This document is an electrical roof remodel plan for Facility A 270 Housing Unit Building 334 at California State Prison, Los Angeles County, prepared by M. Neil Engineering for the California Department of Corrections and Rehabilitation (CDCR). The plan details electrical modifications for a roof replacement project, specifically focusing on extending existing electrical circuits, replacing conduits and wiring, reinstalling mechanical units, and updating electrical equipment. The project is located at 44750 60th Street West in Lancaster, California, and involves precise electrical infrastructure updates for the housing unit building.
The electrical plan includes comprehensive instructions for maintaining existing circuit continuity and equipment functionality, with specific requirements for replacing disconnects, manual starters, receptacles, and junction boxes. Key specifications include using new EMT with compression fittings, liquid-tight flexible metal conduit, and ensuring all new electrical components match existing voltage, phase, and current ratings. The drawings are dated August 29, 2023, with working drawings submitted on August 31, 2023, and have received approval from the Office of the State Fire Marshal on October 10, 2023. The project number is 5843.10, and the engineering firm's project number is 21318.21.
View the file
Other files
Show 40 more
Latest 50 of 55 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3 1 1.8 2 6 4 5 7 8 9 1110
B.4
A
B
D
C
J
E
F
G
H
K
K.8
L
M
1 111.8 2 3 4 5 6 7 8 9 105.7 7.3
A
B
B.7
D
E.7
G.3
J
K.7
L
M
(E)
(E) (3) 3/4" CONDUITS
IN PITCH POCKET
(E) 1-1/2" CONDUIT UP
THROUGH ROOF
(E) (3) 3/4" CONDUITS
IN PITCH POCKET
(E) (2) 3/4" CONDUITS
IN PITCH POCKET
J
(E) 3/4" CONDUIT UP
THROUGH ROOF TO
J-BOX
(E) CONTROL
PANELS
(E) 1-1/2" CONDUIT UP
THROUGH ROOF
(E) (4) 3/4" CONDUITS
UP THROUGH ROOF
(E) MAIN CIRCUIT
BREAKER
DISCONNECT
J
(E) CONTROL
PANELS
(E) MAIN CIRCUIT
BREAKER
DISCONNECT
(E) 1-1/2" CONDUIT UP
THROUGH ROOF
(E) (4) 3/4" CONDUITS
UP THROUGH ROOF
(E) 3/4" CONDUIT UP
THROUGH ROOF TO
J-BOX
J
(E) 3/4" CONDUIT UP
THROUGH ROOF TO
J-BOX
(E) 1-1/2" CONDUIT UP
THROUGH ROOF
(E) (4) 3/4" CONDUITS
UP THROUGH ROOF
(E) CONTROL
PANELS
(E) MAIN CIRCUIT
BREAKER
DISCONNECT
(E) BEACON
(E) 1/2" CONDUIT ON
TOP OF PARAPET
J
(E) 3/4" CONDUIT UP
THROUGH ROOF
(E) 3/4" CONDUIT DOWN
SIDE OF BUILDING
(E) 3/4" CONDUIT
(E) (1) 3/4" CONDUIT
AND (E) 1/2" CONDUIT
J
(E) GUARD SHACK
(E) 3/4" CONDUIT ON
PARAPET WALL
(E) 3/4" CONDUIT ON
TOP OF PARAPET
(E) CONDUIT
DOWN WALL
(E)
(E) 1" CONDUIT UP
THROUGH PLATFORM
(E) (3) 3/4" CONDUITS
UP THROUGH ROOF
TO DUCT DETECTORS
AND CONTROLS
(E) (3) 3/4" CONDUITS
UP THROUGH ROOF
TO DUCT DETECTORS
AND CONTROLS
(E) (3) 3/4" CONDUITS
UP THROUGH ROOF
TO DUCT DETECTORS
AND CONTROLS
(E) 3/4" CONDUIT UP
THROUGH ROOF
(E) 3/4" CONDUIT UP
THROUGH ROOF
WP
11 8 9 10
G.3
J
K.7
L
M
SLO
PE
SLO
PE
7 7.3
J (E)
J
J
(E) CONDUIT ON
WALL TO REMAIN
GENERAL NOTES
1. EXTEND EXISTING CIRCUITS, WIRING AND CONDUITS AND RECONNECT TO EXISTING RELOCATED
MECHANICAL, LIGHTING AND ELECTRICAL EQUIPMENT. REUSE SAME CIRCUIT TO FEED SAME
MECHANICAL AND ELECTRICAL EQUIPMENT, AS PRIOR TO CONSTRUCTION. MAINTAIN EXISTING
CIRCUIT CONTINUITY AND EQUIPMENT FUNCTIONALITY. ALL ABOVE ROOF CONDUIT AND WIRING MUST BE REPLACED WITH NEW . WIRE SIZE, QUANTITY AND TYPE SHALL MATCH EXISTING. SPLICE IN POWER WIRING IS NOT ACCEPTABLE. NEW CONTROL WIRING TO HVAC EQUIPMENT MAY ONLY BE INSTALLED
FOR THE RUN FROM THE EQUIPMENT CONTROL PANEL TO THE NEAREST EXISTING TERMINATION
POINT OR SPLICE LOCATION INSTALL NEW EMT WITH COMPRESSION FITTINGS AND LIQUID-TIGHT
FLEXIBLE METAL CONDUIT TERMINATION AT THE MECHANICAL EQUIPMENT.
2. REPLACE EXISTING DISCONNECT/MANUAL STARTERS WITH NEW TO FEED SAME HVAC, AS PRIOR TO
CONSTRUCTION. NEW DISCONNECT/STARTER TO MATCH EXISTING TYPE, VOLTAGE, PHASE, AND
CURRENT RATING. REPLACE ALL EXISTING WEATHERPROOF GFCI SERVICE RECEPTACLES WITH NEW
WP/WR/GFCI RECEPTACLES THAT ARE TO CURRENT CODE.
3. PROVIDE NEW WEATHERPROOF, NEMA 3R JUNCTION BOXES AND WATERTIGHT FLEX CONDUITS FOR EACH MECHANICAL AND ELECTRICAL EQUIPMENT. KEEP EXISTING CONDUIT PENETRATIONS AT THE
SAME LOCATIONS AS PRIOR TO CONSTRUCTION.
4. PROVIDE BLOCKING AND CHANNELS TO CONDUIT RACEWAY AS NEEDED ON ROOFTOP. COORDINATE
WITH MECHANICAL AND PLUMBING CONTRACTORS FOR JOINT USE BLOCKING. SEE "2/E9.001"
NUMBERED NOTES
REINSTALLED MECHANICAL UNIT. RECONNECT EXISTING POWER AFTER ROOFING REPLACEMENT.
SEE DETAIL "1/E9.001" ON SHEET E9.001.
REPLACE EXISTING RECEPTACLE WITH NEW GFCI, WEATHER PROOF, WEATHER RESISTANT
RECEPTACLE.
LOCATE AND INTERCEPT EXISTING CIRCUIT AND CONTROLS BELOW ROOF DECK. SPLICE AND
EXTEND TO RAISED EQUIPMENT AND RE-CONNECT. TYPICAL FOR ALL MECHANICAL UNITS
MOUNTED ON RAISED ROOF.
EXISTING RSC LOCATED ON ROOF TO BE REINSTALLED AFTER ROOFING REPLACEMENT. FIELD
VERIFY QUANTITIES AND SIZES. REFER TO DETAIL "1/E9.001" ON SHEET E9.001.
EXISTING RSC LOCATED ON TOP OF PARAPET TO BE REINSTALLED AFTER ROOFING
REPLACEMENT. FIELD VERIFY QUANTITIES AND SIZES. REFER TO DETAIL "1/E9.001" ON SHEET E9.001.
EXISTING RSC LOCATED ON PARAPET WALL TO BE REINSTALLED AFTER ROOFING REPLACEMENT.
FIELD VERIFY QUANTITIES AND SIZES. REFER TO DETAIL "1/E9.001" ON SHEET E9.001.
PROVIDE NEW GFCI, WEATHER PROOF, WEATHER RESISTANT RECEPTACLE WITH METAL
WHILE-IN-USE COVER. CONNECT TO THE EXISTING ROOF RECEPTACLE CIRCUIT.
ALL CONDUIT RUN EXPOSED ON THE ROOF SHALL BE SUPPORTED PER DETAIL "2/E9.001".
SUPPORT SPACING SHALL BE PER DETAIL "2/E9.001", NOTES 1 AND 2.
SHEET NUMBER
S
TA
TE
O
F C A
LI
FO
R N
IA
D
E P A R
TM
E N
T O
F C
O R R
E C
TI
O
N S A
N D R
E H
A B
IL
IT
A
TI
O N
FA
C
IL
IT
Y P
LA
N
N
IN
G , C
O N
S
TR
U C
TI
O N
A N
D M
A N
A G
E M
E N
T D
IV
IS
IO
N
DE
SI
G N
SE
RV
IC
ES
A
ND
S
TA
ND
AR
DS
B
RA
NC
H
DE
SI
G
N
SE
RV
IC
ES
S
EC
TI
O N
APPROVAL
L A C
V1
C A L
IF
O R
N
IA
S T A T E P
R
IS
O N
L O
S A
N G
E L E S C
O U
N T Y
T H
S T R
E E T , W
E S T
LA
N
C A S T E R
, C A
.1
Electrical Engineers Lighting Designers
100 Howe Ave., Suite 235N
Sacramento, CA 95825-8217
PROJECT #:
www.mneilsengineering.com
Tel: (916) 923-4400
PROJECT MGR: Stuart LinGsa\
21318.21
08/29/2023
R E P L A C E R
O O
F S
P H
A S E
A U
G U
S T
W O
R K
IN
G D
R A W
IN
G
S
1/8"=1'-0"
FACILITY A 270 HOUSING UNIT BUILDING 334 ROOF PLAN - REMODEL - ELECTRICAL1
EB301
EB301
F A
C
IL
IT
Y A
H O
U S
IN
G U
N
IT
B U
IL
D
IN
G
R
O O
F P
L A
N
R E M
O D
E L E
L E C
T R
IC
A L
1/8"=1'-0"
ROOF PLAN - REMODEL - ELECTRICAL2
EB301
PARTIAL SECOND LEVEL AND
FACILITY A 270 HOUSING UNIT BUILDING 334
5'
1/8" = 1'-0"
0 25'10' 15' 20'
GRAPHIC SCALE
N
N
09/13/2023
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/10/23
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
23-0002
11/20/2023 CASp-491 #1317
File details come from the government source that posted it. Updated .