254-_E-603_-_PANEL_SCHEDULES.pdf
PDF 232 KB Posted
- Solicitation number
- W912TF15R0500
About this file
254- E-603 - PANEL SCHEDULES
View the file
Other files
Show 40 more
Latest 50 of 79 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project
Client
Drawing
NEW HAMPSHIRE AIR NATIONAL GUARD
REVISIONS
Description
Drawn by
Designed by
Scale
Date
Project No.
Approved by
Checked by Date
SheetAS SHOWN
Stamp
PEASE AIR BASE
NEW HAMPSHIRE
NATIONAL GUARD
31 DECEMBER 2014
KC-46A ADAL MAINTENANCE HANGAR, BUILDING 254
PEASE AIR NATIONAL GUARD BASE, NEW HAMPSHIRE
SZCQ139904
MGD
MGD
WAP
LDC
B-3 Resubmittal
B-3 Submittal
B-2 Submittal
12/31/14
11/21/14
08/15/14 E-603
PANEL SCHEDULES
2 REVISION 2 03/03/15
REVISION 1 02/17/151
38546 PEASE BLDG 254 PANELBOARD LP-3
FEED FROM MCC MOUNTING SURFACE
CKT. CKT. BKR. LOAD CKT. BKR. CKT.
NO. TRIP/POLE KVA A B C KVA TRIP/POLE NO.
1 20 1 SPARE 0.0 SPARE 20 1 2
3 20 1 SPARE 0.0 SPARE 20 1 4
5 20 1 SPARE 0.0 SPARE 20 1 6
7 25 1 B-1 2.4 2.5 0.1 RADIANT HEATERS/VAV BOXES 20 1 8
9 25 1 B-2 2.4 3.3 0.9 EF-9 20 1 10
11 25 1 FCU-1 1.8 3.0 1.2 EF-10/EF-12 20 1 12
13 30 2 L14-30R DEICING RECEPT 2.2 4.3 2.2 L14-30R DEICING RECEPT 30 2 14
15 " 2.2 4.3 2.2 " 16
17 30 2 L14-30R DEICING RECEPT 2.2 4.3 2.2 L14-30R DEICING RECEPT 30 2 18
19 " 2.2 4.3 2.2 " 20
21 20 1 SPARE 0.0 SPARE 20 1 22
23 20 1 SPARE 0.0 SPARE 20 1 24
25 20 1 RECEPT CABLE REEL 0.4 0.7 0.4 RECEPT CABLE REEL 20 1 26
27 20 1 RECEPT CABLE REEL 0.4 0.9 0.5 RECEPT HANGAR ADDITION 20 1 28
29 20 1 RECEPT CABLE REEL 0.4 1.1 0.7 RECEPT HANGAR ADDITION 20 1 30
31 20 1 RECEPT CABLE REEL 0.4 1.1 0.7 RECEPT HANGAR ADDITION 20 1 32
33 20 1 RECEPT CABLE REEL 0.4 1.1 0.7 RECEPT HANGAR ADDITION 20 1 34
35 20 1 RECEPT CABLE REEL 0.4 0.9 0.5 RECEPT TOOL RM 42B 20 1 36
37 20 1 RECEPT TOOL RM 40 0.5 1.3 0.7 RECEPT TOOL RM 42B 20 1 38
39 20 1 RECEPT TOOL RM 41 0.7 2.2 1.5 TOOL RM 42B CHARGERS 20 1 40
41 20 1 RECEPT TOOL RM 41 0.4 1.3 0.9 RECEPT TOOL RM 42B 20 1 42
43 20 1 TOOL RM 41 CHARGERS 1.5 2.2 0.7 RECEPT TOOL RM 42B 20 1 44
45 20 1 ENCELIUM ECU 0.2 1.8 1.6 LIGHTS: TOOL RMS 41 & 42B 20 1 46
47 20 1 LASER ENGRAVING MACHINE 0.2 1.2 1.1 RECEPT: ROOF & EF-17 20 1 48
49 20 1 BAS PANEL 0.2 0.2 SPARE 20 1 50
51 20 1 EF-18, FCU-3 1.4 1.4 SPARE 20 1 52
53 25 1 FCU-2 1.8 3.7 1.9 ACCU-1/CCU-1/CCU-2 20 2 54
55 20 1 TOOL RM 42B CHARGERS 1.5 3.4 1.9 " 56
57 20 1 ADVANTOR INF PANEL 0.5 1.3 0.8 P-4, P-5, P-6 15 2 58
59 20 1 HANGAR NETWORK SWITCH 0.2 1.0 0.8 " 60
61 20 1 SPARE 0.0 SPARE 20 1 62
63 20 1 SPARE 0.0 SPARE 20 1 64
63 20 1 SPARE 0.0 SPARE 20 1 64
20.0 16.2 16.5 TOTAL PANELBOARD KVA : 53
120/ 208 VOLTAGE
146 AVG. AMPS 200 MAIN CKT. BKR. MINIMUM INTERRUPTING CAPCITY
3 PHASE MAIN LUG MAIN BREAKER 10 KAIC
4 WIRE FULL GROUND BRANCH BREAKER 10 KAIC
38546 PEASE BLDG 254 PANELBOARD LP-4
FEED FROM MCC MOUNTING SURFACE
CKT. CKT. BKR. LOAD CKT. BKR. CKT.
NO. TRIP/POLE KVA A B C KVA TRIP/POLE NO.
1 20 1 ROW 5 LIGHTS WEST 0.7 1.4 0.7 ROW 5 LIGHTS EAST 20 1 2
3 20 1 ROW 5 LIGHTS WEST 0.7 1.4 0.7 ROW 5 LIGHTS EAST 20 1 4
5 20 1 ROW 6 LIGHTS WEST 0.7 1.4 0.7 ROW 6 LIGHTS EAST 20 1 6
7 20 1 ROW 6 LIGHTS WEST 0.7 1.4 0.7 ROW 6 LIGHTS EAST 20 1 8
9 20 1 ROW 7 LIGHTS WEST 0.7 1.4 0.7 ROW 7 LIGHTS EAST 20 1 10
11 20 1 ROW 7 LIGHTS WEST 0.7 1.4 0.7 ROW 7 LIGHTS EAST 20 1 12
13 20 1 ROW 8 LIGHTS WEST 0.8 1.6 0.8 ROW 8 LIGHTS EAST 20 1 14
15 20 1 ROW 8 LIGHTS WEST 1.3 2.6 1.3 ROW 8 LIGHTS EAST 20 1 16
17 20 1 ROW 9 LIGHTS WEST 0.6 1.3 0.6 ROW 9 LIGHTS EAST 20 1 18
19 20 1 ROW 9 LIGHTS WEST 1.3 2.6 1.3 ROW 9 LIGHTS EAST 20 1 20
21 20 1 ROW 10 LIGHTS WEST 1.0 1.9 1.0 ROW 10 LIGHTS EAST 20 1 22
23 20 1 ROW 10 LIGHTS WEST 1.3 2.6 1.3 ROW 10 LIGHTS EAST 20 1 24
25 0.0 26 27 0.0 28 29 0.0 30
7.0 7.3 6.6 TOTAL PANELBOARD KVA : 21
120/ 208 VOLTAGE
58 AVG. AMPS 100 MAIN CKT. BKR. MINIMUM INTERRUPTING CAPCITY
3 PHASE MAIN LUG MAIN BREAKER 10 KAIC
4 WIRE FULL GROUND BRANCH BREAKER 10 KAIC
PEASE BLDG 254 EXISTING MCC
FEED FROM SERVICE
CKT. O/C PROT. LOAD
NO. TRIP/POLE AMPS A B C
1 200 3 NEW PANEL LP-3 55.6 20.0
3 " 45.1 16.2 5 " 45.2 16.3
7 100 3 NEW PANEL LP-4 19.4 7.0
9 " 20.2 7.3 11 " 18.4 6.6
13 EX 3 EXISTING HEATER B-1 EX
15 " EX
17 " EX
19 EX 3 EXISTING HEATER B-2 EX
21 " EX
23 " EX
25 EX 3 EXISTING HEATER B-3 EX
27 " EX
29 " EX
31 EX 3 EXISTING TVSS EX
33 " EX
35 " EX
37 EX 3 EXISTING PANEL MDP EX
39 " EX
41 " EX
43 EX 3 EXISTING MAIN BREAKER
45 " 47 "
49 30 2 * NEW PANEL E 4.2 0.5
51 4.2 0.5
Additional Load on MCC 27.5 24.0 22.9
MAIN BUS RATING 800
MAIN BREAKER RATING 600
NOTE: NEW OVERCURRENT PROTECTIVE DEVICES SHALL
MATCH EXISTING SCCR RATINGS OF MCC
208 VOLTAGE
207 AVG. AMPS 600 MAIN FUSE/CKT. BKR.
3 PHASE 800 MAIN BUS
4 WIRE FULL GROUND
* PROVIDE LOCK-ON BREAKER PAINTED RED. PROVIDE RED LABEL WITH
WHITE LETTERING PLACARD ADJACENT TO PANEL NAMEPLATE WITH THE
FOLLOWING INSCRIPTION: "FIRE PROTECTION/LIFE SAFETY EQUIPMENT"
38546
38546 PEASE BLDG 254 PANELBOARD LP-E
FEED FROM MCC MOUNTING SURFACE
CKT. CKT. BKR. LOAD CKT. BKR. CKT.
NO. TRIP/POLE KVA A B KVA TRIP/POLE NO.
1 20 1 FMCP 0.5 0.5 0.0 SPARE 20 1 2
3 20 1 FSCP 0.5 0.5 0.0 SPARE 20 1 4
5 20 1 SPARE 0.0 0.0 SPARE 20 1 6
7 0.0 8 9 10
0.5 0.5 TOTAL PANELBOARD KVA : 1
120/ 208 VOLTAGE
5 AVG. AMPS MAIN CKT. BKR. MINIMUM INTERRUPTING CAPCITY
1 PHASE 50 MAIN LUG MAIN BREAKER 10 KAIC
3 WIRE FULL GROUND BRANCH BREAKER 10 KAIC