07 71 23 - Manufactured Gutters and Downspouts.pdf

PDF 477 KB Posted

Attached to
West Pump Station Replacement Project
Solicitation number
Not on record
Issued by
Chester County, Pennsylvania

About this file

This is a technical specification document for manufactured gutters and downspouts prepared by Herbert, Rowland & Grubic, Inc., in relation to the West Pump Station Replacement Project being conducted by the Northwestern Chester County Municipal Authority in Pennsylvania. The specification establishes requirements for gutter and downspout materials, design, fabrication, and installation for the project. Materials specified include prefinished galvanized-steel sheet with either silicone-modified polyester or PVDF coating, manufactured in rectangular or square profiles per NRCA standards, with 24-gauge core steel thickness and G90 zinc coating. The gutters and downspouts must be sized in accordance with the NRCA Roofing Manual based on rainfall intensity for a 100-year storm event. Fabrication requirements mandate square and accurate sizing, maximum possible lengths, connection pieces, hemmed exposed edges, and either polyester or PVDF coating systems compliant with AAMA standards. Installers must possess a minimum of three years of experience in fabricating and installing similar sheet metal systems, and installation must include formed seams, watertight joints, proper flashing to accessories, and a minimum gutter slope of one-quarter inch per ten feet.

The specification requires suppliers to submit manufacturer product data and shop drawings indicating locations, configurations, jointing methods, fastening methods, and installation details prior to fabrication. Materials must be delivered in manufacturer's original packaging, stored in clean and dry conditions per manufacturer instructions, and protected from moisture, dust, and damage. All fasteners and anchoring devices must match the gutter and downspout material and finish, with zinc-molybdate primer or manufacturer-recommended coating required for contact with dissimilar metals. Concealed metal surfaces must be painted with protective backing paint to a minimum dry film thickness of fifteen mils. Field measurements must be verified prior to fabrication to ensure proper fit and performance. Splash pads must be installed under downspouts and secured in place to complete the system installation.

View the file

Other files

File Type Posted
40 05 53 - Identification For Process Piping.pdf PDF
44 42 56 - Base Mounted Pumping System.pdf PDF
32 31 13 - chain link fences and gates.pdf PDF
32 05 13 - Soils For Exterior Improvements.pdf PDF
00 73 73 - Statutory Requirements.pdf PDF
01 78 39 - Project Record Documents.pdf PDF
00 73 46 - Wage Determination Schedule Cover.pdf PDF
40 05 19 - Ductile Iron Process Pipe.pdf PDF
04 05 13 - Masonry Mortaring.pdf PDF
31 23 23.33 - Flowable Fill.pdf PDF
00 45 19 Non Collusion Affidavit.pdf PDF
07 31 13 - asphalt shingles.pdf PDF
00 65 16 - Certificate of Substantial Completion.pdf PDF
01 57 28 - Temporary Flow Control.pdf PDF
26 27 16 - Electrical Panels & Enclosures.pdf PDF
01 31 19 - Project Meetings.pdf PDF
01 33 00 - Submittal Procedures.pdf PDF
01 32 16 - Construction Progress Schedule - SMALL.pdf PDF
00 63 49 - Work Change Directive Form.pdf PDF
40 66 16 - Firewall Hardware.pdf PDF
33 31 11 - Public Sanitary Sewerage Gravity Piping.pdf PDF
04 20 00 - Unit Masonry.pdf PDF
01 77 00 - Closeout Procedures.pdf PDF
32 91 19 - Landscape Grading.pdf PDF
41 22 23.19 - Monorail Electric Chain Hoists with Manual Geared Trolley.pdf PDF
00 41 16.b - Bid Frm for Const Contract 2018 - EC.pdf PDF
26 05 26 - Grounding.pdf PDF
01 29 00 - Payment Procedures.pdf PDF
40 05 78.29 - Combination Air Valves For Wastewater Service.pdf PDF
01 40 00 - Quality Requirements.pdf PDF
00 65 19.19 - Consent of Surety to Final Payment.pdf PDF
00 45 46 Public Works Employment Verification Form.pdf PDF
40 05 61 - Gate Valves.pdf PDF
31 05 16 - aggregates for earthwork.pdf PDF
09 91 00 Painting.pdf PDF
08 13 13 - Standard Hollow Metal Doors.pdf PDF
00 61 13.13 - Performance Bond.pdf PDF
40 05 51 - Common Requirements For Process Valves..pdf PDF
00 73 43-1 - Certification Form llc-25 PA Dep L&I.pdf PDF
01 74 19 - Construction Waste Management and Disposal.pdf PDF
34 71 13 - Vehicle Barriers.pdf PDF
04 01 20 - Masonry Cleaning.pdf PDF
00 73 36 - Equal Employment Opportunity Requirements.pdf PDF
00 21 13 - Instructions to Bidders.pdf PDF
00 61 13.16 - Payment Bond.pdf PDF
00 11 13 - Advertisement for Bids.pdf PDF
08 90 00 - LOUVERS AND VENTS.pdf PDF
40 05 63 - Ball Valves.pdf PDF
26 05 00 - Electrical General.pdf PDF
46 24 23 - Channel Sewage Grinders.pdf PDF
Show 40 more

Latest 50 of 171 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

07 71 23 – MANUFACTURED GUTTERS AND DOWNSPOUTS

Herbert, Rowland & Grubic, Inc. 07 71 23 - 1 000483.0450

SECTION 07 71 23 – MANUFACTURED GUTTERS AND DOWNSPOUTS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Gutters and downspouts.

1.2 DEFINITIONS

A. PVDF: Polyvinylidene fluoride.

1.3 REFERENCE STANDARDS

A. American Architectural Manufacturers Association:

1. AAMA 611 - Voluntary Specification for Anodized Architectural Aluminum.

2. AAMA 2603 - Voluntary Specification, Performance Requirements and Test

Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels.

3. AAMA 2604 - Voluntary Specification, Performance Requirements and Test

Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels.

4. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels.

B. ASTM International:

1. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated

(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.

C. National Roofing Contractors Association:

1. NRCA - The NRCA Roofing Manual.

D. Sheet Metal and Air Conditioning Contractors:

1. SMACNA - Architectural Sheet Metal Manual.

1.4 COORDINATION

A. Section 01 31 13 – Project Coordination: Requirements for coordination.

B. Coordinate Work of this Section with roof edge construction.

C. Coordinate with roof membrane warranty requirements.

1.5 SUBMITTALS

A. Section 01 33 00 – Submittal Procedures: Requirements for submittals.

B. Product Data: Submit manufacturer information regarding components, materials, and

Herbert, Rowland & Grubic, Inc. 07 71 23 - 2 000483.0450 finishes.

C. Shop Drawings: Indicate locations, configurations, jointing methods, fastening methods, locations, and installation details.

1.6 QUALITY ASSURANCE

A. Perform Work according to NRCA Roofing Manual.

B. Installer shall have a minimum of 3 years of experience in fabricating and installing similar sheet metal systems.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Section 01 61 00 – Product Requirements: Requirements for transporting, handling, storing, and protecting products.

B. Inspection: Accept materials on Site in manufacturer's original packaging and inspect for damage.

C. Storage:

1. Store materials according to manufacturer instructions.

2. Prevent contact with materials capable of causing discoloration, staining, or damage.

3. Slope to drain.

D. Protection:

1. Protect materials from moisture and dust by storing in clean, dry location remote from construction operations areas.

2. Stack material to prevent twisting, bending, and abrasion, and to provide ventilation.

3. Provide additional protection according to manufacturer instructions.

1.8 EXISTING CONDITIONS

A. Field Measurements:

1. Verify field measurements prior to fabrication.

PART 2 - PRODUCTS

2.1 PERFORMANCE AND DESIGN CRITERIA

A. Sizing: Comply with NRCA Roofing Manual for sizing components based on rainfall intensity determined by storm occurrence of once in 100 years.

2.2 GUTTERS AND DOWNSPOUTS

A. Description:

1. Gutters:

Herbert, Rowland & Grubic, Inc. 07 71 23 - 3 000483.0450

a. Material: Sheet metal.

b. Profile: NRCA; rectangular or square.

2. Downspouts:

a. Material: Same metal type as gutters.

b. Profile: NRCA; rectangular or square.

2.3 MATERIALS

A. Prefinished Galvanized-Steel Sheet:

1. Comply with ASTM A653/A653M; G90 zinc coating.

2. Core Steel Thickness: 24 gage.

3. Shop Precoat: Silicone-modified polyester or PVDF.

4. Color: As selected by Owner.

2.4 FABRICATION

A. Forming of Sections:

1. Description:

a. Square and accurate in size.

b. Maximum possible lengths.

c. Free of distortion or defects detrimental to appearance or performance.

2. Shapes: As indicated on Drawings.

B. Fabricate with required connection pieces.

C. Hem exposed edges of metal.

D. Polyester Coating:

1. Description: Baked-enamel system.

2. Material: Modified silicone.

3. Comply with AAMA 2603.

OR

E. PVDF Coating:

1. Description: Multiple-coat, thermally cured, fluoropolymer system.

2. Comply with AAMA 2604.

F. Primer Coat: Finish concealed side of metal sheets with primer compatible with finish system, as recommended by finish system manufacturer.

G. Site Finishing: As specified in Section 09 91 00 – Painting.

2.5 ACCESSORIES

A. Anchors and Supports:

1. Profile: To suit gutters and downspouts.

2. Anchoring Devices: Type as recommended by manufacturer.

3. Supports:

Herbert, Rowland & Grubic, Inc. 07 71 23 - 4 000483.0450

a. Gutters: Furnish brackets, straps.

b. Downspouts: Furnish brackets and straps.

B. Fasteners: Same material and finish as gutters and downspouts.

C. Primer Type: Zinc molybdate or manufacturer recommended coating when in contact with dissimilar metals.

D. Protective Backing Paint: Zinc-molybdate alkyd or manufacturer recommended coating when in contact with dissimilar metals.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Section 01 73 00 – Execution Requirements: Requirements for installation examination.

B. Verify that surfaces are ready to receive gutters and downspouts.

3.2 PREPARATION

A. Section 01 73 00 – Execution Requirements: Requirements for installation preparation.

B. Paint concealed metal surfaces and surfaces in contact with dissimilar metals using protective backing paint to minimum dry film thickness of 15 mils.

3.3 INSTALLATION

A. Sheet Metal:

1. Join lengths with formed seams, watertight.

2. Flash and seal gutters to downspouts and accessories.

B. Minimum Gutter Slope: 1/4 inch per 10 foot.

C. Set splash pads under downspouts, and secure in place.

END OF SECTION 07 71 23