COVER PAGE OF SELLER’S SUBMITTAL
City Name: Hanford, WA - MSA
Pall Project No.: 01.000287
Job Number: Project L-897, Subcontract 70816
Task Register 6 (Task 1 – VI Submittal Package)
To: (Contractor)
Mission Support Alliance, LLC (MSA)
PO Box 650
Richland, WA 99352
From: (Subcontractor)
Pall Water
A Division of Pall Corporation
839 State Route 13
Cortland, NY 13045
Patty Willis
Phone: 607-758-1699
Name of Project: Hanford, WA, Central Plateau WTF
Pall Document Number: NYCS000015143 Rev: 00
Description of Item: Centrifugal Pumps
Specification Section: 01 61 03 and 43 21 00
Deviations: See document NYCS000015364 and NYCS000015386
INDEX:
Page 1: Cover Page Information
Page 2: Revision History and Approvals
Page 3: Tab 1 - NYCS000015402,CSS,Centrifugal Pumps,01.287
Pages 4-20 Tab 2 - NYCS000015287,Goulds,6SH,20HP,3500,460V,PE,256JM,CH,GR, WH172297
Pages 21-40 Tab 3 - NYCS000015286,Grundfos,CRN64-1-1,10HP,3500,460V,PE,213TC,GH, WH172296
Pages 41-45: Tab 4 - NYCS000015351,Grundfos,CRN10-1,0.75HP,3500rpm,120V,SDM, WH1722339
Date: 12/19/2019
PALL ADVANCED SEPARATIONS SYSTEMS
DIVISION OF PALL CORPORATION, CORTLAND, NY
Rev Name Date Created By
Approved By
Created By
Approved By
Created By
Approved By
Created By
Approved By
Revision Description
Title
Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.
Doc Number: NYCS000015402R01 Doc Title: NYCS000015402,CSS,Centrifugal Pumps,01.287.docx
Components Specification Sections
The following specification sections are relevant to the approval of submittal NYCS000015143, Centrifugal Pumps,01.287:
L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 01 61 03, Equipment – Basic Requirements, L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 43 21 00, Pumping Equipment – Basic Requirements.
Any exceptions and clarifications to the specifications sections above can be found in submittals:
NYCS000015364, Es and Cs, Section 01 61 03,01.287 and NYCS000015386, Es and Cs, Section 43 21 00,01.287
Pall has taken exceptions and clarifications relevant to the centrifugal pumps proposed.
SSH
S & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS
BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S
TECHNICAL BROCHURE
BSSH R4
LarkinD Text Box
WH172297
Part #: 6SH2N45D2, 256JM.
Special motor: 20HP, TEFC, PREMIUM EFF, 230/460V, 3PH, 3500 RPM with condensation heater and shaft grounding ring.
Mechanical seal: Carbon / Silicon Carbide with EPR elastomers larkind
Document: NYCS000015287R00
Commercial Water Goulds Water Technology
A FULL RANGE OF PRODUCT FEATURES,
UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO
Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced cor-rosion and improved strength and ductility.
Frame Mounted Design:
Flexibility of installation and driver arrangements.
Back Pull-Out Design:
Simplifies maintenance when used with spacer type coupling.
Cast Iron Power Frame:
Rigidly supported, grease lubricated ball bearing assembly.
Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.
Motores de Accio-namiento: Motores de armazón-T NEMA están-dar unifásicos o trifásicos.
Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150.
Diseño de Acople Cer-rado: El diseño compacto ahorra espacio y simpli-fica el mantenimiento.
Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad me-joradas.
Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor.
Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador.
Armazón del Motor de Hierro Fundido: Rígida-mente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .
Mechanical Seal: Stan-dard John Crane Type 21 mechanical seal.
Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase.
Suction and Discharge Flanges: Mate with ANSI class 150 flanges.
Close-Coupled Design:
Compact design saves space and simplifies maintenance.
Goulds Water Technology
PERFORMANCE COVERAGE, 3500 AND 1750 RPM
ALCANCE DE FUNCIONAMIENTO, 3500 Y 1750 RPM
4003002001000 600
40 60 160 180
500 800
1750 RPM
20 80 100 120 140
23SH
27SH
22SH
6SH
25SH
24SH
11SH
10SH
9SH
8SH
5SH
4SH
28SH
7SH
m3/hr
CAPACITY (CAPACIDAD) – U.S. GPM
TO
TA
L D
Y N
A M
IC
H
E A
D (C
A R
G A
D
IN
A M
IC
A
T O
TA
L)
METERS
(METROS)
FEET
(PIES)
4003002001000 600
40 60 160 260 m3/hr
CAPACITY (CAPACIDAD) – U.S. GPM
TO
TA
L D
Y N
A M
IC
H
E A
D (C
A R
G A
D
IN
A M
IC
A
T O
TA
L)
METERS
(METROS)
FEET
(PIES)
500 800
3500 RPM
20 80 100 120 140
1000900 12001100
180 200 220 240
23SH
27SH
22SH
6SH
5SH
8SH
25SH
24SH
11SH
10SH
7SH
9SH
4SH
28SH
LarkinD Line
LarkinD Line
LarkinD Highlight
LarkinD Highlight
Goulds Water Technology
24 SH 1 Q 1 2 A 0 R
Example Product Code, Ejemplo Código del Producto
Mechanical Seals and O-Ring 0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below.
Casing Rotation, Optional R = 3 o’clock B = 6 o’clock L = 9 o’clock NOTE: Rotation when viewed from suction end of pump.
Standard discharge position is 12 o’clock.
Motor Enclosure, Caja del motor
1 = ODP 5 = 3PH, TE PE 9 = 1PH, ODP PE
2 = TEFC 6 = 3PH, XP PE A = 1PH, TE PE
3 = Explosion Proof, Prueba de explosiones 7 = Wash down, Lavado
4 = 3PH, ODP PE 8 = 3PH, WD PE
Motor Voltage, Voltaje del motor 1 = 115/208-230 3 = 230 5 = 208-230/460 7 = 575 2 = 115/230 4 = 230/460 6 = 460 X = Non Std.
HP Rating, Potencia nominal, HP C = ½ F = 1.5 J = 5 M = 15 Q = 30 T = 60 D = .75 G = 2 K = 7.5 N = 20 R = 40 U = 75 E = 1 H = 3 L = 10 P = 25 S = 50 V = 100
Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM 1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/1 2 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3
Material SH = 316L Stainless steel, Acero inoxidable
Pump Size, Tamaño de la Bomba 9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 8 = 2 x 2½ – 8 10 = 1 x 2 – 8 7 = 1½ x 2½ – 8 6 = 2½ x 3 – 6 11 = 1 x 2 – 10 5 = 2 x 2½ – 6 22 = 2½ x 3 – 8 23 = 3 x 4 – 8 24 = 1½ x 2½ – 10 25 = 2 x 2½ – 10 27 = 2½ x 3 – 10 28 = 3 x 4 – 10
SSH S/M-GROUP NUMBERING SYSTEM
SISTEMA DE NUMERACIÓN DEL GRUPO-S/M SSH
Impeller Option Code - For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve.
NOTE: For trimmed impellers, use T for impeller code.
NOTE: Impellers will be trimmed in 1/16” increments only. If you are ordering a trim within 1/16” of the standard impeller, you will receive the standard impeller trim.
* Indicates impellers that can be trimmed
NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with GWT on non-cataloged numbers.
NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con GWT en los números no catalogados.
Frame Options, Opciones de mando Substitute, Description, Substituto Descripción
FRM2
7/8" Imp. Bore, Diámetro interior del impulsor 7/8"
FRM3
1¼" Imp. Bore, Diámetro interior del impulsor 1¼"
Sello Mecánico y Anillo ‘0’ 0 = Estándar aprobado. Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo.
Rotación de la cubierta, opcional R = 3 hora B = 6 hora L = 9 hora NOTA: Rotación cuando está visto del extremo de la succión de la bomba. La posición estándar de la descarga es las 12.
Código del Impulsor Opcional - Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba.
NOTA: Para los impulsores cortados, utilice T para el código del impulsor.
John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21
Seal Code, Código del Sello
Rotary, Rotativo
Stationary, Estacionario
Elastomers, Elastómeros
Metal Parts, Partes Metálicas
Part No., Pieza Número
180-210 Frames, Armazones
250-360 Frames, Armazones
Carbon Sil-Carb
Viton 316 SS, 316 Acero inoxidable
10K27 10K45
2 EPR 10K19 10K20
5 Sil-Carb Sil-Carb Viton 10K64 10K65
Impeller Code, Código del impulsor
Pump Size, Tamaño de la Bomba
9SH
1 x 2-6 Dia.
10SH
1 x 2-8
Dia.
11SH
1 x 2-10
Dia.
4SH
1½ x 2½-6
Dia.
7SH
1½ x 2½-8
Dia.
5SH
2 x 2½-6
Dia.
8SH
2 x 2½-8
Dia.
*6SH
2½ x 3-6
Dia.
*22SH
2½ x 3 – 8
Dia.
*23SH
3 x 4 – 8
Dia.
24SH
1½ x 2½ –
10 Dia.
25SH
2 x 2½
– 10 Dia.
*27SH
2½ x 3
– 10 Dia.
*28SH
3 x 4 – 10
Dia.
A 65⁄8 827⁄64 103⁄32 6¾ 8¼ 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8 B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼ C 511⁄16 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16
D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16
E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16
F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16
G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16
H 43⁄16 611⁄16 67⁄8 J 6½ 6½ K 6 L 5½
NOTA: Los impulsores serán cortados en 1/16 " incrementos solamente. Si usted está pidiendo un ajuste dentro de 1/16 " del impulsor estándar, usted recibirá el ajuste estándar del impulsor.
* Indica los impulsores que pueden ser cortados
LarkinD Text Box Part #: 6SH2N45D2, 256JM
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight larkind
Goulds Water Technology
PERFORMANCE CURVES – 60 HZ, 3500 RPM
CURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
4020 100
250 300
30090
35015010050
A 81/4" DIA.
E 67/8"
B 73/4"
F 63/16"
C 71/2"
D 73/16"
15 HP
20 HP
25 HP
10 HP
EFF%65
656050 10'
13'
16'
21'
Model SSH / 8SH Size (Tamaño) 2 x 21/2 - 8 RPM 3500 Curve (Curva) CN0497R01
METERS
METROS
FEET
PIES
TO
TA
L D
Y N
A M
IC
H
E A
D (C
A R
G A
D
IN
A M
IC
A
T O
TA
L)
(H
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
8’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller, Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 25
B 7¾ 20
C 7½ 20
D 73⁄16 15
E 67⁄8 15
F 63⁄16 10
NOTE: Pump will pass a sphere to ¼" diameter.
NOTA: La bomba pasará una esfera a ¼" diámetro.
Optional Impeller, Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 75⁄16" 25
B 71⁄8 25
C 615⁄16 20
D 611⁄16 20
E 63⁄8 15
F 61⁄16 15
G 55⁄8 10
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
5025 150
400 500
600200100
E 63/8"
A 75/16" DIA.
F 61/16"
B 71/8" C 615/16"
G 55/8"
8'
10'
13'
EFF%60
15'
20'
10 HP
20 HP
25 HP
125100 175
D 611/16"
15 HP
25'
Model SSH / 6SH Size (Tamaño) 21/2 x 3 - 6 RPM 3500 Curve (Curva) CN0500R00
METERS
METROS
FEET
PIES
TO
TA
L D
Y N
A M
IC
H
E A
D (C
A R
G A
D
IN
A M
IC
A
T O
TA
L)
(H
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
LarkinD Line
LarkinD Line larkind Highlight larkind Highlight larkind Highlight
Goulds Water Technology
SSH FRAME MOUNTED – MATERIALS OF CONSTRUCTION
SSH ARMAZÓN MONTADO – MATERIALES DE CONSTRUCCIÓN
SSH CLOSE COUPLED – MATERIALS OF CONSTRUCTION
SSH ACOPLE CERRADO – MATERIALES DE CONSTRUCCIÓN
Item No., Description, Materials, Parte No. Descripción Materiales
100 Casing, Carcasa
101 Impeller, Impulsor
103 Wear ring, Anillo de desgaste 316L SS, 316L acero inox.
184 Seal housing, Alojamiento del sello
126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.
422 Impeller stud, Perno del impulsor Steel, Acero
Impeller key, Carbon steel, Llave del impulsor Acero al carbono
199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.
Casing bolt with nut (casing to adapter), 316L SS, 370 Tornillo de la carcasa con tuerca
316L acero inoxidable (carcasa para adaptador)
Cast iron ASTM A48 CL20, 108 Adapter, Adaptador Hierro fundido ASTM
A48CL20
Hex head cap screw (adapter to motor), Steel SAE 1200 series,371 Tornillo de cabeza hexagonal Acero SAE series 1200 (adaptador para motor)
412A O-ring, Impeller, Anillo en O, impulsor
412F O-ring, shaft sleeve, Anillo en O, camisa del eje Viton
513 O-ring, Anillo 'O'
Drain plug – 3⁄8 BSP, 316L SS, Válvula de drenaje – 3⁄8 BSP 316 acero inoxidable
Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello
Item No., Description, Materials, Parte No. Descripción Materiales
100 Casing, Carcasa
101 Impeller, Impulsor 316L SS, 103 Wear ring, Anillo de desgaste 316L acero inox.
184 Seal housing, Alojamiento del sello
126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.
178 Impeller key, Llave del impulsor Carbon steel, 422 Impeller Stud, Perno del impulsor Acero al carbono
199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.
370 Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS, 408 Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT 316L acero inox.
513 O-ring, Anillo ‘O’ Viton
383 Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello
108 Adapter, Adaptador
228 Bearing frame, Armazón de balineras
134 Bearing cover, Cubierta de balineras
122 Pump shaft, Carbon steel, Eje de la bomba Acero al carbono
168 Ball bearing (inboard), Balineras de bolas (interior)
112 Ball bearing (outboard), Balineras de bolas (exterior)
382 Retaining ring, Anillo de sujeción
Hex head cap screw (adapter to bearing frame), 370B Tornillo de cabeza hexagonal Steel, Acero (adaptador para armazón de balineras)
Hex head cap screw (bearing frame to cover), 370C Tornillo de cabeza hexagonal (armazón de balineras para cubierta)
333A Lip seal, Sello cubierto BUNA-N
193 *Grease fitting, Accesorio de grasa Steel, Acero
123 V-ring deflector, Deflector anillo ‘V’ BUNA-N
* M-Group only
Part No., Pleza Número
10K19 10K20
EPR
Hot Water, 383 Carbon, Silicon 316 SS, Agua Caliente Options, 10K27 10K45 Carbone Carbide, 316 Mild Abrasive, 383 Carburo de Viton
Acero Abrasivo Suave Opciones
10K64 10K65 Sil-Carb.
silicona inoxidable Severe Duty, Deber Severo
Mechanical Seal, Sello Mecánico
John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21
Item, Rotary, Stationary, Elastomers, Parte Rotativo Estacionario Elastómeros
Cast iron ASTM
A48CL20,
Hierro fundido ASTM
A48CL20
Metal Intended Parts, Duty, Partes Servicio Metálicas Propuesto
103 199 422 408 178
100 101 178 108 370
199 422 408 126 371412F
383412A
383100 101 513 370 184 108 228
370B 123 168 112 122382
370C
333A
412F
412A
180-210 250-360 Frames, Frames, Armazones Armazones
LarkinD Line
Line
Goulds Water Technology
(All dimensions in inches and weights in lbs. Do not use for construction purposes.)
(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)
Motor Frame Selections, Selecciones del Armazón del Motor
DISCHARGE
DESCARGA
SUCTION
SUCCIÓN
DC
MAX.G
H-(4) HOLES
H-(4) AGUJEROS
DD X Y Z
143/145 182/184 213/215 254/256 9SH 1 x 2 – 6 5 45⁄8 63⁄8 31⁄8
97⁄8 10½ 11½ —
36.5 10SH 1 x 2 – 8 2 1 55⁄8 5¼ 71⁄8
37⁄8 49.2
11SH 1 x 2 – 10 67⁄8 6¼ 87⁄8 4 10¾ 113⁄8 123⁄8 127⁄8 66 4SH 1½ x 2½ – 6
1½ 5 45⁄8 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 37.7
7SH 1½ x 2½ – 8 2½
55⁄8 5¼ 71⁄8
48.2 5SH 2 x 2½ – 6
5 45⁄8 4 35⁄8 10½
111⁄8
121⁄8 125⁄8 37.9
8SH 2 x 2½ – 8
5¾
77⁄8
54.6 6SH 2½ x 3 – 6 3 2½ 37⁄8 105⁄8 113⁄8 123⁄8 127⁄8 61.8
3⁄8" – 19 BSP
NOTE:
1. Pumps shipped in vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.
2. ALL dimensions in inches.
3. Motor dimensions may vary with motor manufacturer.
4. Not for construction purposes.
NOTA:
1. Las bombas se transportarán en des-carga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.
2. TODAS las dimensiones en pulgadas.
3. Las dimensiones puede que varíen con los fabricantes.
4. No para propósitos de construcción.
Pump, Bomba
DC
Max., DC
Máx.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM
Suct.*, Disch.*, Succ.* Desc.*
150 lb. Flange, Brida de 150 lib. DIM. “L” (Motor Frame Size)
DIM. “L” (Tamaño del Armazón del Motor) Wt.
(lbs.), Pesos
(libras)
* For use with ANSI class 150 mating flanges.
* Para usar con bridas que casan ANSI clase 150.
ODP* TEFC* ODP* TEFC* ODP* TEFC* ODP* TEFC*
143JM – – – – – – 1 1
145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2
182JM 3 3 5 3 2 2-3 3 3
184JM 5 5 7½ 5 3 – 5 5
213JM 7½ – 10 7½ 5 – 7½ 7½
215JM 10 – 15 10-15 – – – –
254TCZ – – 20 15** – – – –
256TCZ – – 25 20 – – – –
1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos
Motor Horsepower, Potencia del Motor
3500 RPM, 3500 RPM 1750 RPM, 1750 RPM
Motor Frame, Armazón del Motor
AB MAX.
X
D
E E A
DD
P
MAX.
F F B
L
Y Z CREF
DRAIN PLUG
PRIME PLUG
SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS S-GROUP
SSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-S
* Premium efficiency where required by Department of Energy regulations.
* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
** Frame size for 208-230/460 Voltage TEPE motor.
** Talla de capítulo para 208-230/460 el motor del voltaje TEPE.
JM Frame, JM
Armazón
A AB
Max. B D E F G C Max.
H
Dia., H
Diám.
P Max., P Máx.
Motor Wt.
(lbs.)
Peso Motor (lib.)
143JM
6½ 5¾ 6 3½ 2¾
1/8 113/16
11/32 73/16
145JM 2½ 54
182JM
85/8 67/8 6½ 4½ 3¾
2¼ 3/16 134/5
13/32
85/8
184JM
2¾
213JM
9½ 82/5 8 5¼ 4¼ 3/16 1514/25 107/25
215JM 3½ 169
254TCZ
11½ 102/5 11½ 6¼ 5
41/8 7/8 201/20
17/32 1313/50
256TCZ 5 298
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Highlight
LarkinD Text Box
254JM
Goulds Water Technology
SPECIFICATIONS
ESPECIFICACIONES
Capacities to:
1100 GPM (250 m3/hr) at
3500 RPM 775 GPM
(177 m3/hr) at 1750 RPM
Heads to:
525 feet THD (158 m) at
3500 RPM
130 feet THD (40 m) at
1750 RPM
Maximum working pres-sures to: 230 PSI (15 bars)
Maximum temperatures to: 250°F (121°C)
All wetted components of AISI: Type 316L stainless steel material.
Rotation: Clockwise when viewed from motor end.
Enclosed impeller and replaceable wear ring:
for high efficiency and maxi-mum wear life.
Motor (close coupled):
NEMA standard JM shaft open drip-proof*, totally en-closed* and explosion-proof enclosures*, 60 Hz, 1750 or
3500 RPM.
Single phase ODP* (115/230
V) 1750 RPM, 1 – 5 HP.
Three phase ODP*. TEFC*/ Exp. proof* (208 – 230/460 V).
3500 RPM, 2 – 100 HP
1750 RPM, 1 – 25 HP
NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.
Motor (frame mounted):
NEMA standard T-frame open drip-proof*, totally enclosed* and explosion-proof* (three phase only) enclosures 60 Hz, 1750 or
3500 RPM.
Single phase (115/230 V)
1750 RPM, 1 – 5 HP
Three phase (208 – 230/ 460 V)
3500 RPM, 3 – 125 HP
1750 RPM, 1 – 25 HP
NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.
Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.
* Premium efficiency where required by Department of Energy regulations.
Capacidades:
1100 GPM (105 m 3/hr) a
3500 RPM 775 GPM (177
m3/hr) a 1750 RPM
Cargas:
525 pies THD (158 m) a 3500 RPM 130 pies THD (40
m) a 1750 RPM
Presión de trabajo máxi-ma:
230 PSI (15 baras)
Temperatura máxima:
250°F (121°C)
Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L.
Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.
Impulsor encerrado y anillo de desgaste reem-plazable: para alta eficien-cia y máxima durabilidad.
Motor (acople cerrado):
Eje a prueba de goteo* JM estándar NEMA, totalmente encerrado* y recintos a prueba de explosión*, 60 Hz, 1750 ó 3500 RPM.
Unifásicos ODP (115/230 V)
1750 RPM, 1 – 5 HP
Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V).
3500 RPM, 2 – 100 HP
1750 RPM, 1 – 25 HP
NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.
Motor (armazón mon-tado): Armazón abierto T a prueba de goteo* estándar NEMA, totalmente encer-rado* y recintos a prueba de explosión* (trifásicos solamente) 60 Hz, 1750 ó
3500 RPM.
Unifásicos (115/230 V)
1750 RPM, 1 – 5 HP.
Trifásicos (208 – 230/460 V)
3500 RPM, 3 – 125 HP
1750 RPM, 1 – 25 HP
NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.
Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las espe-cificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.
* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
Product Information Packet
EJMM4106T
20HP,3520RPM,3PH,60HZ,256JM,0936M,TEFC,F
Copyright © All product information within this document is subject to Baldor Electric Company copyright © protection, unless otherwise noted.
LarkinD Text Box SPECIAL MOTOR with condensation heater and shaft grounding ring
LarkinD Text Box Note: This submittal may require revision. Supplier cannot provide motor data sheet until after purchase order.
LarkinD
SPECIAL JUNCTION BOXES: Oversized main junction box and additional junction box for condensation heater.
Product Information Packet: EJMM4106T - 20HP,3520RPM,3PH,60HZ,256JM,0936M,TEFC,F
Part Detail
Revision: T Status: PRD/A Change #: Proprietary: No
Type: AC Prod. Type: 0936M Elec. Spec: 09WGZ601 CD Diagram: CD0005
Enclosure: TEFC Mfg Plant: Mech. Spec: 09P14 Layout: 09LYP014
Frame: 256JM Mounting: F1 Poles: 02 Created Date: 05-06-2010
Base: RG Rotation: R Insulation: F Eff. Date: 03-15-2017
Leads: 9#12 Replaced By:
Literature: Elec. Diagram:
Nameplate NP3441L
CAT.NO. EJMM4106T
SPEC. 09P014Z601G1
HP 20
VOLTS 230/460
AMP 46/23
RPM 3520
FRAME 256JM HZ 60 PH 3
SER.F. 1.15 CODE H DES A CL F
NEMA-NOM-EFF 91 PF 89
RATING 40C AMB-CONT
CC 010A USABLE AT 208V 50
DE 6309 ODE 6208
ENCL TEFC SN
VPWM INVERTER READY
CT6-60H(10:1)VT3-60H(20:1
Parts List
Part Number Description Quantity
SA194418 SA 09P014Z601G1 1.000 EA
RA182005 RA 09P014Z601G1 1.000 EA
37FN3002C02 EXFN, PLASTIC, 6.00 OD, 1.500 ID 1.000 EA
HW1002A63 WASHER, 5/8 HI-COLLAR SPRLCKWASHER 1.000 EA
09CB3002 CB W/1.38 LEAD HOLE FOR 37, 39, 307 & 30 1.000 EA
09GS1000 GASKET-CONDUIT BOX, 1/16 THICK LEXIDE 1.000 EA
10XN2520K12 1/4-20 X.75 GRD 5 2.000 EA
HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 2.000 EA
09EP1300A52 ENDPLATE, MACH 1.000 EA
HW4600B44 V-RING SLINGER 1.500 X 1.810 X .28 VITON 1.000 EA
WD1000B17 T&B CX35TN TERMINAL 1.000 EA
51XW1032A06 10-32 X .38, TAPTITE II, HEX WSHR SLTD S 1.000 EA
09FE1100A14 FREP ASSEMBLY, 09EP1100A14 1.000 EA
XY3816A12 3/8-16 FINISHED NUT 4.000 EA
HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA
HW5100A08 W3118-035 WVY WSHR (WB) 1.000 EA
10XN2520K28 1/4-20 X 1.75" HX HD SCRWGRADE 5, ZINC P 2.000 EA
HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 2.000 EA
10XN2520K36 1/4-20 X 2.25" HX HD SCRWGRADE 5, ZINC P 4.000 EA
HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 4.000 EA
HA3113A02 THRUBOLT 3/8-16 X 16.750 4.000 EA
HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA
09FH4000SP FAN COVER, STAMPED 1.000 EA
HA2081A05 SPACER TUBE, 309 FAN HSG, 2.00 LONG 4.000 EA
Parts List (continued)
Part Number Description Quantity
HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 4.000 EA
XY3816A12 3/8-16 FINISHED NUT 4.000 EA
09CB3501 CONDUIT BOX LID FOR 09CB3001 & 09CB3002 1.000 EA
09GS1013 09 GS FOR 09CB3501 LID - LEXIDE 1.000 EA
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA
HW2501E22 KEY, 1/4 SQ X 2.500 1.000 EA
LB1115N LABEL,LIFTING DEVICE (ON ROLLS) 1.000 EA
MN416A01 TAG-INSTAL-MAINT no wire (1000/bx) 11/14 1.000 EA
HW4500A05 1669B ALEM/UNIV860 GR FTG X 1.000 EA
HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA
HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA
HA4051A00 PLASTIC CAP FOR GREASE FITTING 1.000 EA
MJ1000A02 GREASE, POLYREX EM EXXON (USe 4824-15A) 0.080 LB
HW4500A03 GREASE FITTING, .125 NPT 1610(ALEMITE) 8 1.000 EA
HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA
HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA
HA4051A00 PLASTIC CAP FOR GREASE FITTING 1.000 EA
HW2500A25 WOODRUFF KEY USA #1008 #BLOW CARBON STEE 1.000 EA
51XB1214A20 12-14X1.25 HXWSSLD SERTYB 1.000 EA
MG1000Y03 MUNSELL 2.53Y 6.70/ 4.60, GLOSS 20, 0.050 GA
85XU0407S04 4X1/4 U DRIVE PIN STAINLESS 2.000 EA
LC0005E02 SPL CONN.DIA./WARN.LABEL(LC0005/LB1119) 1.000 EA
NP3441L ALUM SUPER-E VPWM INVERTER READY UL 1.000 EA
40PA1005 PACKAGING GROUP, 09 STD 1.000 EA
AC Induction Motor Performance Data Record # 31396 - Typical performance - not guaranteed values
Winding: 09WGZ601-R001 Type: 0936M Enclosure: TEFC
Nameplate Data 460 V, 60 Hz:
High Voltage Connection
Rated Output (HP) 20 Full Load Torque 29.6 LB-FT
Volts 230/460 Start Configuration direct on line
Full Load Amps 46/23 Breakdown Torque 111 LB-FT
R.P.M. 3520 Pull-up Torque 39.1 LB-FT
Hz 60 Phase 3 Locked-rotor Torque 49.6 LB-FT
NEMA Design Code B KVA Code H Starting Current 161 A
Service Factor (S.F.) 1.15 No-load Current 7.17 A
NEMA Nom. Eff. 91 Power Factor 89 Lineline Res. @ 25ºC 0.47592 Ω
Rating - Duty 40C AMB-CONT Temp. Rise @ Rated Load 76°C
S.F. Amps Temp. Rise @ S.F. Load 95°C
Locked-rotor Power Factor 29
Rotor inertia 0.92 LB-FT2
Load Characteristics 460 V, 60 Hz, 20 HP
% of Rated Load 25 50 75 100 125 150 S.F.
Power Factor 58 78 86 89 90 90 90
Efficiency 88.9 92.2 92.4 91.7 90.7 89.2 91.1
Speed 3579.6 3561.5 3541.3 3519.5 3495.4 3467.8 3505
Line amperes 9 13 17.7 22.9 28.6 35 26.3
Performance Graph at 460V, 60Hz, 20.0HP Typical performance - Not guaranteed values
LarkinD Line
LarkinD Text Box main junction box, size and location TBD
LarkinD Text Box additional junction box, size and location TBD
LarkinD Rectangle
Rectangle
GRUNDFOS DATA BOOKLET
CR, CRI, CRN
Vertical multistage centrifugal pumps 60 Hz
LarkinD Text Box Document: NYCS000015286R01
LarkinD Text Box
WH172296
Part #: CRN64 1-1-A-G-G-E HQQE Special motor: 10HP, SEVERE DUTY, PREMIUM EFF, 230/460V, 3PH, 3500 RPM with condensation heater Mechanical seal: Silicon Carbide / Silicon Carbide with EPDM elastomers
P ro d u c t in tr o d u c ti o n
CR, CRI, CRN 1
1. Product introduction
This data booklet deals with Grundfos CR, CRI and CRN pumps.
Fig. 1 CR, CRI and CRN pumps
Features and benefits Grundfos CR, CRI, CRN pumps are vertical multistage centrifugal pumps. The in-line design enables the pump to be installed in a horizontal one-pipe system where the suction and discharge ports are in the same horizontal plane and have the same pipe dimensions.
This design provides a more compact pump design and pipework.
Grundfos CR pumps come with various pump sizes and various numbers of stages to provide the flow and the pressure required.
CR pumps are suitable for a variety of applications from pumping of potable water to pumping of chemicals. The pumps are therefore used in a wide variety of pumping systems where the performance and material of the pump meet specific demands.
The CR pumps consist of two main components: the motor and the pump unit. The motor on a CR pump is a heavy-duty Grundfos specified motor.
The pump unit consists of optimized hydraulics, various types of connections, an outer sleeve, a top and various other parts.
CR pumps are available in various material versions according to the pumped liquid.
Pump The CR pump is a non-self-priming, vertical multistage centrifugal pump. The pumps are available with a Grundfos standard motor.
The pump consists of a base and a pump head. The chamber stack and the outer sleeve are secured between the pump head and the base by means of staybolts. The base has suction and discharge ports on the same level (in-line).
All pumps are equipped with a maintenance-free mechanical shaft seal of the cartridge type.
Fig. 2 CR pump
CR pump with ANSI/NSF 61 listing is available. See UL file MH26400 or contact Grundfos.
Motor
Grundfos standard motors - ML and Baldor® motors
CR, CRI and CRN pumps are fitted with a Grundfos specified motor. The motors are all heavy-duty 2-pole, NEMA C-face motors.
T M
G R
G
R
Motor
Coupling
Pump head
Outer sleeve
Staybolts
Base plate
Base
Impellers
Shaft seal (Cartridge type)
P ro d u c t in tro d u c tio n
CR, CRI, CRN1
Electrical data
* 1-10 Hp ML motors are premium efficiency as standard.
Optional motors
The Grundfos standard range of motors covers a wide variety of application demands. However, for special applications or operating conditions, custom-built motor solutions can be provided.
For special applications or operating conditions, Grundfos offers custom-built motors such as:
• explosion proof motors
• motors with anti-condensation heating unit
• low-noise motors
• premium efficiency motors
• motors with thermal protection.
Motor protection
Single-phase Grundfos specified motors up to 7.5 Hp have a built-in thermal overload switch.
Three-phase motors must be connected to a motor starter in accordance with local regulations.
Terminal box positions As standard the terminal box is mounted on the suction side of the pump.
Fig. 3 Terminal box positions
Viscosity The pumping of liquids with densities or kinematic viscosities higher than those of water will cause a considerable pressure drop, a drop in the hydraulic performance and a rise in the power consumption.
In such situations, the pump should be fitted with a larger motor. If in doubt, contact Grundfos.
Ambient temperature and altitude If the ambient temperature exceeds the maximum temperature limits of the pump or the pump is installed at an altitude exceeding the altitude values in the chart below, the motor must not be fully loaded due to the risk of overheating.
Overheating may result from excessive ambient temperatures or the low density and consequently low cooling effect of the air at high altitudes. In such cases, it may be necessary to use a motor with a higher rated output (P2).
Fig. 4 Relationship between motor output (P2) and ambient temperature/altitude
Legend
Example: From fig. 4 it appears that P2 must be reduced to 88 % when a pump with a NEMA premium-efficiency ML motor is installed 15,584 ft (4750 m) above sea level. At an ambient temperature of 167 °F (75 °C), P2 of a standard-efficiency motor must be reduced to 74 % of rated output.
In cases where both the maximum temperature and the maximum altitude are exceeded, the derating factors must be multiplied. Example: 0.89 x 0.89 = 0.79.
Mounting designation NEMA
Insulation class F & B
Efficiency class* Energy efficient Premium efficiency - on request for 15 Hp and above
Enclosure class TEFC - Totally Enclosed Fan Cooled (Grundfos standard) ODP - Open Drip Proof - on request
60 Hz standard voltages 1 x 115/208-230 V 3 x 208-230/460 V 3 x 575 V
Approvals
The motors are rated for:
Baldor ML
T M
RU RUC US
Stellung 6 Stellung 9 Stellung 12 Stellung 3Position 6 Standard
Position 9 Position 12 Position 3
T M
Pos. Description
1 NEMA energy efficient motors
2 NEMA premium-efficiency motors
60 80 100 120 140 160 180 T [°F]
P2
3280 7382 11483 15584 ft
Id e n ti fi c a ti o n
CR, CRI, CRN 5
5. Identification
Type key
CR, CRI, CRN
Codes
1) If a pump incorporates more than two pump versions, the code for the pump version is X.
X also indicates special pump versions not listed above.
Example CR 32 (s) -4 -2 -A -G -G -E - HQQE
Type range:
CR, CRI, CRN
Nominal flow rate [m3/h]
All impellers with reduced diameter (applies only to CR, CRI, CRN 1s)
Number of impellers
Number of reduced diameter impellers (CR, CRN 32, 45, 64, 90, 120, and 150)
Code for pump version
Code for pipe connection
Code for materials
Code for rubber parts
Code for shaft seal
Example A -G -A -E -H QQ E
Pump version1)
A Basic version
B Oversize motor
E Certificate/approval
F CR pump for high temperatures (air-cooled top assembly)
H Horizontal version
HS
High-pressure pump with high speed MLE motor
I Different pressure rating
J Pump with different max speed
K Pump with low NPSH
M Magnetic drive
N Fitted with sensor
P Undersize motor
R Horizontal version with bearing bracket
SF High pressure pump
T Over size motor (two flange sizes bigger)
X Special version
Pipe connection
A Oval flange Rp thread
B Oval flange NPT thread
CA FlexiClamp (CRI, CRN 1, 3, 5, 10, 15, 20)
CX Triclamp (CRI, CRN 1, 3, 5, 10, 15, 20)
F DIN flange
G ANSI flange
J JIS flange
N Changed diameter of ports
P PJE coupling
X Special version
Materials
A Basic version
D Carbon-graphite filled PTFE (bearings)
G Wetted parts AISI 316
GI All parts stainless steel, wetted parts AISI 316
I Wetted parts AISI 304
II All parts stainless steel, wetted parts AISI 304
K Bronze (bearings)
S SiC bearings + PTFE neck rings
X Special version
Code for rubber parts
E EPDM
F FXM
K FFKM
V FKM
Shaft seal
A O-ring seal with fixed driver
B Rubber bellows seal
E Cartridge seal with O-ring
H Balanced cartridge seal with O-ring
K Metal bellows cartridge seal
O Double seal, back-to-back
P Double seal, tandem
X Special version
B Carbon, synthetic resin-impregnated
H Cemented tungsten carbide, embedded (hybrid)
Q Silicon carbide
U Cemented tungsten carbide
X Other ceramics
E EPDM
F FXM
K FFKM
V FKM
Example A -G -A -E -H QQ E larkind Text Box
WH172296
CRN 64-1-1-AGGE-HQQE
larkind Rectangle larkind Text Box
CRN 64-1-1
larkind Rectangle larkind Rectangle larkind Rectangle larkind Rectangle larkind Text Box
AGGE HQQE
larkind Text Box
AGGE HQQE
larkind Rectangle larkind Rectangle larkind Text Box
AGGE HQQE
larkind
QQ Silicon carbide / Silicon carbide
C o n s tr u c ti o n
CR, CRI, CRN 6
CR 32, 45, 64 and 90
Sectional drawing
Materials: CR
CRN 32, 45, 64 and 90
Sectional drawing
Materials: CRN
1) Stainless steel available on request.
T M
T M
Pos. Designation Materials AISI/ASTM
1 Pump head Cast iron
EN-GJS-500-7
ASTM 80-55-06
2 Motor stool Cast iron
EN-GJL-200
ASTM 25B
3 Shaft Stainless steel AISI 431
4 Impeller Stainless steel AISI 304
5 Chamber Stainless steel AISI 304
6 Sleeve Stainless steel AISI 304
7 O-ring for sleeve EPDM or FKM
8 Base Cast iron
EN-GJS-500-7
ASTM 80-55-06
9 Neck ring Carbon-graphite-filled
PTFE
10 Shaft seal
11 Bearing ring SiC/SiC
12 Flange ring Ductile iron A 65-45-12
Rubber parts EPDM or FKM
T M
T M
Pos. Designation Materials AISI/ASTM
1 Pump head Stainless steel CF 8M equal to
AISI 316
2 Motor stool Cast iron
EN-GJL-2001) ASTM 25B
3 Shaft Stainless steel
4 Impeller Stainless steel AISI 316
5 Chamber Stainless steel AISI 316
6 Sleeve Stainless steel AISI 316
7 O-ring for sleeve EPDM or FKM
8 Base Stainless steel CF 8M equal to
AISI 316
9 Neck ring Carbon-graphite-filled
PTFE
10 Shaft seal
11 Bearing ring SiC/SiC
12 Base plate Cast iron
EN-GJS-500-71) ASTM 88-55-06
Flange ring Ductile iron1) A 65-45-12
Rubber parts EPDM or FKM larkind Line
O p e ra tin g c o n d itio n s
CR, CRI, CRN7
Working and inlet pressure
Max. working pressure and temperature range
Oval flange
T M
Max.
working pressure
[psi]
Liquid temp.
range [°F]
CR, CRI, CRN 1s 232 -4 to +248
CR, CRI, CRN 1 232 -4 to +248
CR, CRI, CRN 3 232 -4 to +248
CR, CRI, CRN 5 232 -4 to +248
CR 10-1 → CR 10-6 145 -4 to +248
CRI, CRN 10-1 → CRI, CRN 10-10 232 -4 to +248
CR 15-1 → CR 15-5 145 -4 to +248
CRI, CRN 15-1 → CRI, CRN 15-8 232 -4 to +248
CR 20-1 → CR 20-5 145 -4 to +248
CRI, CRN 20-1 → CRI, CRN 20-7 232 -4 to +248
ANSI, Clamp, PJE
T M
Max.
working pressure
[psi]
Liquid temp.
range [°F]
CR, CRI, CRN 1s 362 -4 to +248
CR, CRI, CRN 1 362 -4 to +248
CR, CRI, CRN 3 362 -4 to +248
CR, CRI, CRN 5 362 -4 to +248
CR, CRI 10-1 → 10-10 232 -4 to +248
CR, CRI 10-12 → 10-17 362 -4 to +248
CRN 10 (all stages) 362 -4 to +248
CR, CRI 15-1 → 15-8 232 -4 to +248
CR, CRI 15-9 → 15-12 362 -4 to +248
CRN 15 (all stages) 362 -4 to +248
CR, CRI 20-1 → 20-7 232 -4 to +248
CR, CRI 20-8 → 20-10 362 -4 to +248
CRN 20 (all stages) 362 -4 to +248
CR, CRN 32-1-1 → 2-5 232 -22 to +248
CR, CRN 32-6-2 → 32-11-2 435 -22 to +248
CR, CRN 45-1-1 → 45-4-2 232 -22 to +248
CR, CRN 45-4-1 → 45-8-1 435 -22 to +248
CR, CRN 64-1-1 → 64-3 232 -22 to +248
CR, CRN 64-4-2 → 64-5-2 435 -22 to +248
CR, CRN 90-1-1 → 90-3 232 -22 to +248
CR, CRN 90-4-2 → 90-4-1 435 -22 to +248
CR, CRN 120-1-1 → 120-5-1 435 -22 to +248
CR, CRN 150-1-1 → 150-4-1 435 -22 to +248
LarkinD Rectangle
LarkinD Line e ra ti n g c o n d it io n s
CR, CRI, CRN 7
Operating range of the shaft seal The operating range of the shaft seal depends on operating pressure, pump type, type of shaft seal and liquid temperature. The following curves apply to clean water and water with anti-freeze liquids. For selecting the right shaft seal, see Pumped liquids on page 13.
CR 1s - CR 20
Fig. 5 Operating range of standard shaft seals for CR 1s - CR 20
CR 32 - CR 150 (3.0-60 Hp)
Fig. 6 Operating range of standard shaft seals for CR 32 - CR 150 (3.0-60 Hp)
CR 120 - CR 150 (75-100 Hp)
Fig. 7 Operating range of standard shaft seals for CR 120 - CR 150 (75-100 Hp)
Note: TC= tungsten carbide
See section Lists of variants - on request on page 77, in case of extreme temperatures:
• low temperatures down to -40 °F or
• high temperatures up to +356 °F.
T M
T M
T M
-40-80 0 40 80 120 160 200 240 t [°F ]
[psi] p
-40 -20-60 0 20 40 60 80 100 t [°C ]
[bar] p
HQQE
HQQV
HQQE
H Q
Q E
-40 0 40 80 120 160 200 240 t [°F ]
[ps i] p
-40 -20 0 20 40 60 80 100 t [°C ]
[bar] p
HQQE
HUBE / HUBV HUBE
H Q
Q E
HQQE / HQQV
HQQE
HBQEH
Q
Q E
H Q
Q E
H Q
Q
V HQQE/V
HBQE/V
-40-80 0 40 80 120 160 200 240 t [°F]
-40 -20-60 0 20 40 60 80 100 t [°C]
[psi] p
[bar] p
Shaft seal
Description Max. temp. range
[°F]
HQQE
O-ring (cartridge) (balanced seal), SiC/SiC, EPDM
-40 °F to +248 °F
HBQE
O-ring (cartridge) (balanced seal), Carbon/SiC, EPDM
+32 °F to +248 °F
HBQV
O-ring (cartridge) (balanced seal), Carbon/SiC, FKM
+32 °F to +194 °F
HQQV
O-ring (cartridge) (balanced seal), SiC/SiC, FKM
-4 °F to +194 °F
HUBE
O-ring (cartridge) (balanced seal), TC/carbon, EPDM
+32 °F to +248 °F
HUBV
O-ring (cartridge) (balanced seal), TC/carbon, FKM
+32 °F to +194 °F
LarkinD Line
LarkinD Line
LarkinD Line
LarkinD Line e ra tin g c o n d itio n s
CR, CRI, CRN7
Maximum inlet pressure The following table shows the maximum permissible inlet pressure. However, the current inlet pressure + the pressure against a closed valve must always be lower than the maximum permissible operating pressure.
If the maximum permissible operating pressure is exceeded, the bearing in the motor may be damaged and the life of the shaft seal reduced.
Example of operating and inlet pressures
The values for operating and inlet pressures shown in the tables must not be considered individually but must always be compared, see the following examples:
Example 1:
The following pump type has been selected: CR 3-10 A-A-A
Max. operating pressure: 232 psi
Max. inlet pressure: 145 psi
Discharge pressure against a closed valve: 139.2 psi, see page 43.
This pump is not allowed to start at an inlet pressure of 145 psi, but at an inlet pressure of 232.0 - 139.2 =
92.8 psi.
Example 2:
The following pump has been selected: CR 10-2 A-GJ- A
Max. operating pressure: 232 psi
Max. inlet pressure: 116 psi
Discharge pressure against a closed valve: 42 psi (97 ft), see page 49.
This pump is allowed to start at an inlet pressure of 116 psi, as the discharge pressure is only 42 psi, which results in an operating pressure of 116 + 42 = 158 psi.
On the contrary, the max. operating pressure of this pump is limited to 158 psi, as a higher operating pressure will require an inlet pressure of more than 116 psi.
In case the inlet or operating pressure exceeds the pressure permitted, see section Lists of variants - on request on page 77.
Pump type Stages Max.
[psi (bar)]60 Hz 50 Hz
CR, CRI, CRN 1s 2-27 2-36 145 (10)
CR, CRI, CRN 1 2-25 2-36 145 (10)
27 217 (15)
CR, CRI, CRN 3 2-17 2-29 145 (10)
19-25 31-36 217 (15)
CR, CRI, CRN 5 2-9 3-16 145 (10)
10-24 18-36 217 (15)
CR, CRI, CRN 10 1-5 1-6 116 (8)
6-17 7-22 145 (10)
CR, CRI, CRN 15 1-2 1-3 116 (8)
3-12 4-17 145 (10)
CR, CRI, CRN 20 1 1-3 116 (8)
2-10 4-17 145 (10)
CR, CRN 32 1-1 - 2 1-1 - 4 58 (4)
3-2 - 6 5-2 - 10 145 (10)
7-2 - 11-2 11-14 217 (15)
CR, CRN 45 1-1 - 1 1-1 - 2 58 (4)
2-2 - 3 3-2 - 5 145 (10)
4-2 - 8-1 6-2 - 13-2 217 (15)
CR, CRN 64 1-1 1-1 - 2-2 58 (4)
1 - 2-1 2-1 - 4-2 145 (10)
2 - 5-2 4-1 - 8-1 217 (15)
CR, CRN 90 1-1 - 1 58 (4)
1-1 - 1 2-2 - 3-2 145 (10)
2-2 - 4-1 3-6 217 (15)
CR, CRN 120 1-1 - 1 1 - 2-1 145 (10)
2-2 - 3 2 - 5-1 217 (15)
4-1 - 5-1 6-1 - 7 290 (20)
CR, CRN 150 1-1 1-1 - 1 145 (10)
1-2 2-1 - 4-1 217 (15)
3-2 - 4-1 5-2 - 6 290 (20)
LarkinD Rectangle
Company name:
Created by:
Phone:
Date: 4/24/2017
Printed from Grundfos Product Center [2017.01.060]
97744287 CRN 64-1-1 60 Hz H [ft]
Q [US gpm]0 50 100 150 200 250 300 350 400 eta
CRN 64-1-1, 60Hz
Pumped liquid = Water Liquid temperature during operation = 68 °F Density = 62.29 lb/ft³
P
[HP]
NPSH
[ft]
P1
P2
1/1
Quotation 1002596524 PALL ADVANCED SEPARATIONS SYSTEMS / RE: RE: Request call - Larkin at Pall
Position: 20 97744287 CRN64-1-1 A-G-G-E-HQQE 3x230/460 60 HZ Curve larkind Text Box Metric larkind Text Box
T c h n ic a l d a ta
10CR, CRI, CRN Technical data
CRN 64
1) Weights are based on pump with TEFC motor (see price list for individual weights).
All dimensions in inches unless otherwise noted.
T M
Pump type P2
[Hp] Ph.
ANSI dimensions [inch (mm)]
Ship. wt.1)
[lbs (kg)]B1
TEFC ODP
D1 D2 B1+B2 D1 D2 B1+B2
CRN 64-1-1 10
1 22.09 (562) 10.23 (260) 10.30 (262) 38.16 (970) - - - 269 (123)
3 22.09 (562) 10.24 (261) 6.26 (160) 36.82 (936) - - - 253 (115)
CRN 64-1 15 3 26.42 (672) 12.36 (314) 8.00 (204) 44.96 (1142) 10.62 (270) 7.33 (187) 42.73 (1086) 349 (159)
CRN 64-2-2 20 3 29.69 (755) 12.36 (314) 8.00 (204) 48.23 (1226) 11.50 (293) 8.92 (227) 49.38 (1255) 364 (166)
CRN 64-2-1 20 3 29.69 (755) 12.36 (314) 8.00 (204) 48.23 (1226) 11.50 (293) 8.92 (227) 49.38 (1255) 364 (166)
CRN 64-2 25 3 29.69 (755) 12.36 (314) 8.00 (204) 52.08 (1323) 11.50 (293) 8.94 (228) 50.50 (1283) 357 (162)
CRN 64-3-2 30 3 32.91 (836) 12.36 (314) 8.00 (204) 55.30 (1405) 11.50 (293) 8.94 (228) 54.72 (1390) 432 (196)
CRN 64-3-1 40 3 32.91 (836) 15.32 (390) 13.11 (333) 56.10 (1425) 13.25 (337) 12.21 (311) 56.16 (1427) 625 (284)
CRN 64-3 40 3 32.91 (836) 15.32 (390) 13.11 (333) 56.10 (1425) 13.25 (337) 12.21 (311) 56.16 (1427) 625 (284)
CRN 64-4-2 40 3 36.18 (919) 15.32 (390) 13.11 (333) 59.37 (1508) 13.25 (337) 12.21 (311) 59.43 (1510) 625 (284)
CRN 64-4-1 50 3 36.18 (919) 16.88 (429) 14.12 (359) 63.99 (1626) 13.25 (337) 12.21 (311) 58.93 (1497) 678 (308)
CRN 64-4 50 3 36.18 (919) 16.88 (429) 14.12 (359) 63.99 (1626) 13.25 (337) 12.21 (311) 58.93 (1497) 678 (308)
CRN 64-5-2 60 3 39.41 (1002) 19.00 (483) 14.90 (379) 70.20 (1784) 15.12 (385) 13.19 (336) 65.54 (1665) 868 (394) larkind Rectangle larkind Line larkind Line larkind Rectangle larkind Rectangle larkind Rectangle larkind Rectangle larkind Line
Product Information Packet
Grundfos Pumps Mfg. Corp.
07H409W279G1
10HP,3525RPM,3PH,60HZ,213TC,0738M,TEFC,F
Copyright © All product information within this document is subject to Baldor Electric Company copyright © protection, unless otherwise noted.
LarkinD Text Box SPECIAL MOTOR: Severe Duty with condensation heater.
LarkinD Text Box Note: This submittal may require revision. Supplier cannot provide motor data sheet until after purchase order.
LarkinD
SPECIAL JUNCTION BOXES: Oversized main junction box and additional junction box for condensation heater.
Product Information Packet: 07H409W279G1 - 10HP,3525RPM,3PH,60HZ,213TC,0738M,TEFC,F
Part Detail
Revision: AK Status: PRD/A Change #: Proprietary: Yes
Type: AC Prod. Type: 0738M Elec. Spec: 07WGW279 CD Diagram: CD0005
Enclosure: TEFC Mfg Plant: Mech. Spec: 07H409 Layout: 07LYH409
Frame: 213TC Mounting: F1 Poles: 02 Created Date:
Base: N Rotation: R Insulation: F Eff. Date: 03-02-2016
Leads: 9#16 Replaced By:
Literature: Elec. Diagram:
Nameplate NP1259L
CAT.NO. 85600H22
SPEC. 07H409W279G1
HP 10
VOLTS 208-230/460
AMP 24.8-23.8/11.9
RPM 3525
FRAME 213TC HZ 60 PH 3
SER.F. 1.15 CODE K DES B CL F
NEMA-NOM-EFF 91 PF 93
RATING 40C AMB-CONT
CC 010A USABLE AT 208V
DE 6309 ODE 6206
ENCL TEFC SN
SFA 28.2-26.6/13.3
Parts List
Part Number Description Quantity
SA021473 SA 07H409W279G1 1.000 EA
RA017525 RA 07H409W279G1 1.000 EA
36FN3000C02 EXFN, PLASTIC, 5.25 OD, 1.175 ID 1.000 EA
HA6283A01 SP'L EYE BOLT BRACKET FOR 306 & 307 MTRS 2.000 EA
10XN3816A12 3/8-16 X 3/4 HEX HD CAP SCREW 2.000 EA
HW1001A38 LOCKWASHER 3/8, ZINC PLT .688 OD, .382 I 2.000 EA
09CB3000SP CONDUIT BOX CAST 1.000 EA
09GS1000SP GASKET-CONDUIT BOX, 1/16 THICK LEXIDE 1.000 EA
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA
WD1000B17 T&B CX35TN TERMINAL 1.000 EA
11XW1032G06 10-32 X .38, TAPTITE II, HEX WSHR SLTD U 1.000 EA
37FE1100A89 FR ENDPLATE ASSEMBLY FOR ROUTING 1.000 EA
HW4500A01 1641B(ALEMITE)400 UNIV, GREASE FITT 1.000 EA
HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA
HW4500A17 317400 ALEMITE GREASE RELIEF 1.000 EA
HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA
HA4054 SHORT T-DRAIN FITTING, .125" N.P.T. 1.000 EA
10XN2520A36 1/4-20X 2 1/4 HEX HD X 4.000 EA
HW5100A06 W2420-025 WVY WSHR (WB) 1.000 EA
37PE1302A22 PUEP ASSEMBLY FOR ROUTING 1.000 EA
HW4500A01 1641B(ALEMITE)400 UNIV, GREASE FITT 1.000 EA
HW1001A25 LOCKWASHER 1/4, ZINC PLT .493 OD, .255 I 4.000 EA
HA3104A32 THRUBOLT- 5/16-18 X12.750 4.000 EA
XY3118A12 5/16-18 HEX NUT DIRECTIONAL SERRATION 4.000 EA
Parts List (continued)
Part Number Description Quantity
51XB1214A20 12-14X1.25 HXWSSLD SERTYB 1.000 EA
07FH4007SP IFC FANCOVER, PRIMED 1.000 EA
51XW1032A06 10-32 X .38, TAPTITE II, HEX WSHR SLTD S 3.000 EA
09CB3500SP CONDUIT BOX LID, CAST 1.000 EA
09GS1001 GASKET-CONDUIT BOX LID, 1/16 THICK LEXID 1.000 EA
51XW2520A12 .25-20 X .75, TAPTITE II, HEX WSHR SLTD 2.000 EA
HW2501F21 KEY, 5/16 SQ X 2.375 1.000 EA
HA7000A02 KEY RETAINER RING, 1 1/8 DIA, 1 3/8 DIA 1.000 EA
85XU0407S04 4X1/4 U DRIVE PIN STAINLESS 2.000 EA
LB1182 WARNING LABEL FOR MOTORS WITH EYENUTS 1.000 EA
MJ1000A02 GREASE, POLYREX EM EXXON (USe 4824-15A) 0.050 LB
MG1000L07 RAL9005, SAFETY/JET BLACK, GLOSS 15 +/-5 0.036 GA
LB1119N WARNING LABEL 1.000 EA
LC0005 CONN.DIA.,TY M,9-LD,DUAL VOLT,REVERSING 1.000 EA
NP1259L ALUM SUPER-E UL CSA-EEV CC NEMA PREMIUM 1.000 EA
07PA1011 PKG GRP, 07 CAST IRON PK1181 1.000 EA
07PA1095 PKG GRP, VER 07 CAST IRON 1.000 EA
PK5535A01 MODIFIED STD EURO PALLET 47-1/4 X 31-1/2 0.500 EA
MN416A01 TAG-INSTAL-MAINT no wire (1000/bx) 11/14 1.000 EA
LB1417 LABEL CARTON 6X4 PERFORATED BLANK ROLLS 1.000 EA
AC Induction Motor Performance Data Record # 46228 - Typical performance - not guaranteed values
Winding: 07WGW279-R018 Type: 0738M Enclosure: TEFC
Nameplate Data 460 V, 60 Hz:
Single Voltage Motor
Rated Output (HP) 10 Full Load Torque 15 LB-FT
Volts 208-230/460 Start Configuration direct on line
Full Load Amps 24.8-23.8/11.9 Breakdown Torque 66 LB-FT
R.P.M. 3525 Pull-up Torque 33.5 LB-FT
Hz 60 Phase 3 Locked-rotor Torque 37.5 LB-FT
NEMA Design Code B KVA Code K Starting Current 112 A
Service Factor (S.F.) 1.15 No-load Current 4.2 A
NEMA Nom. Eff. 91 Power Factor 93 Lineline Res. @ 25ºC 0.781 Ω
Rating - Duty 40C AMB-CONT Temp. Rise @ Rated Load 43°C
S.F. Amps 28.2-26.6/13.3 Temp. Rise @ S.F. Load 52°C
Locked-rotor Power Factor 34
Rotor inertia 0.347 LB-FT2
Load Characteristics 460 V, 60 Hz, 10 HP
% of Rated Load 25 50 75 100 125 150 S.F.
Power Factor 53 75 85 89 90 91 90
Efficiency 85.5 90.2 91.6 91.2 91 90 91.1
Speed 3579 3560 3540 3519 3498 3474 3506
Line amperes 5.3 7 9.2 11.6 14.3 17.1 13.2
Performance Graph at 460V, 60Hz, 10.0HP Typical performance - Not guaranteed values
LarkinD Text Box main junction box, size and location TBD
LarkinD Text Box additional junction box, size and location TBD
LarkinD Rectangle
LarkinD Line
Submittal Data
PROJECT:
REPRESENTATIVE:
ENGINEER:
CONTRACTOR:
UNIT TAG:
TYPE OF SERVICE:
SUBMITTED BY:
APPROVED BY:
ORDER NO.:
QUANTITY:
DATE:
DATE:
DATE:
Product photo could vary from the actual product
CRN 10-1 A-FGJ-A-E-HQQE
Vertical, multistage centrifugal pump with suction and discharge ports on same the level. Pump materials in contact with the liquid are in high-grade stainless steel (EN 1.4401)
(AISI 316)
Conditions of Service
Flow:
Head:
Efficiency:
Liquid: Water Temperature: 68 °F NPSH required: ft Viscosity:
Specific Gravity: 1.000
Pump Data
Max pressure at stated temperature: 363 psi / 250 °F Liquid temperature range: -4 .. 248 °F Maximum ambient temperature: 104 °F Approvals: CURUS Shaft seal: HQQE Product number: On request
Motor Data
Rated power - P2: 0.75 HP Rated voltage: 115/208-230 V Main frequency: 60 Hz Enclosure class: 54 Dust/Splashing Insulation class: B Motor protection: NONE Motor type: BALDOR
H [ft]
Q [US gpm]0 5 10 15 20 25 30 35 40 45 50 55 60 65 eta
CRN 10-1, 60Hz
P2
[HP]
0.0
0.2
0.4
0.6
NPSH
[ft]
1/8
LarkinD Text Box
NYCS000015351R00
LarkinD Text Box
WH172339
Part #: CRN10-1-A-FGJ-A-E-HQQE
0.75HP SEVERE DUTY
115/230, 1PH, 3500 RPM
Mechanical seal: Silicon Carbide / Silicon Carbide with EPDM elastomers
Id n ti fi c a ti o n
CRE, CRIE, CRNE 7
7. Identification
Type key
Key to codes
* Option. See the CR "Custom-built pumps" data booklet available on Grundfos Product Center. See QR code or link below.
http://net.grundfos.com/qr/i/96486346
Shaft sea
Example CR E 32 s -4 -2 -A -F -G -E -HQQE
Type range:
CR, CRI, CRN, CRT
Pump with integrated frequency converter
Flow rate [m3/h]
Undersize impeller (all impellers) CR 1s, CRI 1s, CRN 1s
Number of impellers
Number of reduced-diameter impellers
CR, CRE, CRN, CRNE 32, 45, 64
Code for pump version
Code for pipe connection
Code for materials
Code for rubber parts
Code for shaft seal
Code Description
Pump version
A Basic version
B Oversize motor
C CR compact
D Pump with pressure intensifier*
E Pump with certificate
F Pump for high temperatures (with air-cooled top)
G E-pump without control panel
H Horizontal version
I Different pressure rating
J E-pump with a different maximum speed
K Pump with low NPSH
L Pump including Grundfos CUE and certificate
M Magnetic drive
N With sensor
O Cleaned and dried
P Undersize motor
Q High-pressure pump with high-speed MGE motor*
R Belt driven pump
S High-pressure pump
T Thrust handling device*
U ATEX approved pump
V Cascade function
W Deep-well pump with ejector*
X Special version
Y Electropolished
Z Pumps with bearing flange
Pipe connection
A Oval flange
B NPT thread
CA FlexiClamp
CX Triclamp*
F DIN flange
FC DIN 11853-2 flange (collar flange)
FE EN 1092-1, type E
G ANSI flange
J JIS flange
N Changed diameter of ports
P PJE coupling (Victaulic type)
X Special version
Materials
A Basic version
B Tungsten carbide / Tungsten carbide
C Carbon free pump
D Carbon-graphite filled PTFE (bearings)/Tungsten carbide
E Pickled and passivated (Only Japan)
H Flanges and…
This is the start of the file's text. The full file is on GovTribe.