67-REV 1.19.26 16140 Wiring Devices.pdf
PDF 100 KB Posted
- Attached to
- Route 54 Sanitary Sewer Extension Project
- Solicitation number
- Not on record
- Issued by
- Lycoming County, Pennsylvania
About this file
This is a Section 16140 Wiring Devices specification document prepared by the West Branch Regional Authority for the Route 54 Sanitary Sewer Extension Project (Contract No. WB-1) in Clinton Township, Lycoming County, Pennsylvania. The specification outlines requirements for wiring devices including standard duplex receptacles rated at 20 amperes and 125 volts, Ground Fault Current Interrupter (GFCI) duplex convenience receptacles, device plates, and box covers. The broader project consists of approximately 1,520 linear feet of gravity sanitary sewer, 11 manholes, 13 lateral connections, one duplex sewage pumping station, 404 linear feet of force main, and one stream crossing. Sealed bids for the overall project are due by 1:00 PM prevailing time on Monday, February 16, 2026, with bids to be received and opened online at http://pennbid.net/. Prospective bidders are required to register as plan holders on the PennBid website, which will be updated with addenda and relevant project information. Project documentation, including bid documents, is available exclusively through PennBid.
The wiring devices specification requires that all receptacles and devices be UL approved and comply with Federal Specifications, NEMA standards, and Underwriters' Laboratories standards. Specific product requirements include Pass and Seymour model 5362 for standard convenience receptacles and model 2091 for GFCI receptacles, with white receptacles specified for light wall finishes and brown for wood or dark finishes. Installation requirements specify that receptacles be mounted vertically 18 inches above finished floor with grounding poles on top, with weatherproof "while-in-use" type covers provided where indicated. Each bid must be accompanied by a bid bond or certified check equal to 10 percent of the total bid amount as security for proper execution. Work on the contract is subject to Pennsylvania Department of Labor and Industry prevailing wage rate requirements, and the contractor must comply with the Pennsylvania Steel Products Procurement Act of 1978.
View the file
Other files
Show 40 more
Latest 50 of 75 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 16140
WIRING DEVICES DIVISION 16
West Branch Regional Authority 16140-1 January 2026 Route 54 Sanitary Sewer Extension Project Wiring Devices Contract No. WB-1
PART 1 - GENERAL
1.01 WORK INCLUDED
A. Receptacles.
B. Special Purpose Outlets.
C. Device Plates and Box Covers.
1.02 RELATED WORK
A. Section 16130: Boxes: Outlet boxes.
B. Section 16161: Grounding: Grounding the work of the Section.
1.03 REFERENCE STANDARDS
A. Federal Specifications (FS)
1. FS W-C-596: Electrical Power Connector, Plug, Receptacle, and Cable Outlet
2. FS W-S-896: Switch, Toggle.
B. National Electrical Manufacturer's Association (NEMA)
1. NEMA WD 1: General-Purpose Wiring Devices.
2. NEMA WD 5: Specific-Purpose Wiring Devices.
C. Underwriters' Laboratories, Inc. (UL)
1. UL Applicable Publications.
1.04 REGULATORY REQUIREMENTS
A. Provide UL approved devices.
1.05 SUBMITTALS
A. Product Data: Submit in accordance with Section 01340: Shop Drawings, Product Data and Samples.
B. Provide product data showing configurations, finishes, dimensions, and manufacturer's instructions.
PART 2 - PRODUCTS
2.01 RECEPTACLES
SECTION 16140
WIRING DEVICES DIVISION 16
West Branch Regional Authority 16140-2 January 2026 Route 54 Sanitary Sewer Extension Project Wiring Devices Contract No. WB-1
A. Convenience - Standard Duplex: Parallel blade, U-grounding slot, specification grade, rated at 20 amperes, 125 volts, designed for split feed service, Pass and Seymour, 5362.
B. Ground Fault Current Interrupter (GFCI): Duplex convenience, parallel blade, U-grounding slot, specification grade rated at 20 amperes, 125 volts, Pass & Seymour 2091.
C. Color: Provide white receptacles in areas with light wall finish. Provide brown receptacles in areas with wood or dark wall finish.
D. Provide single power receptacles of the voltage, ampacity rating and NEMA configurations as noted on Drawings.
2.02 PLATE COVERS
A. Where device is indicated as being weatherproof, “while-in-use” type covers shall be provided on the outlet box. Covers shall be manufactured by Cooper Wiring Devices or approved equal.
PART 3 - EXECUTION
3.01 RECEPTACLE INSTALLATION
A. Mount receptacles vertically 18 inches above finished floor to the center of the device, except as noted on the Drawings, with grounding pole on top.
3.02 SPECIAL PURPOSE OUTLET INSTALLATION
A. Coordinate mounting with other outlets.
B. Provide appropriate outlet boxes and cover plates as required.
3.03 COVER PLATE INSTALLATION
A. Install cover plates on all wiring devices.
B. Install decorative plates on switch, receptacle, and blank outlets in finished areas.
C. Install devices and wall plates flush and level.