Addendum 003 - Valves - Other Solenoid Valves R0.pdf

PDF 731 KB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015392 Rev: 00

Description of Item: Other Solenoid Valves

Specification Section: 40 05 52

Deviations: See document NYCS000015373

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3: Tab 1 - NYCS000015418,CSS,Other Solenoid Valves,01.287

Pages 4-5: Tab 2 - NYCS000015425,Solenoid,NC,120VAC,0.375inch,NSF-61,WH172210

Pages 6-7: Tab 3 - NYCS000015246,Solenoid,NC,120VAC,NSF-61,WH171949

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Doc Number: NYCS000015418R00 Doc Title: NYCS000015418,CSS,Other Solenoid Valves,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015392, Other

Solenoid Valves,01.287:

L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 40 05 52, Miscellaneous Valves.

Any exceptions and clarifications to the specification section above can be found in submittal:

NYCS000015373, Es and Cs, Section 40 05 52,01.287.

Pall has taken any exceptions and clarifications relevant to the other solenoid valves proposed.

Per RCI‐022, the GC solenoid valves were preliminarily approved.

NS201 Series

- 3/8" NPT

- Noryl Body

- 2-Way Zero Differential Piloted Diaphragm

- Normally Closed

Materials Seals: Santoprene/NSF Approved EPDM

Orifice: Pilot Stainless Steel

Main Noryl

Electrical Housing: NEMA 4/4X Encapsulated - 1/2" Conduit

Optional Housings: Contact GC Valves Customer Svc. for available options.

Voltage: 24,120,240, VAC, 60 and/or 50 Hz. Available.

6, 12, 24 VDC

Contact GC Valves Customer Svc. for available optionsoptions.

Voltage Tolerance: + 10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inches

Operating Temperature Ambient (Nominal): 32o F to 125o F

Mounting Position: Any

Approvals* Agency: NSF/ANSI - 61-G / NSF-372 / UR Recognized

* Not available for all variations

Weight (lbs.)

Dimensions / Weight

GC Valves Customer Service: 800-828-0484 (7:30 AM to 5:00 PM ET) larkind Text Box Document: NYCS000015425, R00

LarkinD Text Box

WH172210

Part #: NS201GF02FPCG4

GC Valves Customer Service: 800-828-0484 (7:30 AM to 5:00 PM ET)

LarkinD Text Box

LarkinD Text Box

LarkinD Text Box

LarkinD Rectangle

LarkinD Rectangle

LarkinD Rectangle

LarkinD Rectangle

LarkinD

GC Valves Customer Service: 800-828-0484 (7:30am to 4pm ET) or 800-582-4232 (7:30am to 4pm PT) 3/4-P-202-1

S20 Series

- 3/4" NPT

- Noryl Body

- 2-Way Zero Differential

Piloted Diaphragm

- Normally Open

Materials Seals: Nitrile, Viton®, Ethylene Propylene

Orifice:PilotStainlessSteel
MainNorylØ3/4”

Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)

OptionalHousings:MetallicConduit,Explosion-proof(NEMA7),Grommet,
OpenFrame,JunctionBox(singleordualknockouts),
DIN;ContactGCValvesCustomerServiceforothers.
StandardVoltages:24,120,240AC60Hz;50Hzavailable
6,12,24DC;
ContactGCValvesCustomerServiceforAdditional
Voltages.

Voltage Tolerance: ±10% of applicable voltage

Coil Classes: F, H, N

Standard Lead Length: 24 inch

Operating Temperature Ambient (Nominal): 32°F to 125°F

Mounting Position: Any

Approvals* Agency: UL Recognized, CSA Approved, CE Certified

® Registered Trademark of DuPont Co.

Dimensions/Weight

Weight (oz.)

* Not available for all variations larkind Text Box Document: NYCS000011246R02

LarkinD Text Box

WH171949

Part #: NS201GF02FPEG5

LarkinD

Closed

GC Valves Customer Service: 800-828-0484 (7:30am to 4pm ET) or 800-582-4232 (7:30am to 4pm PT) 3/4-P-202-2

S202 – 3/4" NPT, Noryl Body, Normally Open

Part Numbering

S 2 0 2 G F 0 2 C P E G 5 Series Operating

Mode Housing* Coil Class* Voltage* Seal

Material Body

Material Pipe

Connection Orifice Size

S20 G: Conduit F: Class F 02: 120/60 110/50

C:EPR
N:Nitrile
V:Viton

P: Noryl E: 3/4” NPT G5: 3/4”

* See the “Engineering Guide” for additional voltages, variations and options.

1 2 3 4 5 6 7 8 9 10 11 12 13

2: Normally Open

Coil Data

Frequency (Hz) 60 50

Nominal Power (VA) Inrush 46 46

Holding 22 25

Coil Family

Type Size

All S4

Normally Open

Valve Selection List

P P

Energized

P

De-Energized

IN °F

O rif ic e

S iz e

P ip e S iz e

M in im um

AC DC AC DC AC DC

S ea l M at er ia l

M ax

F lu id

T em p.

CvNPT

Air/Gas Water

Operating Pressure Differential (psi) Maximum

Power Consumption

(Watts)

Model Code

120V/60HZ — 110V/50HZ

Shown

Noryl Body

3/4 6.7 0 200 125 200 125 295 EPR 11 10 S202GF02CPEG5

3/4

3/4 6.7 0 200 125 200 125 180 Nitrile 11 10 S202GF02NPEG5

3/4 6.7 0 200 125 200 125 230 Viton 11 10 S202GF02VPEG5 larkind Text Box larkind Text Box

N = NSF-61

complaint larkind Text Box N larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Highlight larkind Text Box larkind Text Box F: Santoprene diaphragm EPDM o-ring larkind Text Box F

LarkinD Text Box

WH171949

Part #: NS201GF02FPEG5 larkind Text Box 1 = Normally Closed larkind Text Box

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Stamp

LarkinD

Closed

Cover Page Information
Revision History and Approvals
Tab 1 - NYCS000015418,CSS,Other Solenoid Valves
Tab 2 - NYCS000015425,Solenoid,NC,120VAC,0.375inch,NSF-61
Tab 3 - NYCS000011246,Solenoid,NC,120VAC,NSF-61
Title: Other Solenoid Valves, 01.287
Document: NYCS000015392
Revision: 00
RevRow1: 0
NameCreated By: DMLarkin
DateCreated By: 12-DEC-2019
NameApproved By: JHoskins
DateApproved By: 12-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .