Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf

PDF 2 MB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TOP VIEW

(84 MODULE FILTER RACK ASSEMBLY WITH 72 MODULES INSTALLED)

(5-4-5 MODULE SECTION ASSEMBLY)

FRONT VIEW

LEFT VIEW

REAR VIEW

-VALVE RACK ONLY-

SECTION D-D

-VALVE RACK ONLY, SOME ITEMS REMOVED FOR CLARITY-

(CONN. 'D' FLANGE FACE TO FRAME FACE)

A A

B B

C C

D D

E E

F F

G G

H H

FORMAT VER: R2013.2

DRAWING NAME

REVISIONDRAWING NUMBER

MATERIAL MASTER DWG SIZE

PROJECT ID

DRAWN BY

PROJECT ENGINEER

ENGINEER

CHECKER

ENGINEER

ENGINEER

NAME DATE

THIRD ANGLE

PROJECTION

CODE IDENTIFICATION NO.

TOLERANCE

ANGLE ± DEG

FRACTION ±

.XXX ±

.XX ±

.X ±

X. ±

DIMENSIONS ARE IN:

INCHES

ONLY

MILLIMETERS

ONLY

IN [mm] mm [IN]

IMPORTANT: BEFORE ATTEMPTING TO OPERATE OR INSTALL THIS SYSTEM, IT IS ESSENTIAL TO READ AND UNDERSTAND

THIS PRODUCT'S OPERATION AND MAINTENANCE MANUAL (SHIPPED UNDER SEPARATE COVER). FAILURE TO READ THE

OPERATION AND MAINTENANCE MANUAL BEFORE ATTEMPTING TO OPERATE ANY PALL CORPORATION EQUIPMENT MAY

RESULT IN SERIOUS PERSONAL INJURY AND/OR PRODUCT DAMAGE, AND VOID ANY AND/OR ALL WARRANTIES.

ALL FINISHED SURFACES

SCALE DO NOT SCALE

FROM DRAWING

UNLESS OTHERWISE SPECIFIED, THE FOLLOWING

INFORMATION PERTAINS ONLY TO THIS SHEET

µIN µm

17238

Copyright 2019 PALL CORPORATION This document may contain confidential technical data, including trade secrets proprietary to Pall Corporation. The drawing, design rights and all other disclosures in this document are the property of Pall Corporation. Unauthorized use, copying, distribution to third parties, manufacture, or reproduction in whole or in part is prohibited.

PALL Corporation

SHEET OF

SEE SHEET 1 FOR REVISION

1 2 WH172207

01.000287

09SEP2017

12MAR2018

These commodities, technology or software may only be exported from the United States in accordance with the

Export Administration

Regulations. Diversion contrary to U.S. law is prohibited.

.XXXX ±

Pall Advanced Separation Systems Industrial, Cortland NY

1/20

X

1/2

1/4

CONNECTION DESCRIPTION CONN. SIZE TYPE

A FEED CONNECTION 8in 150# FLANGE

A1 AIR SCRUB SUPPLY 3in 150# FLANGE

A2 INSTRUMENT AIR 1/2in 150# FLANGE

C1 CIP FEED 4in 150# FLANGE

C2 CIP/EFM RETURN 4in 150# FLANGE

C3 CIP RETURN BLEED 2in 150# FLANGE

D1 AS/RF (UPPER) DRAIN 8in 150# FLANGE

D2 FILTRATE VENT 2in 150# FLANGE D3 AS/RF (LOWER) DRAIN 6in 150# FLANGE F1 FILTRATE/RF 8in 150# FLANGE F2 REVERSE FILTRATION SUPPLY 8in 150# FLANGE

16 [249]

0]

[1

3]

[2

4]

8 [295]2X

51 [1295]

8 [842]

16 [323]

2 [216]

16 [141]

48 [1219]

16 [852]

16 [5694] O.A.L.

(7

O

.A .W

GENERAL NOTES (APPLY TO ALL SHEETS)

1. THE VALVE RACK IS FACTORY ASSEMBLED AND TESTED BY PALL. THE VALVE RACK IS

SHIPPED FULLY ASSEMBLED AND WIRED, WITH THE EXCEPTION OF THE PRESSURE

INSTRUMENTS, WHICH ARE SHIPPED LOOSE FOR FIELD ASSEMBLY BY OTHERS.

2. PIPING, CONNECTING TO PALL EQUIPMENT, MUST BE ADEQUATELY SUPPORTED

TO PREVENT ANY NOZZLE LOADS ON THE EQUIPMENT.

DO NOT USE SKID CONNECTIONS TO SUPPORT PIPING.

3. ALL FLANGES ARE BOLT CIRCLE/HOLE SIZE EQUIVALENT TO ANSI 150# RATED

FLANGES.

4. THE DISC ON ELASTOMER-SEATED BUTTERFLY VALVES MUST BE AT LEAST

PARTIALLY OPEN WHEN TIGHTENING FLANGE BOLTS. FAILURE TO DO SO WILL

CAUSE PREMATURE FAILURE, AND WILL VOID ALL WARRANTIES ON THE VALVE.

5. EACH MODULE RACK IS SHIPPED PARTIALLY ASSEMBLED. REFER TO SEPARATE

INSTALLATION INSTRUCTIONS.

6. MODULES ARE SHIPPED SPEARATELY. DO NOT DROP OR EXPOSE THE MODULES

OR THEIR SHIPPING CONTAINERS TO SHOCK OR IMPACT. THERE MAY BE DAMAGE

TO THE MEMBRANE EVEN IF NO VISIBLE DAMAGE TO THE MODULE CASE IS

EVIDENT. DO NOT STORE THE MODULES OR THEIR SHIPPING CONTAINERS

OUTSIDE OR IN AN AREA WHERE THERE WILL BE EXPOSURE TO DIRECT SUNLIGHT,

EXCESSIVE HEAT, OR COLD. PALL CORPORATION REQUIRES MEMBRANES BE

STORED IN A CONTROLLED, SECURE ENVIRONMENT TO GUARANTEE MODULES

ARE NOT DAMAGED DURING STORAGE.

7. SEE ELECTRICAL DRAWINGS FOR FIELD WIRING REQUIREMENTS.

8. INSTRUMENT GRADE AIR AT 90PSIG [620.5 KPA] REQUIRED FOR VALVE ACTUATION.

9. MATERIALS OF CONSTRUCTION:

a) FRAME (STRUCTURAL MEMBERS) : CARBON STEEL - PAINTED

b) BOLTING: STAINLESS STEEL

c) PIPING (WETTED COMPONENTS): PVC, EPDM, STAINLESS STEEL, HDPE, NORYL

OR XYRON

d) MODULES: PVDF, ABS, POLYURETHANE

10. DO NOT DRILL OR OTHERWISE MODIFY PAINTED FRAME MEMBERS.

11. ANCHOR BOLT REQUIREMENTS TO BE PROVIDED IN SEISMIC REPORT.

12. ESTIMATED WEIGHTS: (FULL BUILD OUT OF 84 MODULES INSTALLED)

VALVE RACK DRY - 3,500 LB.

FILTER RACKS DRY-W/MODULES - 13,000 LBS.

VALVE RACK WET - 4,200 LB.

FILTER RACKS WET-W/MODULES - 21,000 LBS.

3 [77]9X

[3

9]

3X

15 [381]2X

GROUND LUG

REVISION CHG BY PROJ ENG ENG/APVD ENG/APVD ENG/APVD CHKD/APVD

UPDATED ALL VALVE RACK AUTOMATED VALVES TO

PROJECT SPECIFIC; MODULE RACK WAS 72 SPACES

W/66 MODULES INSTALLED

DHT

22OCT2019

DML

19NOV2019

SAW

19NOV2019

REVISION DESCRIPTION

] O .A

.H

[3

1]

2X nnnn11 4 [nnnn32]2X EYE

LIFT LUG

8 [651]2X

ELECTRICAL

PANEL

(3

[8

C L

E A

R A

N C

E F

O R

E L

E C

2 [13](115

8 [295])

(1 2 [13])4X (3 4 [19])6X

VALVE RACK ONLY

SCALE: NONE DETAIL C

SCALE 1 / 4

TYP (6) PLACES

SECTION A-A

EQUIPMENT BASE PLATES

SCALE 1/20

DETAIL B

SCALE 1 / 2

TYP (4) PLACES

ASSEMBLY ISOMETRIC VIEW

SCALE: NONE

A A

B B

C C

D D

E E

F F

G G

H H

FORMAT VER: R2013.2

DRAWING NAME

REVISIONDRAWING NUMBER

MATERIAL MASTER DWG SIZE

PROJECT ID

DRAWN BY

PROJECT ENGINEER

ENGINEER

CHECKER

ENGINEER

ENGINEER

NAME DATE

THIRD ANGLE

PROJECTION

CODE IDENTIFICATION NO.

TOLERANCE

ANGLE ± DEG

FRACTION ±

.XXX ±

.XX ±

.X ±

X. ±

DIMENSIONS ARE IN:

INCHES

ONLY

MILLIMETERS

ONLY

IN [mm] mm [IN]

IMPORTANT: BEFORE ATTEMPTING TO OPERATE OR INSTALL THIS SYSTEM, IT IS ESSENTIAL TO READ AND UNDERSTAND

THIS PRODUCT'S OPERATION AND MAINTENANCE MANUAL (SHIPPED UNDER SEPARATE COVER). FAILURE TO READ THE

OPERATION AND MAINTENANCE MANUAL BEFORE ATTEMPTING TO OPERATE ANY PALL CORPORATION EQUIPMENT MAY

RESULT IN SERIOUS PERSONAL INJURY AND/OR PRODUCT DAMAGE, AND VOID ANY AND/OR ALL WARRANTIES.

ALL FINISHED SURFACES

SCALE DO NOT SCALE

FROM DRAWING

UNLESS OTHERWISE SPECIFIED, THE FOLLOWING

INFORMATION PERTAINS ONLY TO THIS SHEET

µIN µm

17238

Copyright 2019 PALL CORPORATION This document may contain confidential technical data, including trade secrets proprietary to Pall Corporation. The drawing, design rights and all other disclosures in this document are the property of Pall Corporation. Unauthorized use, copying, distribution to third parties, manufacture, or reproduction in whole or in part is prohibited.

PALL Corporation

SHEET OF

SEE SHEET 1 FOR REVISION

2 2 WH172207

01.000287

09SEP2017

12MAR2018

These commodities, technology or software may only be exported from the United States in accordance with the

Export Administration

Regulations. Diversion contrary to U.S. law is prohibited.

.XXXX ±

Pall Advanced Separation Systems Industrial, Cortland NY

AS SHOWN

X

1/2

1/4

CL

8 [16]4X

8 [219]

4 [298]

16 [40]

[2

8 [48]

[2

R5

16 [8] TYP

8 [149]

[1

7]

45 [1143] nnnn1 [nnnn25]

1/2-20 UNF - 2B THRU

[7

6]43

[1

[1

1 [25]

2 [165]

16 [2469] 48 [1219] 60 [1524]

[1

9]

[1

4]

[8