NEW HAMPSHIRE AIR NATIONAL GUARD HEADQUARTERS 157
TH
REFUELING WING
PEASE AIR NATIONAL GUARD BASE, NEW HAMPSHIRE
KC-46A ADAL MAINTENANCE HANGAR, BUILDING 254 TYPE B3 SUBMISSION PROJECT NO. SZCQ139904
DOOR HARDWARE 08 71 00 - 1
SECTION 087100 - DOOR HARDWARE (08/08)
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage
Through Exterior Windows, Curtain Walls, and Doors Under
Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2006) Butts and Hinges
ANSI/BHMA A156.13 (2012) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.16 (2008) Auxiliary Hardware
ANSI/BHMA A156.18 (2006) Materials and Finishes
ANSI/BHMA A156.21 (2009) Thresholds
ANSI/BHMA A156.3 (2008) Exit Devices
ANSI/BHMA A156.5 (2010) Auxiliary Locks and Associated Products
ANSI/BHMA A156.6 (2010) Architectural Door Trim
ANSI/BHMA A156.7 (2003; R 2009) Template Hinge Dimensions
ANSI/BHMA A156.8 (2010) Door Controls - Overhead Stops and Holders
BHMA A156.15 (2011) Release Devices Closer Holder, Electromagnetic and
Electromechanical
BHMA A156.22 (2011) Door Gasketing and Edge Seal Systems
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2012; Amendment 1 2012) Life Safety Code
NFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening
Protectives
REFUELING WING
DOOR HARDWARE 08 71 00 - 2
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard
Steel Doors and Frames
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (2012) Building Materials Directory
1.2 SUBMITTALS
Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES.
SD-02 Shop Drawings
Hardware schedule
Keying system
SD-03 Product Data
Hardware items
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule items, Data Package 1
Submit data package in accordance with Section 01 78 23 OPERATION AND
MAINTENANCE DATA.
SD-11 Closeout Submittals
Key Bitting
1.3 HARDWARE SCHEDULE
Prepare and submit hardware schedule in the following form:
REFUELING WING
DOOR HARDWARE 08 71 00 - 3
Hardware
Item
Quantity Size Reference
Publi-cation Type
No.
Finish Mfr Name and
Catalog
No.
Key
Control
Symbols
UL Mark
(If fire rated and listed)
BHMA Finish
Desig-nation
1.4 KEY BITTING CHART REQUIREMENTS
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (AA1, AA2, etc.).
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.5 QUALITY ASSURANCE
1.5.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.5.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the
Contracting Officer, Contractor, Door Hardware subcontractor, using Activity and Base Locksmith shall meet to discuss key requirements for the facility.
1.6 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown in hardware schedule. Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
1.7 LEED REQUIREMENT
Credit MR 4: Product data and certification letter from manufacturer or vendor indicating percentages by weight of post-consumer and pre-consumer recycled content for products having recycled content. Include statement indicating costs for each product having recycled content.
REFUELING WING
DOOR HARDWARE 08 71 00 - 4
Credit MR 5: Product data for regional materials indicating location and distance from Project of material manufacturer and point of extraction, harvest, or recovery for each raw material.
Include statement indicating cost for each regional material and the fraction by weight that is considered regional.
Credit IEQ 4.2: Product data for paints and coatings used inside the weatherproofing system indicating
VOC content of each product used.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Provide hardware to be applied to metal manufactured to template. Promptly furnish template information or templates to door and frame manufacturers. Conform to ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 80 for fire doors and NFPA 101 for exit doors, as well as to other requirements indicated, even if such hardware is not specifically mentioned under paragraph entitled "Hardware Schedule." Provide the label of Underwriters
Laboratories, Inc. for such hardware listed in UL Bld Mat Dir or labeled and listed by another testing laboratory acceptable to the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark will be visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.
2.3.1 Hinges
ANSI/BHMA A156.1, 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for exterior doors and reverse-bevel interior doors so that pins will be nonremovable when door is closed.
Other antifriction bearing hinges may be provided in lieu of ball-bearing hinges.
a. Quantity: Provide the following hinge quantity, unless otherwise indicated:
Two Hinges: For doors with heights up to 60 inches.
Three Hinges: For doors with heights 61 to 90 inches.
Four Hinges: For doors with heights 91 to 120 inches.
For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge for every 30 inches of door height greater than 120 inches.
b. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required:
Widths up to 3'0": 4-1/2" standard or heavy weight as specified.
Sizes from 3'1" to 4'0": 5" standard or heavy weight as specified.
c. Hinge Weight and Base Material: Unless otherwise indicated, provide the following:
REFUELING WING
DOOR HARDWARE 08 71 00 - 5
Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate standard weight.
Interior Doors: Standard weight, steel, ball bearing or oil impregnated bearing hinges unless
Hardware Sets indicate heavy weight.
Tornado Resistant Assemblies: At a minimum, provide heavy weight hinges with stainless steel screws used in accordance with and specified as part of a Severe Storm Shelter
Opening meeting ICC 500 and FEMA 361.
d. Hinge Options: Comply with the following where indicated in the Hardware Sets or on Drawings:
Non-removable Pins: Provide set screw in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin while door is closed; for the following applications:
a) Out-swinging exterior doors.
b) Out-swinging access controlled doors.
c) Out-swinging lockable doors.
2.3.2 Door Operating Trim
Flush Bolts and Surface Bolts: ANSI/BHMA A156.3 and A156.16, Grade 1 certified automatic, self-latching, and manual flush bolts and surface bolts. Manual flush bolts to be furnished with top rod of sufficient length to allow bolt location approximately six feet from the floor. Furnish dust proof strikes for bottom bolts. Surface bolts to be minimum 8" in length and UL listed for labeled fire doors and UL listed for windstorm components where applicable. Provide related accessories (mounting brackets, strikes, coordinators, etc.) as required for appropriate installation and operation.
Door Push Plates and Pulls: ANSI/BHMA A156.6 certified door pushes and pulls of type and design specified below or in the Hardware Sets. Coordinate and provide proper width and height as required where conflicting hardware dictates.
a. Push/Pull Plates: Minimum .050 inch thick, size as indicated in Hardware Sets, with square corners and beveled edges, secured with exposed screws unless otherwise indicated.
b. Door Pull and Push Bar Design: Size, shape and material as indicated in the Hardware Sets.
Minimum clearance of 2-1/2 inches from face of door unless otherwise indicated.
c. Offset Pull Design: Size, shape and material as indicated in the Hardware Sets. Minimum clearance of 2-1/2 inches from face of door and offset of 90 degrees unless otherwise indicated.
2.3.3 Locks and Latches
2.3.3.1 Mortise Locks and Latches
ANSI/BHMA A156.13, Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to suit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Install levers and roses of mortise locks with screwless shanks and no exposed screws.
2.3.3.2 Bored Locks and Latches
ANSI/BHMA A156.2, Series 4000, Grade 1.2.3.4.6 Auxiliary Locks
ANSI/BHMA A156.5, Grade 1.
REFUELING WING
DOOR HARDWARE 08 71 00 - 6
2.3.4 Exit Devices
ANSI/BHMA A156.3, Grade 1. Provide adjustable strikes for rim type and vertical rod devices.
Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms.
2.3.5 Exit Locks With Alarm
ANSI/BHMA A156.5, Type E0431 (with full-width horizontal actuating bar) for single doors; Type
E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified. Provide terminals for connection to remote indicating panel. Provide outside control key.
2.3.6 Cylinders and Keying
Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Cylinder cores shall be Stanley Security Solutions / BEST Access - Best Peaks, 150
Series 7 pin with KABA patented key cut to be compatible with the base’s existing master keying system. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.
a. Cylinders: Original manufacturer cylinders complying with the following
1. Mortise Type: Threaded cylinders with rings and straight- or clover-type cam.
2. Rim Type: Cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring.
3. Bored-Lock Type: Cylinders with tailpieces to suit locks.
4. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush and be free spinning with matching finishes.
5. Keyway: Match Facility Standard
b. Keying System: Each type of lock and cylinders to be factory keyed. Conduct specified "Keying
Conference" to define and document keying system instructions and requirements. Keying system shall be coordinated with the Contracting Officer. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key control number as directed by Owner. Incorporate decisions made in keying conference, and as follows:
1. Master Key System: Cylinders are operated by a change key and a master key.
2. Grand Master Key System: Cylinders are operated by a change key, a master key, and a grand master key.
3. Great-Grand Master Key System: Cylinders are operated by a change key, a master key, a grand master key, and a great-grand master key.
4. Existing System: Master key or grand master key locks to Owner's existing system.
5. Keyed alike: Key all cylinders to same change key.
c. Key Quantity: Provide the following minimum number of keys:
1. Top Master Key: One (1)
2. Change Keys per Cylinder: Two (2)
3. Master Keys (per Master Key Group): Two (2)
4. Grand Master Keys (per Grand Master Key Group): Two (2)
5. Construction Keys (where required): Two (2)
6. Construction Control Keys (where required): Two (2)
REFUELING WING
DOOR HARDWARE 08 71 00 - 7
7. Permanent Control Keys (where required): Two (2)
d. Construction Keying: Provide construction master keyed cylinders or temporary keyed construction cores where specified. Provide construction master keys in quantity as required by project
Contractor. Replace construction cores with permanent cores. Furnish permanent cores for installation as directed under specified "Keying Conference."
e. Key Registration List: Provide keying transcript list to Owner's representative in the proper format for importing into key control software.
2.3.7 Lock Trim
Cast, forged, or heavy wrought construction and commercial plain design.
2.3.7.1 Lever Handles
Conform to the minimum requirements of ANSI/BHMA A156.13 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in
ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
Locksets to be manufactured with a corrosion resistant, stamped 12 gauge minimum formed steel case and be field-reversible for handing without disassembly of the lock body. Lockset trim (including knobs, levers, escutcheons, roses) to be the product of a single manufacturer. Furnish with standard 2-3/4" backset, 3/4" throw anti-friction stainless steel latchbolt, and a full 1" throw stainless steel bolt for deadbolt functions.
a. Multi-Point Locksets, Security: Three-point locking system device engineered for in-swinging door applications on windstorm safe shelter rooms. Extra heavy duty steel component construction securing the door to the frame at top, bottom and center latch positions. All three latching points are automatically activated when the device is locked.
1. Severe Storm Shelter Components: Multi-point locking system devices engineered for in-swinging and out-swinging door applications on tornado or hurricane resistant safe shelter rooms. The multi-point latching integrated device is approved for usage as part of a complete ICC 500 (2008) and FEMA 361 door, frame and hardware assembly.
2.3.8 Lock and Latch Strikes
Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated, and as follows:
a. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by manufacturer.
b. Extra-Long-Lip Strikes: For locks used on frames with applied wood casing trim.
c. Aluminum-Frame Strike Box: Provide manufacturer's special strike box fabricated for aluminum framing.
Standards: Comply with the following:
a. Strikes for Mortise Locks and Latches: BHMA A156.13.
b. Strikes for Bored Locks and Latches: BHMA A156.2.
REFUELING WING
DOOR HARDWARE 08 71 00 - 8
c. Strikes for Auxiliary Deadlocks: BHMA A156.5.
d. Dustproof Strikes: BHMA A156.16.
2.3.9 Conventional Exit Devices
2.3.9.1 General Requirements
All exit devices specified herein shall meet or exceed the following criteria:
a. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL 305. Provide proper fasteners as required by manufacturer including sex nuts and bolts at openings specified in the Hardware Sets.
b. Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware." Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer's catalog and template book for specific requirements.
1. Fire Exit Removable Mullions: Provide keyed removable mullions for use with fire exit devices complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire and panic protection, based on testing according to UL 305 and NFPA 252. Mullions to be used only with exit devices for which they have been tested.
c. Except on fire rated doors, provide exit devices with hex key dogging device to hold the pushbar and latch in a retracted position. Provide optional keyed cylinder dogging on devices where specified in Hardware Sets.
d. Flush End Caps: Provide heavy weight impact resistant flush end caps made of architectural metal in the same finish as the devices as in the Hardware Sets. Plastic end caps will not be acceptable.
e. Lever Operating Trim: Where exit devices require lever trim, furnish manufacturer's heavy duty trim with cold forged escutcheons, beveled edges, and four threaded studs for thru-bolts.
1. Lock Trim Design: As indicated on Hardware Sets, provide finishes and designs to match that of the specified locksets. Provide free-wheeling type trim where indicated.
2. Where function of exit device requires a cylinder, provide an interchangeable core type keyed cylinder (Rim or Mortise) as specified in Hardware Sets.
f. Vertical Rod Exit Devices: Provide and install interior surface and concealed vertical rod exit devices at Less Bottom Rod (LBR) unless otherwise indicated.
g. Narrow Stile Applications: At doors constructed with narrow stiles, or as specified in Hardware
Sets, provide devices designed for maximum 2" wide stiles.
h. Dummy Push Bar: Nonfunctioning push bar matching functional push bar.
i. Rail Sizing: Provide exit device rails factory sized for proper door width application.
j. Thru Bolt Installation: For exit devices and trim as indicated in Door Hardware Sets.
2.3.9.2 Conventional Push Rail Exit Devices (Heavy Duty)
ANSI/BHMA A156.3, Grade 1 certified panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets. Mounting rails to be formed from smooth stainless steel, brass or bronze architectural materials no less than 0.072" thick, with push rails a minimum of 0.062" thickness.
Painted or aluminum metal rails are not acceptable. Exit device latch to be investment cast stainless steel, pullman type, with deadlock feature.
2.3.9.3 Tube Steel Removable Mullions
REFUELING WING
DOOR HARDWARE 08 71 00 - 9
ANSI/BHMA A156.3 removable steel mullions with malleable-iron top and bottom retainers and a primed paint finish. Provide keyed removable feature, stabilizers, and mounting brackets as specified in the Hardware Sets. At openings designed for severe wind load conditions due to hurricanes or tornadoes, provide manufacturers approved mullion and accessories to meet applicable state and local windstorm codes.
2.3.10 Door Closers
Door closers to be from one manufacturer, matching in design and style, with the same type door preparations and templates regardless of application or spring size. Closers to be non-handed with full sized covers including installation and adjusting information on inside cover. Closers to comply with
UL-10C and UBC 7-2 for Positive Pressure Fire Test and be UL listed for use of fire rated doors.
Provide closers which have surpassed 10 million cycles in a test witnessed and verified by UL. Provide manufacturer's 10-year warranty. Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Where closers are indicated for doors required to be accessible to the physically handicapped, provide units complying with ANSI ICC/A117.1.
2.3.10.1 Closer Arms
Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets.
a. Where closers are indicated to have mechanical dead-stop, provide heavy duty arms and brackets with an integral positive stop.
b. Where closers are indicated to have mechanical hold open, provide heavy duty units with an additional built-in mechanical holder assembly designed to hold open against normal wind and traffic conditions. Holder to be manually selectable to on-off positions.
c. Where closers are indicated to have a cushion-type stop, provide heavy duty arms and brackets with spring stop mechanism to cushion door when opened to maximum degree.
d. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics. Provide drop plates or other accessories as required for proper mounting.
2.3.10.2 Closer Accessories
Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates, and thru-bolt or security type fasteners as specified in the door Hardware Sets.
2.3.10.3 Door Closers, Surface Mounted (Heavy Duty)
ANSI/BHMA A156.4, Grade 1 surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 through 6; and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control. Provide non-handed units standard.
2.3.10.4 Identification Marking
REFUELING WING
DOOR HARDWARE 08 71 00 - 10
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation located to be visible after installation.
2.3.11 Overhead Holder and Stops
ANSI/BHMA A156.8. Door stops and holders to be of type and design as specified in the Hardware
Sets. ANSI/BHMA A156.16, Grade 1 certified door stops and wall bumpers. Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or other types of door stops are specified in Hardware Sets. Do not mount floor stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and holders.
2.3.12 Closer Holder-Release Devices
BHMA A156.15.
2.3.13 Door Protection Plates
ANSI/BHMA A156.6.
2.3.13.1 Sizes of Armor Mop and Kick Plates
2 inch less than door width for single doors; one inch less than door width for pairs of doors. Height as specified in Hardware Sets.
2.3.14 Edge Guards
ANSI/BHMA A156.6, stainless steel, of same height as armor plates.
2.3.15 Door Silencers
ANSI/BHMA A156.16. Silencers Type L03011. Provide three silencers for each single door, two for each pair.
2.3.16 Padlocks
ASTM F883.
2.3.17 Thresholds
ANSI/BHMA A156.21. Thresholds, weatherstripping, and gasket seals to be of type and design as specified or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated..
2.3.18 Weather Stripping Gasketing and Seals
BHMA A156.22. Provide the type and function designation where specified in paragraph entitled
"Hardware Schedule". Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weather stripped doors in accordance with ASTM E283. Provide weather stripping with one of the following:
REFUELING WING
DOOR HARDWARE 08 71 00 - 11
2.3.18.1 Smoke Labeled Gasketing
Assemblies complying with NFPA 105 that are listed and labeled by a testing and inspection agency acceptable to authorities having jurisdiction, for smoke control ratings indicated, based on testing according to UL 1784. Provide smoke labeled perimeter gasketing at all smoke labeled openings.
2.3.18.2 Fire Labeled Gasketing
Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to
UL-10C. Provide intumescent seals as indicated to meet UL 10C Standard for Positive Pressure Fire
Tests of Door Assemblies, and UBC 7-2, Fire Tests of Door Assemblies.
2.3.19 Sound-Rated Gasketing
BHMA A156.22. Include adjustable doorstops at head and jambs and an automatic door bottom per set, both of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed-cell sponge gasket. Furnish door bottoms with adjustable operating rod and silicone rubber or closed-cell sponge neoprene gasket. Doorstops mitered at corners. Provide the type and function designation where specified in paragraph entitled "Hardware Sets".
2.3.20 Rain Drips
Extruded aluminum, not less than 0.08 inch thick, with finish matching door frame. Set drips in sealant and fasten with stainless steel screws.
2.3.20.1 Door Rain Drips
Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.
2.3.20.2 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection, with length equal to overall width of door frame. Align bottom with door frame rabbet.
2.3.21 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of proper type, quality, size, quantity, and finish with hardware. Provide stainless steel or nonferrous metal fasteners that are exposed to weather. Provide fasteners of type necessary to accomplish a permanent installation.
REFUELING WING
DOOR HARDWARE 08 71 00 - 12
2.5 FINISHES
ANSI/BHMA A156.18. Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated by certain manufacturer's for their products.
Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware.
Protect mechanical finishes on exposed surfaces from damage by applying a stippable, temporary protective covering before shipping.
PART 3 EXECUTION
3.1 INSTALLATION
Install hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces. Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weather Stripping Installation
Handle and install weather stripping to prevent damage. Provide full contact, weather-tight seals.
Operate doors without binding.
3.1.2 Sound-Rated Gasketing Installation
Install as specified for stop-applied weather stripping.
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, screws as specified.
3.2 FIRE DOORS AND EXIT DOORS
Install hardware in accordance with NFPA 80 for fire doors, NFPA 101 for exit doors.
3.3 HARDWARE LOCATIONS
SDI/DOOR A250.8, unless indicated or specified otherwise.
a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
REFUELING WING
DOOR HARDWARE 08 71 00 - 13
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Furnish complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the
Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting
Officer. Correct, repair, and finish, as directed, errors in cutting and fitting and damage to adjoining work.
3.6 DOOR HARDWARE SETS
Hardware Group 1 (Doors: 18.0, 19.0, 20.0, 21.0, 22.0, 28.0, 33.0, 36.0, 37.0)
3 Hinge TA2314 4-1/2" x 4-1/2" US32D
MK
1 Office Lock 8205 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer 7500 SN-134 689 NO
1 Wall Stop 409 US32D
RO
3 Silencer 608 RO
Hardware Group 2 (Doors: 12.0, 45.0, 46.0)
3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D
MK
1 Classroom Lock 8237 LNB LC US26D
SA
REFUELING WING
DOOR HARDWARE 08 71 00 - 14
Hardware Group 2 (Doors: 12.0, 45.0, 46.0)
1 Cylinder 1E-74 626 BE
1 Door Closer 7500 SN-134 689 NO
1 Wall Stop 409 US32D
1 Gasketing S773D PE
Hardware Group 3 (Doors: 5.0, 9.0,10.0, 11.0, 14.0, 85.0 )
6 Hinge TA2314 4-1/2" x 4-1/2" US32D
MK
1 Flush Bolt 2842 US26D
RO
1 Dust Proof Strike 570 US26D
RO
1 Classroom Lock 8237 LNB LC US26D
SA
2 Cylinder 1E-74 626 BE
1 Mounting Bracket 2601AB US28
RO
1 Coordinator 2672 US28
RO
2 Door Closer 7500 SN-134 689 NO
2 Wall Stop 409 US32D
REFUELING WING
DOOR HARDWARE 08 71 00 - 15
Hardware Group 3 (Doors: 5.0, 9.0,10.0, 11.0, 14.0, 85.0 )
Hardware Group 4 (Doors: 27.0)
MK
1 Push Plate 70C US32D
RO
1 Pull Plate 107x70C US32D
RO
1 Door Closer 7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
RO
1 Wall Stop 409 US32D
Hardware Group 5 (Doors: 28.0)
3 Hinge TA2314 4-1/2" x 4-1/2: US32D
MK
1 Privacy Set 8265 LNB US26D
SA
1 Door Closer CLP7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
REFUELING WING
DOOR HARDWARE 08 71 00 - 16
Hardware Group 5 (Doors: 28.0)
Hardware Group 6 (Doors: 23.0, 24.0, 25.0)
6 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D
MK
2 Push Plate 70C US32D
RO
2 Pull Plate 107x70C US32D
RO
2 Door Closer CLP7500 SN-134 689 NO
2 Kick Plate K1050>8" US32D
Hardware Group 7 (Doors: 32.0)
MK
1 Classroom Lock 8237 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer CLP7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
REFUELING WING
DOOR HARDWARE 08 71 00 - 17
Hardware Group 7 (Doors: 32.0)
1 Wall Stop 409 US32D
Hardware Group 8 (Doors: 30.0, 31.0, 39.0, 43.0)
6 Hinge TA2314 4-1/2" x 4-1/2" US32D
MK
1 Flush Bolt 2842 US26D
RO
1 Dust Proof Strike 570 US26D
RO
1 Classroom Lock 8237 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Mounting Bracket 2601AB US28
RO
1 Coordinator 2672 US28
RO
2 Door Closer CLP7500 SN-134 689 NO
2 Wall stop 409 US32D
Hardware Group 9 (Doors: 4.0, 6.0, 7.0, 8.0)
3 Hinge TA2314 NRP 4-1/2" x 4-1/2" US32D
MK
REFUELING WING
DOOR HARDWARE 08 71 00 - 18
Hardware Group 9 (Doors: 4.0, 6.0, 7.0, 8.0)
1 Classroom Lock 8237 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer CLP7500 SN-134 689 NO
Hardware Group 10 (Doors: 15.0, 16.0, 17.0, 29.0, 33.0, 34.0, 35.0, 40.0)
3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D
MK
1 Classroom Lock 8237 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer 7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
RO
1 Wall Stop 409 US32D
Hardware Group 11 (Doors: 38.0, 42.0, 47.0, 48.0, 49.0)
MK
REFUELING WING
DOOR HARDWARE 08 71 00 - 19
Hardware Group 11 (Doors: 38.0, 42.0, 47.0, 48.0, 49.0)
1 Office Lock 8205 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer 7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
Hardware Group 12 (Doors: 13.0, 41.0)
MK
1 Storeroom Lock 8204 LNB LC US26D
SA
1 Cylinder 1E-74 626 BE
1 Door Closer 7500 SN-134 689 NO
1 Door Stop / Holder F41S IV
Hardware Group 13 (Doors: 2.0, 3.0)
1 OH Doors All Hardware by Door Mfg 00
REFUELING WING
DOOR HARDWARE 08 71 00 - 20
Hardware Group 14 (Doors: 1.0, 53.0)
3 Hinge TA2314 NRP 4-1/2" x 4-1/2" US32D
MK
1 Exit Device 8813 ETL US32D
SA
1 Cylinder 1E-74-22 626 BE
1 Door Closer CLP7500 SN-134 689 NO
1 Kick Plate K1050>8" US32D
1 Threshold 171A PE
Hardware Group 15 (Doors: 51.0)
MK
1 Removable Mullion L980 PC SA
1 Exit Device (rim, nightlatch) 8804 863 US32D
SA
2 Exit Device (exit only) 8810 US32D
SA
2 Cylinder 1E-74-22 626 BE
2 Door Closer CLP7500 SN-134 689 NO
1 Threshold 171A PE
REFUELING WING
DOOR HARDWARE 08 71 00 - 21
Hardware Group 15 (Doors: 51.0)
1 Gasketing 332CS PE
1 Rain Guard 346C PE
2 Sweep 315CN PE
Hardware Group 16 (Doors: 50.0)
MK
2 Push Plate 70C US32D
RO
2 Pull Plate 107x70C US32D
RO
2 Door Closer CLP7500 SN-134 689 NO
2 Wall Stop 409 US32D
-- END OF SECTION --