FA3047-10-R-0012 Atch 1

114 KB Posted

Attached to
Roofing Indefinite Delivery Indefinite Quantity (IDIQ) Federal contract opportunity
Solicitation number
FA3047-10-R-0012-ROOFING
Issued by
Department of the Air Force Air Education and Training Command

About this file

FA3047-10-R-0012 Atch 1 (Bid Schedules) 10 May 10

Text of this file

Basic Year

OFFEROR'S PLEASE TYPE YOUR COMPANY NAME HEREOriginal
CLIN 0001 - BASIC YEAR. CONTRACTOR SHALL FURNISH ALL PLANT, LABOR, MATERIALS AND EQUIPMENT, AND PERFORM ALL WORK IN CONTRACT SPECIFICATIONS AND SUBMITTAL REQUIREMENTS IN ACCORDANCE WITH THE TERMS AND CONDITIONS SET FORTH IN THE PERFORMANCE PERIOD IS 365 CALENDAR DAYS BEGINNING THE DAY OF CONTRACT AWARD. THE MAXIMUM AMOUNT THAT MAY BE ORDERED UNDER THIS CONTRACT IS $10,000,000.00 (CEILING). THE GUARANTEED MINIMUM AMOUNT IS $5,000.00 FOR THE LIFE OF THE CONTRACT.
ITEM
NOWORK ELEMENTSEST
QTYUNIT OF MEASUREUNIT
PRICEEXTENDED

AMOUNT

SUB CLIN 0001AA - GENERAL REQUIREMENTS of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of Inches (IN), Square Feet (SF), or Hours (HR), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, GENERAL REQUIREMENTS, SECTIONS 00900, Project Information, thru SECTION 01330, Submittal Procedures, for all previously roofed buildings and exposed surfaces of new buildings, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction. All line items are exact quantities or inclusive. Material waste and usage shall be included in the unit price. Separate payment or increase in units for material waste will not be allowed.

0001AAGENERAL REQUIREMENTS
0001AA01Quality Control, testing, core drilling, 4" dia. Core, up to 6" thick slab including bit, layout and set-up200IN$ - 0$ - 0
0001AA02Quality Control, testing, leak investigation, infrared imager, copy of report to CO20SF$ - 0$ - 0
0001AA03Quality Control, testing existing roofs for water leaks20HR$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AA (CLINS 0001AA01 THRU 0001AA03)$ - 0
SUB CLIN 0001AB - DEMOLITION for roof structures, portions of existing roofs, and miscellaneous facilities shall be measured in units of Square Feet (SF), Board Foot = 12"x12"x1" area of wood (BF), Square = 100 square foot area (SQ), Linear Feet (LF), Cubic Yard (CY), Ton (TON), Loose Cubic Yard (LCY), Week = 5-working days (WK), Day = 8 hours or 0730-1630 hours (Day), Month = 22-days average (Month), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide demolition work as specified in the specifications, SECTIONS 02220, Demolition THRU SECTION 02922, Siding, for all previously roofed buildings, and buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001ABDEMOLITION
0001AB01Roofing, built-up, up to 4 ply roof, including gravel1,250SQ$ - 0$ - 0
0001AB02Gravel removal, minimum10,000SF$ - 0$ - 0
0001AB03Gravel removal, maximum100SQ$ - 0$ - 0
0001AB04Asphalt shingles, 1 layer20,000SF$ - 0$ - 0
0001AB05Roofing, felt paper, #30 felt100SQ$ - 0$ - 0
0001AB06Roll roofing, cold adhesive100SQ$ - 0$ - 0
0001AB07Sheathing from roof 1/2"5,000SF$ - 0$ - 0
0001AB08Sheathing from roof 3/4"10,000SF$ - 0$ - 0
0001AB09Board sheathing from roof5,000SF$ - 0$ - 0
0001AB10Saw cutting, sheathing to 1" thick, on room500LF$ - 0$ - 0
0001AB11Roof insulation board, up to 2" thick10,000SF$ - 0$ - 0
0001AB12Roof insulation board, over 2" thick5,000BF$ - 0$ - 0
0001AB13Wall framing, including studs, plates, and blocking, 2" x 4"300SF$ - 0$ - 0
0001AB14Wall framing, including studs, plates, and blocking, 2" x 6"100SF$ - 0$ - 0
0001AB15Fascia boards, 1" x 8"1,000LF$ - 0$ - 0
0001AB16Fascia boards, 2" x 8"1,000LF$ - 0$ - 0
0001AB17Soffit, T & G wood100SF$ - 0$ - 0
0001AB18Soffit, T & G Plywood100SF$ - 0$ - 0
0001AB19Conduct 8 metal TCLP test15EA$ - 0$ - 0
0001AB20Personal sampling, PCM analysis, NIOSH 74008EA$ - 0$ - 0
0001AB21Dumpster, weekly rental, 1 dump/week, 20 C.Y. capacity (8 tons)40WK$ - 0$ - 0
0001AB22Haul, per mile, up to 8 C.Y. truck2,000CY$ - 0$ - 0
0001AB23Dump charges, typical urban city, tipping fees only, bldg construction materials100TON$ - 0$ - 0
0001AB24Floor protection @ bore hole area500EA$ - 0$ - 0
0001AB25Remove & reinstall roof exhaust fan, vent/exhaust fan hook-up, EMT & wire40EA$ - 0$ - 0
0001AB26Flashing and sheet metal2,500SF$ - 0$ - 0
0001AB27Roof accessories, plumbing vent flashing100EA$ - 0$ - 0
0001AB28Roof accessories, skylight to 10 S.F.45EA$ - 0$ - 0
0001AB29Gutters, aluminum, edge hung1,000LF$ - 0$ - 0
0001AB30Downspouts, including hangers1,000LF$ - 0$ - 0
0001AB31Sheet metal coping, up to 12" wide1,500LF$ - 0$ - 0
0001AB32Concrete coping, up to 12" wide1,000LF$ - 0$ - 0
0001AB33Gravel Stop3,000LF$ - 0$ - 0
0001AB34Ridge vent strip, aluminum300LF$ - 0$ - 0
0001AB35Ridge shingles, clay300LF$ - 0$ - 0
0001AB36Soffit vent strip, aluminum, 3" - 4" wide600LF$ - 0$ - 0
0001AB37Soffit vent strip and/or fascia vent100LF$ - 0$ - 0
0001AB38Cant strip5,000LF$ - 0$ - 0
0001AB39Single ply membrane, ballasted100SQ$ - 0$ - 0
0001AB40Single ply membrane, fully adhered100SQ$ - 0$ - 0
0001AB41All-terrain forklift, 45' lift, 35' reach, 9000 lb. capacity10Month$ - 0$ - 0
0001AB4212-ton truck-mounted hydraulic crane10Day$ - 0$ - 0
0001AB43Selective Mech. Demolition, vent flashing & caps1,000EA$ - 0$ - 0
0001AB44Exterior Surface Preparation, siding, scrape and sand, medium1,000SF$ - 0$ - 0
0001AB45Exterior Surface Preparation, siding, scrape and sand, heavy1,000SF$ - 0$ - 0
0001AB46Selective Demo Wood Framing, Hardboard, Vinyl or Aluminum Soffit500SF$ - 0$ - 0
0001AB47Sanding, Surface Preparation, placement and removal, basic drop cloths500SF$ - 0$ - 0
0001AB48Asbestos Hazardous Control Activities50SF$ - 0$ - 0
0001AB49Asbestos Testing80EA$ - 0$ - 0
0001AB50Roofing Panels (metal or copper)10,000SF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AB (CLINS 0001AB01 THRU 0001AB50)$ - 0
SUB CLIN 0001AC - METALS for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Square Feet (SF), Each (EA), Pound (LB), Linear Feet (LF), One-vertical step up on stair (RISER), or Vertical Linear Feet (VLF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 05500, Metals, Miscellaneous or Fabrications for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001ACMETALS
0001AC01Roof decking, open type B wide rib, galv. 3" deep, 22 gauge under 50 squares1,000SF$ - 0$ - 0
0001AC02Roof decking, open type B wide rib, galv. 3" deep, 18 gauge under 50 squares1,000SF$ - 0$ - 0
0001AC03Roof decking, end closures100LF$ - 0$ - 0
0001AC047/8" corrugated roof decking, flexible closure strip100LF$ - 0$ - 0
0001AC05Lintels, plain steel angles, shop fabricated, under 500 lb50LB$ - 0$ - 0
0001AC06Lintels, plain steel angles, shop fabricated, under 500 to 1000 lb50LB$ - 0$ - 0
0001AC07Steel plates (for antennas and microwave dishes), shop fabricated, 1" thick (40.8 lb/sf)50SF$ - 0$ - 0
0001AC08Lightweight Framing, angle framing, field fabricated, 4" and larger40LB$ - 0$ - 0
0001AC09Lightweight Framing, angle framing, field fabricated, 1" x 1" x 1/8"75LF$ - 0$ - 0
0001AC10Lightweight Framing, angle framing, field fabricated, 2" x 2" x 1/4"75LF$ - 0$ - 0
0001AC11Lightweight Framing, structural zee framing, field fabricated, 3-1/4" x 5" x 3-1/4"50LF$ - 0$ - 0
0001AC12Lightweight Framing, channel framing, field fabricated, C2 x 1.7850LF$ - 0$ - 0
0001AC13Vertical Metal Ladder, shop fabricated steel, 20" wide, bolted to concrete, without cage. (Extend ladder 3'-6" above roof/parapet wall.)10VLF$ - 0$ - 0
0001AC14Vertical Metal Ladder, shop fabricated aluminum, bolted to concrete, without cage.
(Extend ladder 3'-6" above roof/parapet wall.)10VLF$ - 0$ - 0
0001AC15Railings, Industrial, welded, shop fabricated, 2 rail, posts 5' o.c., 3'-6" high, 1-1/2" pipe28LF$ - 0$ - 0
0001AC16Railings, Industrial, welded, shop fabricated, 2 rail, on stairs, primed, 1-1/2" diameter28LF$ - 0$ - 0
0001AC17Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 3'-6" wide20RISER$ - 0$ - 0
0001AC18Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 4'-0" wide20RISER$ - 0$ - 0
0001AC19Permanent U-Bolt roof anchor25EA$ - 0$ - 0
0001AC20Temporary (one use) U-Bolt roof anchor12EA$ - 0$ - 0
0001AC21Coping, stock units, aluminum, for 12" wall250LF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AC (CLINS 0001AC01 THRU 0001AC21)$ - 0
SUB CLIN 0001AD - WOOD AND PLASTIC for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Linear Feet (LF), Thousand Board Feet (MBF), Square Feet of Floor (SF FL), or Square Feet (SF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 06100A, Rough Carpentry and Section 06200A, Finish Carpentry, for all existing and previously roofed buildings or buildings with expired roof warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001ADWOOD AND PLASTIC
0001AD01Misc. Framing, nailers, treated, wood construction, 2" x 4", pneumatic nailed1MBF$ - 0$ - 0
0001AD02Misc. Framing, nailers, treated, steel construction, 2" x 4", pneumatic nailed1MBF$ - 0$ - 0
0001AD03Roof Framing, ridge board, #2 or better, 1" x 6"10MBF$ - 0$ - 0
0001AD04Roof Framing, ridge board, #2 or better, 2" x 8"10MBF$ - 0$ - 0
0001AD05Wood framing, Sleepers, on concrete, treated, 2" x 4"1MBF$ - 0$ - 0
0001AD06Wood Framing, soffits & canopies, canopies or soffit framing, 2" x 4"1MBF$ - 0$ - 0
0001AD07Sheathing, Plywood on roof, CDX, 3/4" thick, pneumatic nailed2,000SF$ - 0$ - 0
0001AD08Sheathing, gypsum, weatherproof, 1/2" thick1,000SF$ - 0$ - 0
0001AD09Sheathing, wood fiber, regular, no vapor barrier, 5/8" thick1,000SF$ - 0$ - 0
0001AD10Roof Framing, fascia boards, 2" x 8"1MBF$ - 0$ - 0
0001AD11Soffits, exterior AC plywood, 1/2" thick200SF$ - 0$ - 0
0001AD12Rafter extension (tails), 2" x 6" ordinary200LF$ - 0$ - 0
0001AD13Rafter extension (tails), 2" x 8" ordinary200LF$ - 0$ - 0
0001AD14Laminated Roof Deck, cedar, 3" thick200SF$ - 0$ - 0
0001AD15Laminated Roof Deck, cedar, 4" thick200SF$ - 0$ - 0
0001AD16Blocking, miscellaneous, to wood construction 2" x 4", Pneumatic Nailed1MBF$ - 0$ - 0
0001AD17Blocking, miscellaneous, to wood construction 2" x 8", Pneumatic Nailed1MBF$ - 0$ - 0
0001AD18Blocking, miscellaneous, to steel construction 2" x 4"1MBF$ - 0$ - 0
0001AD19Blocking, miscellaneous, to steel construction 2" x 8"1MBF$ - 0$ - 0
0001AD20Plywood, underlayment grade, 1/2" thick, pneumatic nailed100SF FLR$ - 0$ - 0
0001AD21Plywood, underlayment grade, 3/4" thick, pneumatic nailed100SF SFR$ - 0$ - 0
