Addendum 003 - Equipment - Water Softener R0.pdf

PDF 2 MB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015356 Rev: 00

Description of Item: Water Softener

Specification Section: 43 53 52

Deviations: See document NYCS000015390

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3: Tab 1 - NYCS000015413,CSS,Water Softeners,01.287

Pages 4: Tab 2 – Culligen, Scope of Supply

Pages 5-6: Tab 3 – Culligen Water Softener Overview

Pages 7: Tab 4 – CAD,CSMSoftenerDuplex_04-26-05

Pages 8: Tab 5 – Culligen Link to Drawings

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Doc Number: NYCS000015413R00 Doc Title: NYCS000015413,CSS,Water Softeners,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015356, Water

Softeners,01.287:

L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 43 53 52, Water Softeners.

Any exceptions and clarifications to the specification section above can be found in submittal:

NYCS000015390, Es and Cs, Section 43 53 52,01.287.

Pall has taken exceptions and clarifications relevant to the water softeners proposed.

Use Culligan® equipment to help meet the highest standard of water quality at your facility. The Culligan® Side Mount heavy-duty softener reduces hard water contaminants*, even for large flow volume applications, reducing scale buildup that can affect equipment performance. The Culligan®-exclusive Smart

Controller allows you to efficiently set up and manage your water treatment.

Using optional accessories, monitor water usage data, such as the flow rate and volume, and regenerate the system as needed, saving resources and money.

The CSM softener is part of the Culligan® Commercial and Industrial

Solutions that combine durable and efficient equipment, systems experience, and technical experts who understand your unique requirements. From planning your system to installing your water treatment equipment, Culligan®

Commercial and Industrial Solutions offer options that help deliver the quality of water to meet your needs. Contact Culligan® today to learn more about the

CSM softener system.

CULLIGAN® COMMERCIAL & INDUSTRIAL ADVANTAGES:

• Simple System Integration

• Global Product Platform

• Flexible Configurations

• Quick Delivery / Easy Installation

• Exclusive Culligan Advanced Electronics

- Historical Operating Data

- Alarm Recognitions

- US Standard and Metric Readings

- Remote Monitoring Options

- Telemetry Options

WATER SOFTENER SYSTEM

The Culligan Side Mount (CSM™) Series

Efficient and Scalable Heavy-Duty Water Treatment System

PRE-TREATMENT SOLUTIONS.

*Contaminants may not necessarily be in your water.

Clinics Educational Facilities Energy / Power Food / Beverage Production Food Service / Restaurants Grocery Healthcare / Hospitals / Bio-Pharmaceutical Hospitality / Lodging Manufacturing Municipal Drinking Water Oil / Gas

Markets Served:

www.culligan.com • 866-787-4293

Model Resin Qty. (ft3/L) Pipe Size (in/mm) Flow Rates (gpm/lpm) Tank Size*** (in/mm)

Continuous* Peak** Softener Brine****

150-2 5 2 67 94 20 x 54 24 x 50

142 50.8 253.6 355.8 508 x 1,372 610 x 1,270

210-2 7 2 76 102 24 x 54 24 x 50

198 50.8 287.7 386.1 610 x 1,372 610 x 1,270

300-2 10 2 84 112 30 x 60 30 x 50

283 50.8 317.9 423.9 762 x 1,524 762 x 1,270

300-3 10 3 152 210 30 x 60 30 x 50

283 76.2 575.3 794.9 762 x 1,524 762 x 1,270

450-2 15 2 79 106 30 x 60 30 x 50

425 50.8 299 401.2 762 x 1,524 762 x 1,270

450-3 15 3 135 192 30 x 60 30 x 50

425 76.2 511 726.7 762 x 1,524 762 x 1,270

600-2 20 2 94 125 36 x 60 39 x 48

566 50.8 355.8 473.1 914 x 1,524 991 x 1,219

600-3 20 3 183 252 36 x 60 39 x 48

566 76.2 692.7 953.8 914 x 1,524 991 x 1,219

750-2 25 2 97 129 42 x 60 42 x 48

708 50.8 367.1 488.3 1,067 x 1,524 1,067 x 1,219

750-3 25 3 201 267 42 x 60 42 x 48

708 76.2 760.8 1010.6 1,067 x 1,524 1,067 x 1,219

900-2 30 2 96 127 42 x 60 42 x 48

850 50.8 363.4 480.7 1,067 x 1,524 1,067 x 1,219

900-3 30 3 193 259 42 x 60 42 x 48

850 76.2 730.5 980.3 1,067 x 1,524 1,067 x 1,219

*Flow rate at a 15 psi pressure loss.

**Flow rate at a 25 psi pressure loss.

***Dimensions are diameter by tank height.

****Brine systems are optional.

Flow rates shown are per tank.

Low flow channeling (flow rates less than

0.5 gallons per minute per cubic foot of resin) may cause hardness leakage into effluent.

CSM product formerly sold under the Bruner label.

1 120 Volt/24 Volt CUL/UL listed Transformer Included.

2 See media specification for details.

System Specifications Specification US Metric

Inlet Pressure (dynamic)

30–100 psig 210–690 kPa

Power Voltage Frequency Phase

120 Volts 50/60Hz

Feed Water Temperature

40–120° F 4-49° C

Turbidity Chlorine Iron

5 NTU, max.2

1 mg/L, max.2

5 mg/L, max.2

Standard Features

• Single, Multiple Tank Configurations –

Hardness removal capacities up to 900,000 grains per tank Continuous flow rates up to 201 gpm per tank

• Culligan’s Smart Controller – More control over your equipment with programming and monitoring capabilities typically found in more expensive PLC controls A variety of add-on options for advanced instrumentation and communication let you easily customize the system to help meet your needs

• Telemetric Capability

• Regeneration initiation by choice or combination of time clock, meter or Aqua-Sensor® inputs

• Culligan’s Multiport Valve – Our guided perimeter-designed diaphragm valves are built with reinforced rubber components to resist damage from particulates in the water and ensure smooth operation free of water hammer. The inside and outside surfaces of the valve are electro-coated to deter corrosion. The valve was designed with serviceability in mind; accessibility for installation and maintenance won’t be an issue.

• Corrosion resistant tanks – Made of low carbon steel with epoxy interior lining and finish coat painted exterior

Examples of Softener Applications

• Food and Beverage–Improved taste

Educational Facilities—Boiler and cooling tower make-up water for scale reduction and improved energy costs

• Restaurants—For dishwashing, cleaning material savings, scale reduction

• RO Softener / DI Pretreatment

• Car washes—Quality results, detergent and water heating savings, scale reduction

• Apartment buildings, assisted living facilities and hotels—Quality water for laundry, dishwashers, boilers

• Grocery / Retail—Quality water for aesthetics and help extend equipment life

• Light industry—For process and make-up water, boiler and cooling system pretreatment, general housekeeping

• Office buildings—For heating plant pretreatment, tenant convenience, general housekeeping

Optional Features & Accessories

• Corrosion resistant brine system construction for long life

• Skid Mounted – fully pre-piped and wired systems for single point field utility connection of inlet, outlet, drain and power supply

• Patented Progressive Flow – Culligan’s Smart Controller can monitor flow demands bringing additional softening tanks on-line or offline as flows increase or decrease

• ASME Code Tanks

• Brine Reclaim – reduces operating costs

• Patented Aqua-Sensor® Control – initiates regeneration only when needed based upon water hardness, automatically adjusts to changes in raw water hardness and water consumption

• Flow Measuring Devices – are available for direct connection to the Culligan®

Smart Controller for volume based regeneration initiation

• Remote Display

• RS232, RS485, Modbus PLC Output

Warranty Culligan’s CSM water softeners are backed by a limited 1-year warranty against defects in material, workmanship and corrosion. In addition, softener tanks are warranted for a period of 5 years.†

† See printed warranty for details. Culligan® will provide a copy of the warranty upon request.

Some localities have corrosive water. A softener cannot correct this condition, so its printed warranty disclaims liability for corrosion of plumbing lines, fixtures, or water-using equipment. If you suspect corrosion, your independently operated Culligan® dealer has equipment to help control the problem.

CSM Water Softener System

S Y S T E M S P E C I F I C AT I O N S

©2016 Culligan International Company Part No. 46964

For over 80 years, Culligan® has made better water. Our global network, comprised of 800+ dealers and international licensees in over 90 countries, is dedicated to addressing your water-related problems. As a worldwide leader in water treatment, our sales representatives and service technicians are familiar with the local water conditions in your area. Being global and local position us to deliver customized solutions to commercial and industrial water issues that affect your business and your bottom line.

All trademarks used herein are registered trademarks of Culligan International Company.

Products manufactured or marketed by Culligan and its affiliates are protected by patents issued or pending in the United States and other countries.

Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice.

Tested and Certified by WQA to NSF/ANSI 372

LarkinD Rectangle

CempaG Rectangle

CempaG Rectangle

LarkinD Text Box

(3) 3/4" holes in 1/2" thick carbon steel (A36) 4 inches wide. See photos.

Link to Water Softener drawings per Culligen.

This may be helpful.

You can use eDrawings to view it, it is a free software, below is the link.

https://www.solidworks.com/sw/support/eDrawings/e2_register.htm?downloadtype=64bit#_ga=2.236

852743.787688965.1572015021-c2712380-f736-11e9-8681-eda2285fa31a

Conver Page Information
Revision History and Approvals
Tab 1 - NYCS000015413,CSS,Water Softeners
Tab 2 - Culligen, Scope of SUpply
Tab 3 - Culligen Water Softener Overview
Tab 4 - CAD_CSMSoftenerDuplex_04-26-05
Tab 5 - Culligen Link to Drawings
Title: Water Softeners, 01.287
Document: NYCS000015356
Revision: 00
RevRow1: 0
NameCreated By: DMLarkin
DateCreated By: 13-DEC-2019
NameApproved By: JHoskins
DateApproved By: 13-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .