About this file

CLIN_-_003_RFI_00010-Site_Elec

View the file

Other files

File Type Posted
CLIN_-_005_RFI_00002-ElecCondClr.pdf PDF
Attachment_7.5_-_CLIN-005_Waka_BOQ.pdf PDF
Attachment_1.4_-_CLIN-004_Gimbichu_Design_Drawings.pdf PDF
Attachment_1.1_-_CLIN-001_Arsi_Negelle_Design_Drawings.pdf PDF
CLIN_-_003_RFI_00021-PitLatSink.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_001_RFI_00002_fixing_PVCCeiling.pdf PDF
CLIN_-_003_RFI_00016-ExtPVLight.pdf PDF
Attachment_3.1-_CLIN-002_Batu_General_Punch_List.xlsx XLSX spreadsheet
Attachment_3.2_-_CLIN-002_Batu_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_4.1_-_CLIN-003_Durame_General_Punch_List.xlsx XLSX spreadsheet
Attachment_7.4_-_CLIN-004_Gimbichu_BOQ.pdf PDF
Attachment_1.4.a_-_CLIN-004_Gimbichu_Soak_Away_Pit_Drawing_Details.pdf PDF
CLIN_-_003_RFI_00001-Various.pdf PDF
CLIN_-_004_RFI_00021_-FlexibleConduits.pdf PDF
CLIN_-_005_RFI_00023-ExtPVLight.pdf PDF
Attachment_6.2_-_CLIN-005_Waka_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_7.3_-_CLIN-003_Durame_BOQ.pdf PDF
CLIN_-_003_RFI_00090-AntirustElectrode.pdf PDF
Attachment_1.5_-_CLIN-005_Waka_Design_Drawings.pdf PDF
CLIN_-_003_RFI-00011-WaterSupplyLines.pdf PDF
CLIN_-_005_RFI_00003_Various2.pdf PDF
CLIN_-_002_RFI_00023-ExtPVLight.pdf PDF
SOL-663-15-000028.pdf PDF
Attachment_2.2_-_CLIN-001_Arsi_Negele_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_5.2_-CLIN-004_Gimbichu__Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_1.3_-_CLIN-003_Durame_Design_Drawings.pdf PDF
CLIN_-_005_RFI_00014_SiteElectrical.pdf PDF
CLIN_-_004_RFI-00009_Various.pdf PDF
Attachment_7.2_-_CLIN-002_Batu_BOQ.pdf PDF
CLIN_-_003_RFI_00009-SanitaryManholes.pdf PDF
Attachment_4.2_-_CLIN-003_Durame_Electrical_Punch_List.xlsx XLSX spreadsheet
CLIN_-_002_RFI__00020_ElectricManhole-HoldingTank.pdf PDF
CLIN_-_002_RFI_00007_WtrSuppLinesDelivBlock.pdf PDF
CLIN_-_004_RFI_00011_-_EpoxyFlrFin.pdf PDF
Attachment_7.1_-_CLIN-001_Arsi_Negele_BOQ.pdf PDF
CLIN_-_001_RFI_00007-GalvStlWaterSvcPiping.pdf PDF
Attachment_1.2_-_CLIN-002_Batu_Design_Drawings.pdf PDF
CLIN_-_001_RFI-00011-PumpPowerSupply.pdf PDF
CLIN_-_004_RFI_00008-ElecCondClr.pdf PDF
Attachment_1.0_-_Final_Spec_Health_Centers_Renovation.pdf PDF
CLIN_-_003_RFI_00006-IDStair.pdf PDF
CLIN_-_004_RFI_00026-PitLatrineFFL.pdf PDF
CLIN_-_004_RFI_00005_Various.pdf PDF
CLIN_-_002_RFI_00022_-_FlexibleConduits.pdf PDF
CLIN_-_004_RFI_00022-ExtPVLight.pdf PDF
Attachment_6.1_-_CLIN-005_Waka_General_Punch_List.xlsx XLSX spreadsheet
CLIN_-_001_RFI_00008-WallCerTile.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_003_RFI_00019-PitLatHPL.pdf PDF
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USAID/EHIP

New Health Center Construction Task Order 8, Combined RFI Log

Durame Site 202 Batu Site 251 Gimbichu Site 208 Arsi Negele Site 277 Waka Site 213 Meki Site 290

RFI No. Date Rec'd Item No. Question TT Response Response Date Follow-up

8-May-14 1 The electrical line from MDB at OPD Block to SDB at Administration Block (EL - 007) requires chiseling of the grade beam of Administration Block which might affect the stability of the block. (Please find attached the picture showing the pve pipe at entrance to Administration Block). We request your approval to use surface mounted weather proof u PVC pipes as shown on Meki engineer's answer to RFI 00003.

Proposed solution is acceptable. Construct above grade electrical installation per attached details on EX-502.

2 The telephone line at Administration Block is shown to come from the left side of the Administration Block to the terminal box (EL - 003).

However, it is not clear up to where the telephone lines are to be installed by Subcontractor since it is not shown in the Site Electrical Plan.

The verandah floor finish is to remain and so is the telephone line to be installed undemeath the floor? Please clarify.

Pull the telephone line overhead per the attached revised sheet Administration/ANC Block Electrical Plan EL-003.

Durame 00010

16-May-14

P:\01298\127-01298-11002\Construction\RFIs\TO#8 - Combined RFI's\RFI Log TO#8 COMBINED

FINANCE

OFFICE

HEAD

OFFICE ANC

NURSE STATION

TOILET STORE

MOTHER TO

MOTHER

EXPANDED

PROGRAM OF

IMMUNIZATION

FAMILY

PLANNING

VERENDAH

ADMINISTRATION/ANC BLOCK LIGHTING LAYOUT

4 1

2 2 2 2 2

LPP-B

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0850.00

SUB TOTAL

kVA CONNECTED

2700.00

LINE AMPERE

kVA DEMAND

DIVERSITY

07.30

11.09 07.30 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-B

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MDB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

16 Ampere, 3 Phase, ACB

(4x2.5+1x2.5) sq mm

2200.00

163x2.5 1Lighting

C163x2.5 1 C161 C161

4 1000.00

1000.00 3x2.5 3x2.5

Spare Spare Spare

C163x2.5 1 C161 C161

1200.00

C163x2.5 1

C161

1200.00

(mm²)

Socket Outlet Socket Outlet Socket Outlet

Water Heater

2400.00

0850.00 1200.00

Socket Outlet

FINANCE

OFFICE

HEAD

OFFICE ANC

NURSE

STATION

TOILET

STORE

MOTHER TO

MOTHER EXPANDED

PROGRAM OF

IMMUNIZATION

FAMILY

PLANNING

VERENDAH

ADMINISTRATION/ANC BLOCK SOCKET & TEL. SYSTEM LAYOUT

LPP-B4

T T

Overhead Tel Intake line from Tel Utility Company System

Main Tel Terminal Box

EXISTING

STONE

WALKWAY

New Tele company pole

EL-003

A D

M

IN

IS

TR

A

TI

O N

A

N C

B

LO

C K E

LE

C

TR

IC

A L

P

LA

N

ADMINISTRATION/ANC

BLOCK ELECTRICAL PLAN

BT BT

TE

TR

A

T

EC

H

A

PR

IL

U

S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

KMD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

DA

TE

AP

R

SY

MB

NOTE: A3 SIZE REDUCED TO HALF SCALE

RENOVATION

(DURAME)

SITE # 202

D U

R A

M E H

E A

LT

H

C E N

T E R

R E N

O V

A T

IO

N

S

IT

E N

O

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/1 4/

0%

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/0 5/

0 5m1 2 3 41

Scale 1:50

R

FI

International Relicf & Developmelll

TK International Bulding NO.2 5th fioor Addis Ababa, PROJECT: TO-14-00003(TO#8)Durame Renovation

TO: USAIDIET

US Embassy Addis Ababa, ATTN: Roger Sydney

WE ARE SENDING:

D Shop Drawings

D Letter

D Prints

D Change Order

D Plans

D Samples

D Specifications

Iif üther: Request for Information

ITEM PACKAGE REV.

RFI

Remarks:

CC: IRD Document Control

P.O. Box 6005

SUBMITTED FOR:

D Approval

D YourUse

D As Requested

[i'f Review and Comment

SENTVIA:

Iif Attached

D Separate Cover Via: Mail

COPIES DATE

5/8/2014 www.ird.org

TRANSMITTAL

No. 00032

DATE: Thursday, May 08,2014

REF: Request for Information

ACTION TAKEN:

D Ap1lI'oved as Submitted

D Approved as Noted

D Retumed After Loan

D Resubmit

I [iIf Submit

D Returned

D Retumed for Corrections

D Due Date:

DESCRIPTION STATUS

Different Issues - 2 OPN

Signed: """"74~:::::::::"":=:::~+==-

Tel.: +251-016-630023

International Relief & Development

TK International Building NO.2

5th floor

Addis Ababa

TITLE: Different Issues - 2

PROJECT: TO-14-00003(TO#8) Durame Renovation

TO: USAID/ET

Addis Ababa

ATTN: Roger Sydney

QUESTION:

REQUEST FOR INFORMATION

No. 00010

DATE: Thursday, May 08,2014

Contract No.: TO#8

US Embassy

1. The electricalline from MDB at OPD Block to SDB at Administration Block (EL - 007) requires chiseling of the grade beam of Administration Block which might affect the stability of the block. (Please find attached the picture showing the pve pipe at entrance to Administration Block). We request your approval to use surface mounted weatherproofuPVC pipes as shown on Meki engineer's answer to RPI 00003.

2. The telephone line at Administration Block is shown to come from the left side of the Administration Block to the terminal box (EL - 003). However, it is not c1ear up to where the telephone lines are to be installed by Subcontractor since it is not shown in the Site Electrical Plan. The verandah floor finish is to remain and so is the telephone line to be installed undemeath the floor? Please clarify.

Note: IRD has not assessed the full impaet of this issue in terms of additional eost and extension oftime. IRD reserYes the right to submit a claim as provided in Contraet Section I.

Requested By: International Reliefand Development

(j ~ Signed:~

~er Page 1 of 1

P.O. Box 6005 www.ird.org Tel.. +251-0116-630023

TO#8

BELOW GRADE:

50MM DIA PVC

PIPE

ABOVE GRADE:

50MM DIA

WEATHERPROOF

UPVC PIPE

GALV METAL

BRACKET WITH

CONC ANCHORS

SPACED 1M OC

AND AT ALL

TURNS &

JUNCTURES, TYP

TO BLDG

INTERIOR

ELEC

INSTALLATION

SUB OR MAIN DIST

BOARD

EXST EXT WALL

EXST VERANDAH

EXST SOFFIT

50MM DIA

WEATHERPROOF

UPVC PIPE

ATTACHED WITH

GALV METAL

BRACKETS W/

CONC ANCHORS

SPACED 1 M OC

TO OTHER

BLOCKS WHERE

REQ

BELOW GRADE:

50MM DIA PVC PIPE

ABOVE GRADE:

50MM DIA

WEATHERPROOF

UPVC PIPE

GALV METAL

BRACKET WITH

CONC ANCHORS

SPACED MAX 1M

OC

EXST SOFFIT

EXST EXT WALL

SUB OR MAIN DIST

BOARD

T Y

P

S

I T

E

E

L E

C

D

E T

A I L

S

EX-502

STANDARD

DETAIL BOOK

w w w t e t r a t e c h c o m

O n e

G r a n t

S t r e e t

F r a m i n g h a m

M

A

P

M

P

D

O C

S S

I T

E S

R

E N

O V

A T

I O

N S

R

E N

O V

A T

I O

N

S

T A

N D

A R

D

D

E T

A I L

B

O O

K S

H E

E T

F I L

E S

E

H I P

E

X

E

L E

C D

T L

S D

W G

M

A S

O N

K

E R

R Y

ABOVE GRADE ELEC CONDUIT

INSTALLATION DETAIL AT VERANDAH5

SCALE: 1:10

ABOVE GRADE ELEC CONDUIT

INSTALLATION DETAIL AT EXT WALL6

SCALE: 1:10

File details come from the government source that posted it. Updated .