Addendum 003 - Equipment - Filter Elements R0.pdf

PDF 1 MB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Addendum 003 - Equipment - NSF PID Scope R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015355 Rev: 00

Description of Item: Filter Elements

Specification Section: 43 11 24

Deviations: See document NYCS000015385

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3: Tab 1 - NYCS000015412,CSS,Air Filter Elements,01.287

Pages 4-6: Tab 2 - NYCS000015245,AB1PRF7WH4,EMFLON,0.2UM,10INCH

Pages 7-9: Tab 3 - NYCS000015247,AB3PFR7WH4,EMFLON,0.2UM,30INCH

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

Doc Number: NYCS000015412R00 Doc Title: NYCS000015412,CSS,Air Filter Elements,01.287.docx

Components Specification Sections

The following specification sections are relevant to the approval of submittal NYCS000015355, Air Filter

Elements,01.287:

L‐897,Attachment No. 2 ‐ HNF‐SPEC‐63538, Section 43 11 24, Compressed Air System.

Any exceptions and clarifications to the specification section above can be found in submittal NYCS000015385, Es and Cs, Section 43 11 24.

Pall has taken exceptions and clarifications relevant to the air filter elements proposed.

Component Description

Filter Medium Double-layer PTFE Support / Drainage Polypropylene

Cage, Core, Fin End and End Cap

Polypropylene

Adaptor Polypropylene with internal stainless steel reinforcing ring

O-ring Seal Silicone Elastomer Ethylene Propylene Rubber

Emflon® PFRW Filter Cartridges For Sterile Filtration of Gases

Data Sheet FBPFRWENe

Emflon PFRW cartridges are sterilizing grade hydrophobic membrane filters designed for reliable retention of bacteria and high levels of phages in compressed gas and vent applications.

Description

The filter element features Pall’s advanced 0.2 micron rated polytetrafluoroethylene (PTFE) double-layer membranes, pleated with very high area into single open-end cartridges.

They are built to withstand demanding in situ steaming conditions in either the forward or reverse direction.

Even in the presence of high humidity or moisture, often the case in practice, Emflon PFRW cartridges provide sterile effluent and validated performance, ensuring process security. They are the cartridge of choice for critical sterile gas applications.

Features and Benefits

Emflon PFRW Filter Cartridges

Features Benefits

Strongly hydrophobic 100 % PTFE membranes

• Prevents wetting out in humid conditions, even after repeated use and steaming cycles, allowing for unimpeded gas throughput

High area pleated, robust double-layer membranes

• High throughputs and low pressure drops, with sizing resulting in compressor energy cost savings

• Excellent resistance to mechanical damage

Multi-cycle in situ steam challenged in forward and reverse direction

• Enhanced steaming resistance

0.2 micron sterilizing grade filters based on liquid bacteria removal

• Provides sterile effluent even in humid conditions, resulting in optimal protection of product, improved fermentation yields, and increased security in aseptic processes

Excellent aerosol bacteriophage retention performance

• Provides superior bacteriophage protection of microbial cultures

Sodium chloride aerosol challenged for particle removal to 0.003 micron

• High particle removal efficiency in dry gas

Water Intrusion Testable (WIT) • Enables in situ user integrity testing

100 % integrity tested prior to dispatch

• Documented quality

Individually serialized modules

• Full traceability to materials and production records

Materials of Construction

Quality

• Cartridges produced in a controlled environment

• Manufactured according to ISO 9001:2008 certified Quality

Management System

Food Contact Compliance

Please refer to the Pall website http://www.pall.com/foodandbev for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

LarkinD Text Box

NYCS000015245R02

LarkinD Text Box Part #: AB1PFR7WH4 10 inch, code 7 seal

Table 1 Table 2 Table 3

Part Number: AB PFR W

Table 1: Nominal Length

Code Length

056 127 mm (5") 1 254 mm (10") 2 508 mm (20") 3 762 mm (30")

Table 3: O-ring Seal Material

Code Description

H4 Silicone Elastomer

J Ethylene Propylene Rubber

Table 2: Adaptor

Code Description

27 SOE – single open end with flat closed end, 2 locking tabs and external 226 o-rings

3 SOE – single open end with flat closed end and external 222 o-rings

7 SOE – single open end with fin end, 2 locking tabs and external 226 o-rings

8 SOE – single open end with fin end and external 222 o-rings

28 SOE – single open end with fin end, 3 locking tabs and external 222 o-rings

Technical Information

Typical Flow Rates3

3 Typical clean Δp per 254 mm (10") cartridge, air at 20 °C (68 °F).

For gases other than air and for multi-round cartridge installations, please contact Pall for proper sizing.

Ordering Information This information is a guide to the part number structure and possible options.

For availability of specific options and housing details, please contact Pall.

0 200 400 600 800

500 100 150 200 250 300 350 450400

1 b ar g

2 b ar g

4 barg

3 b ar g 3 b ar g

Ve nt

Flow Rate (scfm)

Flow Rate (Nm3/h)

D iff er en tia l P re ss ur e

(m b ar d

Operating Characteristics in Compatible Gases1

Maximum Differential Pressure Operating Temperature

5.3 bard (77 psid) (forward) ≤20 °C (68 °F)

4.1 bard (60 psid) (forward) ≤80 °C (176 °F)

Typical Service Life2 under continuous operating conditions

Continuous gas service 12 months to 60 °C (140 °F) Vent service 6 months to 80 °C (176 °F)

Autoclave and Steaming4

Cumulative Steaming Time Operating Temperature

165 hours (1-hour cycles, forward) 142 °C (287 °F) 20 hours (1-hour cycles, reverse) 142 °C (287 °F)

Maximum Steaming Conditions Steaming Temperature

1.0 bard (15 psid) (forward) 125 °C (257 °F)

0.3 bard (4.3 psid) (forward) 142 °C (287 °F)

0.5 bard (7.3 psid) (reverse) 125 °C (257 °F)

0.2 bard (2.9 psid) (reverse) 142 °C (287 °F)

1 Air, nitrogen, or other compatible gases.

7 AB05 configurations only.

5 For further information, please contact Pall.

6 Available only in Codes 2 and 7.

4 For applications requiring autoclaving and sterlization, Pall recommends the use of Code 2 or Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Data shown for forward steam flow also indicates autoclave resistance.

D iff er en tia l P re ss ur e

(p si d

Example Part Number: AB1PFR7WH4 See bold reference code in tables.

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described, unless otherwise indicated. Actual operating conditions may affect the filter's performance.

Nominal Filter Area: 0.8 m2 (8.6 ft2) per 254 mm (10") module

2 For continuous gas flow above 60 °C (140 °F), Emflon HTPFRW filters are recommended. Emflon PFRW can be operated at higher temperatures for shorter periods.

Removal Performance

Emflon PFRW filters have a microbial removal rating of 0.2 micron in liquids and a particulate removal rating of 0.003 micron in dry gases.

• Tested with Brevundimonas diminuta liquid challenge at ≥ 107 cfu/cm2 effective filtration area, according to ASTM Method 838-

05. Provides sterile effluent according to FDA Guidelines (2004)

• Tested for particle removal at 0.003 micron in dry gases by NaCl aerosol CNC particle analysis

• Tested in accordance with ISO Standard for Compressed Air (ISO 8573-4 and test method ISO 12500-3:2009)5.

Pall has an excellent history of use of the Emflon PTFE membrane used in the Emflon PFRW filters, see ‘Validation Guide for Pall Emflon PFR Filter Cartridges’, USTR2114 (2) further demonstrating:

• MS-2 and PP7 bacteriophage aerosol challenge

• Brevundimonas diminuta aerosol challenge in forward and reverse direction and under long term challenge conditions in forward direction with humidified air

• Bacillus subtilis var niger spores aerosol challenge

LarkinD Text Box

LarkinD Highlight

LarkinD Highlight

LarkinD Text Box

LarkinD Text Box H4

LarkinD Highlight

LarkinD Text Box Part #: AB1PFR7WH4 10 inch, code 7 seal

FBPFRWENe December 2014

Pall Food and Beverage

25 Harbor Park Drive Port Washington, NY 11050 +1 516 484 3600 telephone +1 866 905 7255 toll free US foodandbeverage@pall.com

Visit us on the Web at www.pall.com/foodandbev

Pall Corporation has offices and plants throughout the world. For Pall representatives in your area, please go to www.pall.com/contact

Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.

Because of technological developments related to the products, systems, and/or services described herein, the data and procedures are subject to change without notice.

Please consult your Pall representative or visit www.pall.com to verify that this information remains valid.

© Copyright 2014, Pall Corporation. Pall, and Emflon are trademarks of Pall Corporation.

® Indicates a trademark registered in the USA. Filtration. Separation. Solution.SM is a service mark of Pall Corporation.

Figure 1: Emflon HTPFRW cartridges provide sterilization of high temperature gases and and can be considered for use in oxygen-enriched air applications.

Figure 2: Emflon PFW cartridges are designed for sterilization of large volume gases in compact installations.

Figure 3: Emflon PFAW cartridges offer exceptionally high flow rates and are used for less critical bioburden reduction in gases.

Pall’s Emflon filter family offers a variety of solutions for addressing microbial removal in air and gas applications.

Please contact Pall for further information.

Component Description

Filter Medium Double-layer PTFE Support / Drainage Polypropylene

Cage, Core, Fin End and End Cap

Polypropylene

Adaptor Polypropylene with internal stainless steel reinforcing ring

O-ring Seal Silicone Elastomer Ethylene Propylene Rubber

Emflon® PFRW Filter Cartridges For Sterile Filtration of Gases

Data Sheet FBPFRWENe

Emflon PFRW cartridges are sterilizing grade hydrophobic membrane filters designed for reliable retention of bacteria and high levels of phages in compressed gas and vent applications.

Description

The filter element features Pall’s advanced 0.2 micron rated polytetrafluoroethylene (PTFE) double-layer membranes, pleated with very high area into single open-end cartridges.

They are built to withstand demanding in situ steaming conditions in either the forward or reverse direction.

Even in the presence of high humidity or moisture, often the case in practice, Emflon PFRW cartridges provide sterile effluent and validated performance, ensuring process security. They are the cartridge of choice for critical sterile gas applications.

Features and Benefits

Emflon PFRW Filter Cartridges

Features Benefits

Strongly hydrophobic 100 % PTFE membranes

• Prevents wetting out in humid conditions, even after repeated use and steaming cycles, allowing for unimpeded gas throughput

High area pleated, robust double-layer membranes

• High throughputs and low pressure drops, with sizing resulting in compressor energy cost savings

• Excellent resistance to mechanical damage

Multi-cycle in situ steam challenged in forward and reverse direction

• Enhanced steaming resistance

0.2 micron sterilizing grade filters based on liquid bacteria removal

• Provides sterile effluent even in humid conditions, resulting in optimal protection of product, improved fermentation yields, and increased security in aseptic processes

Excellent aerosol bacteriophage retention performance

• Provides superior bacteriophage protection of microbial cultures

Sodium chloride aerosol challenged for particle removal to 0.003 micron

• High particle removal efficiency in dry gas

Water Intrusion Testable (WIT) • Enables in situ user integrity testing

100 % integrity tested prior to dispatch

• Documented quality

Individually serialized modules

• Full traceability to materials and production records

Materials of Construction

Quality

• Cartridges produced in a controlled environment

• Manufactured according to ISO 9001:2008 certified Quality

Management System

Food Contact Compliance

Please refer to the Pall website http://www.pall.com/foodandbev for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

LarkinD Text Box

NYCS000015247R02

LarkinD Text Box Part #: AB3PFR7WH4 30 inch, code 7 seal

Table 1 Table 2 Table 3

Part Number: AB PFR W

Table 1: Nominal Length

Code Length

056 127 mm (5") 1 254 mm (10") 2 508 mm (20") 3 762 mm (30")

Table 3: O-ring Seal Material

Code Description

H4 Silicone Elastomer

J Ethylene Propylene Rubber

Table 2: Adaptor

Code Description

27 SOE – single open end with flat closed end, 2 locking tabs and external 226 o-rings

3 SOE – single open end with flat closed end and external 222 o-rings

7 SOE – single open end with fin end, 2 locking tabs and external 226 o-rings

8 SOE – single open end with fin end and external 222 o-rings

28 SOE – single open end with fin end, 3 locking tabs and external 222 o-rings

Technical Information

Typical Flow Rates3

3 Typical clean Δp per 254 mm (10") cartridge, air at 20 °C (68 °F).

For gases other than air and for multi-round cartridge installations, please contact Pall for proper sizing.

Ordering Information This information is a guide to the part number structure and possible options.

For availability of specific options and housing details, please contact Pall.

0 200 400 600 800

500 100 150 200 250 300 350 450400

1 b ar g

2 b ar g

4 barg

3 b ar g 3 b ar g

Ve nt

Flow Rate (scfm)

Flow Rate (Nm3/h)

D iff er en tia l P re ss ur e

(m b ar d

Operating Characteristics in Compatible Gases1

Maximum Differential Pressure Operating Temperature

5.3 bard (77 psid) (forward) ≤20 °C (68 °F)

4.1 bard (60 psid) (forward) ≤80 °C (176 °F)

Typical Service Life2 under continuous operating conditions

Continuous gas service 12 months to 60 °C (140 °F) Vent service 6 months to 80 °C (176 °F)

Autoclave and Steaming4

Cumulative Steaming Time Operating Temperature

165 hours (1-hour cycles, forward) 142 °C (287 °F) 20 hours (1-hour cycles, reverse) 142 °C (287 °F)

Maximum Steaming Conditions Steaming Temperature

1.0 bard (15 psid) (forward) 125 °C (257 °F)

0.3 bard (4.3 psid) (forward) 142 °C (287 °F)

0.5 bard (7.3 psid) (reverse) 125 °C (257 °F)

0.2 bard (2.9 psid) (reverse) 142 °C (287 °F)

1 Air, nitrogen, or other compatible gases.

7 AB05 configurations only.

5 For further information, please contact Pall.

6 Available only in Codes 2 and 7.

4 For applications requiring autoclaving and sterlization, Pall recommends the use of Code 2 or Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Data shown for forward steam flow also indicates autoclave resistance.

D iff er en tia l P re ss ur e

(p si d

Example Part Number: AB1PFR7WH4 See bold reference code in tables.

The technical information provided is based on controlled laboratory tests done on typical production filters at the conditions described, unless otherwise indicated. Actual operating conditions may affect the filter's performance.

Nominal Filter Area: 0.8 m2 (8.6 ft2) per 254 mm (10") module

2 For continuous gas flow above 60 °C (140 °F), Emflon HTPFRW filters are recommended. Emflon PFRW can be operated at higher temperatures for shorter periods.

Removal Performance

Emflon PFRW filters have a microbial removal rating of 0.2 micron in liquids and a particulate removal rating of 0.003 micron in dry gases.

• Tested with Brevundimonas diminuta liquid challenge at ≥ 107 cfu/cm2 effective filtration area, according to ASTM Method 838-

05. Provides sterile effluent according to FDA Guidelines (2004)

• Tested for particle removal at 0.003 micron in dry gases by NaCl aerosol CNC particle analysis

• Tested in accordance with ISO Standard for Compressed Air (ISO 8573-4 and test method ISO 12500-3:2009)5.

Pall has an excellent history of use of the Emflon PTFE membrane used in the Emflon PFRW filters, see ‘Validation Guide for Pall Emflon PFR Filter Cartridges’, USTR2114 (2) further demonstrating:

• MS-2 and PP7 bacteriophage aerosol challenge

• Brevundimonas diminuta aerosol challenge in forward and reverse direction and under long term challenge conditions in forward direction with humidified air

• Bacillus subtilis var niger spores aerosol challenge

LarkinD Text Box

LarkinD Highlight

LarkinD Text Box

LarkinD Text Box H4

LarkinD Highlight

LarkinD Highlight

LarkinD Text Box Part #: AB3PFR7WH4 30 inch, code 7 seal

FBPFRWENe December 2014

Pall Food and Beverage

25 Harbor Park Drive Port Washington, NY 11050 +1 516 484 3600 telephone +1 866 905 7255 toll free US foodandbeverage@pall.com

Visit us on the Web at www.pall.com/foodandbev

Pall Corporation has offices and plants throughout the world. For Pall representatives in your area, please go to www.pall.com/contact

Please contact Pall Corporation to verify that the product conforms to your national legislation and/or regional regulatory requirements for water and food contact use.

Because of technological developments related to the products, systems, and/or services described herein, the data and procedures are subject to change without notice.

Please consult your Pall representative or visit www.pall.com to verify that this information remains valid.

© Copyright 2014, Pall Corporation. Pall, and Emflon are trademarks of Pall Corporation.

® Indicates a trademark registered in the USA. Filtration. Separation. Solution.SM is a service mark of Pall Corporation.

Figure 1: Emflon HTPFRW cartridges provide sterilization of high temperature gases and and can be considered for use in oxygen-enriched air applications.

Figure 2: Emflon PFW cartridges are designed for sterilization of large volume gases in compact installations.

Figure 3: Emflon PFAW cartridges offer exceptionally high flow rates and are used for less critical bioburden reduction in gases.

Pall’s Emflon filter family offers a variety of solutions for addressing microbial removal in air and gas applications.

Please contact Pall for further information.

Cover Page Information
Revision History and Approvals
Tab 1 - NYCS000015412,CSS,Air Filter Elements
Tab 2 - NYCS000015245,AB1PFR7WH4,EMFLON,0.2UM,10INCH
Tab 3 - NYCS000015247,AB3PFR7WH4,EMFLON,0.2UM,30INCH
Title: Air Filter Elements, 01.287
Document: NYCS000015355
Revision: 00
RevRow1: 0
NameCreated By: DMLarkin
DateCreated By: 11-DEC-2019
NameApproved By: JHoskins
DateApproved By: 11-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .