 | Roofing panels | 2.1 | G | |||||
| 07 61 15.00 20 | SD-03 | Roofing panels | 2.1 | G | |||||
| 07 61 15.00 20 | SD-03 | Attachment clips | 2.2 | ||||||
| 07 61 15.00 20 | SD-03 | Closures | 2.3.1 | ||||||
| 07 61 15.00 20 | SD-03 | Accessories | 2.3 | ||||||
| 07 61 15.00 20 | SD-03 | Underlayment | 2.5 | ||||||
| 07 61 15.00 20 | SD-03 | Fasteners | 2.3.2 | ||||||
| 07 61 15.00 20 | SD-03 | Sealant | 2.3.3 | ||||||
| 07 61 15.00 20 | SD-03 | Insulation | 2.4 | ||||||
| 07 61 15.00 20 | SD-03 | warranty | 1.8 | G | |||||
| 07 61 15.00 20 | SD-04 | Roofing panels | 2.1 | ||||||
| 07 61 15.00 20 | SD-04 | Accessories | 2.3 | ||||||
| 07 61 15.00 20 | SD-04 | Sealant | 2.3.3 | ||||||
| 07 61 15.00 20 | SD-04 | Intermediate Support Section | 1.5 | ||||||
| 07 61 15.00 20 | SD-05 | Design calculations | 1.5 | G | |||||
| 07 61 15.00 20 | SD-06 | Structural performance | 1.3.2.6 | G | |||||
| 07 61 15.00 20 | SD-06 | Panel finish | 2.6 | G | |||||
| 07 61 15.00 20 | SD-06 | Manufacturer's field inspection | 3.6 | G | |||||
| 07 61 15.00 20 | SD-07 | Technical representative | 1.6.2 | ||||||
| 07 61 15.00 20 | SD-07 | Qualification of Installer | 1.6.3 | ||||||
| 07 61 15.00 20 | SD-07 | Coil stock | 2.1 | G | |||||
| 07 61 15.00 20 | SD-08 | Sealant | 2.3.3 | ||||||
| 07 61 15.00 20 | SD-08 | Installation | 3.3 | G | |||||
| 07 61 15.00 20 | SD-11 | Information card | 3.8 | ||||||
| 07 92 00 | SD-03 | Sealants | 2.1 | G | |||||
| 07 92 00 | SD-03 | Primers | 2.2 | G | |||||
| 07 92 00 | SD-03 | Bond breakers | 2.3 | G | |||||
| 07 92 00 | SD-03 | Backstops | 2.4 | G | |||||
| 07 92 00 | SD-07 | Sealant | 3.3.6 | ||||||
| 08 62 00 | SD-02 | Shop Drawings | 3.2 | G | |||||
| 08 62 00 | SD-03 | Skylights | 2.5.1.1 | ||||||
| 08 62 00 | SD-03 | Warranty | 1.6 | ||||||
| 08 62 00 | SD-06 | Test Reports | 2.1 | ||||||
| 08 62 00 | SD-07 | Skylights | 2.5.1.1 | G | |||||
| 08 62 00 | SD-07 | Qualifications | 1.4 | ||||||
| 09 90 00 | SD-03 | Coating | 2.1 | G | |||||
| 09 90 00 | SD-03 | Manufacturer's Technical Data Sheets | 2.1 | ||||||
| 09 90 00 | SD-04 | Color | 1.1 | G | |||||
| 09 90 00 | SD-04 | Textured Wall Coating System | 1.4.2 | G | |||||
| 09 90 00 | SD-04 | Sample Textured Wall Coating System Mock-Up | 1.4.3 | G | |||||
| 09 90 00 | SD-07 | Applicator's qualifications | 1.3 | ||||||
| 09 90 00 | SD-07 | Qualification Testing | 1.4.1.2 | G | |||||
| 09 90 00 | SD-08 | Application instructions | 3.4.1 | ||||||
| 09 90 00 | SD-08 | Mixing | 3.8.2 | ||||||
| 09 90 00 | SD-08 | Manufacturer's Material Safety Data Sheets | 1.7.2 | ||||||
| 09 90 00 | SD-10 | Coatings | 2.1 | ||||||
| 26 41 01.00 10 | SD-02 | Detail Drawings | 1.3 | ||||||
| 26 41 01.00 10 | SD-07 | Materials | 2.2 |
&L802 CONS/LGCA-3
Lackland AFB TX&C&"Arial,Bold"SUBMITTAL SCHEDULE
MISCELANEOUS ROOF IDIQ
MPLS 09-1011D&RFA3047-10-R-0012
Roofing IDIQ &LSection J - Attachment 2AK&CSCHEDULE - Page &P of &N&R8 Feb 2010