0001AD22Oriented Strand Board, underlayment grade, 0.225 inch thick10MBF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AD (CLINS 0001AD01 THRU 0001AD22)$ - 0
SUB CLIN 0001AE - THERMAL & MOISTURE PROTECTION of buildings, warehouses, structures, & miscellaneous facilities shall be measured by units of Square or 100 square feet (SQ), Linear Feet (LF), Board Foot (BF), Square Feet, an area 12"x12" (SF), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Board & Block Insulation, thru Section 07920, Joint Sealants, for all previously roofed buildings, or new buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001AETHERMAL & MOISTURE PROTECTION
0001AE01Roof Curb, untreated, 2" x 6"1MBF$ - 0$ - 0
0001AE02Roof Cant, split 4" x 4"2MBF$ - 0$ - 0
0001AE03Roof Curb, untreated, 2" x 12"1MBF$ - 0$ - 0
0001AE04Roof Cant, split 6" x 6"1MBF$ - 0$ - 0
0001AE05BUR, asph. Flood coat, smooth surface, 4 plies #15 asphalt felt, mopped, on nailable decks200SQ$ - 0$ - 0
0001AE06BUR, asph. Flood coat, smooth surface, 4 plies #15 organic felt, mopped200SQ$ - 0$ - 0
0001AE07APP modified bituminous membrane, Granule surface cap sheet, poly. Reinf., torched 180 mils1,000SF$ - 0$ - 0
0001AE08APP modified bituminous membrane, Granule surface flashing, torched, 180 mils10,000SF$ - 0$ - 0
0001AE09Asphalt Shingles, premium, laminated multi-layered shingles, Class A, 260-300 lb, 4 bundles/sq, pneumatic nailed100SQ$ - 0$ - 0
0001AE10Self adhering polyethylene and rubberized asphalt underlayment100SQ$ - 0$ - 0
0001AE11Asphalt ridge shingles, pneumatic nailed1,000LF$ - 0$ - 0
0001AE12Clay Tile, access included, ASTM C1167, Spanish tile, red (Clay tile, remove same, salvage, reinstall same tile)4,000SF$ - 0$ - 0
0001AE13Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., fully adhered with adhesive (single ply membrane)100SQ$ - 0$ - 0
0001AE14Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., loose-laid & ballasted with stone/gravel (12 PSF) single ply membrane100SQ$ - 0$ - 0
0001AE15Cant, 4" x 4" foam glass5,000LF$ - 0$ - 0
0001AE16Asphalt felt, #30, 2 sq per roll100SQ$ - 0$ - 0
0001AE17Ridge Vent, Alum., strips, Painted finish500LF$ - 0$ - 0
0001AE18Ridge Vent, Alum., end caps20EA$ - 0$ - 0
0001AE19Roof deck insulation, perlite, 3/4" thick R2.085,000SF$ - 0$ - 0
0001AE20Roof deck Insulation, polyisocyanurate, 2#/CF density, 1.5" thick5,000SF$ - 0$ - 0
0001AE21Roof deck Insulation, polyisocyanurate, 2#/CF density, 2" thick20,000SF$ - 0$ - 0
0001AE22Roof deck Insulation, polyisocyanurate, 2#/CF density, 2-1/2" thick10,000SF$ - 0$ - 0
0001AE23Roof deck Insulation, polyisocyanurate, 2#/CF density, 3" thick10,000SF$ - 0$ - 0
0001AE24Steel Roofing Panels, Flat profile, 1-3/4" standing seams, 12" wide, standard finish, 26 gauge1,000SF$ - 0$ - 0
0001AE25Steel Roofing Panels, Flat profile, 1-3/4" standing seam, 12" wide, standard finish, 24 gauge5,000SF$ - 0$ - 0
0001AE26Steel Roofing Panels, Ridge, galvanized, 10" wide1,000LF$ - 0$ - 0
0001AE27Roof Deck Insulation, Polyisocyanurate tapered for drainage1,000BF$ - 0$ - 0
0001AE28Soffit, baked enamel on steel, 16 or 18 gauge, color300SF$ - 0$ - 0
0001AE29Gutters, Stainless Steel, half round or box, stock, 5" wide500LF$ - 0$ - 0
0001AE30Gutters, Steel, galv, half round or box, 26 gauge, stock, 5' wide100LF$ - 0$ - 0
0001AE31Gutters, Steel galv, half round or box, 26 gauge, stock, 6" wide100LF$ - 0$ - 0
0001AE32Gutter guard, 6" wide, aluminum mesh1,000LF$ - 0$ - 0
0001AE33Sheet metal flashing and counter flashing, including up to four bends, aluminum, mastic coated 2 sides, .016" thick300SF$ - 0$ - 0
0001AE34Sheet metal flashing and counter flashing, including up to four bends, aluminum, mill finish, .032" thick300SF$ - 0$ - 0
0001AE35Sheet metal flashing and counter flashing, aluminum mill finish, 12" x 12" step flashing, 0.016" thick250EA$ - 0$ - 0
0001AE36Sheet metal flashing and counter flashing, steel sheets, galvanized, 20 gauge250SF$ - 0$ - 0
0001AE37Sheet metal flashing and counter flashing, copper, 20 oz sheets, under 1000 lbs1,250SF$ - 0$ - 0
0001AE38Sheet metal flashing and counter flashing, copper, 20 oz sheets, over 4000 lbs2,250SF$ - 0$ - 0
0001AE39Sheet metal flashing and counter flashing, copper W shape for valleys, 16 oz, 24" wide100LF$ - 0$ - 0
0001AE40Downspouts, steel, galvanized, round, corrugated, 5" diameter, 26 gauge100LF$ - 0$ - 0
0001AE41Downspouts, steel, galvanized, round, corrugated, 6" diameter, 26 gauge100LF$ - 0$ - 0
0001AE42Pre-Finish Gutters, 5" x 6" including bends and clips for complete usable system100LF$ - 0$ - 0
0001AE43Gutters, Alum., stock units, 5" K type, .032" thick, enameled100LF$ - 0$ - 0
0001AE44Gutters, copper, half round, 16 oz., stock unit, 4" wide100LF$ - 0$ - 0
0001AE45Gutters, copper, half round, 16 oz., stock unit, 6" wide100LF$ - 0$ - 0
0001AE46Downspouts, lead-coated copper, round, stock, 4" Dia.10LF$ - 0$ - 0
0001AE47Downspouts, lead-coated copper, round, stock, 6" Dia.10LF$ - 0$ - 0
0001AE48Elbows, 90 degrees Elbows, PVC, 4" Dia.5EA$ - 0$ - 0
0001AE49Elbows, copper, solder joints, copper x copper, 4"1EA$ - 0$ - 0
0001AE50Cellular Glass Boards, Type IV500SF$ - 0$ - 0
0001AE51Drip Edge, Aluminum, .016" thick, 5" wide, mill finish100LF$ - 0$ - 0
0001AE52Drip Edge, Aluminum, .016" thick, 8" wide, mill finish100LF$ - 0$ - 0
0001AE53Drip Edge, Aluminum, .016" thick, vented, mill finish100LF$ - 0$ - 0
0001AE54Drip Edge, galvanized, 5" wide100LF$ - 0$ - 0
0001AE55Drip Edge, galvanized, 8" wide100LF$ - 0$ - 0
0001AE56Gravel Stop, galv. Steel, 24 gauge., 4" leg, plain, w/cont. cleat, 6" face100LF$ - 0$ - 0
0001AE57Gravel Stop, stainless steel, 24 gauge., 6" face height100LF$ - 0$ - 0
0001AE58Reglet, aluminum, .025" thick, in concrete parapet10LF$ - 0$ - 0
0001AE59Reglet, copper, 10 oz, in concrete parapet10LF$ - 0$ - 0
0001AE60Reglet, galv. Steel, 24 gauge., in concrete parapet1LF$ - 0$ - 0
0001AE61Reglet, stainless steel, .020" thick, in concrete parapet1LF$ - 0$ - 0
0001AE62Reglet, polyvinyl chloride, Type II, Grade I, Class 14333-D, .075" minimum thickness (temp construction)1LF$ - 0$ - 0
0001AE63Reglet, counter flashing for above, 12" wide, stainless steel, .020" thick1LF$ - 0$ - 0
0001AE64Reglet, counter flashing for above, 12" wide, copper, 10 oz.300LF$ - 0$ - 0
0001AE65Reglet, counter flashing for above, 12" wide, aluminum .032"300LF$ - 0$ - 0
0001AE66Reglet, counter flashing for above, 12" wide, galvanized steel, .020" thick100LF$ - 0$ - 0
0001AE67Expansion Jt., butyl or neoprene center with foam insulation, metal flanges, lead-coated copper, 16 oz. for opng to 2-1/2''250LF$ - 0$ - 0
0001AE68Expansion Jt., butyl or neoprene center with foam insulation, metal flanges, lead-coated copper, 16 oz. for opening to 5"100LF$ - 0$ - 0
0001AE69Expansion Jt., wall joint, closed cell foam on PVC cover, 12" wide300LF$ - 0$ - 0
0001AE70Expansion Jt., roof joint with extruded aluminum cover, 2"100LF$ - 0$ - 0
0001AE71Expansion Jt., roof joint with extruded aluminum cover100LF$ - 0$ - 0
0001AE72Roof vent mushroom for built-Up roofs, alum., (1-1/2" plumbing vents)30EA$ - 0$ - 0
0001AE73Walkway, for BUR, asphalt impregnated, 3' x 6' x 1/2" thick400SF$ - 0$ - 0
0001AE74Walkway, for BUR, concrete patio blocks, 2" thick, natural100SF$ - 0$ - 0
0001AE75Bentonite Waterproofing, Granular Bentonite, 3/8" thick, troweled on100SF$ - 0$ - 0
0001AE76Cementitious Waterproofing, one coat cement base, 1/8" application, spray-on100SF$ - 0$ - 0
0001AE77Backer rod, polyethylene, 1/2" diameter10CLF$ - 0$ - 0
0001AE78Backer rod, polyethylene, 1" diameter10CLF$ - 0$ - 0
0001AE79Downspout Boot, 12 gauge, G90, with receiving bell, 6'10EA$ - 0$ - 0
0001AE80Water Repellents, water base liquid, roller applied100SF$ - 0$ - 0
0001AE81Water Repellents, silicone or separate, sprayed on CMU, 2 coats100SF$ - 0$ - 0
0001AE82Clips for Standing Seam Metal Panels500EA$ - 0$ - 0
0001AE83Cont. Gravel Guard Clip1,000EA$ - 0$ - 0
0001AE84Laminated Sheet Flashing, including up to 4 bends, Lead-coated copper, fabric-backed, 2 oz.100SF$ - 0$ - 0
0001AE85Laminated Sheet Flashing, including up to 4 bends, Lead-coated copper, fabric-backed, 5 oz.100SF$ - 0$ - 0
0001AE86Laminated Sheet Flashing, including up to 4 bends, Lead on copper and fabric, 7 oz.100SF$ - 0$ - 0
0001AE87Rigid Insulation, for walls, fiberglass, 1.5#/CF, unfaced,1" thick, R4.1100SF$ - 0$ - 0
0001AE88Rigid Insulation, for walls, fiberglass, 1.5#/CF, unfaced, 3" thick, R12.41,000SF$ - 0$ - 0
0001AE89Rigid Insulation, for walls, expanded polystyrene, 1" thick, R3.85100SF$ - 0$ - 0
0001AE90Rigid Insulation, for walls, expanded polystyrene, 3" thick, R11.49100SF$ - 0$ - 0
0001AE91Gravel Stop, aluminum, .050" thick, 6" face height, duranodic finish (one-piece)100LF$ - 0$ - 0
0001AE92Gravel Stop, aluminum, .050" thick, 8" face height, duranodic finish (one-piece)100LF$ - 0$ - 0
0001AE93Gravel Stop, aluminum, .080" thick, 12" face height, duranodic finish (two-piece)100LF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AE (CLINS 0001AE01 THRU 0001AE93)$ - 0
SUB CLIN 0001AF - DOORS & WINDOWS of buildings, warehouses, structures and miscellaneous facilities and buildings/structures associated with them shall be measured in units of Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 08600, Skylights and SECTION 05500, Metals, Miscellaneous and Fabrications for all previously roofed buildings or new buildings with expired warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001AFDOORS & WINDOWS
0001AF01Roof Hatch, 2'-6" x 4'-6", Galvanized steel curb and aluminum cover5EA$ - 0$ - 0
0001AF02Vapor Retarders, polyethylene vapor barrier, standard, .006" thick50SQ$ - 0$ - 0
0001AF03Asphalt Roll Roofing, mineral surface for open valleys1,000LF$ - 0$ - 0
0001AF04Mineral Fiber Insulation Board200SF$ - 0$ - 0
0001AF05Skylight, plastic dome, ventilating insulated Plexiglas dome with curb mounting, 36" x 36"10EA$ - 0$ - 0
0001AF06Skylight, fiberglass panels, to 30 SF10EA$ - 0$ - 0
0001AF07Skylight, fiberglass panels, add for excess over 30 SF100SF$ - 0$ - 0
0001AF08Window Restoration - Silicone caulking at perimeter1,000LF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AF (CLINS 0001AF01 THRU 0001AF08)$ - 0
SUB CLIN 0001AG - FINISHES on buildings, garages, structures and miscellaneous facilities shall be measured in units of Square Foot (SF) or Linear Foot (LF), excluding elevated water storage tanks, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 09900, Paints and Coatings, for all previously roofed buildings or new buildings with expired warranties including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001AGFINISHES
0001AG01Walls & Ceilings, Interior, masonry or concrete block, silicone, water repellent, 2-coat, spray1,000SF$ - 0$ - 0
0001AG02Trim, Exterior, gutters & downspouts brushwork, metal, zinc chromate paint, 5", first coat300LF$ - 0$ - 0
0001AG03Trim, Exterior, gutters & downspouts brushwork, metal, zinc chromate paint, 5", second coat100LF$ - 0$ - 0
0001AG04Trim, Exterior, gutters & downspouts, brushwork, metal, zinc chromate paint, 5", third coat100LF$ - 0$ - 0
0001AG05Doors and Windows, Exterior, door frames & trim only, brushwork, primer & 2 coats, exterior latex100LF$ - 0$ - 0
0001AG06Trim, Exterior, fascia, latex paint, one coat coverage, 1" x 6" to 1" x 10" brushwork300LF$ - 0$ - 0
0001AG07Trim, Exterior, Molding, exterior, up to 14" wide, Brushwork, primer & 2 coats exterior latex300LF$ - 0$ - 0
0001AG08Wall coatings, epoxy coatings, minimum300SF$ - 0$ - 0
0001AG09Wall coatings, epoxy coatings, maximum100SF$ - 0$ - 0
0001AG10Exterior steel coatings, cold galvanizing, brush in field1,000SF$ - 0$ - 0
0001AG11Exterior steel coatings, paints & protective coatings, sprayed in field, alkyds, primer1,000SF$ - 0$ - 0
0001AG12Exterior steel coatings, paints & protective coatings, sprayed in field, alkyds, gloss topcoats1,000SF$ - 0$ - 0
0001AG13Exterior steel coatings, paints & protective coatings, sprayed in field, Latex primer1,000SF$ - 0$ - 0
0001AG14Exterior steel coatings, paints & protective coatings, sprayed in field, topcoats1,000SF$ - 0$ - 0
0001AG15Walls and Ceilings, Interior, concrete, drywall or plaster, oil base, paint 3 coats, smooth finish, brushwork (deduct 10% material cost for latex; for work 8' - 15' H, add 10% labor cost; for work over 15' H, add 20% labor cost)1,000SF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AG (CLINS 0001AG01 THRU 0001AG15)$ - 0
SUB CLIN 0001AH - ROOF MAINTENANCE & REPAIR of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of One Hundred or 100 in count (C), Linear Foot (LF), Each (EA), Square Foot (SF), Loose Cubic Yard (LCY), Bank Cubic Yard (BCY), Square (SQ = 100 square feet), or Cubic Foot (CF) excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Blanket & Block Insulation thru SECTION 07920, Joint Sealants for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001AHROOF MAINTENANCE & REPAIR
0001AH01Sheet metal (splash pan) copper, 24 oz. sheet, under 1000 lbs.50SF$ - 0$ - 0
0001AH02Sheet metal (splash pan) stainless steel sheets, 24 gauge, .025" thick30SF$ - 0$ - 0
0001AH03Sheet metal (splash pan, ridge/valley plates and flat copper roofing) steel sheets galvanized, 20 gauge100SF$ - 0$ - 0
0001AH04Remove existing caulking, clean opening and recaulk around all surfaces1,000LF$ - 0$ - 0
0001AH05Remove fill material from existing pitch pans entirely and refill with new pourable sealant material100EA$ - 0$ - 0
0001AH06Apply roof cement under loose shingle tabs1,000SF$ - 0$ - 0
0001AH07Remove and replace damaged shingles1,000SF$ - 0$ - 0
0001AH08Remove deteriorated steel Roof deck and replace with new matching steel roof deck1,000SF$ - 0$ - 0
0001AH09Remove & Reinstall lightning protection system (to include all necessary replacement components and reinstallation must be certifiable by the Underwriters Laboratories).1,000LF$ - 0$ - 0
0001AH10Rework steel roof panel. Lift panel sufficiently to allow working the lap without crimping the metal panel. Remove fasteners, sealant tape and caulking on exposed portion. Clean panel, apply new sealant tape, caulking and reinstall panel using new fasteners.100EA$ - 0$ - 0
0001AH11Coping, stock units, precast concrete, 10" wide, 4" tapers to 3-1/2", 8" wall100LF$ - 0$ - 0
0001AH12Coping, stock units, limestone for 12" wall, 4" thick200LF$ - 0$ - 0
0001AH13Furnish and install roof drain sleeve, including preparation of existing drain to receive the sleeve. Includes all necessary hardware and materials to form a functional drain100EA$ - 0$ - 0
0001AH14Cementitious Parging, 2 coats, 1/2" thick, waterproofed Portland Cement500SF$ - 0$ - 0
0001AH15Precast concrete splash block200EA$ - 0$ - 0
0001AH16Seal gutter with elastomeric membrane; 1/16" urethane troweled100SF$ - 0$ - 0
0001AH17Remove & replace screw fasteners, alum., self tapping, neoprene washers, 1"100C$ - 0$ - 0
0001AH18Line gutter with EPDM, 45 mils, fully adhered with adhesive100SF$ - 0$ - 0
0001AH19Elastomeric Waterproofing, 50 mil, reinforced, stucco texture, on horizontal or vertical surfaces100SF$ - 0$ - 0
0001AH20Elastomeric Sheet Waterproofing, EPDM, nylon reinforced sheets, 45 mils thick1,000SF$ - 0$ - 0
0001AH21Repair single ply roofing felt500SF$ - 0$ - 0
0001AH22Remove abandoned gas/water line, up thru 1-1/2" diameter100LF$ - 0$ - 0
0001AH23Repair blister on BUR, asphalt flood coat w/gravel-slag5,000SF$ - 0$ - 0
0001AH24Repair blister on BUR, tarred felts with coal tar pitch and gravel-slag2,500SF$ - 0$ - 0
0001AH25Repair Roof, mineral surface cap sheet1,000SF$ - 0$ - 0
0001AH26Repair modified bitumen roofing, SBS modified, smooth surface cap sheet, mopped1,000SF$ - 0$ - 0
0001AH27Repair stone coping, mortar, Type PM, 1:1:6 mix, 2500 psi10CF$ - 0$ - 0
0001AH28Roof Patch - BUR, asph flood coat, smooth surface, coated & saturated base sheet, 4-ply #15 asphalt felt, mopped, (Note - items for partial roof replacement only)10SQ$ - 0$ - 0
0001AH29Roof Patch - BUR, asph flood coat, smooth surface, coated & saturated base sheet, 4-ply #15 organic felt, mopped, (Note - items for partial roof replacement only)10SQ$ - 0$ - 0
0001AH30Remove & replace Roof Drain - Complete; (including demo, new drain, rework lead flashing, and patch roof)30EA$ - 0$ - 0
0001AH31Remove & reinstall new corrugated roof panel, on steel frame, painted, .032" thick25SF$ - 0$ - 0
0001AH32Lightning Protection, Air Terminals & base, copper, 3/8" dia x 10" (to 75' high)10EA$ - 0$ - 0
0001AH33Grounding, rod, copper clad, 10' long, 3/4" diameter10EA$ - 0$ - 0
0001AH34Lightning Protection, Arrester, 650 volt AC to ground10EA$ - 0$ - 0
0001AH35Remove/Raise & Reset Mechanical Equipment15EA$ - 0$ - 0
0001AH36Excavating, Trench, by hand with pick & shovel 2' to 6' deep, Heavy Soil10BCY$ - 0$ - 0
0001AH37Backfill, General, by hand, no compaction, heavy soil10LCY$ - 0$ - 0
0001AH38Restoring Low Slope Roofs - Restoration material (Equal to Mule-Hide Prod. Co. Inc., A-300 Finish)200SF$ - 0$ - 0
0001AH39Temporary Fencing, rented chain link, 6' high, to 1000' (up to 12 mo.)1,000LF$ - 0$ - 0
0001AH40Temporary Fencing, rented chain link, 6' high, over 1000' (up to 12 mo.)5,000LF$ - 0$ - 0
0001AH41Clay Tile, Replacement200SF$ - 0$ - 0
0001AH42Metal Panel Roof Repair/Replacement for more than 2.5%250SF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AH (CLINS 0001AH01 THRU 0001AH42)$ - 0
SUB CLIN 0001AI - ROOF ACCESSORIES on buildings, garages, structures and miscellaneous facilities shall be measured in units of Each (EA) or Linear Foot (LF), excluding elevated water storage tanks, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 09900, Paints and Coatings, for all previously roofed buildings or new buildings with expired warranties including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

0001AIROOF ACCESSORIES
0001AI01Vent caps, cast iron, 2-1/2" to 3-5/8" pipe100EA$ - 0$ - 0
0001AI02Vent caps, cast iron, 4" to 4-1/8" pipe100EA$ - 0$ - 0
0001AI03Vent flashing, aluminum with lead ring, 2" pipe100EA$ - 0$ - 0
0001AI04Vent flashing, aluminum with lead ring, 4" pipe100EA$ - 0$ - 0
0001AI05Vent flashing, copper with neoprene ring, 2" pipe100EA$ - 0$ - 0
0001AI06Vent flashing, copper with neoprene ring, 4" pipe100EA$ - 0$ - 0
0001AI07Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 6" diameter120LF$ - 0$ - 0
0001AI08Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 4" diameter120LF$ - 0$ - 0
0001AI09Sewage collection, PVC pipe, DWV, no excavation/backfill, 10' L, schedule 40, 8" diameter120LF$ - 0$ - 0
0001AI10Pipe, plastic, DWV type, schedule 40, couplings 10' o.c, clevis hanger assembly 3/10', ABS, schedule 40, foam core type, plain end black, 4" dia.120LF$ - 0$ - 0
0001AI11Pipe, plastic, DWV type, schedule 40, couplings 10' o.c, clevis hanger assembly, 3/10', ABS schedule 40, foam core type, plain end black, 6" dia.120LF$ - 0$ - 0
0001AI12Roof Drains, flat metal deck, C.I. body, 12" C.I. dome, 3" pipe size120LF$ - 0$ - 0
0001AI13Roof Drains, flat metal deck, C.I. body, 12" C.I. dome, 6" pipe size140LF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 0001AI (CLINS 0001AI01 THRU 0001AI13)$ - 0
SUB TOTAL AMOUNT FOR SUB CLINS:
0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH & 0001AI$ - 0
SUB CLIN 0001AJ - COMPENSATE TIME (Section 00 30 00, Paragraph 3) for work occurring in the AF ISR, TCC and WHMC areas, the Offeror shall include an additional "PERCENTAGE" mark-up to compensate the time delay in entering and exiting the secured areas and for working in a facility over 3-stories in height.

Note 1 (SOLICITATION): SUB CLIN 0001AJ will be applied to all BASIC YEAR SUB CLINS 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH & 0001AI in order to determine a TOTAL AMOUNT for the BASIC YEAR.

Note 2 (CONTRACT / DELIVERY ORDERS): SUB CLIN 0001AJ will be applied ONLY to BASIC YEAR Projects that meet the COMPENSATE TIME requirements.0.00%$ - 0
SUB TOTAL AMOUNT FOR SUB CLINS:
0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH / 0001AI & 0001AJ$ - 0
0001AKSUB CLIN 0001AK - CE SOFTWARE REQUIREMENTS
(Section 00 30 00, Paragraph 39.12.1). * Applicable only for Basic Year2EA$ - 0$ - 0
TOTAL AMOUNT FOR CLIN 0001 - BASIC YEAR:
SUB CLINS 0001AA / 0001AB / 0001AC / 0001AD / 0001AE / 0001AF / 0001AG / 0001AH / 0001AI / 0001AJ & 0001AK$ - 0

&"Times New Roman,Regular"&10 802 CONS/LGCA-3

Lackland AFB TX&"Times New Roman,Bold"ROOFING IDIQ CONTRACT
(BASIC YEAR)&"Times New Roman,Regular"&10FA3047-10-R-0012

10 May 10

&"Times New Roman,Regular"Section J - Attachment 1 &"Times New Roman,Bold""SOURCE SELECTION INFORMATION" &"Times New Roman,Regular"Page &P of &N

Option Year One

OFFEROR'S PLEASE TYPE YOUR COMPANY NAME HEREOriginal
CLIN 1001 - OPTION YEAR ONE. CONTRACTOR SHALL FURNISH ALL PLANT, LABOR, MATERIALS AND EQUIPMENT, AND PERFORM ALL WORK IN CONTRACT SPECIFICATIONS AND SUBMITTAL REQUIREMENTS IN ACCORDANCE WITH THE TERMS AND CONDITIONS SET FORTH IN THE PERFORMANCE PERIOD IS 365 CALENDAR DAYS BEGINNING THE DAY OF CONTRACT AWARD. THE MAXIMUM AMOUNT THAT MAY BE ORDERED UNDER THIS CONTRACT IS $10,000,000.00 (CEILING).
ITEM
NOWORK ELEMENTSEST
QTYUNIT OF MEASUREUNIT
PRICEEXTENDED

AMOUNT

SUB CLIN 1001AA - GENERAL REQUIREMENTS of buildings, warehouses, structures and miscellaneous facilities shall be measured in units of Inches (IN), Square Feet (SF), or Hours (HR), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, GENERAL REQUIREMENTS, SECTIONS 00900, Project Information, thru SECTION 01330, Submittal Procedures, for all previously roofed buildings and exposed surfaces of new buildings, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction. All line items are exact quantities or inclusive. Material waste and usage shall be included in the unit price. Separate payment or increase in units for material waste will not be allowed.

1001AAGENERAL REQUIREMENTS
1001AA01Quality Control, testing, core drilling, 4" dia. Core, up to 6" thick slab including bit, layout and set-up200IN$ - 0$ - 0
1001AA02Quality Control, testing, leak investigation, infrared imager, copy of report to CO20SF$ - 0$ - 0
1001AA03Quality Control, testing existing roofs for water leaks20HR$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 1001AA (CLINS 1001AA01 THRU 1001AA03)$ - 0
SUB CLIN 1001AB - DEMOLITION for roof structures, portions of existing roofs, and miscellaneous facilities shall be measured in units of Square Feet (SF), Board Foot = 12"x12"x1" area of wood (BF), Square = 100 square foot area (SQ), Linear Feet (LF), Cubic Yard (CY), Ton (TON), Loose Cubic Yard (LCY), Week = 5-working days (WK), Day = 8 hours or 0730-1630 hours (Day), Month = 22-days average (Month), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide demolition work as specified in the specifications, SECTIONS 02220, Demolition THRU SECTION 02922, Sodding, for all previously roofed buildings, and buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

