Addendum 003 - Valves - Safety Relief Valves R0.pdf

PDF 615 KB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015444 Rev: 00

Description of Item: Safety Relief Valves

Specification Section: 43 11 24

Deviations: See document NYCS000015385

Cover Page Information Revision History and Approvals

Tab 01 - NYCS000015443,CSS,Safety Relief Valves,01.287

INDEX:

Page 1:

Page 2:

Page 3:

Pages 4-5: Tab 02 - NYCS000010287,SRV,Control Devices,SF50,WH013765,WH171713

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

41c Number: NYCS000015443R00 Doc Title: NYCS000015443,CSS,Safety Relief Valves,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015444, Safety Relief Valves,01.287:

L‐897, Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 43 11 24, Compressed Air System.

Any exceptions and clarifications to the specification section above can be found in submittal NYCS000015385,L‐897,Section 43 11 24,Es and Cs,01.287.

Pall has not taken any exceptions or clarifications relevant to the safety relief valve proposed.

ASME Safety Valves

Model "SA" ASME safety valves are designed for high temperature applications such as intercoolers and after-coolers where a compact size is required. All brass construction with stainless steel spring and stainless steel ball seating on brass seat.

Three inlet sizes available: 1/8" NPT, 1/4" NPT, 3/8" NPT.

Stamped with "UV" and "NB" symbols. Available set pressure range 50-350 PSI (345-2410 kPa). Set pressure tolerance +

The data provided above is for information purposes only and no warranty of accuracy or reliability is given. Ross Brown Sales Pty Limited reserves the right to change or modify this data without prior notice

3% of set pressure. 175°C max. temperature.

SCFM

0 50 100 150 200 250 300 PSI

Model Connection Set Pressure Dimensions (mm) Height x Hex

Weight (gms) Part Number

SA12 1/8” NPT 50-350 PSI 54 17.5 70 On Request SA25 1/4” NPT 50-350 PSI 54 17.5 70 On Request SA38 3/8” NPT 50-350 PSI 54 17.5 70 On Request

Model "SH" safety valve is our "hard seated" ASME safety valve. An efficient seal is maintained by virtue of a precision stainless steel ball and matching brass seat. These valves find wide use in intercoolers and other applications where high temperatures are encountered. Three inlet sizes available: 1/8" NPT, 1/4" NPT, 3/8" NPT.

All brass construction with stainless steel spring and stainless steel ball. Stamped with "UV" and "NB" symbols. Available set pressure range 50-250 PSI (345-1725 kPa). Set pressure tolerance +3% of set pressure. 175°C max. temperature.

Weight (gms) Part Number

SH25 1/4” NPT 50-250 PSI 70 17.5 85 On Request SH38 3/8” NPT 50-250 PSI 70 17.5 85 On Request

Model "SF" ASME safety valves are designed for systems where large flow capacities are needed. Resilient pad insures valve is bubble-tight to within 10% of set pressure. Inlet size: 1/2" NPT.

All brass construction with zinc-plated piano wire spring and a rubber seal, offered in silicone or fluorocarbon. Stamped with "UV" and "NB" symbols. Available set pressure range 50-250 PSI (345- 1725 kPa). Set pressure tolerance +3% of set pressure. 120°C max. temperature.

Weight (gms) Part Number

SF50 1/2” BSPT 965 kPa 86 22.2 170 4012900 SF50 1/2” BSPT 1035 kPa 86 22.2 170 4013000 SF50 1/2” BSPT 1135 kPa 86 22.2 170 4013200 SF50 1/2” BSPT 1200 kPa 86 22.2 170 4013500 SF50 1/2” BSPT 1380 kPa 86 22.2 170 4014000 SF50 1/2” BSPT 1600 kPa 86 22.2 170 4014500

0 50 100 150 200 PSI

0 50 100 150 200 PSI

larkind Rectangle larkind Rectangle larkind Text Box 150 psig larkind Text Box 200 psig larkind Line larkind Line larkind Text Box Document: NYCS000010287R01 larkind Text Box Example part numbers:

WH171713 Part# 4013000, 150 psig WH013765 Part# 4014000, 200 psig

THIS DOCUMENT CONTAINS PROPRIETARY AND CONFIDENTIAL INFORMATION DATE SYM REVISION RECORD ECN NO. CK.

OF CONTROL DEVICES INC. AND MUST BE USED STRICTLY IN ACCORDANCE

WITH THE UNITED PURPOSE FOR WHICH IT WAS SUBMITTED. ANY REPRO-

DUCTION, DISCLOSURE OR USE OF THIS DOCUMENT IS EXPRESSLY PRO- 3/94 A REDRAWN ON AUTOCAD

HIBITED, EXCEPT AS OTHERWISE AGREED IN WRITING.

PULL RING

SET PRESSURE, RELIEF CAPACITY, "UV" SYMBOL, AND "NB" STAMPED ON CAP

7/8 WRENCHING FLATS

NOTES 1. SET PRESSURE RANGE IS 50 PSI 1/2 NPT TO 250 PSI 2. RELIEF CAPACITY IS GIVEN BY THE EQUATION Q = 1.526(1.1P + 14.7), WHERE Q = RELIEF CAPACITY IN SCFM, AND P = SET PRESSURE IN PSIG 3. MATERIALS OF CONSTRUCTION: BODY, NUT, CAP, ADJ. SCREW, ROD, DISC -- BRASS SPRING -- ZINC PLATED MUSIC WIRE PULL RING -- STAINLESS STEEL PAD -- SILICONE OR FLUOROCARBON RUBBER SEAL -- LEAD 4. MAX TEMPERATURE 250° F

TOLERANCES

(EXCEPT AS NOTED)

DECIMAL ± .005 _

kRAcTioNAL ± .015

XE) 711 HANLEY INDUSTRIAL COURT ST. LOUIS, MISSOURI 63144

control devices inc.

MATERIAL SCALE

FULL

SIZE

A DRAWN BY km ..1

APPROVED BY

ANGULAR + 2*

DATE 2/12/93

TITLE

VALVE, ASME SAFETY, 1 /2 NPT

CAD ALE DRAWING NUMBER

ALL DIMENSIONS ARE IN INCHES. C:\ACADWIN\PARTDWGS\SF50.DWG SF50 REV A 5

Cover Page Information
Revision Page and Approvals
Tab 01 - NYCS000015443,CSS,Safety Relief Valves,01.287
Tab 02 - NYCS000010287,SRV,Control Devices,SF50,WH013765,WH171713
Title: Safety Relief Valves, 01.287
Document: NYCS000015444
Revision: 00
RevRow1: 0
NameCreated By: DMLarkin
DateCreated By: 16-DEC-2019
NameApproved By: JHoskins
DateApproved By: 16-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .