254-_E-503_-_ELECTRICAL_DETAILS.pdf

PDF 307 KB Posted

Attached to
ADAL Two Existing Hangars to Accommodate the New KC46 Tanker
Solicitation number
W912TF15R0500
Issued by

About this file

254- E-503 - ELECTRICAL DETAILS

View the file

Other files

File Type Posted
15R0500-Site_visit_attendees_3-4.21.15.pdf PDF
RFI_answers_FBO_posting_4.20.15.pdf PDF
W912TF-15-R-0500-0008_Amendment_8.pdf PDF
SCZQ139904_LS-101_ADDEDNDUM_2.pdf PDF
NHANG_Bldg_254_Specifications_4.9.15.pdf PDF
NHANG_Bldg_254_Plans_4.9.15.pdf PDF
SZCQ139901_253_FP-101_Addendum2.pdf PDF
SZCQ139904_Plans_Addendum_1.pdf PDF
SZCQ139901_253_FP-102_Addendum2.pdf PDF
SZCQ139904_FP-101_addendum2.pdf PDF
SZCQ139904_FP-102_addendum2.pdf PDF
NHANG_Bldg_253_Plans_4.9.15.pdf PDF
SCZQ139901_LS-101_ADDEDNDUM_2.pdf PDF
SZCQ139901_Plans_Addendum_1.pdf PDF
SZCQ139901_253_FA-102_Addendum2.pdf PDF
SZCQ139904_FA-102_addendum2.pdf PDF
SZCQ139904_Specs_Addendum_1.pdf PDF
NHANG_Bldg_253_Specifications_4.9.15.pdf PDF
W912TF-15-R-0500-0007_Amendment_7.pdf PDF
SZCQ139901_Specs_Addendum_1.pdf PDF
W912TF-15-R-0500-0006_Amendment_6.pdf PDF
W912TF-15-R-0500-0005_Amendment_5.pdf PDF
Consolidated_RFI_answers_FBO_posting_3.31.15.pdf PDF
W912TF-15-R-0500-0003_Amendment_4.pdf PDF
RFI_answers_FBO_posting_3.27.15.pdf PDF
259000__BUILDING_MANAGEMENT_SYSTEM_(BMS)_B253.pdf PDF
259000_-_BUILDING_MANAGEMENT_SYSTEM_(BMS)_B254.pdf PDF
BLD_253-SK-S-1__FALL_PROTECTION_SUPORT_FRAMING_SKETCH.pdf PDF
BLD_254-SP-301-FUSELAGE_FALL_PROTECTION_SECTION.pdf PDF
260536_-_CABLE_TRAYS_FOR_ELECTRICAL_SYSTEMS.pdf PDF
BLD254-_ED-102-ELECTRICAL_POWER_AND_SIGNAL_DEMO_PLAN.pdf PDF
BLD_254-E-110_-_SUPPORT_AREA_POWER_AND_SYSTEMS_PLAN.pdf PDF
BLD_253-260536_-CABLE_TRAYS_FOR_ELECTRICAL_SYSTEMS.pdf PDF
028200_-_Asbestos_Abatement_2015-03-14.pdf PDF
BLD_253-SP-301_-_FUSELAGE_FALL_PROTECTION_SECTION.pdf PDF
BLD_253-ED-102-ELECTRICAL_POWER_AND_SIGNAL_DEMO_PLAN.pdf PDF
BLD_254-E-602_-_PANEL_SCHEDULES.pdf PDF
BLD_253-E-602-PANEL_SCHEDULE.pdf PDF
BLD_254-E-601_-_SINGLE_LINE_DIAGRAM.pdf PDF
BLD_253-E-002_-_ELECTRICAL_SITE_PLAN.pdf PDF
RFI_answers_FBO_posting_3.20.15.pdf PDF
011400_-_Work_Restrictions_Rev_031715_Maint_Hangar.pdf PDF
011400_-_Work_Restrictions_Rev_031715_Fuel_Cell.pdf PDF
254-_E-603_-_PANEL_SCHEDULES.pdf PDF
254-_E-108_-_NORTH_HANGAR_AREA_POWER_ _SYSTEMS_PLAN_REV.pdf PDF
SECTION_087100_-_DOOR_HARDWARE-Rev.pdf PDF
253-_263543_-_400_HZ_Solid_State_Frequency_Converter.pdf PDF
W912TF-15-R-0500-0003_Amendment_3.pdf PDF
253-_E-108_-_NORTH_HANGAR_AREA_POWER_ _SYSTEMS_PLAN_REV.pdf PDF
253-_E-601_-_SINGLE_LINE_DIAGRAM.pdf PDF
Show 40 more

Latest 50 of 79 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project

Client

Drawing

NEW HAMPSHIRE AIR NATIONAL GUARD

REVISIONS

Description

Drawn by

Designed by

Scale

Date

Project No.

Approved by

Checked by Date

SheetAS SHOWN

Stamp

PEASE AIR BASE

NEW HAMPSHIRE

NATIONAL GUARD

31 DECEMBER 2014

KC-46A ADAL MAINTENANCE HANGAR, BUILDING 254

PEASE AIR NATIONAL GUARD BASE, NEW HAMPSHIRE

SZCQ139904

MGD

MGD

WAP

LDC

B-3 Resubmittal

B-3 Submittal

B-2 Submittal

12/31/14

11/21/14

08/15/14 E-503

ELECTRICAL DETAILS

1 REVISION 1 02/17/15

2 REVISION 2 03/03/15

CABLE PATHWAY HOME RUN TO

COMM ROOM 13A. (TYPICALLY

FOLLOWS CORRIDORS)

CONDUIT TO CABLE TRAY OR TO WITHIN

12" (1 FOOT) OF CABLE TRAY

MINIMUM 3/4" EMT CONDUIT.

STUB-OUT TO CABLE TRAY.

ROUTE ALL CABLE TO

CORRESPONDING TR/ER

ROOM.

SINGLE GANG

EXTENSION

4"X4" DEEP SET

JUNCTION BOX

NOTES:

1. MOUNT 4"X4" JUNCTION BOXES SAME HEIGHT AS ELECTRICAL

UNLESS NOTED OTHERWISE.

2. OUTLET CONFIGURATION SHALL BE AS INDICATED ON PLANS.

CONDUIT AND CABLE TRAY

CONNECTED BY BONDING JUMPER

EXTRA PULL STRING

TYPICAL WORK AREA OUTLET ON EACH 8P8C

(RJ-45) CENTER KEYED JACK. TERMINATE ALL

FOUR 4-PAIR CAT 6 UTP CABLES TO TR PATCH

PANEL PER PROJECT PLAN.

IDENTIFICATION VIA EXTERNAL

AND INTERNAL LABELS.

LABEL METHOD:

RACK LOCATION- RACK NUMBER-

PANEL NUMBER- JACK NUMBER (TYP)

BLUE (TYP) COLOR

MODULE FOR PHONE

8-PIN 8-CONDUCTOR

(8P8C) (RJ-45)

CONNECTOR #1

8-PIN 8-CONDUCTOR

(8P8C) (RJ-45)

CONNECTOR #2

BLUE (TYP) COLOR

MODULE FOR DATA/PHONE

PER ANG STANDARD

CAT 6 CAT 6

CAT 6 CAT 6

BLUE (TYP)

COLOR MODULE

WKSTTV

TV

READY ROOM 11F

TV

READY ROOM 9

BOX 1TV

FLOOR

PROJECTOR 1

TV

BOX 2TV

FLOOR

PROJECTOR 2

TELEVISION

WALL MOUNT

TV

TELEVISION

WALL MOUNT

TELEVISION

WALL MOUNT

TV

ROOM 13D ROOM 41

WKSTTV

TV

ROOM 42B

WKSTTV

TV TV TV

ROOM 13A

COMM / A/V ROOM

A/V TERMINATION

BACKBOARD

(TYPICAL)

TV

OFFICE 11E

TV

OFFICE 11D

TV

OFFICE 11C

TV

OFFICE 11B

HDMI,VGA & RCA CABLES

TO WORKSTATION

(TYPICAL)HDMI,VGA & RCA CABLES

TO FLOOR BOXES

(TYPICAL)

USB, VGA & HDMI

CABLES TO

PROJECTORS

PROJECTOR

KEY NOTES:

PROVIDE RG6/U CMP HORIZONTAL CABLE

IN 1" CONDUIT FROM STATION JACK TO

COMM / A/V ROOM 13A.

PROVIDE F-TYPE STATION JACK IN FLUSH

MOUNT WALL BOX.

PROVIDE CATV "DIGITAL READY" SPLITTER

WITH 24 OUTPUT PORTS. SPLITTER SHALL

BE MOUNTED TO EXISTING A/V

BACKBOARD.

PROVIDE IMPEDANCE MATCHING

TERMINATION DEVICE FOR UNUSED

OUTPUT PORTS IN SPLITTER.

(TYPICAL) 2

3 4

(TYPICAL)

WEST OFFICE

AREA

EXISTING

VOICE/DATA

RACK

EXISTING

TR

X 10 READY ROOM 9

X 1 OPEN AREA 11

X 2 OFFICE 11B

X 2 OFFICE 11C

X 2 OFFICE 11D

X 2 OFFICE 11E

X 3 OFFICE 11F

X 4 READY ROOM 11A

CEILING

GRID

SOUTH SHOP

AREA

X 2 TOOL ROOM 41

X 7 TOOL ROOM 42B

HANGAR BAY

X 1 HANGAR WEST

X 1 HANGAR WEST

3/4"C PER OUTLET TO

ACCESSIBLE CEILING

J

3/4"C PER OUTLET TO

JUNCTION BOX

2 3

2-1/2"C TO DATA

ROOM J

3/4"C PER OUTLET TO

JUNCTION BOX

X 1 BAS PANEL

3/4"C PER OUTLET TO

JUNCTION BOX

X 2 READY ROOM 9

1"C TO ACCESSIBLE CEILING

UNDERSLAB TO WALL; 3/4"C

TO ACCESSIBLE CEILING

HDMI,VGA & RCA CABLES

TO WORKSTATION OUTLET

USB, VGA & HDMI CABLES

TO PROJECTOR

X 1 HANGAR EAST

X 1 HANGAR EAST

1"C UNDERGROUND TO WALL

BENEATH J-BOX. TURN CONDUIT

UP WALL TO JUNCTION BOX.J

3/4"C PER OUTLET TO

JUNCTION BOX

X 1 TOOL ROOM 42B

LOCKER ROOM

AREA

X 1 WOMEN'S LOCKER 18

X 1 MEN'S LOCKER 16

3/4"C PER OUTLET TO

TR ROOM

X 1 ADVANTOR INFRAGUARD

PANEL

KEY NOTES:

PROVIDE 48 PORT, CAT-6, TYPE 568B WIRING, RACK

MOUNTED PATCH PANEL. UTILIZE BLANK SPACE IN

EXISTING DATA RACK.

PROVIDE 4-PAIR, CAT-6, 24 AWG SOLID Cu UTP

CABLING FROM COMMUNICATION RACK PATCH

PANEL TO EACH COMMUNICATION JACK, UON. REFER

TO PLANS FOR OUTLET LOCATIONS. ROUTE CONDUIT

AS INDICATED. ALL CABLING SHALL BE PLENUM

RATED.

PROVIDE 1" SCH 40 PVC CONDUIT ROUTED

UNDERSLAB W/ CAT-6 CABLING LABELED AND RATED

FOR WET LOCATION TO EACH VOICE/DATA FLOOR

BOX SHOWN ON PLANS.

PROVIDE 12 STAND/6 PAIR 1 RU HIGH FIBER PATCH

PANEL WITH 12 FIBER ST DUPLEX SINGLE MODE

ADAPTER PLATES AND WITH FIBER SPLICE TRAYS.

PROVIDE 24 PORT, CAT-6, TYPE 568B WIRING PATCH

PANEL.

#1/0 COPPER CABLE

WITH TINNED COPPER

LUG EXTEND CABLE AND

BOND TO GROUND GRID

IN HIGH BAY.

GENERAL DETAIL NOTES:

IN ADDITION TO MATERIALS INDICATED IN

TELECOMMUNICATION WIRING DIAGRAM, PROVIDE THE

FOLLOWING:

1. PRETIUM UNICAM TERMINATION KIT,

MANUFACTURER PART NUMBER: TKT-UNICAM-PFC

2. UNICAM PRETIUM SC CONNECTOR PACK OF 25,

MANUFACTURER PART NUMBER: 95-000-41-Z

3. UNICAM PRETIUM LC CONNECTOR PACK OF 25,

MANUFACTURER PART NUMBER: 95-050-99-Z

3. UNICAM PRETIUM ST CONNECTOR PACK OF 25,

MANUFACTURER PART NUMBER: 95-050-51-Z

4. FUJIKURA 12S FUSION SPLICER KIT 1,

MANUFACTURER PART NUMBER:S015522

3/4"C TO TR ROOM

24 STRAND, HYBRID (12 STRAND MM +

12 STRAND SM) FIBER OPTIC CABLE

EXTEND CATEGOARY 6 CABLES TO

FIBER SWITCH

File details come from the government source that posted it. Updated .