Addendum 003 - Valves - Dual Disc Check Valves R0.pdf

PDF 429 KB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015217 Rev: 00

Description of Item: Dual Disc Check Valves, 01.287

Specification Section: 40 05 66

Deviations: See document NYCS000015376

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3: Tab 1 - NYCS000015408,CSS,Dual Disc Check Valves,01.287

Pages 4-5: Tab 2 - NYCS000015283,SureFlow,Dual Disc Check,2in,WH172257

Pages 6-7: Tab 3 - NYCS000015284,SureFlow,Dual Disc Check,6in,WH172258

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Doc Number: NYCS000015408R00 Doc Title: NYCS000015408,CSS,Dual Disc Check Valves,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015217, Dual Disc Check Valves,01.287:

L‐897, Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 40 05 66, Check Valves.

Any exceptions and clarifications to the specification section above can be found in submittal NYCS000015376,L‐897,Section 40 05 66,Es and Cs,01.287.

Pall has taken exceptions and clarifications relevant to the dual disc check valves proposed.

BURLINGTON, ONTARIO, CANADA

LarkinD Text Box

NYCS000015283R00

LarkinD Text Box

WH172257

Part #: 0200FE150SSVIRK

LarkinD Rectangle

June 12, 2007

Installation Manual for Sure Flow Equipment Dual Door Check Valves

The valve is inserted between two companion flanges with gaskets on contact faces. Stud bolts that will span the valve and flanges are installed, and the joint made up in the same manner as any flanged joint. The Sure Flow wafer check valve flange diameter has been sized such that the valve centerline will be in alignment with the center of the companion flanges when it is cradled by the stud bolts. The normal installation of the Sure Flow wafer check valve is for horizontal flow with the pin vertical, which allows the plates to swing correctly. The valve should be installed a minimum of 7 to 10 pipe diameters away from any turbulence. The valve may be installed for vertical flow-up or vertical flow-down. When installed in a vertical pipeline, the valve may require a special torque spring or lightweight plates according to the direction of flow, the line pressure, or the line medium.

When removing the valve from the line, only one half of the stud bolts need to be removed, and the others just loosened.

In order to ensure correct installation, the direction of flow is indicated by arrows cast into the side of the body.

BURLINGTON, ONTARIO, CANADA

LarkinD Text Box

NYCS000015284R00

LarkinD Text Box

WH172258

Part #: 0600FE150SSVIRK

LarkinD Rectangle

June 12, 2007

Installation Manual for Sure Flow Equipment Dual Door Check Valves

The valve is inserted between two companion flanges with gaskets on contact faces. Stud bolts that will span the valve and flanges are installed, and the joint made up in the same manner as any flanged joint. The Sure Flow wafer check valve flange diameter has been sized such that the valve centerline will be in alignment with the center of the companion flanges when it is cradled by the stud bolts. The normal installation of the Sure Flow wafer check valve is for horizontal flow with the pin vertical, which allows the plates to swing correctly. The valve should be installed a minimum of 7 to 10 pipe diameters away from any turbulence. The valve may be installed for vertical flow-up or vertical flow-down. When installed in a vertical pipeline, the valve may require a special torque spring or lightweight plates according to the direction of flow, the line pressure, or the line medium.

When removing the valve from the line, only one half of the stud bolts need to be removed, and the others just loosened.

In order to ensure correct installation, the direction of flow is indicated by arrows cast into the side of the body.

Cover Page Information
Revision History and Approvals
Tab 1 - NYCS000015408,CSS,Dual Disc Check Valves
Tab 2 - NYCS000015283,SureFlow,Dual Disc Check,2in
Tab 3 - NYCS000015284,SureFlow,Dual Disc Check,6in
Title: Dual Disc Check Valves, 01.287
Document: NYCS000015217
Revision: 00
RevRow1: 0
NameCreated By: DMLarkin
DateCreated By: 09-DEC-2019
NameApproved By: JHoskins
DateApproved By: 09-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .