Addendum 003 - Equipment - Centrifugal Pumps R0.pdf

PDF 5 MB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015143 Rev: 00

Description of Item: Centrifugal Pumps

Specification Section: 01 61 03 and 43 21 00

Deviations: See document NYCS000015364 and NYCS000015386

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3: Tab 1 - NYCS000015402,CSS,Centrifugal Pumps,01.287

Pages 4-20 Tab 2 - NYCS000015287,Goulds,6SH,20HP,3500,460V,PE,256JM,CH,GR, WH172297

Pages 21-40 Tab 3 - NYCS000015286,Grundfos,CRN64-1-1,10HP,3500,460V,PE,213TC,GH, WH172296

Pages 41-45: Tab 4 - NYCS000015351,Grundfos,CRN10-1,0.75HP,3500rpm,120V,SDM, WH1722339

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Doc Number: NYCS000015402R01 Doc Title: NYCS000015402,CSS,Centrifugal Pumps,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015143, Centrifugal Pumps,01.287:

L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 01 61 03, Equipment – Basic Requirements, L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 43 21 00, Pumping Equipment – Basic Requirements.

Any exceptions and clarifications to the specifications sections above can be found in submittals:

NYCS000015364, Es and Cs, Section 01 61 03,01.287 and NYCS000015386, Es and Cs, Section 43 21 00,01.287

Pall has taken exceptions and clarifications relevant to the centrifugal pumps proposed.

SSH

S & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS

BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S

TECHNICAL BROCHURE

BSSH R4

LarkinD Text Box

WH172297

Part #: 6SH2N45D2, 256JM.

Special motor: 20HP, TEFC, PREMIUM EFF, 230/460V, 3PH, 3500 RPM with condensation heater and shaft grounding ring.

Mechanical seal: Carbon / Silicon Carbide with EPR elastomers larkind

Document: NYCS000015287R00

Commercial Water Goulds Water Technology

A FULL RANGE OF PRODUCT FEATURES,

UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO

Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced cor-rosion and improved strength and ductility.

Frame Mounted Design:

Flexibility of installation and driver arrangements.

Back Pull-Out Design:

Simplifies maintenance when used with spacer type coupling.

Cast Iron Power Frame:

Rigidly supported, grease lubricated ball bearing assembly.

Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.

Motores de Accio-namiento: Motores de armazón-T NEMA están-dar unifásicos o trifásicos.

Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150.

Diseño de Acople Cer-rado: El diseño compacto ahorra espacio y simpli-fica el mantenimiento.

Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad me-joradas.

Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor.

Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador.

Armazón del Motor de Hierro Fundido: Rígida-mente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .

Mechanical Seal: Stan-dard John Crane Type 21 mechanical seal.

Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase.

Suction and Discharge Flanges: Mate with ANSI class 150 flanges.

Close-Coupled Design:

Compact design saves space and simplifies maintenance.

Goulds Water Technology

PERFORMANCE COVERAGE, 3500 AND 1750 RPM

ALCANCE DE FUNCIONAMIENTO, 3500 Y 1750 RPM

4003002001000 600

40 60 160 180

500 800

1750 RPM

20 80 100 120 140

23SH

27SH

22SH

6SH

25SH

24SH

11SH

10SH

9SH

8SH

5SH

4SH

28SH

7SH

m3/hr

CAPACITY (CAPACIDAD) – U.S. GPM

TO

TA

L D

Y N

A M

IC

H

E A

D (C

A R

G A

D

IN

A M

IC

A

T O

TA

L)

METERS

(METROS)

FEET

(PIES)

4003002001000 600

40 60 160 260 m3/hr

CAPACITY (CAPACIDAD) – U.S. GPM

TO

TA

L D

Y N

A M

IC

H

E A

D (C

A R

G A

D

IN

A M

IC

A

T O

TA

L)

METERS

(METROS)

FEET

(PIES)

500 800

3500 RPM

20 80 100 120 140

1000900 12001100

180 200 220 240

23SH

27SH

22SH

6SH

5SH

8SH

25SH

24SH

11SH

10SH

7SH

9SH

4SH

28SH

LarkinD Line

LarkinD Line

LarkinD Highlight

LarkinD Highlight

Goulds Water Technology

24 SH 1 Q 1 2 A 0 R

Example Product Code, Ejemplo Código del Producto

Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below.

Casing Rotation, Optional R = 3 o’clock B = 6 o’clock L = 9 o’clock NOTE: Rotation when viewed from suction end of pump.

Standard discharge position is 12 o’clock.

Motor Enclosure, Caja del motor

1 = ODP 5 = 3PH, TE PE 9 = 1PH, ODP PE

2 = TEFC 6 = 3PH, XP PE A = 1PH, TE PE

3 = Explosion Proof, Prueba de explosiones 7 = Wash down, Lavado

4 = 3PH, ODP PE 8 = 3PH, WD PE

Motor Voltage, Voltaje del motor 1 = 115/208-230 3 = 230 5 = 208-230/460 7 = 575 2 = 115/230 4 = 230/460 6 = 460 X = Non Std.

HP Rating, Potencia nominal, HP C = ½ F = 1.5 J = 5 M = 15 Q = 30 T = 60 D = .75 G = 2 K = 7.5 N = 20 R = 40 U = 75 E = 1 H = 3 L = 10 P = 25 S = 50 V = 100

Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM 1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/1 2 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3

Material SH = 316L Stainless steel, Acero inoxidable

Pump Size, Tamaño de la Bomba 9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 8 = 2 x 2½ – 8 10 = 1 x 2 – 8 7 = 1½ x 2½ – 8 6 = 2½ x 3 – 6 11 = 1 x 2 – 10 5 = 2 x 2½ – 6 22 = 2½ x 3 – 8 23 = 3 x 4 – 8 24 = 1½ x 2½ – 10 25 = 2 x 2½ – 10 27 = 2½ x 3 – 10 28 = 3 x 4 – 10

SSH S/M-GROUP NUMBERING SYSTEM

SISTEMA DE NUMERACIÓN DEL GRUPO-S/M SSH

Impeller Option Code - For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve.

NOTE: For trimmed impellers, use T for impeller code.

NOTE: Impellers will be trimmed in 1/16” increments only. If you are ordering a trim within 1/16” of the standard impeller, you will receive the standard impeller trim.

* Indicates impellers that can be trimmed

NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with GWT on non-cataloged numbers.

NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con GWT en los números no catalogados.

Frame Options, Opciones de mando Substitute, Description, Substituto Descripción

FRM2

7/8" Imp. Bore, Diámetro interior del impulsor 7/8"

FRM3

1¼" Imp. Bore, Diámetro interior del impulsor 1¼"

Sello Mecánico y Anillo ‘0’ 0 = Estándar aprobado. Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo.

Rotación de la cubierta, opcional R = 3 hora B = 6 hora L = 9 hora NOTA: Rotación cuando está visto del extremo de la succión de la bomba. La posición estándar de la descarga es las 12.

Código del Impulsor Opcional - Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba.

NOTA: Para los impulsores cortados, utilice T para el código del impulsor.

John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21

Seal Code, Código del Sello

Rotary, Rotativo

Stationary, Estacionario

Elastomers, Elastómeros

Metal Parts, Partes Metálicas

Part No., Pieza Número

180-210 Frames, Armazones

250-360 Frames, Armazones

Carbon Sil-Carb

Viton 316 SS, 316 Acero inoxidable

10K27 10K45

2 EPR 10K19 10K20

5 Sil-Carb Sil-Carb Viton 10K64 10K65

Impeller Code, Código del impulsor

Pump Size, Tamaño de la Bomba

9SH

1 x 2-6 Dia.

10SH

1 x 2-8

Dia.

11SH

1 x 2-10

Dia.

4SH

1½ x 2½-6

Dia.

7SH

1½ x 2½-8

Dia.

5SH

2 x 2½-6

Dia.

8SH

2 x 2½-8

Dia.

*6SH

2½ x 3-6

Dia.

*22SH

2½ x 3 – 8

Dia.

*23SH

3 x 4 – 8

Dia.

24SH

1½ x 2½ –

10 Dia.

25SH

2 x 2½

– 10 Dia.

*27SH

2½ x 3

– 10 Dia.

*28SH

3 x 4 – 10

Dia.

A 65⁄8 827⁄64 103⁄32 6¾ 8¼ 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8 B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼ C 511⁄16 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16

D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16

E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16

F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16

G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16

H 43⁄16 611⁄16 67⁄8 J 6½ 6½ K 6 L 5½

NOTA: Los impulsores serán cortados en 1/16 " incrementos solamente. Si usted está pidiendo un ajuste dentro de 1/16 " del impulsor estándar, usted recibirá el ajuste estándar del impulsor.

* Indica los impulsores que pueden ser cortados

LarkinD Text Box Part #: 6SH2N45D2, 256JM

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight larkind

Goulds Water Technology

PERFORMANCE CURVES – 60 HZ, 3500 RPM

CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM

4020 100

250 300

30090

35015010050

A 81/4" DIA.

E 67/8"

B 73/4"

F 63/16"

C 71/2"

D 73/16"

15 HP

20 HP

25 HP

10 HP

EFF%65

656050 10'

13'

16'

21'

Model SSH / 8SH Size (Tamaño) 2 x 21/2 - 8 RPM 3500 Curve (Curva) CN0497R01

METERS

METROS

FEET

PIES

TO

TA

L D

Y N

A M

IC

H

E A

D (C

A R

G A

D

IN

A M

IC

A

T O

TA

L)

(H

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.

NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

8’ NPSHR – FEET (PIES)

m3/hr

Optional Impeller, Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 8¼" 25

B 7¾ 20

C 7½ 20

D 73⁄16 15

E 67⁄8 15

F 63⁄16 10

NOTE: Pump will pass a sphere to ¼" diameter.

NOTA: La bomba pasará una esfera a ¼" diámetro.

Optional Impeller, Impulsor Opcional

Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia

A 75⁄16" 25

B 71⁄8 25

C 615⁄16 20

D 611⁄16 20

E 63⁄8 15

F 61⁄16 15

G 55⁄8 10

NOTE: Pump will pass a sphere to 5⁄16" diameter.

NOTA: La bomba pasará una esfera a 5⁄16" diámetro.

5025 150

400 500

600200100

E 63/8"

A 75/16" DIA.

F 61/16"

B 71/8" C 615/16"

G 55/8"

8'

10'

13'

EFF%60

15'

20'

10 HP

20 HP

25 HP

125100 175

D 611/16"

15 HP

25'

Model SSH / 6SH Size (Tamaño) 21/2 x 3 - 6 RPM 3500 Curve (Curva) CN0500R00

METERS

METROS

FEET

PIES

TO

TA

L D

Y N

A M

IC

H

E A

D (C

A R

G A

D

IN

A M

IC

A

T O

TA

L)

(H

CAPACITY (CAPACIDAD) (Q)

U.S. GPM

NOTE: Not recommended for operation beyond printed H-Q curve.

NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.

7’ NPSHR – FEET (PIES)

m3/hr

LarkinD Line

LarkinD Line larkind Highlight larkind Highlight larkind Highlight

Goulds Water Technology

SSH FRAME MOUNTED – MATERIALS OF CONSTRUCTION

SSH ARMAZÓN MONTADO – MATERIALES DE CONSTRUCCIÓN

SSH CLOSE COUPLED – MATERIALS OF CONSTRUCTION

SSH ACOPLE CERRADO – MATERIALES DE CONSTRUCCIÓN

Item No., Description, Materials, Parte No. Descripción Materiales

100 Casing, Carcasa

101 Impeller, Impulsor

103 Wear ring, Anillo de desgaste 316L SS, 316L acero inox.

184 Seal housing, Alojamiento del sello

126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.

422 Impeller stud, Perno del impulsor Steel, Acero

Impeller key, Carbon steel, Llave del impulsor Acero al carbono

199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.

Casing bolt with nut (casing to adapter), 316L SS, 370 Tornillo de la carcasa con tuerca

316L acero inoxidable (carcasa para adaptador)

Cast iron ASTM A48 CL20, 108 Adapter, Adaptador Hierro fundido ASTM

A48CL20

Hex head cap screw (adapter to motor), Steel SAE 1200 series,371 Tornillo de cabeza hexagonal Acero SAE series 1200 (adaptador para motor)

412A O-ring, Impeller, Anillo en O, impulsor

412F O-ring, shaft sleeve, Anillo en O, camisa del eje Viton

513 O-ring, Anillo 'O'

Drain plug – 3⁄8 BSP, 316L SS, Válvula de drenaje – 3⁄8 BSP 316 acero inoxidable

Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello

Item No., Description, Materials, Parte No. Descripción Materiales

100 Casing, Carcasa

101 Impeller, Impulsor 316L SS, 103 Wear ring, Anillo de desgaste 316L acero inox.

184 Seal housing, Alojamiento del sello

126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.

178 Impeller key, Llave del impulsor Carbon steel, 422 Impeller Stud, Perno del impulsor Acero al carbono

199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.

370 Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS, 408 Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT 316L acero inox.

513 O-ring, Anillo ‘O’ Viton

383 Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello

108 Adapter, Adaptador

228 Bearing frame, Armazón de balineras

134 Bearing cover, Cubierta de balineras

122 Pump shaft, Carbon steel, Eje de la bomba Acero al carbono

168 Ball bearing (inboard), Balineras de bolas (interior)

112 Ball bearing (outboard), Balineras de bolas (exterior)

382 Retaining ring, Anillo de sujeción

Hex head cap screw (adapter to bearing frame), 370B Tornillo de cabeza hexagonal Steel, Acero (adaptador para armazón de balineras)

Hex head cap screw (bearing frame to cover), 370C Tornillo de cabeza hexagonal (armazón de balineras para cubierta)

333A Lip seal, Sello cubierto BUNA-N

193 *Grease fitting, Accesorio de grasa Steel, Acero

123 V-ring deflector, Deflector anillo ‘V’ BUNA-N

* M-Group only

Part No., Pleza Número

10K19 10K20

EPR

Hot Water, 383 Carbon, Silicon 316 SS, Agua Caliente Options, 10K27 10K45 Carbone Carbide, 316 Mild Abrasive, 383 Carburo de Viton

Acero Abrasivo Suave Opciones

10K64 10K65 Sil-Carb.

silicona inoxidable Severe Duty, Deber Severo

Mechanical Seal, Sello Mecánico

John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21

Item, Rotary, Stationary, Elastomers, Parte Rotativo Estacionario Elastómeros

Cast iron ASTM

A48CL20,

Hierro fundido ASTM

A48CL20

Metal Intended Parts, Duty, Partes Servicio Metálicas Propuesto

103 199 422 408 178

100 101 178 108 370

199 422 408 126 371412F

383412A

383100 101 513 370 184 108 228

370B 123 168 112 122382

370C

333A

412F

412A

180-210 250-360 Frames, Frames, Armazones Armazones

LarkinD Line

Line

Goulds Water Technology

(All dimensions in inches and weights in lbs. Do not use for construction purposes.)

(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)

Motor Frame Selections, Selecciones del Armazón del Motor

DISCHARGE

DESCARGA

SUCTION

SUCCIÓN

DC

MAX.G

H-(4) HOLES

H-(4) AGUJEROS

DD X Y Z

143/145 182/184 213/215 254/256 9SH 1 x 2 – 6 5 45⁄8 63⁄8 31⁄8

97⁄8 10½ 11½ —

36.5 10SH 1 x 2 – 8 2 1 55⁄8 5¼ 71⁄8

37⁄8 49.2

11SH 1 x 2 – 10 67⁄8 6¼ 87⁄8 4 10¾ 113⁄8 123⁄8 127⁄8 66 4SH 1½ x 2½ – 6

1½ 5 45⁄8 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 37.7

7SH 1½ x 2½ – 8 2½

55⁄8 5¼ 71⁄8

48.2 5SH 2 x 2½ – 6

5 45⁄8 4 35⁄8 10½

111⁄8

121⁄8 125⁄8 37.9

8SH 2 x 2½ – 8

5¾

77⁄8

54.6 6SH 2½ x 3 – 6 3 2½ 37⁄8 105⁄8 113⁄8 123⁄8 127⁄8 61.8

3⁄8" – 19 BSP

NOTE:

1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.

2. ALL dimensions in inches.

3. Motor dimensions may vary with motor manufacturer.

4. Not for construction purposes.

NOTA:

1. Las bombas se transportarán en des-carga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.

2. TODAS las dimensiones en pulgadas.

3. Las dimensiones puede que varíen con los fabricantes.

4. No para propósitos de construcción.

Pump, Bomba

DC

Max., DC

Máx.

Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM

Suct.*, Disch.*, Succ.* Desc.*

150 lb. Flange, Brida de 150 lib. DIM. “L” (Motor Frame Size)

DIM. “L” (Tamaño del Armazón del Motor) Wt.

(lbs.), Pesos

(libras)

* For use with ANSI class 150 mating flanges.

* Para usar con bridas que casan ANSI clase 150.

ODP* TEFC* ODP* TEFC* ODP* TEFC* ODP* TEFC*

143JM – – – – – – 1 1

145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2

182JM 3 3 5 3 2 2-3 3 3

184JM 5 5 7½ 5 3 – 5 5

213JM 7½ – 10 7½ 5 – 7½ 7½

215JM 10 – 15 10-15 – – – –

254TCZ – – 20 15** – – – –

256TCZ – – 25 20 – – – –

1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos

Motor Horsepower, Potencia del Motor

3500 RPM, 3500 RPM 1750 RPM, 1750 RPM

Motor Frame, Armazón del Motor

AB MAX.

X

D

E E A

DD

P

MAX.

F F B

L

Y Z CREF

DRAIN PLUG

PRIME PLUG

SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS S-GROUP

SSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-S

* Premium efficiency where required by Department of Energy regulations.

* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

** Frame size for 208-230/460 Voltage TEPE motor.

** Talla de capítulo para 208-230/460 el motor del voltaje TEPE.

JM Frame, JM

Armazón

A AB

Max. B D E F G C Max.

H

Dia., H

Diám.

P Max., P Máx.

Motor Wt.

(lbs.)

Peso Motor (lib.)

143JM

6½ 5¾ 6 3½ 2¾

1/8 113/16

11/32 73/16

145JM 2½ 54

182JM

85/8 67/8 6½ 4½ 3¾

2¼ 3/16 134/5

13/32

85/8

184JM

2¾

213JM

9½ 82/5 8 5¼ 4¼ 3/16 1514/25 107/25

215JM 3½ 169

254TCZ

11½ 102/5 11½ 6¼ 5

41/8 7/8 201/20

17/32 1313/50

256TCZ 5 298

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Highlight

LarkinD Text Box

254JM

Goulds Water Technology

SPECIFICATIONS

ESPECIFICACIONES

Capacities to:

1100 GPM (250 m3/hr) at

3500 RPM 775 GPM

(177 m3/hr) at 1750 RPM

Heads to:

525 feet THD (158 m) at

3500 RPM

130 feet THD (40 m) at

1750 RPM

Maximum working pres-sures to: 230 PSI (15 bars)

Maximum temperatures to: 250°F (121°C)

All wetted components of AISI: Type 316L stainless steel material.

Rotation: Clockwise when viewed from motor end.

Enclosed impeller and replaceable wear ring:

for high efficiency and maxi-mum wear life.

Motor (close coupled):

NEMA standard JM shaft open drip-proof*, totally en-closed* and explosion-proof enclosures*, 60 Hz, 1750 or

3500 RPM.

Single phase ODP* (115/230

V) 1750 RPM, 1 – 5 HP.

Three phase ODP*. TEFC*/ Exp. proof* (208 – 230/460 V).

3500 RPM, 2 – 100 HP

1750 RPM, 1 – 25 HP

NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.

Motor (frame mounted):

NEMA standard T-frame open drip-proof*, totally enclosed* and explosion-proof* (three phase only) enclosures 60 Hz, 1750 or

3500 RPM.

Single phase (115/230 V)

1750 RPM, 1 – 5 HP

Three phase (208 – 230/ 460 V)

3500 RPM, 3 – 125 HP

1750 RPM, 1 – 25 HP

NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.

Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.

* Premium efficiency where required by Department of Energy regulations.

Capacidades:

1100 GPM (105 m 3/hr) a

3500 RPM 775 GPM (177

m3/hr) a 1750 RPM

Cargas:

525 pies THD (158 m) a 3500 RPM 130 pies THD (40

m) a 1750 RPM

Presión de trabajo máxi-ma:

230 PSI (15 baras)

Temperatura máxima:

250°F (121°C)

Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L.

Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.

Impulsor encerrado y anillo de desgaste reem-plazable: para alta eficien-cia y máxima durabilidad.

Motor (acople cerrado):

Eje a prueba de goteo* JM estándar NEMA, totalmente encerrado* y recintos a prueba de explosión*, 60 Hz, 1750 ó 3500 RPM.

Unifásicos ODP (115/230 V)

1750 RPM, 1 – 5 HP

Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V).

3500 RPM, 2 – 100 HP

1750 RPM, 1 – 25 HP

NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.

Motor (armazón mon-tado): Armazón abierto T a prueba de goteo* estándar NEMA, totalmente encer-rado* y recintos a prueba de explosión* (trifásicos solamente) 60 Hz, 1750 ó

3500 RPM.

Unifásicos (115/230 V)

1750 RPM, 1 – 5 HP.

Trifásicos (208 – 230/460 V)

3500 RPM, 3 – 125 HP

1750 RPM, 1 – 25 HP

NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.

Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las espe-cificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.

* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.

Product Information Packet

EJMM4106T

20HP,3520RPM,3PH,60HZ,256JM,0936M,TEFC,F

Copyright © All product information within this document is subject to Baldor Electric Company copyright © protection, unless otherwise noted.

LarkinD Text Box SPECIAL MOTOR with condensation heater and shaft grounding ring

LarkinD Text Box Note: This submittal may require revision. Supplier cannot provide motor data sheet until after purchase order.

LarkinD

SPECIAL JUNCTION BOXES: Oversized main junction box and additional junction box for condensation heater.

Product Information Packet: EJMM4106T - 20HP,3520RPM,3PH,60HZ,256JM,0936M,TEFC,F

Part Detail

Revision: T Status: PRD/A Change #: Proprietary: No

Type: AC Prod. Type: 0936M Elec. Spec: 09WGZ601 CD Diagram: CD0005

Enclosure: TEFC Mfg Plant: Mech. Spec: 09P14 Layout: 09LYP014

Frame: 256JM Mounting: F1 Poles: 02 Created Date: 05-06-2010

Base: RG Rotation: R Insulation: F Eff. Date: 03-15-2017

Leads: 9#12 Replaced By:

Literature: Elec. Diagram:

Nameplate NP3441L

CAT.NO. EJMM4106T

SPEC. 09P014Z601G1

HP 20

VOLTS 230/460

AMP 46/23

RPM 3520

FRAME 256JM HZ 60 PH 3

SER.F. 1.15 CODE H DES A CL F

NEMA-NOM-EFF 91 PF 89

RATING 40C AMB-CONT

CC 010A USABLE AT 208V 50

DE 6309 ODE 6208

ENCL TEFC SN

VPWM INVERTER READY

CT6-60H(10:1)VT3-60H(20:1

Parts List

Part Number Description Quantity

SA194418 SA 09P014Z601G1 1.000 EA

RA182005 RA 09P014Z601G1 1.000 EA

37FN3002C02 EXFN, PLASTIC, 6.00 OD, 1.500 ID 1.000 EA

HW1002A63 WASHER, 5/8 HI-COLLAR SPRLCKWASHER 1.000 EA

09CB3002 CB W/1.38 LEAD HOLE FOR 37, 39, 307 & 30 1.000 EA

09GS1000 GASKET-CONDUIT BOX, 1/16 THICK LEXIDE 1.000 EA

10XN2520K12 1/4-20 X.75 GRD 5 2.000 EA

HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 2.000 EA

09EP1300A52 ENDPLATE, MACH 1.000 EA

HW4600B44 V-RING SLINGER 1.500 X 1.810 X .28 VITON 1.000 EA

WD1000B17 T&B CX35TN TERMINAL 1.000 EA

51XW1032A06 10-32 X .38, TAPTITE II, HEX WSHR SLTD S 1.000 EA

09FE1100A14 FREP ASSEMBLY, 09EP1100A14 1.000 EA

XY3816A12 3/8-16 FINISHED NUT 4.000 EA

HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA

HW5100A08 W3118-035 WVY WSHR (WB) 1.000 EA

10XN2520K28 1/4-20 X 1.75" HX HD SCRWGRADE 5, ZINC P 2.000 EA

HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 2.000 EA

10XN2520K36 1/4-20 X 2.25" HX HD SCRWGRADE 5, ZINC P 4.000 EA

HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 4.000 EA

HA3113A02 THRUBOLT 3/8-16 X 16.750 4.000 EA

HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA

09FH4000SP FAN COVER, STAMPED 1.000 EA

HA2081A05 SPACER TUBE, 309 FAN HSG, 2.00 LONG 4.000 EA

Parts List (continued)

Part Number Description Quantity

HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA

XY3816A12 3/8-16 FINISHED NUT 4.000 EA

09CB3501 CONDUIT BOX LID FOR 09CB3001 & 09CB3002 1.000 EA

09GS1013 09 GS FOR 09CB3501 LID - LEXIDE 1.000 EA

51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA

HW2501E22 KEY, 1/4 SQ X 2.500 1.000 EA

LB1115N LABEL,LIFTING DEVICE (ON ROLLS) 1.000 EA

MN416A01 TAG-INSTAL-MAINT no wire (1000/bx) 11/14 1.000 EA

HW4500A05 1669B ALEM/UNIV860 GR FTG X 1.000 EA

HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA

HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA

HA4051A00 PLASTIC CAP FOR GREASE FITTING 1.000 EA

MJ1000A02 GREASE, POLYREX EM EXXON (USe 4824-15A) 0.080 LB

HW4500A03 GREASE FITTING, .125 NPT 1610(ALEMITE) 8 1.000 EA

HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA

HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA

HA4051A00 PLASTIC CAP FOR GREASE FITTING 1.000 EA

HW2500A25 WOODRUFF KEY USA #1008 #BLOW CARBON STEE 1.000 EA

51XB1214A20 12-14X1.25 HXWSSLD SERTYB 1.000 EA

MG1000Y03 MUNSELL 2.53Y 6.70/ 4.60, GLOSS 20, 0.050 GA

85XU0407S04 4X1/4 U DRIVE PIN STAINLESS 2.000 EA

LC0005E02 SPL CONN.DIA./WARN.LABEL(LC0005/LB1119) 1.000 EA

NP3441L ALUM SUPER-E VPWM INVERTER READY UL 1.000 EA

40PA1005 PACKAGING GROUP, 09 STD 1.000 EA

AC Induction Motor Performance Data Record # 31396 - Typical performance - not guaranteed values

Winding: 09WGZ601-R001 Type: 0936M Enclosure: TEFC

Nameplate Data 460 V, 60 Hz:

High Voltage Connection

Rated Output (HP) 20 Full Load Torque 29.6 LB-FT

Volts 230/460 Start Configuration direct on line

Full Load Amps 46/23 Breakdown Torque 111 LB-FT

R.P.M. 3520 Pull-up Torque 39.1 LB-FT

Hz 60 Phase 3 Locked-rotor Torque 49.6 LB-FT

NEMA Design Code B KVA Code H Starting Current 161 A

Service Factor (S.F.) 1.15 No-load Current 7.17 A

NEMA Nom. Eff. 91 Power Factor 89 Lineline Res. @ 25ºC 0.47592 Ω

Rating - Duty 40C AMB-CONT Temp. Rise @ Rated Load 76°C

S.F. Amps Temp. Rise @ S.F. Load 95°C

Locked-rotor Power Factor 29

Rotor inertia 0.92 LB-FT2

Load Characteristics 460 V, 60 Hz, 20 HP

% of Rated Load 25 50 75 100 125 150 S.F.

Power Factor 58 78 86 89 90 90 90

Efficiency 88.9 92.2 92.4 91.7 90.7 89.2 91.1

Speed 3579.6 3561.5 3541.3 3519.5 3495.4 3467.8 3505

Line amperes 9 13 17.7 22.9 28.6 35 26.3

Performance Graph at 460V, 60Hz, 20.0HP Typical performance - Not guaranteed values

LarkinD Line

LarkinD Text Box main junction box, size and location TBD

LarkinD Text Box additional junction box, size and location TBD

LarkinD Rectangle

Rectangle

GRUNDFOS DATA BOOKLET

CR, CRI, CRN

Vertical multistage centrifugal pumps 60 Hz

LarkinD Text Box Document: NYCS000015286R01

LarkinD Text Box

WH172296

Part #: CRN64 1-1-A-G-G-E HQQE Special motor: 10HP, SEVERE DUTY, PREMIUM EFF, 230/460V, 3PH, 3500 RPM with condensation heater Mechanical seal: Silicon Carbide / Silicon Carbide with EPDM elastomers

P ro d u c t in tr o d u c ti o n

CR, CRI, CRN 1

1. Product introduction

This data booklet deals with Grundfos CR, CRI and CRN pumps.

Fig. 1 CR, CRI and CRN pumps

Features and benefits Grundfos CR, CRI, CRN pumps are vertical multistage centrifugal pumps. The in-line design enables the pump to be installed in a horizontal one-pipe system where the suction and discharge ports are in the same horizontal plane and have the same pipe dimensions.

This design provides a more compact pump design and pipework.

Grundfos CR pumps come with various pump sizes and various numbers of stages to provide the flow and the pressure required.

CR pumps are suitable for a variety of applications from pumping of potable water to pumping of chemicals. The pumps are therefore used in a wide variety of pumping systems where the performance and material of the pump meet specific demands.

The CR pumps consist of two main components: the motor and the pump unit. The motor on a CR pump is a heavy-duty Grundfos specified motor.

The pump unit consists of optimized hydraulics, various types of connections, an outer sleeve, a top and various other parts.

CR pumps are available in various material versions according to the pumped liquid.

Pump The CR pump is a non-self-priming, vertical multistage centrifugal pump. The pumps are available with a Grundfos standard motor.

The pump consists of a base and a pump head. The chamber stack and the outer sleeve are secured between the pump head and the base by means of staybolts. The base has suction and discharge ports on the same level (in-line).

All pumps are equipped with a maintenance-free mechanical shaft seal of the cartridge type.

Fig. 2 CR pump

CR pump with ANSI/NSF 61 listing is available. See UL file MH26400 or contact Grundfos.

Motor

Grundfos standard motors - ML and Baldor® motors

CR, CRI and CRN pumps are fitted with a Grundfos specified motor. The motors are all heavy-duty 2-pole, NEMA C-face motors.

T M

G R

G

R

Motor

Coupling

Pump head

Outer sleeve

Staybolts

Base plate

Base

Impellers

Shaft seal (Cartridge type)

P ro d u c t in tro d u c tio n

CR, CRI, CRN1

Electrical data

* 1-10 Hp ML motors are premium efficiency as standard.

Optional motors

The Grundfos standard range of motors covers a wide variety of application demands. However, for special applications or operating conditions, custom-built motor solutions can be provided.

For special applications or operating conditions, Grundfos offers custom-built motors such as:

• explosion proof motors

• motors with anti-condensation heating unit

• low-noise motors

• premium efficiency motors

• motors with thermal protection.

Motor protection

Single-phase Grundfos specified motors up to 7.5 Hp have a built-in thermal overload switch.

Three-phase motors must be connected to a motor starter in accordance with local regulations.

Terminal box positions As standard the terminal box is mounted on the suction side of the pump.

Fig. 3 Terminal box positions

Viscosity The pumping of liquids with densities or kinematic viscosities higher than those of water will cause a considerable pressure drop, a drop in the hydraulic performance and a rise in the power consumption.

In such situations, the pump should be fitted with a larger motor. If in doubt, contact Grundfos.

Ambient temperature and altitude If the ambient temperature exceeds the maximum temperature limits of the pump or the pump is installed at an altitude exceeding the altitude values in the chart below, the motor must not be fully loaded due to the risk of overheating.

Overheating may result from excessive ambient temperatures or the low density and consequently low cooling effect of the air at high altitudes. In such cases, it may be necessary to use a motor with a higher rated output (P2).

Fig. 4 Relationship between motor output (P2) and ambient temperature/altitude

Legend

Example: From fig. 4 it appears that P2 must be reduced to 88 % when a pump with a NEMA premium-efficiency ML motor is installed 15,584 ft (4750 m) above sea level. At an ambient temperature of 167 °F (75 °C), P2 of a standard-efficiency motor must be reduced to 74 % of rated output.

In cases where both the maximum temperature and the maximum altitude are exceeded, the derating factors must be multiplied. Example: 0.89 x 0.89 = 0.79.

Mounting designation NEMA

Insulation class F & B

Efficiency class* Energy efficient Premium efficiency - on request for 15 Hp and above

Enclosure class TEFC - Totally Enclosed Fan Cooled (Grundfos standard) ODP - Open Drip Proof - on request

60 Hz standard voltages 1 x 115/208-230 V 3 x 208-230/460 V 3 x 575 V

Approvals

The motors are rated for:

Baldor ML

T M

RU RUC US

Stellung 6 Stellung 9 Stellung 12 Stellung 3Position 6 Standard

Position 9 Position 12 Position 3

T M

Pos. Description

1 NEMA energy efficient motors

2 NEMA premium-efficiency motors

60 80 100 120 140 160 180 T [°F]

P2

3280 7382 11483 15584 ft

Id e n ti fi c a ti o n

CR, CRI, CRN 5

5. Identification

Type key

CR, CRI, CRN

Codes

1) If a pump incorporates more than two pump versions, the code for the pump version is X.

X also indicates special pump versions not listed above.

Example CR 32 (s) -4 -2 -A -G -G -E - HQQE

Type range:

CR, CRI, CRN

Nominal flow rate [m3/h]

All impellers with reduced diameter (applies only to CR, CRI, CRN 1s)

Number of impellers

Number of reduced diameter impellers (CR, CRN 32, 45, 64, 90, 120, and 150)

Code for pump version

Code for pipe connection

Code for materials

Code for rubber parts

Code for shaft seal

Example A -G -A -E -H QQ E

Pump version1)

A Basic version

B Oversize motor

E Certificate/approval

F CR pump for high temperatures (air-cooled top assembly)

H Horizontal version

HS

High-pressure pump with high speed MLE motor

I Different pressure rating

J Pump with different max speed

K Pump with low NPSH

M Magnetic drive

N Fitted with sensor

P Undersize motor

R Horizontal version with bearing bracket

SF High pressure pump

T Over size motor (two flange sizes bigger)

X Special version

Pipe connection

A Oval flange Rp thread

B Oval flange NPT thread

CA FlexiClamp (CRI, CRN 1, 3, 5, 10, 15, 20)

CX Triclamp (CRI, CRN 1, 3, 5, 10, 15, 20)

F DIN flange

G ANSI flange

J JIS flange

N Changed diameter of ports

P PJE coupling

X Special version

Materials

A Basic version

D Carbon-graphite filled PTFE (bearings)

G Wetted parts AISI 316

GI All parts stainless steel, wetted parts AISI 316

I Wetted parts AISI 304

II All parts stainless steel, wetted parts AISI 304

K Bronze (bearings)

S SiC bearings + PTFE neck rings

X Special version

Code for rubber parts

E EPDM

F FXM

K FFKM

V FKM

Shaft seal

A O-ring seal with fixed driver

B Rubber bellows seal

E Cartridge seal with O-ring

H Balanced cartridge seal with O-ring

K Metal bellows cartridge seal

O Double seal, back-to-back

P Double seal, tandem

X Special version

B Carbon, synthetic resin-impregnated

H Cemented tungsten carbide, embedded (hybrid)

Q Silicon carbide

U Cemented tungsten carbide

X Other ceramics

E EPDM

F FXM

K FFKM

V FKM

Example A -G -A -E -H QQ E larkind Text Box

WH172296

CRN 64-1-1-AGGE-HQQE

larkind Rectangle larkind Text Box

CRN 64-1-1

larkind Rectangle larkind Rectangle larkind Rectangle larkind Rectangle larkind Text Box

AGGE HQQE

larkind Text Box

AGGE HQQE

larkind Rectangle larkind Rectangle larkind Text Box

AGGE HQQE

larkind

QQ Silicon carbide / Silicon carbide

C o n s tr u c ti o n

CR, CRI, CRN 6

CR 32, 45, 64 and 90

Sectional drawing

Materials: CR

CRN 32, 45, 64 and 90

Sectional drawing

Materials: CRN

1) Stainless steel available on request.

T M

T M

Pos. Designation Materials AISI/ASTM

1 Pump head Cast iron

EN-GJS-500-7

ASTM 80-55-06

2 Motor stool Cast iron

EN-GJL-200

ASTM 25B

3 Shaft Stainless steel AISI 431

4 Impeller Stainless steel AISI 304

5 Chamber Stainless steel AISI 304

6 Sleeve Stainless steel AISI 304

7 O-ring for sleeve EPDM or FKM

8 Base Cast iron

EN-GJS-500-7

ASTM 80-55-06

9 Neck ring Carbon-graphite-filled

PTFE

10 Shaft seal

11 Bearing ring SiC/SiC

12 Flange ring Ductile iron A 65-45-12

Rubber parts EPDM or FKM

T M

T M

Pos. Designation Materials AISI/ASTM

1 Pump head Stainless steel CF 8M equal to

AISI 316

2 Motor stool Cast iron

EN-GJL-2001) ASTM 25B

3 Shaft Stainless steel

4 Impeller Stainless steel AISI 316

5 Chamber Stainless steel AISI 316

6 Sleeve Stainless steel AISI 316

7 O-ring for sleeve EPDM or FKM

8 Base Stainless steel CF 8M equal to

AISI 316

9 Neck ring Carbon-graphite-filled

PTFE

10 Shaft seal

11 Bearing ring SiC/SiC

12 Base plate Cast iron

EN-GJS-500-71) ASTM 88-55-06

Flange ring Ductile iron1) A 65-45-12

Rubber parts EPDM or FKM larkind Line

O p e ra tin g c o n d itio n s

CR, CRI, CRN7

Working and inlet pressure

Max. working pressure and temperature range

Oval flange

T M

Max.

working pressure

[psi]

Liquid temp.

range [°F]

CR, CRI, CRN 1s 232 -4 to +248

CR, CRI, CRN 1 232 -4 to +248

CR, CRI, CRN 3 232 -4 to +248

CR, CRI, CRN 5 232 -4 to +248

CR 10-1 → CR 10-6 145 -4 to +248

CRI, CRN 10-1 → CRI, CRN 10-10 232 -4 to +248

CR 15-1 → CR 15-5 145 -4 to +248

CRI, CRN 15-1 → CRI, CRN 15-8 232 -4 to +248

CR 20-1 → CR 20-5 145 -4 to +248

CRI, CRN 20-1 → CRI, CRN 20-7 232 -4 to +248

ANSI, Clamp, PJE

T M

Max.

working pressure

[psi]

Liquid temp.

range [°F]

CR, CRI, CRN 1s 362 -4 to +248

CR, CRI, CRN 1 362 -4 to +248

CR, CRI, CRN 3 362 -4 to +248

CR, CRI, CRN 5 362 -4 to +248

CR, CRI 10-1 → 10-10 232 -4 to +248

CR, CRI 10-12 → 10-17 362 -4 to +248

CRN 10 (all stages) 362 -4 to +248

CR, CRI 15-1 → 15-8 232 -4 to +248

CR, CRI 15-9 → 15-12 362 -4 to +248

CRN 15 (all stages) 362 -4 to +248

CR, CRI 20-1 → 20-7 232 -4 to +248

CR, CRI 20-8 → 20-10 362 -4 to +248

CRN 20 (all stages) 362 -4 to +248

CR, CRN 32-1-1 → 2-5 232 -22 to +248

CR, CRN 32-6-2 → 32-11-2 435 -22 to +248

CR, CRN 45-1-1 → 45-4-2 232 -22 to +248

CR, CRN 45-4-1 → 45-8-1 435 -22 to +248

CR, CRN 64-1-1 → 64-3 232 -22 to +248

CR, CRN 64-4-2 → 64-5-2 435 -22 to +248

CR, CRN 90-1-1 → 90-3 232 -22 to +248

CR, CRN 90-4-2 → 90-4-1 435 -22 to +248

CR, CRN 120-1-1 → 120-5-1 435 -22 to +248

CR, CRN 150-1-1 → 150-4-1 435 -22 to +248

LarkinD Rectangle

LarkinD Line e ra ti n g c o n d it io n s

CR, CRI, CRN 7

Operating range of the shaft seal The operating range of the shaft seal depends on operating pressure, pump type, type of shaft seal and liquid temperature. The following curves apply to clean water and water with anti-freeze liquids. For selecting the right shaft seal, see Pumped liquids on page 13.

CR 1s - CR 20

Fig. 5 Operating range of standard shaft seals for CR 1s - CR 20

CR 32 - CR 150 (3.0-60 Hp)

Fig. 6 Operating range of standard shaft seals for CR 32 - CR 150 (3.0-60 Hp)

CR 120 - CR 150 (75-100 Hp)

Fig. 7 Operating range of standard shaft seals for CR 120 - CR 150 (75-100 Hp)

Note: TC= tungsten carbide

See section Lists of variants - on request on page 77, in case of extreme temperatures:

• low temperatures down to -40 °F or

• high temperatures up to +356 °F.

T M

T M

T M

-40-80 0 40 80 120 160 200 240 t [°F ]

[psi] p

-40 -20-60 0 20 40 60 80 100 t [°C ]

[bar] p

HQQE

HQQV

HQQE

H Q

Q E

-40 0 40 80 120 160 200 240 t [°F ]

[ps i] p

-40 -20 0 20 40 60 80 100 t [°C ]

[bar] p

HQQE

HUBE / HUBV HUBE

H Q

Q E

HQQE / HQQV

HQQE

HBQEH

Q

Q E

H Q

Q E

H Q

Q

V HQQE/V

HBQE/V

-40-80 0 40 80 120 160 200 240 t [°F]

-40 -20-60 0 20 40 60 80 100 t [°C]

[psi] p

[bar] p

Shaft seal

Description Max. temp. range

[°F]

HQQE

O-ring (cartridge) (balanced seal), SiC/SiC, EPDM

-40 °F to +248 °F

HBQE

O-ring (cartridge) (balanced seal), Carbon/SiC, EPDM

+32 °F to +248 °F

HBQV

O-ring (cartridge) (balanced seal), Carbon/SiC, FKM

+32 °F to +194 °F

HQQV

O-ring (cartridge) (balanced seal), SiC/SiC, FKM

-4 °F to +194 °F

HUBE

O-ring (cartridge) (balanced seal), TC/carbon, EPDM

+32 °F to +248 °F

HUBV

O-ring (cartridge) (balanced seal), TC/carbon, FKM

+32 °F to +194 °F

LarkinD Line

LarkinD Line

LarkinD Line

LarkinD Line e ra tin g c o n d itio n s

CR, CRI, CRN7

Maximum inlet pressure The following table shows the maximum permissible inlet pressure. However, the current inlet pressure + the pressure against a closed valve must always be lower than the maximum permissible operating pressure.

If the maximum permissible operating pressure is exceeded, the bearing in the motor may be damaged and the life of the shaft seal reduced.

Example of operating and inlet pressures

The values for operating and inlet pressures shown in the tables must not be considered individually but must always be compared, see the following examples:

Example 1:

The following pump type has been selected: CR 3-10 A-A-A

Max. operating pressure: 232 psi

Max. inlet pressure: 145 psi

Discharge pressure against a closed valve: 139.2 psi, see page 43.

This pump is not allowed to start at an inlet pressure of 145 psi, but at an inlet pressure of 232.0 - 139.2 =

92.8 psi.

Example 2:

The following pump has been selected: CR 10-2 A-GJ- A

Max. operating pressure: 232 psi

Max. inlet pressure: 116 psi

Discharge pressure against a closed valve: 42 psi (97 ft), see page 49.

This pump is allowed to start at an inlet pressure of 116 psi, as the discharge pressure is only 42 psi, which results in an operating pressure of 116 + 42 = 158 psi.

On the contrary, the max. operating pressure of this pump is limited to 158 psi, as a higher operating pressure will require an inlet pressure of more than 116 psi.

In case the inlet or operating pressure exceeds the pressure permitted, see section Lists of variants - on request on page 77.

Pump type Stages Max.

[psi (bar)]60 Hz 50 Hz

CR, CRI, CRN 1s 2-27 2-36 145 (10)

CR, CRI, CRN 1 2-25 2-36 145 (10)

27 217 (15)

CR, CRI, CRN 3 2-17 2-29 145 (10)

19-25 31-36 217 (15)

CR, CRI, CRN 5 2-9 3-16 145 (10)

10-24 18-36 217 (15)

CR, CRI, CRN 10 1-5 1-6 116 (8)

6-17 7-22 145 (10)

CR, CRI, CRN 15 1-2 1-3 116 (8)

3-12 4-17 145 (10)

CR, CRI, CRN 20 1 1-3 116 (8)

2-10 4-17 145 (10)

CR, CRN 32 1-1 - 2 1-1 - 4 58 (4)

3-2 - 6 5-2 - 10 145 (10)

7-2 - 11-2 11-14 217 (15)

CR, CRN 45 1-1 - 1 1-1 - 2 58 (4)

2-2 - 3 3-2 - 5 145 (10)

4-2 - 8-1 6-2 - 13-2 217 (15)

CR, CRN 64 1-1 1-1 - 2-2 58 (4)

1 - 2-1 2-1 - 4-2 145 (10)

2 - 5-2 4-1 - 8-1 217 (15)

CR, CRN 90 1-1 - 1 58 (4)

1-1 - 1 2-2 - 3-2 145 (10)

2-2 - 4-1 3-6 217 (15)

CR, CRN 120 1-1 - 1 1 - 2-1 145 (10)

2-2 - 3 2 - 5-1 217 (15)

4-1 - 5-1 6-1 - 7 290 (20)

CR, CRN 150 1-1 1-1 - 1 145 (10)

1-2 2-1 - 4-1 217 (15)

3-2 - 4-1 5-2 - 6 290 (20)

LarkinD Rectangle

Company name:

Created by:

Phone:

Date: 4/24/2017

Printed from Grundfos Product Center [2017.01.060]

97744287 CRN 64-1-1 60 Hz H [ft]

Q [US gpm]0 50 100 150 200 250 300 350 400 eta

CRN 64-1-1, 60Hz

Pumped liquid = Water Liquid temperature during operation = 68 °F Density = 62.29 lb/ft³

P

[HP]

NPSH

[ft]

P1

P2

1/1

Quotation 1002596524 PALL ADVANCED SEPARATIONS SYSTEMS / RE: RE: Request call - Larkin at Pall

Position: 20 97744287 CRN64-1-1 A-G-G-E-HQQE 3x230/460 60 HZ Curve larkind Text Box Metric larkind Text Box

T c h n ic a l d a ta

10CR, CRI, CRN Technical data

CRN 64

1) Weights are based on pump with TEFC motor (see price list for individual weights).

All dimensions in inches unless otherwise noted.

T M

Pump type P2

[Hp] Ph.

ANSI dimensions [inch (mm)]

Ship. wt.1)

[lbs (kg)]B1

TEFC ODP

D1 D2 B1+B2 D1 D2 B1+B2

CRN 64-1-1 10

1 22.09 (562) 10.23 (260) 10.30 (262) 38.16 (970) - - - 269 (123)

3 22.09 (562) 10.24 (261) 6.26 (160) 36.82 (936) - - - 253 (115)

CRN 64-1 15 3 26.42 (672) 12.36 (314) 8.00 (204) 44.96 (1142) 10.62 (270) 7.33 (187) 42.73 (1086) 349 (159)

CRN 64-2-2 20 3 29.69 (755) 12.36 (314) 8.00 (204) 48.23 (1226) 11.50 (293) 8.92 (227) 49.38 (1255) 364 (166)

CRN 64-2-1 20 3 29.69 (755) 12.36 (314) 8.00 (204) 48.23 (1226) 11.50 (293) 8.92 (227) 49.38 (1255) 364 (166)

CRN 64-2 25 3 29.69 (755) 12.36 (314) 8.00 (204) 52.08 (1323) 11.50 (293) 8.94 (228) 50.50 (1283) 357 (162)

CRN 64-3-2 30 3 32.91 (836) 12.36 (314) 8.00 (204) 55.30 (1405) 11.50 (293) 8.94 (228) 54.72 (1390) 432 (196)

CRN 64-3-1 40 3 32.91 (836) 15.32 (390) 13.11 (333) 56.10 (1425) 13.25 (337) 12.21 (311) 56.16 (1427) 625 (284)

CRN 64-3 40 3 32.91 (836) 15.32 (390) 13.11 (333) 56.10 (1425) 13.25 (337) 12.21 (311) 56.16 (1427) 625 (284)

CRN 64-4-2 40 3 36.18 (919) 15.32 (390) 13.11 (333) 59.37 (1508) 13.25 (337) 12.21 (311) 59.43 (1510) 625 (284)

CRN 64-4-1 50 3 36.18 (919) 16.88 (429) 14.12 (359) 63.99 (1626) 13.25 (337) 12.21 (311) 58.93 (1497) 678 (308)

CRN 64-4 50 3 36.18 (919) 16.88 (429) 14.12 (359) 63.99 (1626) 13.25 (337) 12.21 (311) 58.93 (1497) 678 (308)

CRN 64-5-2 60 3 39.41 (1002) 19.00 (483) 14.90 (379) 70.20 (1784) 15.12 (385) 13.19 (336) 65.54 (1665) 868 (394) larkind Rectangle larkind Line larkind Line larkind Rectangle larkind Rectangle larkind Rectangle larkind Rectangle larkind Line

Product Information Packet

Grundfos Pumps Mfg. Corp.

07H409W279G1

10HP,3525RPM,3PH,60HZ,213TC,0738M,TEFC,F

Copyright © All product information within this document is subject to Baldor Electric Company copyright © protection, unless otherwise noted.

LarkinD Text Box SPECIAL MOTOR: Severe Duty with condensation heater.

LarkinD Text Box Note: This submittal may require revision. Supplier cannot provide motor data sheet until after purchase order.

LarkinD

SPECIAL JUNCTION BOXES: Oversized main junction box and additional junction box for condensation heater.

Product Information Packet: 07H409W279G1 - 10HP,3525RPM,3PH,60HZ,213TC,0738M,TEFC,F

Part Detail

Revision: AK Status: PRD/A Change #: Proprietary: Yes

Type: AC Prod. Type: 0738M Elec. Spec: 07WGW279 CD Diagram: CD0005

Enclosure: TEFC Mfg Plant: Mech. Spec: 07H409 Layout: 07LYH409

Frame: 213TC Mounting: F1 Poles: 02 Created Date:

Base: N Rotation: R Insulation: F Eff. Date: 03-02-2016

Leads: 9#16 Replaced By:

Literature: Elec. Diagram:

Nameplate NP1259L

CAT.NO. 85600H22

SPEC. 07H409W279G1

HP 10

VOLTS 208-230/460

AMP 24.8-23.8/11.9

RPM 3525

FRAME 213TC HZ 60 PH 3

SER.F. 1.15 CODE K DES B CL F

NEMA-NOM-EFF 91 PF 93

RATING 40C AMB-CONT

CC 010A USABLE AT 208V

DE 6309 ODE 6206

ENCL TEFC SN

SFA 28.2-26.6/13.3

Parts List

Part Number Description Quantity

SA021473 SA 07H409W279G1 1.000 EA

RA017525 RA 07H409W279G1 1.000 EA

36FN3000C02 EXFN, PLASTIC, 5.25 OD, 1.175 ID 1.000 EA

HA6283A01 SP'L EYE BOLT BRACKET FOR 306 & 307 MTRS 2.000 EA

10XN3816A12 3/8-16 X 3/4 HEX HD CAP SCREW 2.000 EA

HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 2.000 EA

09CB3000SP CONDUIT BOX CAST 1.000 EA

09GS1000SP GASKET-CONDUIT BOX, 1/16 THICK LEXIDE 1.000 EA

51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA

WD1000B17 T&B CX35TN TERMINAL 1.000 EA

11XW1032G06 10-32 X .38, TAPTITE II, HEX WSHR SLTD U 1.000 EA

37FE1100A89 FR ENDPLATE ASSEMBLY FOR ROUTING 1.000 EA

HW4500A01 1641B(ALEMITE)400 UNIV, GREASE FITT 1.000 EA

HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA

HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA

HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA

HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA

10XN2520A36 1/4-20X 2 1/4 HEX HD X 4.000 EA

HW5100A06 W2420-025 WVY WSHR (WB) 1.000 EA

37PE1302A22 PUEP ASSEMBLY FOR ROUTING 1.000 EA

HW4500A01 1641B(ALEMITE)400 UNIV, GREASE FITT 1.000 EA

HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 4.000 EA

HA3104A32 THRUBOLT- 5/16-18 X12.750 4.000 EA

XY3118A12 5/16-18 HEX NUT DIRECTIONAL SERRATION 4.000 EA

Parts List (continued)

Part Number Description Quantity

51XB1214A20 12-14X1.25 HXWSSLD SERTYB 1.000 EA

07FH4007SP IFC FANCOVER, PRIMED 1.000 EA

51XW1032A06 10-32 X .38, TAPTITE II, HEX WSHR SLTD S 3.000 EA

09CB3500SP CONDUIT BOX LID, CAST 1.000 EA

09GS1001 GASKET-CONDUIT BOX LID, 1/16 THICK LEXID 1.000 EA

51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA

HW2501F21 KEY, 5/16 SQ X 2.375 1.000 EA

HA7000A02 KEY RETAINER RING, 1 1/8 DIA, 1 3/8 DIA 1.000 EA

85XU0407S04 4X1/4 U DRIVE PIN STAINLESS 2.000 EA

LB1182 WARNING LABEL FOR MOTORS WITH EYENUTS 1.000 EA

MJ1000A02 GREASE, POLYREX EM EXXON (USe 4824-15A) 0.050 LB

MG1000L07 RAL9005, SAFETY/JET BLACK, GLOSS 15 +/-5 0.036 GA

LB1119N WARNING LABEL 1.000 EA

LC0005 CONN.DIA.,TY M,9-LD,DUAL VOLT,REVERSING 1.000 EA

NP1259L ALUM SUPER-E UL CSA-EEV CC NEMA PREMIUM 1.000 EA

07PA1011 PKG GRP, 07 CAST IRON PK1181 1.000 EA

07PA1095 PKG GRP, VER 07 CAST IRON 1.000 EA

PK5535A01 MODIFIED STD EURO PALLET 47-1/4 X 31-1/2 0.500 EA

MN416A01 TAG-INSTAL-MAINT no wire (1000/bx) 11/14 1.000 EA

LB1417 LABEL CARTON 6X4 PERFORATED BLANK ROLLS 1.000 EA

AC Induction Motor Performance Data Record # 46228 - Typical performance - not guaranteed values

Winding: 07WGW279-R018 Type: 0738M Enclosure: TEFC

Nameplate Data 460 V, 60 Hz:

Single Voltage Motor

Rated Output (HP) 10 Full Load Torque 15 LB-FT

Volts 208-230/460 Start Configuration direct on line

Full Load Amps 24.8-23.8/11.9 Breakdown Torque 66 LB-FT

R.P.M. 3525 Pull-up Torque 33.5 LB-FT

Hz 60 Phase 3 Locked-rotor Torque 37.5 LB-FT

NEMA Design Code B KVA Code K Starting Current 112 A

Service Factor (S.F.) 1.15 No-load Current 4.2 A

NEMA Nom. Eff. 91 Power Factor 93 Lineline Res. @ 25ºC 0.781 Ω

Rating - Duty 40C AMB-CONT Temp. Rise @ Rated Load 43°C

S.F. Amps 28.2-26.6/13.3 Temp. Rise @ S.F. Load 52°C

Locked-rotor Power Factor 34

Rotor inertia 0.347 LB-FT2

Load Characteristics 460 V, 60 Hz, 10 HP

% of Rated Load 25 50 75 100 125 150 S.F.

Power Factor 53 75 85 89 90 91 90

Efficiency 85.5 90.2 91.6 91.2 91 90 91.1

Speed 3579 3560 3540 3519 3498 3474 3506

Line amperes 5.3 7 9.2 11.6 14.3 17.1 13.2

Performance Graph at 460V, 60Hz, 10.0HP Typical performance - Not guaranteed values

LarkinD Text Box main junction box, size and location TBD

LarkinD Text Box additional junction box, size and location TBD

LarkinD Rectangle

LarkinD Line

Submittal Data

PROJECT:

REPRESENTATIVE:

ENGINEER:

CONTRACTOR:

UNIT TAG:

TYPE OF SERVICE:

SUBMITTED BY:

APPROVED BY:

ORDER NO.:

QUANTITY:

DATE:

DATE:

DATE:

Product photo could vary from the actual product

CRN 10-1 A-FGJ-A-E-HQQE

Vertical, multistage centrifugal pump with suction and discharge ports on same the level. Pump materials in contact with the liquid are in high-grade stainless steel (EN 1.4401)

(AISI 316)

Conditions of Service

Flow:

Head:

Efficiency:

Liquid: Water Temperature: 68 °F NPSH required: ft Viscosity:

Specific Gravity: 1.000

Pump Data

Max pressure at stated temperature: 363 psi / 250 °F Liquid temperature range: -4 .. 248 °F Maximum ambient temperature: 104 °F Approvals: CURUS Shaft seal: HQQE Product number: On request

Motor Data

Rated power - P2: 0.75 HP Rated voltage: 115/208-230 V Main frequency: 60 Hz Enclosure class: 54 Dust/Splashing Insulation class: B Motor protection: NONE Motor type: BALDOR

H [ft]

Q [US gpm]0 5 10 15 20 25 30 35 40 45 50 55 60 65 eta

CRN 10-1, 60Hz

P2

[HP]

0.0

0.2

0.4

0.6

NPSH

[ft]

1/8

LarkinD Text Box

NYCS000015351R00

LarkinD Text Box

WH172339

Part #: CRN10-1-A-FGJ-A-E-HQQE

0.75HP SEVERE DUTY

115/230, 1PH, 3500 RPM

Mechanical seal: Silicon Carbide / Silicon Carbide with EPDM elastomers

Id n ti fi c a ti o n

CRE, CRIE, CRNE 7

7. Identification

Type key

Key to codes

* Option. See the CR "Custom-built pumps" data booklet available on Grundfos Product Center. See QR code or link below.

http://net.grundfos.com/qr/i/96486346

Shaft sea

Example CR E 32 s -4 -2 -A -F -G -E -HQQE

Type range:

CR, CRI, CRN, CRT

Pump with integrated frequency converter

Flow rate [m3/h]

Undersize impeller (all impellers) CR 1s, CRI 1s, CRN 1s

Number of impellers

Number of reduced-diameter impellers

CR, CRE, CRN, CRNE 32, 45, 64

Code for pump version

Code for pipe connection

Code for materials

Code for rubber parts

Code for shaft seal

Code Description

Pump version

A Basic version

B Oversize motor

C CR compact

D Pump with pressure intensifier*

E Pump with certificate

F Pump for high temperatures (with air-cooled top)

G E-pump without control panel

H Horizontal version

I Different pressure rating

J E-pump with a different maximum speed

K Pump with low NPSH

L Pump including Grundfos CUE and certificate

M Magnetic drive

N With sensor

O Cleaned and dried

P Undersize motor

Q High-pressure pump with high-speed MGE motor*

R Belt driven pump

S High-pressure pump

T Thrust handling device*

U ATEX approved pump

V Cascade function

W Deep-well pump with ejector*

X Special version

Y Electropolished

Z Pumps with bearing flange

Pipe connection

A Oval flange

B NPT thread

CA FlexiClamp

CX Triclamp*

F DIN flange

FC DIN 11853-2 flange (collar flange)

FE EN 1092-1, type E

G ANSI flange

J JIS flange

N Changed diameter of ports

P PJE coupling (Victaulic type)

X Special version

Materials

A Basic version

B Tungsten carbide / Tungsten carbide

C Carbon free pump

D Carbon-graphite filled PTFE (bearings)/Tungsten carbide

E Pickled and passivated (Only Japan)

H Flanges and…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .