This architectural drawing set is for a roof replacement project at California State Prison, Los Angeles County (LAC), located at 44750 60th Street West in Lancaster, California. The document, prepared by the California Department of Corrections and Rehabilitation's Facility Planning, Construction and Management Division, details building sections for a Phase 1 roof replacement project dated August 31, 2023. The drawings specify technical details for housing unit building sections, including roof modifications such as installing new metal coping, scuppers, roof hatches, and guardrails, as well as reinstalling existing mechanical units and exhaust fans on new raised curbs.

The technical specifications include replacing the existing roof with an 80-mil, fully-adhered (Class A, UL 790) PVC roofing system over protection board and rigid insulation. The project involves work on existing metal deck with concrete fill and precast concrete planks. The drawings have received approval from the Office of the State Fire Marshal on 10/10/23, with a final approval date of 11/20/2023. The project drawing set is part of the design services and standards branch documentation, with the sheet number AA601 indicating a specific section of the overall project documentation.

View the file

Other files

File Type Posted
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_14.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_30.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_36.pdf PDF
I-001104_-_21-040_-_002_-_Roof_Penetrations.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_10.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_37.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_9.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_13.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_32.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_48.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_26.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_21.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_51.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_6.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_31.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_25.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_38.pdf PDF
21-039_LAC_Replace_Roofs_Volume_1.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_34.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_27.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_40.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_7.pdf PDF
21-039_LAC_Replace_Roofs_Volume_2.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_23.pdf PDF
12_-_FPCM-LAC-I001104-M035-RS.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_47.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_42.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_33.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_16.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_3.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_20.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_18.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_46.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_39.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_35.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_22.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_5.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_24.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_28.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_43.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_15.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_50.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_4.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_19.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_49.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_8.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_29.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_17.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_41.pdf PDF
21-040-LAC_Replace-Roofs-Phase1_Final-Drawings_45.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0'-0"

T.O. 1ST FLR

18'-6"

T.O. (E) PRECAST

CONCRETE WALL

TYP.

AB C D E F G H J K L M K.7 G.4 E.7 B.3

115.7 6 7 7.3 8 9 10 4 2 1.8 1 3 5

/2

/2

0'-0"

T.O. 1ST FLR

18'-6"

T.O. (E) PRECAST

CONCRETE WALL

21'-6"

T.O. (E) PRECAST PANEL

TYP.

TYP.

03 0807

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

HOUSING UNIT BUILDING SECTION

SCALE: 1/8" = 1'-0"

HOUSING UNIT BUILDING SECTION

SCALE: 1/8" = 1'-0"

AA601

H

O U

S

IN

G U

N

IT

T Y

P

IC

A L

B U

IL

D

IN

G

S E

C T

IO

N

S

SHEET NUMBER

S T A T E O

F C

A

LI

F O

R N

IA

D

E P A R

T M

E N

T O

F C

O R

R E C

T

IO

N S A

N D

R E H

A B

IL

IT

A T

IO

N F A C

IL

IT

Y P

LA

N

N

IN

G , C

O N

S T R

U C

T

IO

N A

N D M

A N

A G

E M

E N

T D

IV

IS

IO

N

D

ES

IG

N

S

ER

VI

C

ES

A

N D S

TA

N

D

AR

D S

BR

AN

C H

D E S

IG

N S

ER

VI

C

ES

S

EC

TI

O

N

APPROVAL

L A C

V1

C A L

IF

O R N

IA

S

T A T E P

R

IS

O N L O

S A

N G

E L E S C

O U

N T Y

T H

S T R

E E T , W

E S T

L A N

C A S T E R C

A

R E P L A C E R

O O

F S

P H

A S E

A U

G U

S T

F

IN

A L D

R A W

IN

G

S

.1

BUILDING SECTION KEYNOTES

(N) METAL COPING AT PARAPET, SEE DETAIL

(E) EXHAUST FAN, REINSTALLED OVER NEW RAISED CURB, SMD.

(N) CRICKET

A-900

(N) PRIMARY SCUPPER AT LOWER ROOF

(N) ROOF HATCH, SEE DETAIL

(N) GUARDRAIL, SEE DETAIL

(E) MECHANICAL UNIT RE-INSTALLED OVER (N) RAISED CURB. SMD.

(N) 80 MIL, FULLY-ADHERED (CLASS A, UL 790) PVC ROOFING SYSTEM

OVER 1/2" PROTECTION BOARD OVER 6" MIN RIGID INSULATION.

(E) METAL DECK WITH CONCRETE FILL.

10 (E) PRECAST CONCRETE PLANK W/ CONCRETE TOPPING.

A901 TYP.

A-902

A-900

A900

A900

A902

A901

11 (E) STAIR CAGE TO BE REINSTALLED.

A901

A906

A906

SIM.

V1

OFFICE OF THE STATE FIRE MARSHAL

shall be available on the project site at all times.

10/10/23

APPROVED FIRE AND PANIC ONLY

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans

23-0002

11/20/2023 CASp 491 #1317

File details come from the government source that posted it. Updated .