21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_35.pdf
PDF 421 KB Posted
- Attached to
- FPCM-LAC-I001104-M035-RS
- Solicitation number
- 0000036277
- Issued by
- Los Angeles County, California
About this file
This document is a mechanical/plumbing roof plan remodel drawing for the California State Prison, Los Angeles County (LAC), specifically targeting Housing Unit Buildings 346 and 347, prepared by Turley Mechanical Engineering & Associates Group and Hibser Yamauchi Architects. The project involves a comprehensive roof replacement and equipment repositioning, with work focused on reinstalling and reconnecting existing mechanical units including air handling units (AHUs), air conditioning units, exhaust fans, water heaters, and associated piping and ductwork. The drawing is dated August 31, 2023, and has received approval from the California Department of Corrections and Rehabilitation's Facility Planning, Construction and Management Division, with fire safety approval obtained on 10/10/23.
The drawing provides detailed technical specifications for repositioning roof-mounted equipment, including requirements for new curb adaptors, flashing, piping reconnections, and duct modifications. Notable technical requirements include field verification of existing equipment details, ensuring proper startup and operation of all systems, and matching existing pipe and fitting materials. The project involves 30 plumbing vent pipes, multiple gas, water, and condensate drain line reconfigurations, and careful preservation of existing infrastructure. The State Fire Marshal has approved the plans, subject to field inspection, with a final approval date of 11/20/2023, indicating this is a carefully regulated state infrastructure improvement project.
View the file
Other files
Show 40 more
Latest 50 of 55 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 61.8 2 3 4 5 7 118 9 10
A
B
C
B.4
F
D
E
H
G
J
K
K.8
L
M
1 111.8 2 3 4 5 6 7 8 9 105.7 7.3
A
B
B.7
D
E.7
G.3
J
K.7
L
M
K
H
E
C
F
G
D14
08 08 08 08 08 08 08 08
07 07 07 07 07 07 07 07
070808 08080808 08 08 0707070707 07 07 07
(E)AC-1
(E)AHU-1
(E)AHU-2
(E)AHU-3
(E)EF-1(E)EF-2 (E)EF-3 (E)EF-4
(E)EF-5
(E)EF-6 (E)EF-7 (E)EF-8 (E)EF-9
(E)EF-32
(E)EF-10
(E)EF-11
(E)EF-12
(E)EF-13
(E)EF-30
(E)EF-14
(E)EF-15
(E)EF-16
(E)EF-17
(E)EF-29
(E)EF-28
(E)EF-18 (E)EF-19 (E)EF-20 (E)EF-21 (E)EF-22 (E)EF-23 (E)EF-24 (E)EF-25 (E)EF-26
(E)EF-27
(E)EF-31
(E)EF-33
(E)WH-1
(E)AC-2
(E)1 14"CD
(E)1 14"CD
(E)11
4"CD
D14
(E)3 4"ICW
(E)11
2"MPG
(E)3 4"MPG
(E)3 4"MPG
(E)3 4"MPG
HU 346 & HU 347 ONLY
(E)3 4"CD
(E) 3 4"CD
HU 346 & HU
347 ONLY
HU 346 & HU
347 ONLY
(E)3 4"MPG
16A
Project Engineer:
U R L E YT M E C H A N IC A L
E N G I N E E R I N G
G R O U P, I N C.& ASSOCIATES
(916) 325-1065
FAX: (916) 325-1075
Email: office@turleymech.com
2431 Capitol Avenue Sacramento, CA 95816
Project Manager:
GYang
Job Number:
Project Drafter: Login:
Plot Date: Aug 25, 2023 - 4:07pm
22107-PH1JT
JT
SHEET NUMBER
S
TA
TE
O
F C
A
LI
FO
R N
IA
D
E P A R
TM
E N
T O
F C
O R R
E C
TI
O N
S A
N D
R E H
A B
IL
IT
A
TI
O N
FA
C
IL
IT
Y P
LA
N
N
IN
G , C
O N
S
TR
U C
TI
O
N A
N D M
A N
A G
E M
E N
T D
IV
IS
IO
N
DE
SI
G N
SE
RV
IC
ES
A
ND
S
TA
ND
AR
DS
B
RA
NC
H
DE
SI
G
N
SE
RV
IC
ES
S
EC
TI
O N
APPROVAL
L A C
V1
C A L
IF
O R
N
IA
S T A T E P
R
IS
O N
L O
S A
N G
E L E S C
O U N
T Y
T H
S T R
E E T , W
E S T
LA
N
C A S T E R
, C A
R E P L A C E R
O O
F S
P H
A S E
A U
G U
S T
W O
R K
IN
G D
R A W
IN
G
S
.1
A rc h it e ct s, I n c.
H
IB
S E R Y
A M
A U C
H I n d S tr e e t, S u it e
D a vi s, C
A
.7
.1 o ff ic e
.7
.4 f a x
MPC301
M E C
H A N
IC
A L P
L U
M B
IN
G
H
U B
U
IL
D
IN
G S
T
H R
U
R O
O F P
L A N
R E M
O D
E L
REMODEL NOTES
GENERAL NOTES
(E) G, CW, HW, HWR UTR, RECONNECTED, PROVIDE (N)CURB ADAPTOR FOR
MULTIPLE PIPES OR (N)FLASHING FOR SINGLE PIPE. PROVIDE NECESSARY
OFFSET. SINGLE PIPE PENERTRATION DETAIL SEE
MULTIPLE PIPE PENETRATION DETAIL SEE
16A (E) INDUSTRIAL COLD WATER PIPING PENETRATE INTO CURB, TEMPORARY
DISCONNECTED, RE-ROUTED AND RECONNECTED. DETAIL SEE
18 RECONNECT (E) NATURAL GAS PIPING CONNECT TO AC OR AHU W/ (E)PRESSURE
REGULATOR. DETAIL SEE
RE-INSTALL (E) AHU ON (N) RAISED CURB. RECONNECT ALL CONTROLS, PIPING,
DRAINS AND DUCTING. PROVIDE EXACT MEASUREMENTS OF CURB FOR THE
ADDITION OF A CURB EXTENDER. VERIFY DUCT SIZE. MOUNTING DETAIL SEE
, PIPING (GAS, WATER AND DRAIN) CONNECTION SEE
05 RE-INSTALL (E) AC UNIT ON (N) RAISED CURB. RECONNECT ALL CONTROLS,
PIPING, DRAINGS AND DUCTING. VERIFY DUCT SIZE. PROVIDE EXACT
MEASUREMENTS OF CURB FOR THE ADDITION OF A CURB ADAPTOR. MOUNTING
DETAIL SEE , GAS PIPE CONNECTION DETAIL SEE ,
CONDENSATE DRAIN CONNECTION SEE
RE-INSTALL (E) EXHAUST FAN ON (N) RAISED CURB, PROVIDE EXACT
MEASUREMENTS OF CURB FOR THE ADDITION OF A CURB ADAPTOR. SEE
DETAIL
(N) PLUMBING VENT PIPE @ (E) PENETRATION, TOTAL 30 VENT ON ROOF WITHIN
CONSTRUCTION AREA. RAISE VENT TO MAINTAIN REQUIRED DISTANCE FROM
TOP OF VENT TO TOP OF ROOF. DETAIL SEE
(E) CONDENSATE DRAIN (D) THRU ROOF, RECONNECTED, PROVIDE NEW FLASHING
AND NEW OFFSET. DETAIL SEE
(E) CONDENSATE DRAIN PIPING, TO BE REINSTALLED. PROVIDE NECESSARY
OFFSET FOR NEW HEIGHT OF CURB. NEW PIPE SIZE IS TO MATCH EXISTING.
REPLACE (E)PIPING WITH SAME SIZE (N)PIPING IS ACCEPTABLE. PIPE SUPPORT
DETAIL SEE
(E) INDUSTRIAL COLD WATER PIPING, TO BE REINSTALLED. PROVIDE NECESSARY
OFFSET FOR NEW HEIGHT OF CURB. NEW PIPE SIZE IS TO MATCH EXISTING.
REPLACE (E)PIPING WITH SAME SIZE (N)PIPING IS ACCEPTABLE. PIPE SUPPORT
DETAIL SEE
(E) INDUSTRIAL COLD WATER PIPE (R) THRU ROOF, RECONNECTED, PROVIDE NEW
FLASHING AND NEW OFFSET. DETAIL SEE
(E) MEDIUM PRESSURE NATURAL GAS PIPING, TO BE REINSTALLED. PROVIDE
NECESSARY OFFSET FOR NEW HEIGHT OF CURB. NEW PIPE SIZE IS TO MATCH
EXISTING. REPLACE (E)PIPING WITH SAME SIZE (N)PIPING IS ACCEPTABLE. PIPE
SUPPORT DETAIL SEE
(E) 36X24 DUCT ON ROOF, REINSTALLED AND PROVIDE NEW DUCT SUPPORT.
DETAIL SEE
(E) DUCT THRU ROOF. PROVIDE NEW CURB EXTENSION AND EXTEND/MODIFY
DUCT. RE-INSULATE DUCT. DETAIL SEE
G
MP501
H,I
MP501
A
MP502
E
MP501
H
MP501
I
MP501
A
MP501
B
MP501
C
MP501
F
MP501
D
MP501
F
MP501
C
MP502
D
MP501
H
MP501
D
MP502
B
MP502
G
MP502
F
MP501
(E)AHU-1 THRU 3 EXISTING HANDLING UNIT, "ENERGY LAB" UNIT W/
"REZNOR" NATURAL GAS FURNACE AND EVAP COOLER,
MODEL# AND DETAILED INFORMATION UNKNOWN.
(E)AC-1 EXISTING AIR CONDITIONING UNIT ON HIGH ROOF,
ROOF TOP UNIT W/ NATURAL GAS FURNACE,
MANUFACTURE, MODEL# AND DETAILED INFORMATION
UNKNOWN.
(E)AC-2 EXISTING AIR CONDITIONING UNIT ON LOW ROOF ROOF
TOP UNIT MANUFACTURE, MODEL# AND DETAILED
INFORMATION UNKNOWN.
(E)EF-1 THRU 33 EXISTING EXHAUST FAN, UNIT MODEL# AND DETAILED
INFORMATION UNKNOWN.
(E)WH-1 EXISTING WATER HEATER ON HIGH ROOF.
"TURBOPOWER" LOW NOX CATEGORY I FAN-ASSISTED
STORAGE WATER HEATER, 500 LHE 250A-TPL, 250
GALLON, 399,000 BTU/HR NATURAL GAS INPUT,
4.5"-10.5" W.C. GAS INLET PRESSURE, 120V/1PH/60 HZ,
5AMPS.
NOTES:
1. NO AS-BUILT DRAWING FOR THE BUILDINGS. NAMEPLATE FOR
MOST UNITS CANNOT BE FOUND OR NOT READABLE. CONTRACTOR
SHALL FIELD VERIFY ACTUAL UNIT INFORMATION FOR EACH BUILDING.
2. MANY AHU'S WERE FOUND TO BE LEAKING. THEY MUST BE
REPAIRED PRIOR TO REROOFING.
EXISTING EQUIPMENT SCHEDULE
N
N
BUILDING 347BUILDING 346
19 RE-INSTALL (E) WATER HEATER ON (N) CURBS. RECONNECT ALL CONTROLS
AND PIPING, MOUNTING DETAIL SEE AND , WATER PIPE
CONNECTION DETAIL SEE ,
NATURAL GAS PIPE CONNECTION SEE
A906 F
MP502
H
MP501
1. PROVIDE START UP OF ALL EQUIPMENT TO ENSURE IT IS OPERATING
PROPERLY. SEE GENERAL MECHANICAL/PLUMBING NOTES ON MP001.
2. WHERE SIZES ARE LARGER THAN SHOWN, MATCH (E)SIZES TO
MAINTAIN THE SAME SIZE AS EXISTING CONDITIONS.
3. FIELD VERIFY EXISTING GAS PIPE MATERIAL AT EACH BUILDING.
MATERIAL OF NEW GAS PIPING AND FITTINGS SHALL MATCH EXISTING
PIPING MATERIAL.
4. FIELD VERIFY EXACT HEIGHT OF EACH (E) CURB. IF TOP (E)CURB IS
EQUAL TO OR MORE THAN 8" ABOVE NEW FINISHED ROOF TOP, (E)UNIT
ON THE CURD CAN BE REMAIN IN PLACE AND PROTECTED DURING
CONSTRUCTION. INSTALL (N)FLASHING ON (E)CURB AFTER
REROOFING.
S501
V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/10/23
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
23-0002
11/20/2023 CASp-491 #1317