1001ABDEMOLITION
1001AB01Roofing, built-up, up to 4 ply roof, including gravel1,250SQ$ - 0$ - 0
1001AB02Gravel removal, minimum10,000SF$ - 0$ - 0
1001AB03Gravel removal, maximum100SQ$ - 0$ - 0
1001AB04Asphalt shingles, 1 layer20,000SF$ - 0$ - 0
1001AB05Roofing, felt paper, #30 felt100SQ$ - 0$ - 0
1001AB06Roll roofing, cold adhesive100SQ$ - 0$ - 0
1001AB07Sheathing from roof 1/2"5,000SF$ - 0$ - 0
1001AB08Sheathing from roof 3/4"10,000SF$ - 0$ - 0
1001AB09Board sheathing from roof5,000SF$ - 0$ - 0
1001AB10Saw cutting, sheathing to 1" thick, on room500LF$ - 0$ - 0
1001AB11Roof insulation board, up to 2" thick10,000SF$ - 0$ - 0
1001AB12Roof insulation board, over 2" thick5,000BF$ - 0$ - 0
1001AB13Wall framing, including studs, plates, and blocking, 2" x 4"300SF$ - 0$ - 0
1001AB14Wall framing, including studs, plates, and blocking, 2" x 6"100SF$ - 0$ - 0
1001AB15Fascia boards, 1" x 8"1,000LF$ - 0$ - 0
1001AB16Fascia boards, 2" x 8"1,000LF$ - 0$ - 0
1001AB17Soffit, T & G wood100SF$ - 0$ - 0
1001AB18Soffit, T & G Plywood100SF$ - 0$ - 0
1001AB19Conduct 8 metal TCLP test15EA$ - 0$ - 0
1001AB20Personal sampling, PCM analysis, NIOSH 74008EA$ - 0$ - 0
1001AB21Dumpster, weekly rental, 1 dump/week, 20 C.Y. capacity (8 tons)40WK$ - 0$ - 0
1001AB22Haul, per mile, up to 8 C.Y. truck2,000CY$ - 0$ - 0
1001AB23Dump charges, typical urban city, tipping fees only, bldg constr matls100TON$ - 0$ - 0
1001AB24Floor protection @ bore hole area500EA$ - 0$ - 0
1001AB25Remove & reinstall roof exhaust fan, vent/exhaust fan hook-up, EMT & wire40EA$ - 0$ - 0
1001AB26Flashing and sheet metal2,500SF$ - 0$ - 0
1001AB27Roof accessories, plumbing vent flashing100EA$ - 0$ - 0
1001AB28Roof accessories, skylight to 10 S.F.45EA$ - 0$ - 0
1001AB29Gutters, aluminum, edge hung1,000LF$ - 0$ - 0
1001AB30Downspouts, including hangers1,000LF$ - 0$ - 0
1001AB31Sheet metal coping, up to 12" wide1,500LF$ - 0$ - 0
1001AB32Concrete coping, up to 12" wide1,000LF$ - 0$ - 0
1001AB33Gravel Stop3,000LF$ - 0$ - 0
1001AB34Ridge vent strip, aluminum300LF$ - 0$ - 0
1001AB35Ridge shingles, clay300LF$ - 0$ - 0
1001AB36Soffit vent strip, aluminum, 3" - 4" wide600LF$ - 0$ - 0
1001AB37Soffit vent strip and/or fascia vent100LF$ - 0$ - 0
1001AB38Cant strip5,000LF$ - 0$ - 0
1001AB39Single ply membrane, ballasted100SQ$ - 0$ - 0
1001AB40Single ply membrane, fully adhered100SQ$ - 0$ - 0
1001AB41All-terrain forklift, 45' lift, 35' reach, 9000 lb. capacity10Month$ - 0$ - 0
1001AB4212-ton truck-mounted hydraulic crane10Day$ - 0$ - 0
1001AB43Selective Mech. Demolition, vent flashing & caps1,000EA$ - 0$ - 0
1001AB44Exterior Surface Preparation, siding, scrape and sand, medium1,000SF$ - 0$ - 0
1001AB45Exterior Surface Preparation, siding, scrape and sand, heavy1,000SF$ - 0$ - 0
1001AB46Selective Demo Wood Framing, Hardboard, Vinyl or Aluminum Soffit500SF$ - 0$ - 0
1001AB47Sanding, Surface Preparation, placement and removal, basic drop cloths500SF$ - 0$ - 0
1001AB48Asbestos Hazardous Control Activities50SF$ - 0$ - 0
1001AB49Asbestos Testing80EA$ - 0$ - 0
1001AB50Roofing Panels (metal or copper)10,000SF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 1001AB (CLINS 1001AB01 THRU 1001AB50)$ - 0
SUB CLIN 1001AC - METALS for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Square Feet (SF), Each (EA), Pound (LB), Linear Feet (LF), One-vertical step up on stair (RISER), or Vertical Linear Feet (VLF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTION 05500, Metals, Miscellaneous or Fabrications for all previously roofed buildings including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

1001ACMETALS
1001AC01Roof decking, open type B wide rib, galv. 3" deep, 22 gauge under 50 squares100SF$ - 0$ - 0
1001AC02Roof decking, open type B wide rib, galv. 3" deep, 18 gauge under 50 squares100SF$ - 0$ - 0
1001AC03Roof decking, end closures50LF$ - 0$ - 0
1001AC047/8" corrigated roof decking, flexible closurestrip100LF$ - 0$ - 0
1001AC05Lintels, plain steel angles, shop fabricated, under 500 lb50LB$ - 0$ - 0
1001AC06Lintels, plain steel angles, shop fabricated, under 500 to 1000 lb50LB$ - 0$ - 0
1001AC07Steel plates (for antennas and microwave dishes), shop fabricated, 1" thick (40.8 lb/sf)50SF$ - 0$ - 0
1001AC08Lightweight Framing, angle framing, field fabricated, 4" and larger40LB$ - 0$ - 0
1001AC09Lightweight Framing, angle framing, field fabricated, 1" x 1" x 1/8"75LF$ - 0$ - 0
1001AC10Lightweight Framing, angle framing, field fabricated, 2" x 2" x 1/4"75LF$ - 0$ - 0
1001AC11Lightweight Framing, structural zee framing, field fabricated, 3-1/4" x 5" x 3-1/4"50LF$ - 0$ - 0
1001AC12Lightweight Framing, channel framing, field fabricated, C2 x 1.7850LF$ - 0$ - 0
1001AC13Vertical Metal Ladder, shop fabricated steel, 20" wide, bolted to concrete, without cage. (Extend ladder 3'-6" above roof/parapet wall.)10VLF$ - 0$ - 0
1001AC14Vertical Metal Ladder, shop fabricated aluminum, bolted to concrete, without cage.
(Extend ladder 3'-6" above roof/parapet wall.)10VLF$ - 0$ - 0
1001AC15Railings, Industrial, welded, shop fabricated, 2 rail, posts 5' o.c., 3'-6" high, 1-1/2" pipe28LF$ - 0$ - 0
1001AC16Railings, Industrial, welded, shop fabricated, 2 rail, on stairs, primed, 1-1/2" diameter28LF$ - 0$ - 0
1001AC17Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 3'-6" wide20RISER$ - 0$ - 0
1001AC18Metal Grating Stairs, shop fabricated, steel stringers, safety nosing on tread, made from recycled materials, grating tread and pipe railing, 4'-0" wide20RISER$ - 0$ - 0
1001AC19Permanent U-Bolt roof anchor25EA$ - 0$ - 0
1001AC20Temporary (one use) U-Bolt roof anchor12EA$ - 0$ - 0
1001AC21Coping, stock units, aluminum, for 12" wall250LF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 1001AC (CLINS 1001AC01 THRU 1001AC21)$ - 0
SUB CLIN 1001AD - WOOD AND PLASTIC for buildings, warehouses, structures and miscellaneous facilities shall be measured by units of Linear Feet (LF), Thousand Board Feet (MBF), Square Feet of Floor (SF FL), or Square Feet (SF), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 06100A, Rough Carpentry and Section 06200A, Finish Carpentry, for all existing and previously roofed buildings or buildings with expired roof warranties, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

1001ADWOOD AND PLASTIC
1001AD01Misc. Framing, nailers, treated, wood construction, 2" x 4", pneumatic nailed1MBF$ - 0$ - 0
1001AD02Misc. Framing, nailers, treated, steel constr, 2" x 4", pneumatic nailed1MBF$ - 0$ - 0
1001AD03Roof Framing, ridge board, #2 or better, 1" x 6"10MBF$ - 0$ - 0
1001AD04Roof Framing, ridge board, #2 or better, 2" x 8"10MBF$ - 0$ - 0
1001AD05Wood framing, Sleepers, on concrete, treated, 2" x 4"1MBF$ - 0$ - 0
1001AD06Wood Framing, soffits & canopies, canopies or soffit framing, 2" x 4"1MBF$ - 0$ - 0
1001AD07Sheathing, Plywood on roof, CDX, 3/4" thick, pneumatic nailed2,000SF$ - 0$ - 0
1001AD08Sheathing, gypsum, weatherproof, 1/2" thick1,000SF$ - 0$ - 0
1001AD09Sheathing, wood fiber, regular, no vapor barrier, 5/8" thick1,000SF$ - 0$ - 0
1001AD10Roof Framing, fascia boards, 2" x 8"1MBF$ - 0$ - 0
1001AD11Soffits, exterior AC plywood, 1/2" thick200SF$ - 0$ - 0
1001AD12Rafter extension (tails), 2" x 6" ordinary200LF$ - 0$ - 0
1001AD13Rafter extension (tails), 2" x 8" ordinary200LF$ - 0$ - 0
1001AD14Laminated Roof Deck, cedar, 3" thick200SF$ - 0$ - 0
1001AD15Laminated Roof Deck, cedar, 4" thick200SF$ - 0$ - 0
1001AD16Blocking, miscellaneous, to wood construction 2" x 4", Pneumatic Nailed1MBF$ - 0$ - 0
1001AD17Blocking, miscellaneous, to wood construction 2" x 8", Pneumatic Nailed1MBF$ - 0$ - 0
1001AD18Blocking, miscellaneous, to steel construction 2" x 4"1MBF$ - 0$ - 0
1001AD19Blocking, miscellaneous, to steel construction 2" x 8"1MBF$ - 0$ - 0
1001AD20Plywood, underlayment grade, 1/2" thick, pneumatic nailed100SF FLR$ - 0$ - 0
1001AD21Plywood, underlayment grade, 3/4" thick, pneumatic nailed100SF SFR$ - 0$ - 0
1001AD22Oriented Strand Board, underlayment grade, 0.225 inch thick10MBF$ - 0$ - 0
TOTAL AMOUNT FOR SUB CLIN 1001AD (CLINS 1001AD01 THRU 1001AD22)$ - 0
SUB CLIN 1001AE - THERMAL & MOISTURE PROTECTION of buildings, warehouses, structures, & miscellaneous facilities shall be measured by units of Square or 100 square feet (SQ), Linear Feet (LF), Board Foot (BF), Square Feet, an area 12"x12" (SF), or Each (EA), excluding elevated water storage tanks, antennas, fuel storage tanks and other facilities requiring specialized roof systems or materials not specified in the specifications.

NOTE: Unit prices shall include all costs to provide roofing as specified in the specifications, SECTIONS 07214, Board & Block Insulation, thru Section 07920, Joint Sealants, for all previously roofed buildings, or new buildings out of warranty, including all work incidental thereto as set forth in the specifications. The buildings or structures may be of any size, shape, or type of construction.

1001AETHERMAL & MOISTURE PROTECTION
1001AE01Roof Curb, untreated, 2" x 6"1MBF$ - 0$ - 0
1001AE02Roof Cant, split 4" x 4"2MBF$ - 0$ - 0
1001AE03Roof Curb, untreated, 2" x 12"1MBF$ - 0$ - 0
1001AE04Roof Cant, split 6" x 6"1MBF$ - 0$ - 0
1001AE05BUR, asph. Flood coat, smooth surface, 4 plies #15 asphalt felt, mopped, on nailable decks200SQ$ - 0$ - 0
1001AE06BUR, asph. Flood coat, smooth surface, 4 plies #15 organic felt, mopped200SQ$ - 0$ - 0
1001AE07APP modified bituminous membrane, Granule surface cap sheet, poly. Reinf., torched 180 mils1,000SF$ - 0$ - 0
1001AE08APP modified bituminous membrane, Granule surface flashing, torched, 180 mils10,000SF$ - 0$ - 0
1001AE09Asphalt Shingles, premium, laminated multi-layered shingles, Class A, 260-300 lb, 4 bundles/sq, pneumatic nailed100SQ$ - 0$ - 0
1001AE10Self adhering polyethylene and rubberized asphalt underlayment100SQ$ - 0$ - 0
1001AE11Asphalt ridge shingles, pneumatic nailed1,000LF$ - 0$ - 0
1001AE12Clay Tile, access included, ASTM C1167, Spanish tile, red (Clay tile, remove same, salvage, reinstall same tile)4,000SF$ - 0$ - 0
1001AE13Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., fully adhered with adhesive (single ply membrane)100SQ$ - 0$ - 0
1001AE14Polyvinyl-Chloride Roofing (PVC), heat welded seams, reinforced 60 mils, 0.40 P.S.F., loose-laid & ballasted with stone/gravel (12 PSF) single ply membrane100SQ$ - 0$ - 0
1001AE15Cant, 4" x 4" foamglass5,000LF$ - 0$ - 0
1001AE16Asphalt felt, #30, 2 sq per roll100SQ$ - 0$ - 0
1001AE17Ridge Vent, Alum., strips, Painted finish500LF$ - 0$ - 0
1001AE18Ridge Vent, Alum., end caps20EA$ - 0$ - 0

This is the start of the file's text. The full file is on GovTribe.

Other files for this federal contract opportunity

Other files attached to Roofing Indefinite Delivery Indefinite Quantity (IDIQ), newest first.
File Type Posted
FA3047-10-R-0012-0004 Amendment to RFP —
FA3047-10-R-0012-0003 Amendment to RFP Roofing IDIQ.pdf PDF
FA3047-10-R-0012-0002 Amendment to RFP Roofing IDIQ —
FA3047-10-R-0012 Attendance Record —
FA3047-10-R-0012 Atch 1 —
FA3047-10-R-0012 Atch 2N-Division 2 —
FA3047-10-R-0012 Atch 2AA-Division 7 —
FA3047-10-R-0012 Atch 2P-Division 2 —
FA3047-10-R-0012 Atch 2R-Division 2 —
FA3047-10-R-0012 Atch 2AD-Division 7 —
FA3047-10-R-0012 Atch 3 —
FA3047-10-R-0012 Atch 2Y-Division 7 —
FA3047-10-R-0012 RFP for Roofing IDIQ —
FA3047-10-R-0012 Atch 2AK —
FA3047-10-R-0012 Atch 2K-Division 1 —
FA3047-10-R-0012 Atch 2M-Division 2 —
FA3047-10-R-0012 Atch 2L-Division 1 —
FA3047-10-R-0012 Atch 2D-Division 1 —
FA3047-10-R-0012 Atch 2AJ-Division 26 —
FA3047-10-R-0012 Atch 2B-Division 0 —
FA3047-10-R-0012 Atch 2AC-Division 7 —
FA3047-10-R-0012 Atch 2I-Division 1 —
FA3047-10-R-0012 Atch 2G-Division 1 —
FA3047-10-R-0012 Atch 2W-Division 6 —
FA3047-10-R-0012 Atch 2E-Division 1 —
FA3047-10-R-0012 Atch 2S-Division 5 —
FA3047-10-R-0012 Atch 4 —
FA3047-10-R-0012_SBDC_Informational_Map.pdf PDF
FA3047-10-R-0012 Atch 2AF-Division 7 —
FA3047-10-R-0012 Atch 2H-Division 1 —
FA3047-10-R-0012 Atch 2J-Division 1 —
FA3047-10-R-0012 Atch 2A - 8 Feb 10 Table of Contents.pdf PDF
FA3047-10-R-0012 Atch 2Q-Division 2 —
FA3047-10-R-0012 Atch 2AH-Division 8 —
FA3047-10-R-0012 Atch 2X-Division 7 —
FA3047-10-R-0012 Atch 2F-Division 1 —
FA3047-10-R-0012 Atch 2O-Division 2 —
FA3047-10-R-0012 Atch 2V-Division 5 —
FA3047-10-R-0012 Atch 2Z-Division 7 —
FA3047-10-R-0012 Atch 2AB-Division 7 —
FA3047-10-R-0012 Atch 2AG-Division 7 —
FA3047-10-R-0012 Atch 2AI-Division 9 —
FA3047-10-R-0012 Atch 2U-Division 5 —
FA3047-10-R-0012 Atch 2AE-Division 7 —
FA3047-10-R-0012 Atch 2T-Division 5 —
FA3047-10-R-0012 Atch 2C-Division 1 —
Show all 46