About this file
This document is an exhibit detailing the existing roof structure and proposed structural alterations for the Houlton Land Port of Entry Facilities Repair and Alterations project. The exhibit shows the existing roof framing plan and indicates that the project will involve reviewing the existing beams to support the weight of a new stair and proposed rooftop mechanical equipment. It also shows that a new mechanical screen will be installed on the roof, requiring an assessment of the existing structure's capacity to support it. The document is part of a larger federal contract opportunity solicitation for Construction Manager as Constructor (CMc) / Construction Manager as Risk (CMAR) services for this project, which has an estimated construction value between $22-32 million. The solicitation sets forth requirements for technical and price proposals, with a proposal due date of November 11, 2024.
View the file
Other files
Show 40 more
Latest 50 of 108 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
swinslow Text Box
EXHIBIT E.1
Silman Structural
Solutions
EC-300
EC-300
EC-500
EC-501
LPOE HOULTON [31084]
2024-07-19 | CONCEPT DEVELOPMENT
MPB EXISTING ROOF STRUCTURE
5' -7
4'
-3
4' -3
5'
-4
5' -4
0'-11"7'-9"
5'-3 1/4"
5'-3 1/4"
5'-3 1/4"
5'-3 1/4"
W16x31
W16x31
W16x31
W16x40
W16x40
W16x31
W16x31
W16x31
W16x31
W x3
W x3
W x3
W x3
W16x31
W x3
W x3
5" CONC SLAB ON 1.5"
METAL DECK (TYP.)
PAGE 1/2
Silman Structural
Solutions
LPOE HOULTON [31084]
2024-07-19 | CONCEPT DEVELOPMENT
MPB PROPOSED ROOF STRUCTURAL ALTERATIONS
T
T
T
T
TT
T T
T
T
T
T
T T T
T
T
T
T
DN
A-355
A-310
A-310
A-351.1
A-351.2
A-351.2
5' -7
4'
-3
4' -3
5'
-4
5' -4
0'-11"
7'-9"
5'-3 1/4"
5'-3 1/4"
5'-3 1/4"
5'-3 1/4"
W16x31
W16x31
W16x31
W16x40
W16x40
W16x31
W16x31
W16x31
W16x31
W x3
W x3
W x3
W x3
W16x31
W x3
W x3
EXISTING ELEVATOR
OPENING
REVIEW EXISTING BEAMS
FOR WEIGHT OF NEW
STAIR, REINFORCE AS
NECESSARY
NEW STAIR OPENING
PROPOSED ROOFTOP
MECHANICAL EQUIPMENT
(LOCATION AND WEIGHT
TO BE FINALIZED).
SUPPORT ON STEEL
DUNNAGE. BEAMS
BELOW TO BE REVIEWED
FOR NEED TO
REINFORCE
HIGHLIGHT INDICATES TENTATIVE
EXTENT OF PROPOSED ROOFTOP
MECHANICAL SCREEN. SCREEN POSTS
WILL BE HOT ROLLED STEEL FASTENED
TO ROOF STRUCTURE AND BRACED
WITH 45-DEGREE HOT ROLLED STEEL
KNEE BRACES. EXISTING STRUCTURE
UNDER FINAL SCREEN LOCATION WILL
BE ASSESSED FOR CAPACITY TO
SUPPORT SCREEN
C 5x
C 5x
C 5x
C 5x
NEW 16"x16" MEP OPENINGNEW 16"x16" MEP
OPENING
PAGE 2/2