21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_49.pdf

PDF 421 KB Posted

Attached to
FPCM-LAC-I001104-M035-RS
Solicitation number
0000036277
Issued by
Los Angeles County, California

About this file

This technical drawing is a mechanical and plumbing details sheet (MP502) for the California State Prison, Los Angeles County (LAC) located in Lancaster, California, specifically for the Place Roofs - Phase 1 project. The document, prepared by Turley Mechanical Engineering & Associates Group and Hibser Yamauchi Architects, details roofing and mechanical installation specifications for the facility. The drawing includes detailed technical diagrams for water heater piping, multiple roof pipe penetrations, duct installation on and through roofs, and pipe installation through curbs, with specific instructions for reusing existing equipment where feasible and providing new solenoid valves and connections.

The project is part of the State of California Department of Corrections and Rehabilitation's Facility Planning, Construction and Management Division design services, with working drawings dated August 31, 2023. The technical specifications emphasize precise installation methods, including using 24-gauge flashing, single-ply roofing, polyurethane insulation, and specific mounting and sealing techniques. The Office of the State Fire Marshal has approved the plans for fire and panic safety, with an approval date of 10/10/23 and an approval number of 23-0002. The job number is JT 22107-PH1, and the project indicates careful attention to matching existing infrastructure and field verification of dimensions and connections.

View the file

Other files

File Type Posted
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_14.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_30.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_36.pdf PDF
I-001104_-_21-040_-_002_-_Roof_Penetrations.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_10.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_37.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_9.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_13.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_32.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_48.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_26.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_21.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_51.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_6.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_31.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_25.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_38.pdf PDF
21-039_LAC_Replace_Roofs_Volume_1.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_34.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_27.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_40.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_7.pdf PDF
21-039_LAC_Replace_Roofs_Volume_2.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_23.pdf PDF
12_-_FPCM-LAC-I001104-M035-RS.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_47.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_42.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_33.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_12.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_16.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_3.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_20.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_18.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_46.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_39.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_35.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_22.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_5.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_24.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_28.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_43.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_15.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_50.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_4.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_19.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_8.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_29.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_17.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_41.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_45.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(E)11

4"CD, REUSE AS

MUCH AS FEASIBLE.

(E)CD

(E)SOLENOID VALVE,

TO BE REUSED

(E)MPG

(N)SOV

(E)CW FOR EVAP

COOLER, REUSE AS

MUCH AS FEASIBLE.

REPLACE, SEE

(E)GAS REGULATOR,

TO BE REUSED,

SEE H

MP501

NOTE:

WHEN (E)AHU'S ARE REINSTALLED, RECONNECT (E)G, CW, CD AND DISCHARGE DRAIN

TO UNIT, PROVIDE (N)SOV'S, OFFSET AND EXTENSIONS WHERE NECESSARY. SIZE TO

MATCH (E)

FIELD VERIFY AND RECORD ACTUAL PIPE CONNECTION FOR EACH AHU ON EACH

BUILDING.

(N)SOV (N)SOV

I

MP501

ROOFING INSULATION

(N)SINGLE PLY ROOF UP CURB

24 GAUGE

FLASHING

(N)EXTENDED DUCT

(E)RIGID INSULATION

(E)DUCT CURB.

16 GA. ANGLE 2½"x1½"

CONTINUOUS

POLYURETHANE

SEALANT#8 SMS (MIN) @

MAX 4"OC

(N)SELF-ADEHERED,

FLEX-FLASHING

UNDERLAYMENT

#10 SMS @ 6"OC ALL AROUND

(E)DUCT

4" SMS, 12"O.C., MIN

(2)EACH SIDE, MIN

(8)TOTAL

(N)14" SMS. 12"O.C.,

MIN (2)EACH SIDE,

MIN (8)TOTAL

NOTES:

1. EXTEND (E)DUCT AND PROVIDE (N)OFFSET FITTINGS. SIZE AND

GAUGE OF (N)DUCT AND FITTINGS MATCH (E)

2. FIELD MEASURE (E)CURB SIZE FOR MATCHING UP W/ NEW CURB

ADAPTOR.

MIN 10"

RIGID INSULATION

(POLYISOCYANURATE)

MIN 11

2" THICK

(E)CONCRETE OVER METAL

DECK

APPROXIMATE POC

(N) CURB EXTENSION 14 GA CONTRACTOR

FABRICATED W/ WELDED JOINTS OR

MANUFACTURED BY THY BAR OR MICROMETAL.

ALL DIMENSIONS VERIFIED IN FIELD TO MATCH

WITH EXISTING CONDITIONS.

(E)ANCHORAGE

(N)CURB

(N)PVC FLASHING

EXTEND UP ON CURB

(N)PVC FLASHING

MATERIAL AROUND PIPE

PIPE CLAMP

SEALANT ALL AROUND

PERIMETER

(N)ICW, SIZE MATCH (E)

PIPE THRU CURB

(E)CONCRETE OVER

METAL DECK

(N)INSULATION

(N)FINISHED ROOF

(E)CURB

(N)CURB ADAPTOR

(E)EXHAUST FAN,

MOUNTING DETAIL SEE

CURB HEIGHT REFER

TO THIS DETAIL

A

MP501

(E)ICW

(N)ICW

POC

(N)ICW THRU CURB

Project Engineer:

U R L E YT M E C H A N IC A L

E N G I N E E R I N G

G R O U P, I N C.& ASSOCIATES

(916) 325-1065

FAX: (916) 325-1075

Email: office@turleymech.com

2431 Capitol Avenue Sacramento, CA 95816

Project Manager:

GYang

Job Number:

Project Drafter: Login:

Plot Date: Aug 25, 2023 - 4:07pm

22107-PH1JT

JT

SHEET NUMBER

S

TA

TE

O

F C

A

LI

FO

R N

IA

D

E P A R

TM

E N

T O

F C

O R R

E C

TI

O

N S A

N D

R E H

A B

IL

IT

A

TI

O N

FA

C

IL

IT

Y P

LA

N

N

IN

G , C

O N

S

TR

U C

TI

O

N A

N D

M A N

A G

E M

E N

T D

IV

IS

IO

N

DE

SI

G N

SE

RV

IC

ES

A

ND

S

TA

ND

AR

DS

B

RA

NC

H

DE

SI

G

N

SE

RV

IC

ES

S

EC

TI

O N

APPROVAL

L A C

V1

C A L

IF

O R

N

IA

S T A T E P

R

IS

O N

L O

S A

N G

E L E S C

O U

N T Y

T H

S T R

E E T , W

E S T

LA

N

C A S T E R

, C A

R E P L A C

E R

O O

F S

P H

A S E

A U

G U

S T

W O

R K

IN

G D

R A W

IN

G

S

. 1

A rc h it e ct s, I n c.

H

IB

S E R Y

A M

A U C

H I n d S tr e e t, S u it e

D a vi s, C

A

.7

.1 o ff ic e

.7

.4 f a x

MP502

M E C

H A N

IC

A L P

L U M

B

IN

G D

E T A

IL

S

V1

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

10/10/23

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

23-0002

11/20/2023 CASp-491 #1317

File details come from the government source that posted it. Updated .