Addendum 003 - Analytical Instrumentation List R0 Pall Comments.pdf

PDF 2 MB Posted

Attached to
Request for Proposal - Construction Services for Project L-897, Central Plateau Water Treatment Facility
Solicitation number
338214
Issued by

View the file

Other files

File Type Posted
Addendum 003 - O and M Manual - Prelim Oper and Maint Manual - Template R0.pdf PDF
Addendum 003 - Equipment - Automatic Strainers R0.pdf PDF
Addendum 003 - Valves - Other Check Valves R0.pdf PDF
Addendum 003 - Recommended Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Tab 3 - Anchor Bolt List R0.pdf PDF
Addendum 003 - Valves - Butterfly Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - REMOTE IO 24VDC POWER PANEL.pdf PDF
Addendum 003 - Valves - Air Release Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation Valve List R0.pdf PDF
Addendum 003 - Valves - Auto Drain Valve R0.pdf PDF
Addendum 003 - Equipment - Commissioning Plan R0.pdf PDF
Addendum 003 - Valves - Diaphragm Valves R0.pdf PDF
Addendum 003 - VDL 006-006 RFP Const Bidder Pall Documents.xlsx XLSX spreadsheet
Addendum 003 - Valves - Other Solenoid Valves R0.pdf PDF
Addendum 003 - Electrical Drawings - FEED STRAINER PLC IO PANEL.pdf PDF
Addendum 003 - Valves - Other Air Pressure Valves R0.pdf PDF
Addendum 003 - Analytical Instrumentation - Flow Instrumentation R1.pdf PDF
Addendum 003 - Valves - Solenoid Valves R0.pdf PDF
Addendum 003 - Equipment - Actuator Torque Tables R1.pdf PDF
Addendum 003 - Equipment - Filter Elements R0.pdf PDF
Addendum 003 - Valves - Dual Disc Check Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks R0.pdf PDF
Addendum 003 - Equipment - Equipment List R0 - Pall Comments.pdf PDF
Addendum 003 - O and M Manual - System Functional Description (SFD) R0.pdf PDF
Addendum 003 - Electrical Drawings - MAIN CONTROL PANEL.pdf PDF
Addendum 003 - Electrical Drawings - MF VALVE RACK PANEL.pdf PDF
Addendum 003 - Electrical Drawings - Main CP 24VDC Power Panel.pdf PDF
Addendum 003 - Analytical Instrumentation - Level Instrumentation R1.pdf PDF
Addendum 003 - Valves - Air Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - FRP Tanks attachment.pdf PDF
Addendum 003 - Contractual Electrical Spare Parts List R0.pdf PDF
Addendum 003 - Equipment - Air System R1.pdf PDF
Addendum 003 - Analytical Instrumentation - Temperature Instrumentation R1.pdf PDF
Addendum 003 - Valves - Ball Valves R0.pdf PDF
Addendum 003 - Valves - Chemical Pressure Control Valves R0.pdf PDF
Addendum 003 - Major Electrical Comp R0.pdf PDF
Addendum 003 - Electrical Drawings - CIP CAUSTIC ROOM PLC IO PANEL.pdf PDF
Addendum 003 - Exceptions and Clarifications - Specification Cross Reference Matrix R0.pdf PDF
Addendum 003 - Equipment - Calibration Columns R0.pdf PDF
Addendum 003 - Equipment - Centrifugal Pumps R0.pdf PDF
Addendum 003 - Equipment - Indeeco Heater General Infor R0.pdf PDF
Addendum 003 - Mechanical Drawings - Membrane Train Assy Dwg R3.pdf PDF
Addendum 003.pdf PDF
Addendum 003 - Equipment - Wilden Pump General Information R0.pdf PDF
Addendum 003 - Equipment - Water Softener R0.pdf PDF
Addendum 003 - Electrical Drawings - Interconnect Diagram Pall Comments.pdf PDF
Addendum 003 - Analytical Instrumentation - Pressure Instrumentation R1.pdf PDF
Addendum 003 - Mechanical Drawings - P and ID R4 Pall Submittal Return Comments.pdf PDF
Addendum 003 - Valves - Water Pressure Control Valves R0.pdf PDF
Addendum 003 - Equipment - Other Strainers R0.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER PAGE OF SELLER’S SUBMITTAL

City Name: Hanford, WA - MSA

Pall Project No.: 01.000287

Job Number: Project L-897, Subcontract 70816

Task Register 6 (Task 1 – VI Submittal Package)

To: (Contractor)

Mission Support Alliance, LLC (MSA)

PO Box 650

Richland, WA 99352

From: (Subcontractor)

Pall Water

A Division of Pall Corporation

839 State Route 13

Cortland, NY 13045

Patty Willis

Phone: 607-758-1699

Name of Project: Hanford, WA, Central Plateau WTF

Pall Document Number: NYCS000015058 Rev: 00

Description of Item: Instrumentation List

Specification Section: N/A

Deviations: N/A

INDEX:

Page 1: Cover Page Information

Page 2: Revision History and Approvals

Page 3-7: Tab 1 Instrumentation List,NYCS000015058,rev00

Date: 12/19/2019

PALL ADVANCED SEPARATIONS SYSTEMS

DIVISION OF PALL CORPORATION, CORTLAND, NY

Rev Name Date Created By

Approved By

Created By

Approved By

Created By

Approved By

Created By

Approved By

Revision Description

Title

Document # Revision griffinju Text Box These commodities, technology, or software may only be exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is prohibited.

PALL MEMBRANE FILTRATION (MF) SYSTEM

INSTRUMENT LIST (REV 00)

HANFORD WA, CENTRAL PLATEAU WTF

PALL PROJECT: 01.000287

Pall P&ID Tag (s)

Customer P&ID Tag(s) Function SAP Material No(s) Manufacturer's Model and Part Number Data Sheet Document

Number(s) Instrument Range Measurement Span Process Connection(s) Installation by / Comments Power Subsystem

AIT-1611 SAM-AIT-1611 Raw Feed Water Alkalinity Analyzer TBD Hach EZ5000 Series, P/N: EZ5006.99.001402 NYCS000015174

Total Alkalinity: 10 to 5000 mg/L Free Alkalinity: 10 to 5000 mg/L Total Hardness: 10 to 1000 mg/L

Calcium Hardness: 10 to 5000 mg/L

Total Alkalinity: 10 to 5000 mg/L Free Alkalinity: 10 to 5000 mg/L Total Hardness: 10 to 1000 mg/L

Calcium Hardness: 10 to 5000 mg/L

Provided by Pall, Field Installed by Others.

Only available as 120VAC power device. 120 VAC Raw Water

AE-1612

AIT-1612

SAM-AE-1612

SAM-AIT-1612 Raw Feed Water pH Sensor & Analyzer

WH058700

WH069306

WH101807

pH Sensor: Hach P/N: DPD1P1 Sensor Flow Tee: Hach P/N: MH334N4NZ

24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 1 to 14 (pH) 1 to 14 (pH) 1" FNPT

(on Flow Tee) Provided by Pall, Field Installed by Others.

Sensor has integral 10m (33 FT) cable. 24 VDC Raw Water

AE-1613

AIT-1613

SAM-AE-1613

SAM-AIT-1613

Raw Feed Water Turbidimeter Sensor & Controller

WH110603

WH101807

Turbidimeter Sensor: Hach P/N: LXV445.99.10112 24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 0 to 700 NTU 0 to 50 NTU 1/4" OD Poly Tubing for Sample

Water Inlet & Drain Lines Provided by Pall, Field Installed by Others. 24 VDC Raw Water

AE/AIT-3006 SAM-AE/AIT-3006

MF Feed Water Manifold Turbidimeter

Sensor & Controller

WH110603

WH101807

Turbidimeter Sensor: Hach P/N: LXV445.99.10112 24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 0 to 700 NTU 0 to 50 NTU 1/4" OD Poly Tubing for Sample

Water Inlet & Drain Lines Provided by Pall, Field Installed by Others. 24 VDC MF Feed

AE/AIT-3007 SAM-AE/AIT-3007

MF Feed Water Manifold pH Sensor &

Analyzer

WH058700

WH069306

WH101807

pH Sensor: Hach P/N: DPD1P1 Sensor Flow Tee: Hach P/N: MH334N4NZ

24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 1 to 14 (pH) 1 to 14 (pH) 1" FNPT

(on Flow Tee) Provided by Pall, Field Installed by Others. 24 VDC MF Feed

AE/AIT-1016x (x=A,B,C,D)

SAM-AE/AIT-1016x (x = A,B,C,D)

MF Valve Rack * Filtrate Water Turbidimeter Sensor & Controller

(* = 1,2,3,4)

WH110603

WH101807

Turbidimeter Sensor: Hach P/N: LXV445.99.10112 24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 0 to 700 NTU 0 to 1000 mNTU 1/4" OD Poly Tubing for Sample

Water Inlet & Drain Lines Shop Installed on Valve Rack. 24 VDC Valve Rack

AE-4032

AIT-4032

SAM-AE-4032

SAM-AIT-4032

Filtrate Water Manifold pH Sensor & Analyzer

WH058700

WH069306

WH101807

pH Sensor: Hach P/N: DPD1P1 Sensor Flow Tee: Hach P/N: MH334N4NZ

24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 1 to 14 (pH) 1 to 14 (pH) 1" FNPT

(on Flow Tee) Provided by Pall, Field Installed by Others. 24 VDC Filtrate

AE-4001

AIT-4001

SAM-AE-4001

SAM-AIT-4001

Filtrate Water Manifold Turbidimeter Sensor & Controller

WH110603

WH101807

Turbidimeter Sensor: Hach P/N: LXV445.99.10112 24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 0 to 700 NTU 0 to 1000 mNTU 1/4" OD Poly Tubing for Sample

Water Inlet & Drain Lines Provided by Pall, Field Installed by Others. 24 VDC Filtrate

AE/AIT-4030 SAM-AIT-4030 Filtrate Water Manifold CL2 Analyzer WH104592

WH101807

Free CL2 Grab Panel: Hach P/N: LXV45B.99.11022 24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 0 to 20 ppm 0 to 20 ppm Inlet: 1/4" OD Tubing Port

Drain: 3/8" OD Tubing Port Provided by Pall, Field Installed by Others.

Free Chlorine Only Measurement. 24 VDC Filtrate

AE-5605

AIT-5605

CIPR-AE-5605

CIPR-AIT-5605 CIP Drain Line pH Sensor & Analyzer

WH058700

WH069306

WH101807

pH Sensor: Hach P/N: DPD1P1 Sensor Flow Tee: Hach P/N: MH334N4NZ

24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 1 to 14 (pH) 1 to 14 (pH) 1" FNPT

(on Flow Tee) Provided by Pall, Field Installed by Others.

Sensor has integral 10m (33 FT) cable. 24 VDC CIP

AE-5619

AIT-5619

CIPR-AE-5619

CIPR-AIT-5619 CIP Drain Line ORP Sensor & Analyzer

WH064661

WH069306

WH101807

ORP Sensor: Hach P/N: DPD1P5 Sensor Flow Tee: Hach P/N: MH334N4NZ

24VDC Controller: Hach P/N: LXV404.99.70552 NYCS000015174 -1500 mV to +1500mV -1500 mV to +1500mV 1" FNPT

(on Flow Tee) Provided by Pall, Field Installed by Others.

Sensor has integral 10m (33 FT) cable. 24 VDC CIP

AIT-6009 CA-AIT-6009 Compressed Air Dewpoint Transmitter WH101487, WH101896

Sensor: VAISALA P/N DMT143N1C1A1X0A0ASX (Customized for 10 BAR Pressure), 10-FT Cordset: TURCK P/N PKGV 4M-3/S90/S653 NYCS000015174 -80 to +20 DegC

(Dewpoint) -80 to +20 DegC

(Dewpoint) 1/2" MNPT Provided by Pall, Field Installed by Others. Crack open Side Bleed Valve V- 6009B slightly to allow Sample Air circulation across Dewpoint Transmitter sensor tip.

24 VDC

(3-Wire) Compressed Air

ANALYTICAL

Pall VAULT File: NYCS000015058 PAGE 1 of 5 12/16/2019

DEBEST

Highlight more

DEBEST

AE-4030

HANFORD WA, CENTRAL PLATEAU WTF

PALL PROJECT: 01.000287

Pall P&ID Tag (s)

Customer P&ID Tag(s) Function SAP Material No(s) Manufacturer's Model and Part Number Data Sheet Document

Number(s) Instrument Range Measurement Span Process Connection(s) Installation by / Comments Power Subsystem

FI-1611 SAM-FI-1611

Raw Feed Water Alkaline Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Required Analyzer Sample Flow is 6 to 18 liter/hr.

N/A Raw Water

FI-1612 SAM-FI-1612

Raw Feed Water pH Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Target Sample Flow ~ 18 liter/hr. N/A Raw Water

FE-1613 SAM-FE-1613

Raw Feed Water Turbidimeter

Sample Water Flow Sensor WH104275 Hach TU5X00 Flow Sensor: P/N: LQV160.99.00002 NYCS000015175 1.6 to 15.8 gal/hr 1.6 to 15.8 gal/hr 1/4" OD Poly Tubing Provided by Pall, Field Installed by Others.

Flow Sensor Cable Plugs into Turbidimeter Sensor (AE-*). (12 VDC) Raw Water

FE-3006 SAM-FE-3006

MF Feed Water Manifold Turbidimeter

Sample Water Rotometer WH104275 Hach TU5X00 Flow Sensor: P/N: LQV160.99.00002 NYCS000015175 1.6 to 15.8 gal/hr 1.6 to 15.8 gal/hr 1/4" OD Poly Tubing Provided by Pall, Field Installed by Others.

Flow Sensor Cable Plugs into Turbidimeter Sensor (AE-*). N/a MF Feed

FI-3007 SAM-FI-3007

MF Feed Water Manifold pH Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Target Sample Flow ~ 18 liter/hr. N/A MF Feed

FE-1016x (x = A.B.C.D)

SAM-FE-1016x (x = A,B,C,D)

MF Valve Rack * Filtrate Turbidimeter

Sample Water Flow Sensor (* = 1,2,3,4)

WH104275 Hach TU5X00 Flow Sensor: P/N: LQV160.99.00002 NYCS000015175 1.6 to 15.8 gal/hr 1.6 to 15.8 gal/hr 1/4" OD Poly Tubing Factory Installed on MF Racks. Flow Sensor Cable Plugs into Turbidimeter Sensor (AE-*). (12 VDC) Valve Rack

FE/FIT-1005x (x = A,B,C,D)

PTW-FIT-1005x (x = A,B,C,D)

MF Valve Rack * Feed Water Flow Meter

(* = 1,2,3,4) WH102840 Rosemount Model 8750W, P/N:

8750WDMT2A4FTSA080CA1DA1M4G1DWAXQ4 NYCS000015175 156 to 6139 gal/min 0 to 3000 gal/min 8" ANSI-150 Flanges Shop Installed on Valve Rack.

Local (Integral) Flow Transmitter. 24 VDC Valve Rack

FE/FIT-4305 BCKW-FIT-4305

Reverse Filtration(RF) Flow Meter

(PTFE/SS) WH102857 Rosemount Model 8750W, P/N:

8750WDMT2A4FTSA060CA1DA1M4G1DWAXQ4 NYCS000015175 90 to 3545 gal/min 0 to 2000 gal/min 6" ANSI-150 Flanges Provided by Pall, Field Installed by Others. PTFE Liner w/ 316SS Electrodes &

GND Rings, Local (Integral) Flow Transmitter. 24 VDC Reverse Flush (RF)

FE-4001 SAM-FE-4001

Filtrate Water Manifold Turbidimeter

Sample Water Flow Sensor WH104275 Hach TU5X00 Flow Sensor: P/N: LQV160.99.00002 NYCS000015175 1.6 to 15.8 gal/hr 1.6 to 15.8 gal/hr 1/4" OD Poly Tubing Provided by Pall, Field Installed by Others.

Flow Sensor Cable Plugs into Turbidimeter Sensor (AE-*). (12 VDC) MF Filtrate

FI-4032 SAM-FI-4032

Filtrate Water Manifold pH Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Target Sample Flow ~ 18 liter/hr. N/A MF Filtrate

FI-4030 SAM-FI-4030

Filtrate Water Manifold CL2 Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AH6A1AA13D10A NYCS000015175 9 to 90 liter/HR 9 to 90 liter/HR 1/4" FNPT Provided by Pall, Field Installed by Others.

Required Analyzer Sample Flow is 30 to 50 liter/hr.

N/A MF Filtrate

FI-5605 CIPR-FI-5605

CIP Drain Line pH Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Target Sample Flow ~ 18 liter/hr. N/A CIP

FI-5619 CIPR-FI-5619

CIP Drain Line ORP Analyzer

Sample Water Rotometer TBD Brooks Model GT1600, P/N: 1640AG6A1AA13D10A NYCS000015175 3.5 to 35 liter/hr 3.5 to 35 liter/hr 1/4" FNPT Provided by Pall, Field Installed by Others.

Target Sample Flow ~ 18 liter/hr. N/A CIP

FSL-5203A CIPS-FSL-5203A

CIP Circulation Pump #1

Low Flow Switch

WH041369,

WH101225

Flow Switch: Turck P/N:

FCS-N1/2 A4P-AP8X-H1141/L100

Cable Plug: Memcon P/N MDC-4FP-FW11 NYCS000015175 2 - 295 ft/min (Field Adjustable) 1/2" MNPT 4" (100mm) Long Insertion Probe. 4-Pin M12 Cable Plug Requires

3-Conductor / #18 AWG Signal Cable. 3-Wire PNP CIP

FSL-5203B CIPS-FSL-5203B

CIP Circulation Pump #2

Low Flow Switch

WH041369,

WH101225

Flow Switch: Turck P/N:

FCS-N1/2 A4P-AP8X-H1141/L100

Cable Plug: Memcon P/N MDC-4FP-FW11 NYCS000015175 2 - 295 ft/min (Field Adjustable) 1/2" MNPT 4" (100mm) Long Insertion Probe. 4-Pin M12 Cable Plug Requires

3-Conductor / #18 AWG Signal Cable. 3-Wire PNP CIP

FE/FIT-5017 NA-FIT-5017

Sodium Hydroxide Transfer System

Flow Meter (PTFE/SS)

WH103758

WH101259

Rosemount Model 8750W, P/N:

8750WDMR2A4FTSA005CA1DA1M4G1AXQ4

Sensor Cable: P/N 08732-0065-2001 (Per FT) NYCS000015175 0.95 to 37.3 gal/min 0 to 15 gal/min 1/2" ANSI-150 Flanges Provided by Pall, Field Installed by Others. PTFE Liner w/ 316SS Electrodes &

GND Rings, Remote Transmitter w/ 25 FT Pall Supplied Sensor Cable. 24 VDC Chem Transfer

FE/FIT-5121 CTA-FIT-5121

Blended Acid Transfer System

Flow Meter (PTFE/SS)

WH103758

WH101259

Rosemount Model 8750W, P/N:

8750WDMR2A4FTSA005CA1DA1M4G1AXQ4

Sensor Cable: P/N 08732-0065-2001 (Per FT) NYCS000015175 0.95 to 37.3 gal/min 0 to 15 gal/min 1/2" ANSI-150 Flanges Provided by Pall, Field Installed by Others. PTFE Liner w/ 316SS Electrodes &

GND Rings, Remote Transmitter w/ 25 FT Pall Supplied Sensor Cable. 24 VDC Chem Transfer

FE/FIT-5405 HCL-FIT-5405

Sodium Hypochlorite Transfer System Flow

Meter (PTFE/Hastalloy)

WH103759

WH101259

Rosemount Model 8750W, P/N:

8750WDMR2A4FTHA005CA1DA1M4G2AXQ4

Sensor Cable: P/N 08732-0065-2001 (Per FT) NYCS000015175 0.95 to 37.3 gal/min 0 to 15 gal/min 1/2" ANSI-150 Flanges

Provided by Pall, Field Installed by Others. PTFE Liner w/ Hasatalloy Electrodes & GND Rings, Remote Transmitter w/ 25 FT Pall Supplied Sensor

Cable.

24 VDC Chem Transfer

FE/FIT-5505 CTS-FIT-5505

Calcium Thiosulfate Transfer System

Flow Meter (PTFE/Hastalloy)

WH103758

WH101259

Rosemount Model 8750W, P/N:

8750WDMR2A4FTSA005CA1DA1M4G1AXQ4

Sensor Cable: P/N 08732-0065-2001 (Per FT) NYCS000015175 0.95 to 37.3 gal/min 0 to 15 gal/min 1/2" ANSI-150 Flanges Provided by Pall, Field Installed by Others. PTFE Liner w/ 316SS Electrodes &

GND Rings, Remote Transmitter w/ 25 FT Pall Supplied Sensor Cable. 24 VDC Chem Transfer

FIT-6035A CA-FIT-6035A Scrub Air System #1 Flow Meter WH103780 FCI ST100L In-Line Thermal Mass, P/N:

STL100L-43J800012CF1EE00000 NYCS000015175 0.0062 to 838 SCFM 0 to 400 SCFM 2" FNPT Provided by Pall, Field Installed by Others.

Remote Transmitter w/ 50 FT Factory Supplied Sensor Cable. 24 VDC Compressed Air

FIT-6035B CA-FIT-6035B Scrub Air System #2 Flow Meter WH103780 FCI ST100L In-Line Thermal Mass, P/N:

STL100L-43J800012CF1EE00000 NYCS000015175 0.0062 to 838 SCFM 0 to 400 SCFM 2" FNPT Provided by Pall, Field Installed by Others.

Remote Transmitter w/ 50 FT Factory Supplied Sensor Cable. 24 VDC Compressed Air

FLOW

Pall VAULT File: NYCS000015058 PAGE 2 of 5 12/16/2019

NKUTIL

Pen

NKUTIL

Text Box

NAOCL

NKUTIL

Pen

NKUTIL

Pen

NKUTIL

HANFORD WA, CENTRAL PLATEAU WTF

PALL PROJECT: 01.000287

Pall P&ID Tag (s)

Customer P&ID Tag(s) Function SAP Material No(s) Manufacturer's Model and Part Number Data Sheet Document

Number(s) Instrument Range Measurement Span Process Connection(s) Installation by / Comments Power Subsystem

LEVEL

LSHH-5002 CIP-LSHH-5002 CIP CausticTank High High Level Switch (12" Long Hastallloy Probe) WH102839

12" Hastalloy Ultra-Sonic Gap Sensor:

Drexelbrook P/N: 705-0001-005-CA0304.8

Hastalloy Level Switch Transmitter:

Drexelbrook P/N: 5041100005S00090

NYCS000015264 Trip Point Field Adjustable, DPDT Relay Output

Trip Point Field Adjustable, DPDT Relay Output

3/4" NPT Provided by Pall, Field Installed by Others.

Sensor is Factory Assembled to Switch. Hastalloy Wetted Parts. 24 VDC CIP

LSLL-5003 CIP-LSLL-5003 CIP Caustic Tank Low Low Level Switch (12" Long Hastalloy Probe) WH102839

12" Hastalloy Ultra-Sonic Gap Sensor:

Drexelbrook P/N: 705-0001-005-CA0304.8

Hastalloy Level Switch Transmitter:

Drexelbrook P/N: 5041100005S00090

NYCS000015264 Trip Point Field Adjustable, DPDT Relay Output

Trip Point Field Adjustable, DPDT Relay Output

3/4" NPT Provided by Pall, Field Installed by Others.

Sensor is Factory Assembled to Switch. Hastalloy Wetted Parts. 24 VDC CIP

LSHH-5102 CIP-LSHH-5102 CIP Acid Tank High High Level Switch (12" Long SS Probe) WH102838

12" SS Ultra-Sonic Gap Sensor:

Drexelbrook P/N: 705-0001-001-BA0304.8

316 SS Level Switch Transmitter:

Drexelbrook P/N: 5041100001S00090

NYCS000015264 Trip Point Field Adjustable, DPDT Relay Output

Trip Point Field Adjustable, DPDT Relay Output

3/4" NPT Provided by Pall, Field Installed by Others.

Sensor is Factory Assembled to Switch. 316L-SS Wetted Parts. 24 VDC CIP

LSLL-5103 CIP-LSLL-5103 CIP Acid Tank Low Low Level Switch (12" Long SS Probe) WH102838

12" SS Ultra-Sonic Gap Sensor:

Drexelbrook P/N: 705-0001-001-BA0304.8

316 SS Level Switch Transmitter:

Drexelbrook P/N: 5041100001S00090

NYCS000015264 Trip Point Field Adjustable, DPDT Relay Output

Trip Point Field Adjustable, DPDT Relay Output

3/4" NPT Provided by Pall, Field Installed by Others.

Sensor is Factory Assembled to Switch. 316L-SS Wetted Parts. 24 VDC CIP

LIT-5006 CIP-LIT-5006 CIP Caustic Tank Level Transmitter (Hastalloy) WH104594 Rosemount Model 3051T, P/N:

3051TG1A2B31AC6Q4M5 NYCS000015264 0 to 30 PSI (0 to 831 Inch WC) 0 to 100 % Level 1/2" FNPT Provided by Pall, Field Installed by Others.

Hastalloy Wetted Parts.

24 VDC

Loop CIP

LIT-5106 CIP-LIT-5106 CIP Acid Tank Level Transmitter (316L SS) WH104593 Rosemount Model 3051T, P/N:

3051G1A2B21AC6Q4M5 NYCS000015264 0 to 30 PSI (0 to 831 Inch WC) 0 to 100 % Level 1/2" FNPT Provided by Pall, Field Installed by Others.

316L-SS Wetted Parts.

24 VDC

Loop CIP

LIT-5100 CTA-LIT-5100 Blended Acid Transfer System Tote Level Transmitter (316L SS) WH104593 Rosemount Model 3051T, P/N:

3051TG1A2B21AC6Q4M5 NYCS000015264 0 to 30 PSI (0 to 831 Inch WC) 0 to 100 % Level 1/2" FNPT Provided by Pall, Field Installed by Others.

No Iso. Diaphragm, 316SS Wetted Parts Compatible with Acid.

24 VDC

Loop Chem Transfer

LIT-5010 CTS-LIT-5501 Sodium Hydroxide System Tote Level Transmitter (316L SS) WH104593 Rosemount Model 3051T, P/N:

3051TG1A2B21AC6Q4M5 NYCS000015264 0 to 30 PSI (0 to 831 Inch WC) 0 to 100 % Level 1/2" FNPT Provided by Pall, Field Installed by Others.

No Iso. Diaphragm, 316SS Wetted Parts Compatible with NaOH.

24 VDC

Loop Chem Transfer

LIT-5501 CTS-LIT-5501 Calcium Thiosulfate Transfer System Tote Level Transmitter (316L SS) WH104593 Rosemount Model 3051T, P/N:

3051TG1A2B21AC6Q4M5 NYCS000015264 0 to 30 PSI (0 to 831 Inch WC) 0 to 100 % Level 1/2" FNPT Provided by Pall, Field Installed by Others.

No Iso. Diaphragm, 316SS Wetted Parts Compatible with CaO3S2.

24 VDC

Loop Chem Transfer

Pall VAULT File: NYCS000015058 PAGE 3 of 5 12/16/2019

NKUTIL

Rectangle

NKUTIL

Callout

PALL SHALL PLEASE CONFIRM COMPATIBILITY OF 316 SST WITH THESE CHEMICALS

NKUTIL

Pen

NKUTIL

Text Box

NAOH-LIT-5010

NKUTIL

Text Box CIP-LSHH-5101 Tank Leak CIP-LSHH-5001 Tank Leak

LG-5101

LG-5001

HomR Text Box PALL COMMENT: Tank Leak Detector, LG-5101, LG-5001 will be included in the next revision of the Instrument List and Instrument Cut Sheets.

HomR Text Box

PALL COMMENTS:

(a) Per Cole-Palmer materials compatibility database, 316 Stainless-Steel compatibility with NaOH (20%) is GOOD.

(b) Jesco chemical resistance chart of 316 Stainless-Steel with Calcium Thiosulfate is rated "B".

(c) Cole-Palmer database indicates 316 Stainless-Steel compatibility with 10%-70% Sulfuric Acid is POOR, therefore, Blended Acid Tank Level Transmitter LIT-5100/CTA-LIT-5100 wetted materials will be changed to Hastalloy C-276 which has compatibility rating of GOOD. This update will appear on the next revision of the Instrumentation List.

HomR Rectangle

HANFORD WA, CENTRAL PLATEAU WTF

PALL PROJECT: 01.000287

Pall P&ID Tag (s)

Customer P&ID Tag(s) Function SAP Material No(s) Manufacturer's Model and Part Number Data Sheet Document

Number(s) Instrument Range Measurement Span Process Connection(s) Installation by / Comments Power Subsystem

PI-1600 (None) Raw Water Analytical Sample Line Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI

(0 to 414 KPA) 0 to 60 PSI

(0 to 414 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Raw Water

PI-1007x (x = A,B,C,D)

CA-PI-1007x (x = A,B,C,D)

MF Valve Rack * Scrub Air Pressure Gauge

(* = 1,2,3,4) WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI

(0 to 414 KPA) 0 to 60 PSI

(0 to 414 KPA) 1/2" FNPT Shop installed on Valve Rack.

316SS Wetted Parts. N/A Valve Rack

PI-1099x (x = A,B,C,D)

CA-PI-1099x (x = A,B,C,D)

MF Valve Rack * IT Air Pressure Gauge

(* = 1,2,3,4) WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI

(0 to 414 KPA) 0 to 60 PSI

(0 to 414 KPA) 1/2" FNPT Shop installed on Valve Rack.

316SS Wetted Parts. N/A Valve Rack

PI-3271 (None) MF Feed Strainer Drain Manifold Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI

(0 to 414 KPA) 0 to 60 PSI

(0 to 414 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A MF Feed

PI-4353A BCKW-PI-4353 RF Pump #1 Inlet Line Pressure Gauge WH032216 Ashcroft P/N: 45-1279SSL-04L-30"HG/0/30PSI/KPA NYCS000015265 30" HG Vacuum to +30 PSI/KPA 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-4353B BCKW-PI-4354 RF Pump #2 Inlet Line Pressure Gauge WH032216 Ashcroft P/N: 45-1279SSL-04L-30"HG/0/30PSI/KPA NYCS000015265 30" HG Vacuum to +30 PSI/KPA 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-4353C BCKW-PI-4355 RF Pump #3 Inlet Line Pressure Gauge WH032216 Ashcroft P/N: 45-1279SSL-04L-30"HG/0/30PSI/KPA NYCS000015265 30" HG Vacuum to +30 PSI/KPA 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-4302A BCKW-PI-4302 RF Pump #1 Outlet Line Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI /KPA 0 to 60 PSI /KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-4302B BCKW-PI-4303 RF Pump #2 Outlet Line Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI /KPA 0 to 60 PSI /KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-4302C BCKW-PI-4305 RF Pump #3 Outlet Line Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI /KPA 0 to 60 PSI /KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A RF

PI-5001A (None) CIP CausticTank Recirc Pump Inlet Pressure Gauge WH032216 Ashcroft P/N: 45-1279SSL-04L-30"HG/0/30PSI/KPA NYCS000015265 30" HG Vacuum to +30 PSI/KPA 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A CIP

PI-5001B (None) CIP CausticTank Recirc Pump Outlet Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI /KPA 0 to 60 PSI /KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A CIP

PI-5101A (None) CIP Acid Tank Recirc Pump Inlet Pressure Gauge WH032216 Ashcroft P/N: 45-1279SSL-04L-30"HG/0/30PSI/KPA NYCS000015265 30" HG Vacuum to +30 PSI/KPA 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A CIP

PI-5101B (None) CIP Acid Tank Recirc Pump Outlet Pressure Gauge WH042113 Ashcroft P/N: 45-1279SSL-04L-60PSI/KPA NYCS000015265 0 to 60 PSI /KPA 0 to 60 PSI /KPA 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A CIP

PE/PI-5239A CIPS-PE/PI-5239A CIP Circulation Pump #1 Inlet Line Pressure Gauge TBD

Pressure Gauge:

Ashcroft P/N: 45-1279 SSL–04L-XLL-30"HG/0/30PSI /KPA

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 30" HG Vacuum to +30 PSI

(-101 to 207 KPA) 30" HG Vacuum to +30 PSI

(-101 to 207 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS

Diaphragm, Housings & Flurocarbon Fill Liquid. N/A CIP

PE/PI-5239B CIPS-PE/PI-5239B CIP Circulation Pump #2 Inlet Line Pressure Gauge TBD

Pressure Gauge:

Ashcroft P/N: 45-1279 SSL–04L-XLL-30"HG/0/30PSI /KPA

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 30" HG Vacuum to +30 PSI

(-101 to 207 KPA) 30" HG Vacuum to +30 PSI

(-101 to 207 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS

Diaphragm, Housings & Flurocarbon Fill Liquid. N/A CIP

PE/PI-5281A CIPS-PE/PI-5281A CIP Circulation Pump #1 Outlet Line Pressure Gauge TBD

Pressure Gauge:

Ashcroft P/N: 45-1279 SSL–04L-XLL-60 PSI /KPA

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 0 to 60 PSI

(0 to 413 KPA) 0 to 60 PSI

(0 to 413 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS

Diaphragm, Housings & Flurocarbon Fill Liquid. N/A CIP

PE/PI-5281B CIPS-PE/PI-5281B CIP Circulation Pump #2 Outlet Line Pressure Gauge TBD

Pressure Gauge:

Ashcroft P/N: 45-1279 SSL–04L-XLL-60 PSI /KPA

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 0 to 60 PSI

(0 to 413 KPA) 0 to 60 PSI

(0 to 413 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS

Diaphragm, Housings & Flurocarbon Fill Liquid. N/A CIP

PI-6014A CA-PI-6014A Instrument Air System #1 Pressure Gauge WH042116 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-160 PSI /KPA NYCS000015265 0 to 160 PSI

(0 to 1102 KPA) 0 to 160 PSI

(0 to 1102 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PI-6014B CA-PI-6014B Instrument Air System #2 Pressure Gauge WH042116 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-160 PSI /KPA NYCS000015265 0 to 160 PSI

(0 to 1102 KPA) 0 to 160 PSI

(0 to 1102 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PI-6020A CA-PI-6020A Scurb Air System #1 Pressure Gauge WH042113 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-60 PSI /KPA NYCS000015265 0 to 60 PSI

(0 to 413 KPA) 0 to 60 PSI

(0 to 413 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PI-6020B CA-PI-6020B Scurb Air System #2 Pressure Gauge WH042113 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-60 PSI /KPA NYCS000015265 0 to 60 PSI

(0 to 413 KPA) 0 to 60 PSI

(0 to 413 KPA) 1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PI-6018 CA-PI-6018 Compressed Air Receiver T-6010 Pressure Gauge WH042117 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-300PSI /KPA NYCS000015265 0 to 300 PSI (0 to 2067 KPA)

0 to 300 PSI (0 to 2067 KPA)

1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PI-6048 CA-PI-6048 Compressed Air Receiver T-6040 Pressure Gauge WH042117 Ashcroft 1279 Series, P/N: 45-1279SSL–04L-300PSI /KPA NYCS000015265 0 to 300 PSI (0 to 2067 KPA)

0 to 300 PSI (0 to 2067 KPA)

1/2" FNPT Provided by Pall, Field Installed by Others.

316SS Wetted Parts. N/A Compressed Air

PSL-6001 CA-PSL-6001 Compressed Air Receiver T-6010 Low Pressure Switch TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI) NYCS000015265 0 to 200 PSI 0 to 200 PSI

(Field Adjustable; SPDT Output) 1/2" FNPT Provided by Pall, Field Installed by Others.

Same as Chem Transfer PISH but no Isolation Seal. 24 VDC Compressed Air

PSL-6041 CA-PSL-6041 Compressed Air Receiver T-6040 Low Pressure Switch TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI) NYCS000015265 0 to 200 PSI 0 to 200 PSI

(Field Adjustable; SPDT Output) 1/2" FNPT Provided by Pall, Field Installed by Others.

Same as Chem Transfer PISH but no Isolation Seal. 24 VDC Compressed Air

PI-7100 (None) Sodium Hypchlorite Transfer System Recirculation Pump Inlet Pressure Gauge TBD

Pressure Gauge:

Ashcroft P/N: 45-1279 SSL–04L-XLL-30"HG/0/30PSI /KPA

Isolation Seal: Ashcroft P/N: 50-200 H H 04T XCF XSE NYCS000015265 30" HG Vacuum to +30 PSI

(-101 to 207 KPA) 30" HG Vacuum to +30 PSI/KPA 1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has Hastalloy Diaphragm, Housings & Flurocarbon Fill Liquid. N/A Chem Transfer

PISH-5015 CTS-PISH-5502 Sodium Hydroxide Transfer System High Pressure Indicating Switch TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI)

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 0 to 200 PSI 0 to 200 PSI (Field Adjustable; SPDT Output)

1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS Diaphragm, Housings & Flurocarbon Fill Liquid. 24 VDC Chem Transfer

PISH-5115 CTS-PISH-5115 Blended Acid Transfer System High Pressure Indicating Swtich TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI)

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 0 to 200 PSI 0 to 200 PSI (Field Adjustable; SPDT Output)

1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS Diaphragm, Housings & Flurocarbon Fill Liquid. 24 VDC Chem Transfer

PISH-5402 HCL-PISH-5402 Sodium Hypochlorite Transfer System High Pressure Indicating Switch TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI)

Isolation Seal: Ashcroft P/N: 50-200 H H 04T XCF XSE NYCS000015265 0 to 200 PSI 0 to 200 PSI (Field Adjustable; SPDT Output)

1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has Hastalloy Diaphragm, Housings & Flurocarbon Fill Liquid. 24 VDC Chem Transfer

PISH-5502 CTS-PISH-5502 Calcium Thiosulfate Transfer System High Pressure Indicating Switch TBD Pressure Switch: Ashcroft P/N: NPI-N4L-SO6 (200 PSI)

Isolation Seal: Ashcroft P/N: 50-200 S S 04T XCF XSE NYCS000015265 0 to 200 PSI 0 to 200 PSI (Field Adjustable; SPDT Output)

1/2" FNPT Provided by Pall, Field Installed by Others. Isolation Seal has 316SS Diaphragm, Housings & Flurocarbon Fill Liquid. 24 VDC Chem Transfer

PRESSURE

Pall VAULT File: NYCS000015058 PAGE 4 of 5 12/16/2019

NKUTIL

Pen

NKUTIL

Pen

NKUTIL

Pen r

NKUTIL

Pen

NKUTIL

Text Box

NKUTIL

Text Box

NKUTIL

Text Box

NKUTIL

Pen

NKUTIL

Pen

NKUTIL

Text Box

NAOCL

NKUTIL

Pen

NKUTIL

Text Box

NAOH-PISH-5015

DEBEST

Text Box

SAM-PI-1600

DEBEST

Text Box

SBW-PI-3271

DEBEST

Highlight

DEBEST

Highlight

HANFORD WA, CENTRAL PLATEAU WTF

PALL PROJECT: 01.000287

Pall P&ID Tag (s)

Customer P&ID Tag(s) Function SAP Material No(s) Manufacturer's Model and Part Number Data Sheet Document

Number(s) Instrument Range Measurement Span Process Connection(s) Installation by / Comments Power Subsystem

PIT-3070 PTW-PIT-3070 MF Feed Water Manifold Pressure Transmitter WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC

Loop MF Feed

PIT-3005 PTW-PIT-3005 MF Feed Strainer Inlet Manifold Pressure Transmitter WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC

Loop MF Feed

PIT-3009 PTW-PIT-3009 MF Feed Strainer Outlet Manifold Pressure Transmitter WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC Loop MF Feed

PIT-1004x (x = A,B,C,D)

PTW-PIT-1004x (x = A,B,C,D)

MF Valve Rack * Feed Water Pressure Gauge Transmitter

(* = 1,2,3,4) WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Shop Installed on Valve Rack. 24VDC Loop Valve Rack

PIT-1021x (x = A,B,C,D)

FT-PIT-1021x (x = A,B,C,D)

MF Valve Rack * Filtratate Water Pressure Transmitter

(* = 1,2,3,4) WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Shop Installed on Valve Rack. 24VDC Loop Valve Rack

PIT-4003 FT-PIT-4003 MF Filtrate Water Manifold Pressure Transmitter WH104595 Rosemount Model 3051T, P/N:

3051TG2A2B21AC6DWQ4M5 NYCS000015265 0 to 150 PSI 0 to 100 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC

Loop MF Filtrate

PIT-6011 CA-PIT-6001 Compressed Air Receiver T-6010 Pressure Transmitter WH104596 Rosemount Model 3051T, P/N:

3051TG3A2B21AC6DWQ4M5 NYCS000015265 0 to 800 PSI 0 to 200 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC Loop Compressed Air

PIT-6040 CA-PIT-6040 Compressed Air Receiver T-6040 Pressure Transmitter WH104596 Rosemount Model 3051T, P/N:

3051TG3A2B21AC6DWQ4M5 NYCS000015265 0 to 800 PSI 0 to 200 PSI 1/2" FNPT Provided by Pall, Field Installed by Others. 24VDC Loop Compressed Air

TEMPERATURE

TE/TIT-1609 EW-TIT-1609 Raw Feed Water 12" SS Thermowelled Temperature Sensor & Display Transmitter

WH102331,

WH102332,

WH103069

Rosemount:

12"SS Thermowell: 114CE0120TAA3SC032BXW RTD Sensor: 214CRTSMB1S4E0152SLXWXA

Transmitter: 3144PD1A1K6M5Q4XA

NYCS000015266

Sensor: -58 to 752 DegF (-50 to 400 DegC) Transmitter: -40 to 188 DegF

(-40 to 86.7 DegC)

32 to 212 DegF (0 to 100 DegC)

1/2"-ANPT Provided by Pall, Field Installed by Others.

Parts Factory Assembled, 316 SS Thermowell, LCD Operator Display.

24VDC

Loop Raw Water

TE/TIT-3008 PTW-TIT-3008 MF Feed Water 12" SS Thermowelled Temperature Sensor & DisplayTransmitter

WH102331,

WH102332,

WH103069

Rosemount:

12"SS Thermowell: 114CE0120TAA3SC032BXW RTD Sensor: 214CRTSMB1S4E0152SLXWXA

Transmitter: 3144PD1A1K6M5Q4XA

NYCS000015266

Sensor: -58 to 752 DegF (-50 to 400 DegC) Transmitter: -40 to 188 DegF

(-40 to 86.7 DegC)

32 to 212 DegF (0 to 100 DegC)

1/2"-ANPT Provided by Pall, Field Installed by Others.

Parts Factory Assembled, 316 SS Thermowell, LCD Operator Display.

24VDC

Loop MF Feed

TE/TIT-5007 CIP-TIT-5007 CIP Caustic Tank 18" Hastalloy Thermowelled Temperature Sensor & Dispaly Transmitter

WH102333,

WH102334,

WH103069

Rosemount:

18"Hast.Thermowell: 114CE0180TAA3AC032BXW

RTD Sensor: 214CRTSMB1S4E0212SLXWXA Transmitter: 3144PD1A1K6M5Q4XA

NYCS000015266

Sensor: -58 to 752 DegF (-50 to 400 DegC) Transmitter: -40 to 188 DegF

(-40 to 86.7 DegC)

32 to 212 DegF (0 to 100 DegC)

1/2"-ANPT Provided by Pall, Field Installed by Others.

Parts Factory Assembled, Hastalloy Thermowell, LCD Operator Display.

24VDC

Loop CIP

TE/TIT-5107 CIP-TIT-1507 CIP Acid Tank 18" SS Thermowelled Temperature Sensor & Display Transmitter

WH102335,

WH102334,

WH103069

Rosemount:

18"SS Thermowell: 114CE0180TAA3SC032BXW RTD Sensor: 214CRTSMB1S4E0212SLXWXA

Transmitter: 3144PD1A1K6M5Q4XA

NYCS000015266

Sensor: -58 to 752 DegF (-50 to 400 DegC) Transmitter: -40 to 188 DegF

(-40 to 86.7 DegC)

32 to 212 DegF (0 to 100 DegC)

1/2"-ANPT Provided by Pall, Field Installed by Others.

Parts Factory Assembled, 316 SS Thermowell, LCD Operator Display.

24VDC

Loop CIP

INSTRUMENT LIST REVISION HISTORY

REVISION NO. DATE INITIALS

00 12-16-2019 RH

PRESSURE (continued)

DESCRIPTION OF REVISION

Pall VAULT File: NYCS000015058 PAGE 5 of 5 12/16/2019

NKUTIL

Pen

NKUTIL

Text Box

NKUTIL

Pen

NKUTIL

Text Box

DEBEST

Cloud

DEBEST

Text Box

FURNISH WITH 2-VALVE MANIFOLDS

DEBEST

Highlight

DEBEST

Text Box

HomR

PALL COMMENT: NSF Drinking Water compatibility preclude use of 2-Valve Manifolds. Discrete NSF compliant ball valves are being used where appropriate.

Cover Sheet - CUSTOM.pdf
PASS2005034 Engg Stds Datasheet cover page template.pdf
Sheet1
PASS2005037 Engg Stds Custom Datasheet cover page template.pdf
Sheet1
Title: Pall Instrumentation List, 01.287
Document: NYCS000015058
Revision: 00
RevRow1: 00
NameCreated By: R. Hom
DateCreated By: 11-DEC-2019
NameApproved By: M. Loomis
DateApproved By: 16-DEC-2019
Revision DescriptionRow1: Initial Issue
RevRow2:
NameCreated By_2:
DateCreated By_2:
NameApproved By_2:
DateApproved By_2:
Revision DescriptionRow2:
RevRow3:
NameCreated By_3:
DateCreated By_3:
NameApproved By_3:
DateApproved By_3:
Revision DescriptionRow3:
RevRow4:
NameCreated By_4:
DateCreated By_4:
NameApproved By_4:
DateApproved By_4:
Revision DescriptionRow4:

File details come from the government source that posted it. Updated .