Basic Year
| OFFEROR'S PLEASE TYPE YOUR COMPANY NAME HERE | Original | ||
| CLIN 0001 - BASIC YEAR. CONTRACTOR SHALL FURNISH ALL PLANT, LABOR, MATERIALS AND EQUIPMENT, AND PERFORM ALL WORK IN CONTRACT SPECIFICATIONS AND SUBMITTAL REQUIREMENTS IN ACCORDANCE WITH THE TERMS AND CONDITIONS SET FORTH IN THE PERFORMANCE PERIOD IS 365 CALENDAR DAYS BEGINNING THE DAY OF CONTRACT AWARD. THE MAXIMUM AMOUNT THAT MAY BE ORDERED UNDER THIS CONTRACT IS $10,000,000.00 (CEILING). THE GUARANTEED MINIMUM AMOUNT IS $5,000.00 FOR THE LIFE OF THE CONTRACT. | |||
| ITEM | |||
| NO | WORK ELEMENTS | EST | |
| QTY | UNIT OF MEASURE | UNIT | |
| PRICE | EXTENDED |
AMOUNT
SUB CLIN 0001AA - GENERAL REQUIREMENTS of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of Inches (IN), Square Feet (SF), or Hours (HR), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, GENERAL REQUIREMENTS, SECTIONS 00900, Project Information, thru SECTION 01330, Submittal Procedures, for all previously roofed buildings and exposed surfaces of new buildings, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction. All line items are exact quantities or inclusive. Material waste and usage shall be included in the unit price. Separate payment or increase in units for material waste will not be allowed.
| 0001AA | GENERAL REQUIREMENTS | ||||
| 0001AA01 | Quality Control, testing, core drilling, 4" dia. Core, up to 6" thick slab including bit, layout and set-up | 200 | IN | $ - 0 | $ - 0 |
| 0001AA02 | Quality Control, testing, leak investigation, infrared imager, copy of report to CO | 20 | SF | $ - 0 | $ - 0 |
| 0001AA03 | Quality Control, testing existing roofs for water leaks | 20 | HR | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AA (CLINS 0001AA01 THRU 0001AA03) | $ - 0 | ||||
| SUB CLIN 0001AB - DEMOLITION for roof structures, portions of existing roofs, and miscellaneous facilities shall be measured in units of Square Feet (SF), Board Foot = 12"x12"x1" area of wood (BF), Square = 100 square foot area (SQ), Linear Feet (LF), Cubic Yard (CY), Ton (TON), Loose Cubic Yard (LCY), Week = 5-working days (WK), Day = 8 hours or 0730-1630 hours (Day), Month = 22-days average (Month), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide demolition work as specified in the specifications, SECTIONS 02220, Demolition THRU SECTION 02922, Siding, for all previously roofed buildings, and buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AB | DEMOLITION | ||||
| 0001AB01 | Roofing, built-up, up to 4 ply roof, including gravel | 1,250 | SQ | $ - 0 | $ - 0 |
| 0001AB02 | Gravel removal, minimum | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AB03 | Gravel removal, maximum | 100 | SQ | $ - 0 | $ - 0 |
| 0001AB04 | Asphalt shingles, 1 layer | 20,000 | SF | $ - 0 | $ - 0 |
| 0001AB05 | Roofing, felt paper, #30 felt | 100 | SQ | $ - 0 | $ - 0 |
| 0001AB06 | Roll roofing, cold adhesive | 100 | SQ | $ - 0 | $ - 0 |
| 0001AB07 | Sheathing from roof 1/2" | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AB08 | Sheathing from roof 3/4" | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AB09 | Board sheathing from roof | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AB10 | Saw cutting, sheathing to 1" thick, on room | 500 | LF | $ - 0 | $ - 0 |
| 0001AB11 | Roof insulation board, up to 2" thick | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AB12 | Roof insulation board, over 2" thick | 5,000 | BF | $ - 0 | $ - 0 |
| 0001AB13 | Wall framing, including studs, plates, and blocking, 2" x 4" | 300 | SF | $ - 0 | $ - 0 |
| 0001AB14 | Wall framing, including studs, plates, and blocking, 2" x 6" | 100 | SF | $ - 0 | $ - 0 |
| 0001AB15 | Fascia boards, 1" x 8" | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AB16 | Fascia boards, 2" x 8" | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AB17 | Soffit, T & G wood | 100 | SF | $ - 0 | $ - 0 |
| 0001AB18 | Soffit, T & G Plywood | 100 | SF | $ - 0 | $ - 0 |
| 0001AB19 | Conduct 8 metal TCLP test | 15 | EA | $ - 0 | $ - 0 |
| 0001AB20 | Personal sampling, PCM analysis, NIOSH 7400 | 8 | EA | $ - 0 | $ - 0 |
| 0001AB21 | Dumpster, weekly rental, 1 dump/week, 20 C.Y. capacity (8 tons) | 40 | WK | $ - 0 | $ - 0 |
| 0001AB22 | Haul, per mile, up to 8 C.Y. truck | 2,000 | CY | $ - 0 | $ - 0 |
| 0001AB23 | Dump charges, typical urban city, tipping fees only, bldg construction materials | 100 | TON | $ - 0 | $ - 0 |
| 0001AB24 | Floor protection @ bore hole area | 500 | EA | $ - 0 | $ - 0 |
| 0001AB25 | Remove & reinstall roof exhaust fan, vent/exhaust fan hook-up, EMT & wire | 40 | EA | $ - 0 | $ - 0 |
| 0001AB26 | Flashing and sheet metal | 2,500 | SF | $ - 0 | $ - 0 |
| 0001AB27 | Roof accessories, plumbing vent flashing | 100 | EA | $ - 0 | $ - 0 |
| 0001AB28 | Roof accessories, skylight to 10 S.F. | 45 | EA | $ - 0 | $ - 0 |
| 0001AB29 | Gutters, aluminum, edge hung | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AB30 | Downspouts, including hangers | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AB31 | Sheet metal coping, up to 12" wide | 1,500 | LF | $ - 0 | $ - 0 |
| 0001AB32 | Concrete coping, up to 12" wide | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AB33 | Gravel Stop | 3,000 | LF | $ - 0 | $ - 0 |
| 0001AB34 | Ridge vent strip, aluminum | 300 | LF | $ - 0 | $ - 0 |
| 0001AB35 | Ridge shingles, clay | 300 | LF | $ - 0 | $ - 0 |
| 0001AB36 | Soffit vent strip, aluminum, 3" - 4" wide | 600 | LF | $ - 0 | $ - 0 |
| 0001AB37 | Soffit vent strip and/or fascia vent | 100 | LF | $ - 0 | $ - 0 |
| 0001AB38 | Cant strip | 5,000 | LF | $ - 0 | $ - 0 |
| 0001AB39 | Single ply membrane, ballasted | 100 | SQ | $ - 0 | $ - 0 |
| 0001AB40 | Single ply membrane, fully adhered | 100 | SQ | $ - 0 | $ - 0 |
| 0001AB41 | All-terrain forklift, 45' lift, 35' reach, 9000 lb. capacity | 10 | Month | $ - 0 | $ - 0 |
| 0001AB42 | 12-ton truck-mounted hydraulic crane | 10 | Day | $ - 0 | $ - 0 |
| 0001AB43 | Selective Mech. Demolition, vent flashing & caps | 1,000 | EA | $ - 0 | $ - 0 |
| 0001AB44 | Exterior Surface Preparation, siding, scrape and sand, medium | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AB45 | Exterior Surface Preparation, siding, scrape and sand, heavy | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AB46 | Selective Demo Wood Framing, Hardboard, Vinyl or Aluminum Soffit | 500 | SF | $ - 0 | $ - 0 |
| 0001AB47 | Sanding, Surface Preparation, placement and removal, basic drop cloths | 500 | SF | $ - 0 | $ - 0 |
| 0001AB48 | Asbestos Hazardous Control Activities | 50 | SF | $ - 0 | $ - 0 |
| 0001AB49 | Asbestos Testing | 80 | EA | $ - 0 | $ - 0 |
| 0001AB50 | Roofing Panels (metal or copper) | 10,000 | SF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AB (CLINS 0001AB01 THRU 0001AB50) | $ - 0 | ||||
| SUB CLIN 0001AC - METALS for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Square Feet (SF), Each (EA), Pound (LB), Linear Feet (LF), One-vertical step up on stair (RISER), or Vertical Linear Feet (VLF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 05500, Metals, Miscellaneous or Fabrications for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AC | METALS | |||||
| 0001AC01 | Roof decking, open type B wide rib, galv. 3" deep, 22 gauge under 50 squares | 1,000 | SF | $ - 0 | $ - 0 | |
| 0001AC02 | Roof decking, open type B wide rib, galv. 3" deep, 18 gauge under 50 squares | 1,000 | SF | $ - 0 | $ - 0 | |
| 0001AC03 | Roof decking, end closures | 100 | LF | $ - 0 | $ - 0 | |
| 0001AC04 | 7/8" corrugated roof decking, flexible closure strip | 100 | LF | $ - 0 | $ - 0 | |
| 0001AC05 | Lintels, plain steel angles, shop fabricated, under 500 lb | 50 | LB | $ - 0 | $ - 0 | |
| 0001AC06 | Lintels, plain steel angles, shop fabricated, under 500 to 1000 lb | 50 | LB | $ - 0 | $ - 0 | |
| 0001AC07 | Steel plates (for antennas and microwave dishes), shop fabricated, 1" thick (40.8 lb/sf) | 50 | SF | $ - 0 | $ - 0 | |
| 0001AC08 | Lightweight Framing, angle framing, field fabricated, 4" and larger | 40 | LB | $ - 0 | $ - 0 | |
| 0001AC09 | Lightweight Framing, angle framing, field fabricated, 1" x 1" x 1/8" | 75 | LF | $ - 0 | $ - 0 | |
| 0001AC10 | Lightweight Framing, angle framing, field fabricated, 2" x 2" x 1/4" | 75 | LF | $ - 0 | $ - 0 | |
| 0001AC11 | Lightweight Framing, structural zee framing, field fabricated, 3-1/4" x 5" x 3-1/4" | 50 | LF | $ - 0 | $ - 0 | |
| 0001AC12 | Lightweight Framing, channel framing, field fabricated, C2 x 1.78 | 50 | LF | $ - 0 | $ - 0 | |
| 0001AC13 | Vertical Metal Ladder, shop fabricated steel, 20" wide, bolted to concrete, without cage. (Extend ladder 3'-6" above roof/parapet wall.) | 10 | VLF | $ - 0 | $ - 0 | |
| 0001AC14 | Vertical Metal Ladder, shop fabricated aluminum, bolted to concrete, without cage. | |||||
| (Extend ladder 3'-6" above roof/parapet wall.) | 10 | VLF | $ - 0 | $ - 0 | ||
| 0001AC15 | Railings, Industrial, welded, shop fabricated, 2 rail, posts 5' o.c., 3'-6" high, 1-1/2" pipe | 28 | LF | $ - 0 | $ - 0 | |
| 0001AC16 | Railings, Industrial, welded, shop fabricated, 2 rail, on stairs, primed, 1-1/2" diameter | 28 | LF | $ - 0 | $ - 0 | |
| 0001AC17 | Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 3'-6" wide | 20 | RISER | $ - 0 | $ - 0 | |
| 0001AC18 | Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 4'-0" wide | 20 | RISER | $ - 0 | $ - 0 | |
| 0001AC19 | Permanent U-Bolt roof anchor | 25 | EA | $ - 0 | $ - 0 | |
| 0001AC20 | Temporary (one use) U-Bolt roof anchor | 12 | EA | $ - 0 | $ - 0 | |
| 0001AC21 | Coping, stock units, aluminum, for 12" wall | 250 | LF | $ - 0 | $ - 0 | |
| TOTAL AMOUNT FOR SUB CLIN 0001AC (CLINS 0001AC01 THRU 0001AC21) | $ - 0 | |||||
| SUB CLIN 0001AD - WOOD AND PLASTIC for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Linear Feet (LF), Thousand Board Feet (MBF), Square Feet of Floor (SF FL), or Square Feet (SF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 06100A, Rough Carpentry and Section 06200A, Finish Carpentry, for all existing and previously roofed buildings or buildings with expired roof warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AD | WOOD AND PLASTIC | ||||
| 0001AD01 | Misc. Framing, nailers, treated, wood construction, 2" x 4", pneumatic nailed | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD02 | Misc. Framing, nailers, treated, steel construction, 2" x 4", pneumatic nailed | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD03 | Roof Framing, ridge board, #2 or better, 1" x 6" | 10 | MBF | $ - 0 | $ - 0 |
| 0001AD04 | Roof Framing, ridge board, #2 or better, 2" x 8" | 10 | MBF | $ - 0 | $ - 0 |
| 0001AD05 | Wood framing, Sleepers, on concrete, treated, 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD06 | Wood Framing, soffits & canopies, canopies or soffit framing, 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD07 | Sheathing, Plywood on roof, CDX, 3/4" thick, pneumatic nailed | 2,000 | SF | $ - 0 | $ - 0 |
| 0001AD08 | Sheathing, gypsum, weatherproof, 1/2" thick | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AD09 | Sheathing, wood fiber, regular, no vapor barrier, 5/8" thick | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AD10 | Roof Framing, fascia boards, 2" x 8" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD11 | Soffits, exterior AC plywood, 1/2" thick | 200 | SF | $ - 0 | $ - 0 |
| 0001AD12 | Rafter extension (tails), 2" x 6" ordinary | 200 | LF | $ - 0 | $ - 0 |
| 0001AD13 | Rafter extension (tails), 2" x 8" ordinary | 200 | LF | $ - 0 | $ - 0 |
| 0001AD14 | Laminated Roof Deck, cedar, 3" thick | 200 | SF | $ - 0 | $ - 0 |
| 0001AD15 | Laminated Roof Deck, cedar, 4" thick | 200 | SF | $ - 0 | $ - 0 |
| 0001AD16 | Blocking, miscellaneous, to wood construction 2" x 4", Pneumatic Nailed | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD17 | Blocking, miscellaneous, to wood construction 2" x 8", Pneumatic Nailed | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD18 | Blocking, miscellaneous, to steel construction 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD19 | Blocking, miscellaneous, to steel construction 2" x 8" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AD20 | Plywood, underlayment grade, 1/2" thick, pneumatic nailed | 100 | SF FLR | $ - 0 | $ - 0 |
| 0001AD21 | Plywood, underlayment grade, 3/4" thick, pneumatic nailed | 100 | SF SFR | $ - 0 | $ - 0 |
| 0001AD22 | Oriented Strand Board, underlayment grade, 0.225 inch thick | 10 | MBF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AD (CLINS 0001AD01 THRU 0001AD22) | $ - 0 | ||||
| SUB CLIN 0001AE - THERMAL & MOISTURE PROTECTION of buildings, warehouses, structures, & miscellaneous facilities shall be measured by units of Square or 100 square feet (SQ), Linear Feet (LF), Board Foot (BF), Square Feet, an area 12"x12" (SF), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Board & Block Insulation, thru Section 07920, Joint Sealants, for all previously roofed buildings, or new buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AE | THERMAL & MOISTURE PROTECTION | ||||
| 0001AE01 | Roof Curb, untreated, 2" x 6" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AE02 | Roof Cant, split 4" x 4" | 2 | MBF | $ - 0 | $ - 0 |
| 0001AE03 | Roof Curb, untreated, 2" x 12" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AE04 | Roof Cant, split 6" x 6" | 1 | MBF | $ - 0 | $ - 0 |
| 0001AE05 | BUR, asph. Flood coat, smooth surface, 4 plies #15 asphalt felt, mopped, on nailable decks | 200 | SQ | $ - 0 | $ - 0 |
| 0001AE06 | BUR, asph. Flood coat, smooth surface, 4 plies #15 organic felt, mopped | 200 | SQ | $ - 0 | $ - 0 |
| 0001AE07 | APP modified bituminous membrane, Granule surface cap sheet, poly. Reinf., torched 180 mils | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AE08 | APP modified bituminous membrane, Granule surface flashing, torched, 180 mils | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AE09 | Asphalt Shingles, premium, laminated multi-layered shingles, Class A, 260-300 lb, 4 bundles/sq, pneumatic nailed | 100 | SQ | $ - 0 | $ - 0 |
| 0001AE10 | Self adhering polyethylene and rubberized asphalt underlayment | 100 | SQ | $ - 0 | $ - 0 |
| 0001AE11 | Asphalt ridge shingles, pneumatic nailed | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AE12 | Clay Tile, access included, ASTM C1167, Spanish tile, red (Clay tile, remove same, salvage, reinstall same tile) | 4,000 | SF | $ - 0 | $ - 0 |
| 0001AE13 | Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., fully adhered with adhesive (single ply membrane) | 100 | SQ | $ - 0 | $ - 0 |
| 0001AE14 | Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., loose-laid & ballasted with stone/gravel (12 PSF) single ply membrane | 100 | SQ | $ - 0 | $ - 0 |
| 0001AE15 | Cant, 4" x 4" foam glass | 5,000 | LF | $ - 0 | $ - 0 |
| 0001AE16 | Asphalt felt, #30, 2 sq per roll | 100 | SQ | $ - 0 | $ - 0 |
| 0001AE17 | Ridge Vent, Alum., strips, Painted finish | 500 | LF | $ - 0 | $ - 0 |
| 0001AE18 | Ridge Vent, Alum., end caps | 20 | EA | $ - 0 | $ - 0 |
| 0001AE19 | Roof deck insulation, perlite, 3/4" thick R2.08 | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AE20 | Roof deck Insulation, polyisocyanurate, 2#/CF density, 1.5" thick | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AE21 | Roof deck Insulation, polyisocyanurate, 2#/CF density, 2" thick | 20,000 | SF | $ - 0 | $ - 0 |
| 0001AE22 | Roof deck Insulation, polyisocyanurate, 2#/CF density, 2-1/2" thick | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AE23 | Roof deck Insulation, polyisocyanurate, 2#/CF density, 3" thick | 10,000 | SF | $ - 0 | $ - 0 |
| 0001AE24 | Steel Roofing Panels, Flat profile, 1-3/4" standing seams, 12" wide, standard finish, 26 gauge | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AE25 | Steel Roofing Panels, Flat profile, 1-3/4" standing seam, 12" wide, standard finish, 24 gauge | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AE26 | Steel Roofing Panels, Ridge, galvanized, 10" wide | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AE27 | Roof Deck Insulation, Polyisocyanurate tapered for drainage | 1,000 | BF | $ - 0 | $ - 0 |
| 0001AE28 | Soffit, baked enamel on steel, 16 or 18 gauge, color | 300 | SF | $ - 0 | $ - 0 |
| 0001AE29 | Gutters, Stainless Steel, half round or box, stock, 5" wide | 500 | LF | $ - 0 | $ - 0 |
| 0001AE30 | Gutters, Steel, galv, half round or box, 26 gauge, stock, 5' wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE31 | Gutters, Steel galv, half round or box, 26 gauge, stock, 6" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE32 | Gutter guard, 6" wide, aluminum mesh | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AE33 | Sheet metal flashing and counter flashing, including up to four bends, aluminum, mastic coated 2 sides, .016" thick | 300 | SF | $ - 0 | $ - 0 |
| 0001AE34 | Sheet metal flashing and counter flashing, including up to four bends, aluminum, mill finish, .032" thick | 300 | SF | $ - 0 | $ - 0 |
| 0001AE35 | Sheet metal flashing and counter flashing, aluminum mill finish, 12" x 12" step flashing, 0.016" thick | 250 | EA | $ - 0 | $ - 0 |
| 0001AE36 | Sheet metal flashing and counter flashing, steel sheets, galvanized, 20 gauge | 250 | SF | $ - 0 | $ - 0 |
| 0001AE37 | Sheet metal flashing and counter flashing, copper, 20 oz sheets, under 1000 lbs | 1,250 | SF | $ - 0 | $ - 0 |
| 0001AE38 | Sheet metal flashing and counter flashing, copper, 20 oz sheets, over 4000 lbs | 2,250 | SF | $ - 0 | $ - 0 |
| 0001AE39 | Sheet metal flashing and counter flashing, copper W shape for valleys, 16 oz, 24" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE40 | Downspouts, steel, galvanized, round, corrugated, 5" diameter, 26 gauge | 100 | LF | $ - 0 | $ - 0 |
| 0001AE41 | Downspouts, steel, galvanized, round, corrugated, 6" diameter, 26 gauge | 100 | LF | $ - 0 | $ - 0 |
| 0001AE42 | Pre-Finish Gutters, 5" x 6" including bends and clips for complete usable system | 100 | LF | $ - 0 | $ - 0 |
| 0001AE43 | Gutters, Alum., stock units, 5" K type, .032" thick, enameled | 100 | LF | $ - 0 | $ - 0 |
| 0001AE44 | Gutters, copper, half round, 16 oz., stock unit, 4" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE45 | Gutters, copper, half round, 16 oz., stock unit, 6" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE46 | Downspouts, lead-coated copper, round, stock, 4" Dia. | 10 | LF | $ - 0 | $ - 0 |
| 0001AE47 | Downspouts, lead-coated copper, round, stock, 6" Dia. | 10 | LF | $ - 0 | $ - 0 |
| 0001AE48 | Elbows, 90 degrees Elbows, PVC, 4" Dia. | 5 | EA | $ - 0 | $ - 0 |
| 0001AE49 | Elbows, copper, solder joints, copper x copper, 4" | 1 | EA | $ - 0 | $ - 0 |
| 0001AE50 | Cellular Glass Boards, Type IV | 500 | SF | $ - 0 | $ - 0 |
| 0001AE51 | Drip Edge, Aluminum, .016" thick, 5" wide, mill finish | 100 | LF | $ - 0 | $ - 0 |
| 0001AE52 | Drip Edge, Aluminum, .016" thick, 8" wide, mill finish | 100 | LF | $ - 0 | $ - 0 |
| 0001AE53 | Drip Edge, Aluminum, .016" thick, vented, mill finish | 100 | LF | $ - 0 | $ - 0 |
| 0001AE54 | Drip Edge, galvanized, 5" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE55 | Drip Edge, galvanized, 8" wide | 100 | LF | $ - 0 | $ - 0 |
| 0001AE56 | Gravel Stop, galv. Steel, 24 gauge., 4" leg, plain, w/cont. cleat, 6" face | 100 | LF | $ - 0 | $ - 0 |
| 0001AE57 | Gravel Stop, stainless steel, 24 gauge., 6" face height | 100 | LF | $ - 0 | $ - 0 |
| 0001AE58 | Reglet, aluminum, .025" thick, in concrete parapet | 10 | LF | $ - 0 | $ - 0 |
| 0001AE59 | Reglet, copper, 10 oz, in concrete parapet | 10 | LF | $ - 0 | $ - 0 |
| 0001AE60 | Reglet, galv. Steel, 24 gauge., in concrete parapet | 1 | LF | $ - 0 | $ - 0 |
| 0001AE61 | Reglet, stainless steel, .020" thick, in concrete parapet | 1 | LF | $ - 0 | $ - 0 |
| 0001AE62 | Reglet, polyvinyl chloride, Type II, Grade I, Class 14333-D, .075" minimum thickness (temp construction) | 1 | LF | $ - 0 | $ - 0 |
| 0001AE63 | Reglet, counter flashing for above, 12" wide, stainless steel, .020" thick | 1 | LF | $ - 0 | $ - 0 |
| 0001AE64 | Reglet, counter flashing for above, 12" wide, copper, 10 oz. | 300 | LF | $ - 0 | $ - 0 |
| 0001AE65 | Reglet, counter flashing for above, 12" wide, aluminum .032" | 300 | LF | $ - 0 | $ - 0 |
| 0001AE66 | Reglet, counter flashing for above, 12" wide, galvanized steel, .020" thick | 100 | LF | $ - 0 | $ - 0 |
| 0001AE67 | Expansion Jt., butyl or neoprene center with foam insulation, metal flanges, lead-coated copper, 16 oz. for opng to 2-1/2'' | 250 | LF | $ - 0 | $ - 0 |
| 0001AE68 | Expansion Jt., butyl or neoprene center with foam insulation, metal flanges, lead-coated copper, 16 oz. for opening to 5" | 100 | LF | $ - 0 | $ - 0 |
| 0001AE69 | Expansion Jt., wall joint, closed cell foam on PVC cover, 12" wide | 300 | LF | $ - 0 | $ - 0 |
| 0001AE70 | Expansion Jt., roof joint with extruded aluminum cover, 2" | 100 | LF | $ - 0 | $ - 0 |
| 0001AE71 | Expansion Jt., roof joint with extruded aluminum cover | 100 | LF | $ - 0 | $ - 0 |
| 0001AE72 | Roof vent mushroom for built-Up roofs, alum., (1-1/2" plumbing vents) | 30 | EA | $ - 0 | $ - 0 |
| 0001AE73 | Walkway, for BUR, asphalt impregnated, 3' x 6' x 1/2" thick | 400 | SF | $ - 0 | $ - 0 |
| 0001AE74 | Walkway, for BUR, concrete patio blocks, 2" thick, natural | 100 | SF | $ - 0 | $ - 0 |
| 0001AE75 | Bentonite Waterproofing, Granular Bentonite, 3/8" thick, troweled on | 100 | SF | $ - 0 | $ - 0 |
| 0001AE76 | Cementitious Waterproofing, one coat cement base, 1/8" application, spray-on | 100 | SF | $ - 0 | $ - 0 |
| 0001AE77 | Backer rod, polyethylene, 1/2" diameter | 10 | CLF | $ - 0 | $ - 0 |
| 0001AE78 | Backer rod, polyethylene, 1" diameter | 10 | CLF | $ - 0 | $ - 0 |
| 0001AE79 | Downspout Boot, 12 gauge, G90, with receiving bell, 6' | 10 | EA | $ - 0 | $ - 0 |
| 0001AE80 | Water Repellents, water base liquid, roller applied | 100 | SF | $ - 0 | $ - 0 |
| 0001AE81 | Water Repellents, silicone or separate, sprayed on CMU, 2 coats | 100 | SF | $ - 0 | $ - 0 |
| 0001AE82 | Clips for Standing Seam Metal Panels | 500 | EA | $ - 0 | $ - 0 |
| 0001AE83 | Cont. Gravel Guard Clip | 1,000 | EA | $ - 0 | $ - 0 |
| 0001AE84 | Laminated Sheet Flashing, including up to 4 bends, Lead-coated copper, fabric-backed, 2 oz. | 100 | SF | $ - 0 | $ - 0 |
| 0001AE85 | Laminated Sheet Flashing, including up to 4 bends, Lead-coated copper, fabric-backed, 5 oz. | 100 | SF | $ - 0 | $ - 0 |
| 0001AE86 | Laminated Sheet Flashing, including up to 4 bends, Lead on copper and fabric, 7 oz. | 100 | SF | $ - 0 | $ - 0 |
| 0001AE87 | Rigid Insulation, for walls, fiberglass, 1.5#/CF, unfaced,1" thick, R4.1 | 100 | SF | $ - 0 | $ - 0 |
| 0001AE88 | Rigid Insulation, for walls, fiberglass, 1.5#/CF, unfaced, 3" thick, R12.4 | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AE89 | Rigid Insulation, for walls, expanded polystyrene, 1" thick, R3.85 | 100 | SF | $ - 0 | $ - 0 |
| 0001AE90 | Rigid Insulation, for walls, expanded polystyrene, 3" thick, R11.49 | 100 | SF | $ - 0 | $ - 0 |
| 0001AE91 | Gravel Stop, aluminum, .050" thick, 6" face height, duranodic finish (one-piece) | 100 | LF | $ - 0 | $ - 0 |
| 0001AE92 | Gravel Stop, aluminum, .050" thick, 8" face height, duranodic finish (one-piece) | 100 | LF | $ - 0 | $ - 0 |
| 0001AE93 | Gravel Stop, aluminum, .080" thick, 12" face height, duranodic finish (two-piece) | 100 | LF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AE (CLINS 0001AE01 THRU 0001AE93) | $ - 0 | ||||
| SUB CLIN 0001AF - DOORS & WINDOWS of buildings, warehouses, structures and miscellaneous facilities and buildings/structures associated with them shall be measured in units of Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 08600, Skylights and SECTION 05500, Metals, Miscellaneous and Fabrications for all previously roofed buildings or new buildings with expired warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AF | DOORS & WINDOWS | ||||
| 0001AF01 | Roof Hatch, 2'-6" x 4'-6", Galvanized steel curb and aluminum cover | 5 | EA | $ - 0 | $ - 0 |
| 0001AF02 | Vapor Retarders, polyethylene vapor barrier, standard, .006" thick | 50 | SQ | $ - 0 | $ - 0 |
| 0001AF03 | Asphalt Roll Roofing, mineral surface for open valleys | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AF04 | Mineral Fiber Insulation Board | 200 | SF | $ - 0 | $ - 0 |
| 0001AF05 | Skylight, plastic dome, ventilating insulated Plexiglas dome with curb mounting, 36" x 36" | 10 | EA | $ - 0 | $ - 0 |
| 0001AF06 | Skylight, fiberglass panels, to 30 SF | 10 | EA | $ - 0 | $ - 0 |
| 0001AF07 | Skylight, fiberglass panels, add for excess over 30 SF | 100 | SF | $ - 0 | $ - 0 |
| 0001AF08 | Window Restoration - Silicone caulking at perimeter | 1,000 | LF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AF (CLINS 0001AF01 THRU 0001AF08) | $ - 0 | ||||
| SUB CLIN 0001AG - FINISHES on buildings, garages, structures and miscellaneous facilities shall be measured in units of Square Foot (SF) or Linear Foot (LF), excluding elevated water storage tanks, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 09900, Paints and Coatings, for all previously roofed buildings or new buildings with expired warranties including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AG | FINISHES | ||||
| 0001AG01 | Walls & Ceilings, Interior, masonry or concrete block, silicone, water repellent, 2-coat, spray | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG02 | Trim, Exterior, gutters & downspouts brushwork, metal, zinc chromate paint, 5", first coat | 300 | LF | $ - 0 | $ - 0 |
| 0001AG03 | Trim, Exterior, gutters & downspouts brushwork, metal, zinc chromate paint, 5", second coat | 100 | LF | $ - 0 | $ - 0 |
| 0001AG04 | Trim, Exterior, gutters & downspouts, brushwork, metal, zinc chromate paint, 5", third coat | 100 | LF | $ - 0 | $ - 0 |
| 0001AG05 | Doors and Windows, Exterior, door frames & trim only, brushwork, primer & 2 coats, exterior latex | 100 | LF | $ - 0 | $ - 0 |
| 0001AG06 | Trim, Exterior, fascia, latex paint, one coat coverage, 1" x 6" to 1" x 10" brushwork | 300 | LF | $ - 0 | $ - 0 |
| 0001AG07 | Trim, Exterior, Molding, exterior, up to 14" wide, Brushwork, primer & 2 coats exterior latex | 300 | LF | $ - 0 | $ - 0 |
| 0001AG08 | Wall coatings, epoxy coatings, minimum | 300 | SF | $ - 0 | $ - 0 |
| 0001AG09 | Wall coatings, epoxy coatings, maximum | 100 | SF | $ - 0 | $ - 0 |
| 0001AG10 | Exterior steel coatings, cold galvanizing, brush in field | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG11 | Exterior steel coatings, paints & protective coatings, sprayed in field, alkyds, primer | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG12 | Exterior steel coatings, paints & protective coatings, sprayed in field, alkyds, gloss topcoats | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG13 | Exterior steel coatings, paints & protective coatings, sprayed in field, Latex primer | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG14 | Exterior steel coatings, paints & protective coatings, sprayed in field, topcoats | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AG15 | Walls and Ceilings, Interior, concrete, drywall or plaster, oil base, paint 3 coats, smooth finish, brushwork (deduct 10% material cost for latex; for work 8' - 15' H, add 10% labor cost; for work over 15' H, add 20% labor cost) | 1,000 | SF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AG (CLINS 0001AG01 THRU 0001AG15) | $ - 0 | ||||
| SUB CLIN 0001AH - ROOF MAINTENANCE & REPAIR of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of One Hundred or 100 in count (C), Linear Foot (LF), Each (EA), Square Foot (SF), Loose Cubic Yard (LCY), Bank Cubic Yard (BCY), Square (SQ = 100 square feet), or Cubic Foot (CF) excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Blanket & Block Insulation thru SECTION 07920, Joint Sealants for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AH | ROOF MAINTENANCE & REPAIR | ||||
| 0001AH01 | Sheet metal (splash pan) copper, 24 oz. sheet, under 1000 lbs. | 50 | SF | $ - 0 | $ - 0 |
| 0001AH02 | Sheet metal (splash pan) stainless steel sheets, 24 gauge, .025" thick | 30 | SF | $ - 0 | $ - 0 |
| 0001AH03 | Sheet metal (splash pan, ridge/valley plates and flat copper roofing) steel sheets galvanized, 20 gauge | 100 | SF | $ - 0 | $ - 0 |
| 0001AH04 | Remove existing caulking, clean opening and recaulk around all surfaces | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AH05 | Remove fill material from existing pitch pans entirely and refill with new pourable sealant material | 100 | EA | $ - 0 | $ - 0 |
| 0001AH06 | Apply roof cement under loose shingle tabs | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH07 | Remove and replace damaged shingles | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH08 | Remove deteriorated steel Roof deck and replace with new matching steel roof deck | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH09 | Remove & Reinstall lightning protection system (to include all necessary replacement components and reinstallation must be certifiable by the Underwriters Laboratories). | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AH10 | Rework steel roof panel. Lift panel sufficiently to allow working the lap without crimping the metal panel. Remove fasteners, sealant tape and caulking on exposed portion. Clean panel, apply new sealant tape, caulking and reinstall panel using new fasteners. | 100 | EA | $ - 0 | $ - 0 |
| 0001AH11 | Coping, stock units, precast concrete, 10" wide, 4" tapers to 3-1/2", 8" wall | 100 | LF | $ - 0 | $ - 0 |
| 0001AH12 | Coping, stock units, limestone for 12" wall, 4" thick | 200 | LF | $ - 0 | $ - 0 |
| 0001AH13 | Furnish and install roof drain sleeve, including preparation of existing drain to receive the sleeve. Includes all necessary hardware and materials to form a functional drain | 100 | EA | $ - 0 | $ - 0 |
| 0001AH14 | Cementitious Parging, 2 coats, 1/2" thick, waterproofed Portland Cement | 500 | SF | $ - 0 | $ - 0 |
| 0001AH15 | Precast concrete splash block | 200 | EA | $ - 0 | $ - 0 |
| 0001AH16 | Seal gutter with elastomeric membrane; 1/16" urethane troweled | 100 | SF | $ - 0 | $ - 0 |
| 0001AH17 | Remove & replace screw fasteners, alum., self tapping, neoprene washers, 1" | 100 | C | $ - 0 | $ - 0 |
| 0001AH18 | Line gutter with EPDM, 45 mils, fully adhered with adhesive | 100 | SF | $ - 0 | $ - 0 |
| 0001AH19 | Elastomeric Waterproofing, 50 mil, reinforced, stucco texture, on horizontal or vertical surfaces | 100 | SF | $ - 0 | $ - 0 |
| 0001AH20 | Elastomeric Sheet Waterproofing, EPDM, nylon reinforced sheets, 45 mils thick | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH21 | Repair single ply roofing felt | 500 | SF | $ - 0 | $ - 0 |
| 0001AH22 | Remove abandoned gas/water line, up thru 1-1/2" diameter | 100 | LF | $ - 0 | $ - 0 |
| 0001AH23 | Repair blister on BUR, asphalt flood coat w/gravel-slag | 5,000 | SF | $ - 0 | $ - 0 |
| 0001AH24 | Repair blister on BUR, tarred felts with coal tar pitch and gravel-slag | 2,500 | SF | $ - 0 | $ - 0 |
| 0001AH25 | Repair Roof, mineral surface cap sheet | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH26 | Repair modified bitumen roofing, SBS modified, smooth surface cap sheet, mopped | 1,000 | SF | $ - 0 | $ - 0 |
| 0001AH27 | Repair stone coping, mortar, Type PM, 1:1:6 mix, 2500 psi | 10 | CF | $ - 0 | $ - 0 |
| 0001AH28 | Roof Patch - BUR, asph flood coat, smooth surface, coated & saturated base sheet, 4-ply #15 asphalt felt, mopped, (Note - items for partial roof replacement only) | 10 | SQ | $ - 0 | $ - 0 |
| 0001AH29 | Roof Patch - BUR, asph flood coat, smooth surface, coated & saturated base sheet, 4-ply #15 organic felt, mopped, (Note - items for partial roof replacement only) | 10 | SQ | $ - 0 | $ - 0 |
| 0001AH30 | Remove & replace Roof Drain - Complete; (including demo, new drain, rework lead flashing, and patch roof) | 30 | EA | $ - 0 | $ - 0 |
| 0001AH31 | Remove & reinstall new corrugated roof panel, on steel frame, painted, .032" thick | 25 | SF | $ - 0 | $ - 0 |
| 0001AH32 | Lightning Protection, Air Terminals & base, copper, 3/8" dia x 10" (to 75' high) | 10 | EA | $ - 0 | $ - 0 |
| 0001AH33 | Grounding, rod, copper clad, 10' long, 3/4" diameter | 10 | EA | $ - 0 | $ - 0 |
| 0001AH34 | Lightning Protection, Arrester, 650 volt AC to ground | 10 | EA | $ - 0 | $ - 0 |
| 0001AH35 | Remove/Raise & Reset Mechanical Equipment | 15 | EA | $ - 0 | $ - 0 |
| 0001AH36 | Excavating, Trench, by hand with pick & shovel 2' to 6' deep, Heavy Soil | 10 | BCY | $ - 0 | $ - 0 |
| 0001AH37 | Backfill, General, by hand, no compaction, heavy soil | 10 | LCY | $ - 0 | $ - 0 |
| 0001AH38 | Restoring Low Slope Roofs - Restoration material (Equal to Mule-Hide Prod. Co. Inc., A-300 Finish) | 200 | SF | $ - 0 | $ - 0 |
| 0001AH39 | Temporary Fencing, rented chain link, 6' high, to 1000' (up to 12 mo.) | 1,000 | LF | $ - 0 | $ - 0 |
| 0001AH40 | Temporary Fencing, rented chain link, 6' high, over 1000' (up to 12 mo.) | 5,000 | LF | $ - 0 | $ - 0 |
| 0001AH41 | Clay Tile, Replacement | 200 | SF | $ - 0 | $ - 0 |
| 0001AH42 | Metal Panel Roof Repair/Replacement for more than 2.5% | 250 | SF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 0001AH (CLINS 0001AH01 THRU 0001AH42) | $ - 0 | ||||
| SUB CLIN 0001AI - ROOF ACCESSORIES on buildings, garages, structures and miscellaneous facilities shall be measured in units of Each (EA) or Linear Foot (LF), excluding elevated water storage tanks, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 09900, Paints and Coatings, for all previously roofed buildings or new buildings with expired warranties including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 0001AI | ROOF ACCESSORIES | |||||
| 0001AI01 | Vent caps, cast iron, 2-1/2" to 3-5/8" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI02 | Vent caps, cast iron, 4" to 4-1/8" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI03 | Vent flashing, aluminum with lead ring, 2" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI04 | Vent flashing, aluminum with lead ring, 4" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI05 | Vent flashing, copper with neoprene ring, 2" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI06 | Vent flashing, copper with neoprene ring, 4" pipe | 100 | EA | $ - 0 | $ - 0 | |
| 0001AI07 | Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 6" diameter | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI08 | Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 4" diameter | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI09 | Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 8" diameter | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI10 | Pipe, plastic, DWV type, schedule 40, couplings 10' o.c, clevis hanger assembly 3/10', ABS, schedule 40, foam core type, plain end black, 4" dia. | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI11 | Pipe, plastic, DWV type, schedule 40, couplings 10' o.c, clevis hanger assembly, 3/10', ABS schedule 40, foam core type, plain end black, 6" dia. | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI12 | Roof Drains, flat metal deck, C.I. body, 12" C.I. dome, 3" pipe size | 120 | LF | $ - 0 | $ - 0 | |
| 0001AI13 | Roof Drains, flat metal deck, C.I. body, 12" C.I. dome, 6" pipe size | 140 | LF | $ - 0 | $ - 0 | |
| TOTAL AMOUNT FOR SUB CLIN 0001AI (CLINS 0001AI01 THRU 0001AI13) | $ - 0 | |||||
| SUB TOTAL AMOUNT FOR SUB CLINS: | ||||||
| 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH & 0001AI | $ - 0 | |||||
| SUB CLIN 0001AJ - COMPENSATE TIME (Section 00 30 00, Paragraph 3) for work occurring in the AF ISR, TCC and WHMC areas, the Offeror shall include an additional "PERCENTAGE" mark-up to compensate the time delay in entering and exiting the secured areas and for working in a facility over 3-stories in height. |
Note 1 (SOLICITATION): SUB CLIN 0001AJ will be applied to all BASIC YEAR SUB CLINS 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH & 0001AI in order to determine a TOTAL AMOUNT for the BASIC YEAR.
| Note 2 (CONTRACT / DELIVERY ORDERS): SUB CLIN 0001AJ will be applied ONLY to BASIC YEAR Projects that meet the COMPENSATE TIME requirements. | 0.00% | $ - 0 | |||
| SUB TOTAL AMOUNT FOR SUB CLINS: | |||||
| 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH / 0001AI & 0001AJ | $ - 0 | ||||
| 0001AK | SUB CLIN 0001AK - CE SOFTWARE REQUIREMENTS | ||||
| (Section 00 30 00, Paragraph 39.12.1). * Applicable only for Basic Year | 2 | EA | $ - 0 | $ - 0 | |
| TOTAL AMOUNT FOR CLIN 0001 - BASIC YEAR: | |||||
| SUB CLINS 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH / 0001AI / 0001AJ & 0001AK | $ - 0 |
&"Times New Roman,Regular"&10 802 CONS/LGCA-3
| Lackland AFB TX | &"Times New Roman,Bold"ROOFING IDIQ CONTRACT |
| (BASIC YEAR) | &"Times New Roman,Regular"&10FA3047-10-R-0012 |
10 May 10
&"Times New Roman,Regular"Section J - Attachment 1 &"Times New Roman,Bold""SOURCE SELECTION INFORMATION" &"Times New Roman,Regular"Page &P of &N
Option Year One
| OFFEROR'S PLEASE TYPE YOUR COMPANY NAME HERE | Original | ||
| CLIN 1001 - OPTION YEAR ONE. CONTRACTOR SHALL FURNISH ALL PLANT, LABOR, MATERIALS AND EQUIPMENT, AND PERFORM ALL WORK IN CONTRACT SPECIFICATIONS AND SUBMITTAL REQUIREMENTS IN ACCORDANCE WITH THE TERMS AND CONDITIONS SET FORTH IN THE PERFORMANCE PERIOD IS 365 CALENDAR DAYS BEGINNING THE DAY OF CONTRACT AWARD. THE MAXIMUM AMOUNT THAT MAY BE ORDERED UNDER THIS CONTRACT IS $10,000,000.00 (CEILING). | |||
| ITEM | |||
| NO | WORK ELEMENTS | EST | |
| QTY | UNIT OF MEASURE | UNIT | |
| PRICE | EXTENDED |
AMOUNT
SUB CLIN 1001AA - GENERAL REQUIREMENTS of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of Inches (IN), Square Feet (SF), or Hours (HR), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, GENERAL REQUIREMENTS, SECTIONS 00900, Project Information, thru SECTION 01330, Submittal Procedures, for all previously roofed buildings and exposed surfaces of new buildings, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction. All line items are exact quantities or inclusive. Material waste and usage shall be included in the unit price. Separate payment or increase in units for material waste will not be allowed.
| 1001AA | GENERAL REQUIREMENTS | ||||
| 1001AA01 | Quality Control, testing, core drilling, 4" dia. Core, up to 6" thick slab including bit, layout and set-up | 200 | IN | $ - 0 | $ - 0 |
| 1001AA02 | Quality Control, testing, leak investigation, infrared imager, copy of report to CO | 20 | SF | $ - 0 | $ - 0 |
| 1001AA03 | Quality Control, testing existing roofs for water leaks | 20 | HR | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 1001AA (CLINS 1001AA01 THRU 1001AA03) | $ - 0 | ||||
| SUB CLIN 1001AB - DEMOLITION for roof structures, portions of existing roofs, and miscellaneous facilities shall be measured in units of Square Feet (SF), Board Foot = 12"x12"x1" area of wood (BF), Square = 100 square foot area (SQ), Linear Feet (LF), Cubic Yard (CY), Ton (TON), Loose Cubic Yard (LCY), Week = 5-working days (WK), Day = 8 hours or 0730-1630 hours (Day), Month = 22-days average (Month), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide demolition work as specified in the specifications, SECTIONS 02220, Demolition THRU SECTION 02922, Sodding, for all previously roofed buildings, and buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 1001AB | DEMOLITION | ||||
| 1001AB01 | Roofing, built-up, up to 4 ply roof, including gravel | 1,250 | SQ | $ - 0 | $ - 0 |
| 1001AB02 | Gravel removal, minimum | 10,000 | SF | $ - 0 | $ - 0 |
| 1001AB03 | Gravel removal, maximum | 100 | SQ | $ - 0 | $ - 0 |
| 1001AB04 | Asphalt shingles, 1 layer | 20,000 | SF | $ - 0 | $ - 0 |
| 1001AB05 | Roofing, felt paper, #30 felt | 100 | SQ | $ - 0 | $ - 0 |
| 1001AB06 | Roll roofing, cold adhesive | 100 | SQ | $ - 0 | $ - 0 |
| 1001AB07 | Sheathing from roof 1/2" | 5,000 | SF | $ - 0 | $ - 0 |
| 1001AB08 | Sheathing from roof 3/4" | 10,000 | SF | $ - 0 | $ - 0 |
| 1001AB09 | Board sheathing from roof | 5,000 | SF | $ - 0 | $ - 0 |
| 1001AB10 | Saw cutting, sheathing to 1" thick, on room | 500 | LF | $ - 0 | $ - 0 |
| 1001AB11 | Roof insulation board, up to 2" thick | 10,000 | SF | $ - 0 | $ - 0 |
| 1001AB12 | Roof insulation board, over 2" thick | 5,000 | BF | $ - 0 | $ - 0 |
| 1001AB13 | Wall framing, including studs, plates, and blocking, 2" x 4" | 300 | SF | $ - 0 | $ - 0 |
| 1001AB14 | Wall framing, including studs, plates, and blocking, 2" x 6" | 100 | SF | $ - 0 | $ - 0 |
| 1001AB15 | Fascia boards, 1" x 8" | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AB16 | Fascia boards, 2" x 8" | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AB17 | Soffit, T & G wood | 100 | SF | $ - 0 | $ - 0 |
| 1001AB18 | Soffit, T & G Plywood | 100 | SF | $ - 0 | $ - 0 |
| 1001AB19 | Conduct 8 metal TCLP test | 15 | EA | $ - 0 | $ - 0 |
| 1001AB20 | Personal sampling, PCM analysis, NIOSH 7400 | 8 | EA | $ - 0 | $ - 0 |
| 1001AB21 | Dumpster, weekly rental, 1 dump/week, 20 C.Y. capacity (8 tons) | 40 | WK | $ - 0 | $ - 0 |
| 1001AB22 | Haul, per mile, up to 8 C.Y. truck | 2,000 | CY | $ - 0 | $ - 0 |
| 1001AB23 | Dump charges, typical urban city, tipping fees only, bldg constr matls | 100 | TON | $ - 0 | $ - 0 |
| 1001AB24 | Floor protection @ bore hole area | 500 | EA | $ - 0 | $ - 0 |
| 1001AB25 | Remove & reinstall roof exhaust fan, vent/exhaust fan hook-up, EMT & wire | 40 | EA | $ - 0 | $ - 0 |
| 1001AB26 | Flashing and sheet metal | 2,500 | SF | $ - 0 | $ - 0 |
| 1001AB27 | Roof accessories, plumbing vent flashing | 100 | EA | $ - 0 | $ - 0 |
| 1001AB28 | Roof accessories, skylight to 10 S.F. | 45 | EA | $ - 0 | $ - 0 |
| 1001AB29 | Gutters, aluminum, edge hung | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AB30 | Downspouts, including hangers | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AB31 | Sheet metal coping, up to 12" wide | 1,500 | LF | $ - 0 | $ - 0 |
| 1001AB32 | Concrete coping, up to 12" wide | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AB33 | Gravel Stop | 3,000 | LF | $ - 0 | $ - 0 |
| 1001AB34 | Ridge vent strip, aluminum | 300 | LF | $ - 0 | $ - 0 |
| 1001AB35 | Ridge shingles, clay | 300 | LF | $ - 0 | $ - 0 |
| 1001AB36 | Soffit vent strip, aluminum, 3" - 4" wide | 600 | LF | $ - 0 | $ - 0 |
| 1001AB37 | Soffit vent strip and/or fascia vent | 100 | LF | $ - 0 | $ - 0 |
| 1001AB38 | Cant strip | 5,000 | LF | $ - 0 | $ - 0 |
| 1001AB39 | Single ply membrane, ballasted | 100 | SQ | $ - 0 | $ - 0 |
| 1001AB40 | Single ply membrane, fully adhered | 100 | SQ | $ - 0 | $ - 0 |
| 1001AB41 | All-terrain forklift, 45' lift, 35' reach, 9000 lb. capacity | 10 | Month | $ - 0 | $ - 0 |
| 1001AB42 | 12-ton truck-mounted hydraulic crane | 10 | Day | $ - 0 | $ - 0 |
| 1001AB43 | Selective Mech. Demolition, vent flashing & caps | 1,000 | EA | $ - 0 | $ - 0 |
| 1001AB44 | Exterior Surface Preparation, siding, scrape and sand, medium | 1,000 | SF | $ - 0 | $ - 0 |
| 1001AB45 | Exterior Surface Preparation, siding, scrape and sand, heavy | 1,000 | SF | $ - 0 | $ - 0 |
| 1001AB46 | Selective Demo Wood Framing, Hardboard, Vinyl or Aluminum Soffit | 500 | SF | $ - 0 | $ - 0 |
| 1001AB47 | Sanding, Surface Preparation, placement and removal, basic drop cloths | 500 | SF | $ - 0 | $ - 0 |
| 1001AB48 | Asbestos Hazardous Control Activities | 50 | SF | $ - 0 | $ - 0 |
| 1001AB49 | Asbestos Testing | 80 | EA | $ - 0 | $ - 0 |
| 1001AB50 | Roofing Panels (metal or copper) | 10,000 | SF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 1001AB (CLINS 1001AB01 THRU 1001AB50) | $ - 0 | ||||
| SUB CLIN 1001AC - METALS for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Square Feet (SF), Each (EA), Pound (LB), Linear Feet (LF), One-vertical step up on stair (RISER), or Vertical Linear Feet (VLF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 05500, Metals, Miscellaneous or Fabrications for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 1001AC | METALS | |||||
| 1001AC01 | Roof decking, open type B wide rib, galv. 3" deep, 22 gauge under 50 squares | 100 | SF | $ - 0 | $ - 0 | |
| 1001AC02 | Roof decking, open type B wide rib, galv. 3" deep, 18 gauge under 50 squares | 100 | SF | $ - 0 | $ - 0 | |
| 1001AC03 | Roof decking, end closures | 50 | LF | $ - 0 | $ - 0 | |
| 1001AC04 | 7/8" corrigated roof decking, flexible closurestrip | 100 | LF | $ - 0 | $ - 0 | |
| 1001AC05 | Lintels, plain steel angles, shop fabricated, under 500 lb | 50 | LB | $ - 0 | $ - 0 | |
| 1001AC06 | Lintels, plain steel angles, shop fabricated, under 500 to 1000 lb | 50 | LB | $ - 0 | $ - 0 | |
| 1001AC07 | Steel plates (for antennas and microwave dishes), shop fabricated, 1" thick (40.8 lb/sf) | 50 | SF | $ - 0 | $ - 0 | |
| 1001AC08 | Lightweight Framing, angle framing, field fabricated, 4" and larger | 40 | LB | $ - 0 | $ - 0 | |
| 1001AC09 | Lightweight Framing, angle framing, field fabricated, 1" x 1" x 1/8" | 75 | LF | $ - 0 | $ - 0 | |
| 1001AC10 | Lightweight Framing, angle framing, field fabricated, 2" x 2" x 1/4" | 75 | LF | $ - 0 | $ - 0 | |
| 1001AC11 | Lightweight Framing, structural zee framing, field fabricated, 3-1/4" x 5" x 3-1/4" | 50 | LF | $ - 0 | $ - 0 | |
| 1001AC12 | Lightweight Framing, channel framing, field fabricated, C2 x 1.78 | 50 | LF | $ - 0 | $ - 0 | |
| 1001AC13 | Vertical Metal Ladder, shop fabricated steel, 20" wide, bolted to concrete, without cage. (Extend ladder 3'-6" above roof/parapet wall.) | 10 | VLF | $ - 0 | $ - 0 | |
| 1001AC14 | Vertical Metal Ladder, shop fabricated aluminum, bolted to concrete, without cage. | |||||
| (Extend ladder 3'-6" above roof/parapet wall.) | 10 | VLF | $ - 0 | $ - 0 | ||
| 1001AC15 | Railings, Industrial, welded, shop fabricated, 2 rail, posts 5' o.c., 3'-6" high, 1-1/2" pipe | 28 | LF | $ - 0 | $ - 0 | |
| 1001AC16 | Railings, Industrial, welded, shop fabricated, 2 rail, on stairs, primed, 1-1/2" diameter | 28 | LF | $ - 0 | $ - 0 | |
| 1001AC17 | Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 3'-6" wide | 20 | RISER | $ - 0 | $ - 0 | |
| 1001AC18 | Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 4'-0" wide | 20 | RISER | $ - 0 | $ - 0 | |
| 1001AC19 | Permanent U-Bolt roof anchor | 25 | EA | $ - 0 | $ - 0 | |
| 1001AC20 | Temporary (one use) U-Bolt roof anchor | 12 | EA | $ - 0 | $ - 0 | |
| 1001AC21 | Coping, stock units, aluminum, for 12" wall | 250 | LF | $ - 0 | $ - 0 | |
| TOTAL AMOUNT FOR SUB CLIN 1001AC (CLINS 1001AC01 THRU 1001AC21) | $ - 0 | |||||
| SUB CLIN 1001AD - WOOD AND PLASTIC for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Linear Feet (LF), Thousand Board Feet (MBF), Square Feet of Floor (SF FL), or Square Feet (SF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 06100A, Rough Carpentry and Section 06200A, Finish Carpentry, for all existing and previously roofed buildings or buildings with expired roof warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 1001AD | WOOD AND PLASTIC | ||||
| 1001AD01 | Misc. Framing, nailers, treated, wood construction, 2" x 4", pneumatic nailed | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD02 | Misc. Framing, nailers, treated, steel constr, 2" x 4", pneumatic nailed | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD03 | Roof Framing, ridge board, #2 or better, 1" x 6" | 10 | MBF | $ - 0 | $ - 0 |
| 1001AD04 | Roof Framing, ridge board, #2 or better, 2" x 8" | 10 | MBF | $ - 0 | $ - 0 |
| 1001AD05 | Wood framing, Sleepers, on concrete, treated, 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD06 | Wood Framing, soffits & canopies, canopies or soffit framing, 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD07 | Sheathing, Plywood on roof, CDX, 3/4" thick, pneumatic nailed | 2,000 | SF | $ - 0 | $ - 0 |
| 1001AD08 | Sheathing, gypsum, weatherproof, 1/2" thick | 1,000 | SF | $ - 0 | $ - 0 |
| 1001AD09 | Sheathing, wood fiber, regular, no vapor barrier, 5/8" thick | 1,000 | SF | $ - 0 | $ - 0 |
| 1001AD10 | Roof Framing, fascia boards, 2" x 8" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD11 | Soffits, exterior AC plywood, 1/2" thick | 200 | SF | $ - 0 | $ - 0 |
| 1001AD12 | Rafter extension (tails), 2" x 6" ordinary | 200 | LF | $ - 0 | $ - 0 |
| 1001AD13 | Rafter extension (tails), 2" x 8" ordinary | 200 | LF | $ - 0 | $ - 0 |
| 1001AD14 | Laminated Roof Deck, cedar, 3" thick | 200 | SF | $ - 0 | $ - 0 |
| 1001AD15 | Laminated Roof Deck, cedar, 4" thick | 200 | SF | $ - 0 | $ - 0 |
| 1001AD16 | Blocking, miscellaneous, to wood construction 2" x 4", Pneumatic Nailed | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD17 | Blocking, miscellaneous, to wood construction 2" x 8", Pneumatic Nailed | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD18 | Blocking, miscellaneous, to steel construction 2" x 4" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD19 | Blocking, miscellaneous, to steel construction 2" x 8" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AD20 | Plywood, underlayment grade, 1/2" thick, pneumatic nailed | 100 | SF FLR | $ - 0 | $ - 0 |
| 1001AD21 | Plywood, underlayment grade, 3/4" thick, pneumatic nailed | 100 | SF SFR | $ - 0 | $ - 0 |
| 1001AD22 | Oriented Strand Board, underlayment grade, 0.225 inch thick | 10 | MBF | $ - 0 | $ - 0 |
| TOTAL AMOUNT FOR SUB CLIN 1001AD (CLINS 1001AD01 THRU 1001AD22) | $ - 0 | ||||
| SUB CLIN 1001AE - THERMAL & MOISTURE PROTECTION of buildings, warehouses, structures, & miscellaneous facilities shall be measured by units of Square or 100 square feet (SQ), Linear Feet (LF), Board Foot (BF), Square Feet, an area 12"x12" (SF), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications. |
NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Board & Block Insulation, thru Section 07920, Joint Sealants, for all previously roofed buildings, or new buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.
| 1001AE | THERMAL & MOISTURE PROTECTION | ||||
| 1001AE01 | Roof Curb, untreated, 2" x 6" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AE02 | Roof Cant, split 4" x 4" | 2 | MBF | $ - 0 | $ - 0 |
| 1001AE03 | Roof Curb, untreated, 2" x 12" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AE04 | Roof Cant, split 6" x 6" | 1 | MBF | $ - 0 | $ - 0 |
| 1001AE05 | BUR, asph. Flood coat, smooth surface, 4 plies #15 asphalt felt, mopped, on nailable decks | 200 | SQ | $ - 0 | $ - 0 |
| 1001AE06 | BUR, asph. Flood coat, smooth surface, 4 plies #15 organic felt, mopped | 200 | SQ | $ - 0 | $ - 0 |
| 1001AE07 | APP modified bituminous membrane, Granule surface cap sheet, poly. Reinf., torched 180 mils | 1,000 | SF | $ - 0 | $ - 0 |
| 1001AE08 | APP modified bituminous membrane, Granule surface flashing, torched, 180 mils | 10,000 | SF | $ - 0 | $ - 0 |
| 1001AE09 | Asphalt Shingles, premium, laminated multi-layered shingles, Class A, 260-300 lb, 4 bundles/sq, pneumatic nailed | 100 | SQ | $ - 0 | $ - 0 |
| 1001AE10 | Self adhering polyethylene and rubberized asphalt underlayment | 100 | SQ | $ - 0 | $ - 0 |
| 1001AE11 | Asphalt ridge shingles, pneumatic nailed | 1,000 | LF | $ - 0 | $ - 0 |
| 1001AE12 | Clay Tile, access included, ASTM C1167, Spanish tile, red (Clay tile, remove same, salvage, reinstall same tile) | 4,000 | SF | $ - 0 | $ - 0 |
| 1001AE13 | Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., fully adhered with adhesive (single ply membrane) | 100 | SQ | $ - 0 | $ - 0 |
| 1001AE14 | Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., loose-laid & ballasted with stone/gravel (12 PSF) single ply membrane | 100 | SQ | $ - 0 | $ - 0 |
| 1001AE15 | Cant, 4" x 4" foamglass | 5,000 | LF | $ - 0 | $ - 0 |
| 1001AE16 | Asphalt felt, #30, 2 sq per roll | 100 | SQ | $ - 0 | $ - 0 |
| 1001AE17 | Ridge Vent, Alum., strips, Painted finish | 500 | LF | $ - 0 | $ - 0 |
| 1001AE18 | Ridge Vent, Alum., end caps | 20 | EA | $ - 0 | $ - 0 |
This is the start of the file's text. The full file is on GovTribe.
Other files for this federal contract opportunity
Show all 46
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .