CLIN_-_002_RFI__00020_ElectricManhole-HoldingTank.pdf

PDF 1 MB Posted

Attached to
Completion of Five Health Centers Renovation near Awassa Project in the communities of Arsi Negele, Batu, Durame, Gimbichu, and Waka
Solicitation number
SOL-663-15-000028
Issued by

About this file

CLIN_-_002_RFI__00020_ElectricManhole-HoldingTank

View the file

Other files

File Type Posted
CLIN_-_005_RFI_00002-ElecCondClr.pdf PDF
Attachment_7.5_-_CLIN-005_Waka_BOQ.pdf PDF
Attachment_1.4_-_CLIN-004_Gimbichu_Design_Drawings.pdf PDF
Attachment_1.1_-_CLIN-001_Arsi_Negelle_Design_Drawings.pdf PDF
CLIN_-_003_RFI_00021-PitLatSink.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_001_RFI_00002_fixing_PVCCeiling.pdf PDF
CLIN_-_003_RFI_00016-ExtPVLight.pdf PDF
Attachment_3.1-_CLIN-002_Batu_General_Punch_List.xlsx XLSX spreadsheet
Attachment_3.2_-_CLIN-002_Batu_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_4.1_-_CLIN-003_Durame_General_Punch_List.xlsx XLSX spreadsheet
Attachment_7.4_-_CLIN-004_Gimbichu_BOQ.pdf PDF
Attachment_1.4.a_-_CLIN-004_Gimbichu_Soak_Away_Pit_Drawing_Details.pdf PDF
CLIN_-_003_RFI_00001-Various.pdf PDF
CLIN_-_004_RFI_00021_-FlexibleConduits.pdf PDF
CLIN_-_005_RFI_00023-ExtPVLight.pdf PDF
Attachment_6.2_-_CLIN-005_Waka_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_7.3_-_CLIN-003_Durame_BOQ.pdf PDF
CLIN_-_003_RFI_00090-AntirustElectrode.pdf PDF
Attachment_1.5_-_CLIN-005_Waka_Design_Drawings.pdf PDF
CLIN_-_003_RFI-00011-WaterSupplyLines.pdf PDF
CLIN_-_005_RFI_00003_Various2.pdf PDF
CLIN_-_002_RFI_00023-ExtPVLight.pdf PDF
SOL-663-15-000028.pdf PDF
Attachment_2.2_-_CLIN-001_Arsi_Negele_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_5.2_-CLIN-004_Gimbichu__Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_1.3_-_CLIN-003_Durame_Design_Drawings.pdf PDF
CLIN_-_005_RFI_00014_SiteElectrical.pdf PDF
CLIN_-_004_RFI-00009_Various.pdf PDF
Attachment_7.2_-_CLIN-002_Batu_BOQ.pdf PDF
CLIN_-_003_RFI_00009-SanitaryManholes.pdf PDF
Attachment_4.2_-_CLIN-003_Durame_Electrical_Punch_List.xlsx XLSX spreadsheet
CLIN_-_002_RFI_00007_WtrSuppLinesDelivBlock.pdf PDF
CLIN_-_004_RFI_00011_-_EpoxyFlrFin.pdf PDF
Attachment_7.1_-_CLIN-001_Arsi_Negele_BOQ.pdf PDF
CLIN_-_001_RFI_00007-GalvStlWaterSvcPiping.pdf PDF
Attachment_1.2_-_CLIN-002_Batu_Design_Drawings.pdf PDF
CLIN_-_001_RFI-00011-PumpPowerSupply.pdf PDF
CLIN_-_004_RFI_00008-ElecCondClr.pdf PDF
Attachment_1.0_-_Final_Spec_Health_Centers_Renovation.pdf PDF
CLIN_-_003_RFI_00006-IDStair.pdf PDF
CLIN_-_004_RFI_00026-PitLatrineFFL.pdf PDF
CLIN_-_004_RFI_00005_Various.pdf PDF
CLIN_-_002_RFI_00022_-_FlexibleConduits.pdf PDF
CLIN_-_004_RFI_00022-ExtPVLight.pdf PDF
Attachment_6.1_-_CLIN-005_Waka_General_Punch_List.xlsx XLSX spreadsheet
CLIN_-_001_RFI_00008-WallCerTile.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_003_RFI_00019-PitLatHPL.pdf PDF
CLIN_-_003_RFI_00008_GalvStlWaterSvcPiping.pdf PDF
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USAID/EHIP

New Health Center Construction Task Order 8, Combined RFI Log

Durame Site 202 Batu Site 251 Gimbichu Site 208 Arsi Negele Site 277 Waka Site 213 Meki Site 290

RFI No. Date Rec'd Item No. Question TT Response Response Date Follow‐up

1 An electric manhole is shown to be placed ri ght in front of OPD Block (EL ‐ 005). This manhole, at the proposed location, is placed at the center of the compound, car parking and junction of the Health Center.

This will cause inconvenience to the Health Center. We request your approval to shift the manhole location at around 7m towards the guard house (please refer to the attached sketch showing our proposal).

Proposal is acceptable. This has no cost implications.

12‐Aug‐14

2 The top slab of the Holding Tank will be 1.40m beIow the NGL. Since the pit created by this is too deep, the Holding Tank needs to be backfilled by soil. This will cause load on the top slab. Will the Holding Tank structural elements withstand the additional load? Please clarify. Please note that the bottom slab has been constructed and masonry wall is in progress.

Keep elevations and use attached drawing.

This has no cost implications.

12‐Aug‐14

31‐Jul‐14Batu 00020

P:\01298\127‐01298‐11002\Construction\RFIs\TO#8 ‐ Combined RFI's\RFI Log TO#8 COMBINED

C-013

C-013

600 800 2600 800 600

330.0000

80 80

HOLDING TANK MANHOLE

HEIGHT=VARIABLE

RC COVER W/Ø8 STEEL

REIN BARS @ 150MM EACH

WAY

20CM THICK HCB W/

MORTAR FILLED CORE

Ø16 STEEL

BAR HANDLE

STONE MASONRY WALL WITH MORTAR

CONNECTION

M

IN

V A

R

40 120 220 120 40

RC TOP SLAB (LID)

FINISHED GRADE/ NGL

FOUNDATION

M

IN

S

L O

P E2

M

IN

S L O

P E

50 50

PVC INLET PIPE

SEAL ALL AROUND

C-013

H O

LD

IN

G T

A N

K P

LA

N

S

EC

TI

O N

UNLESS OTHERWISE NOTED, ALL

DIMENSIONS SHOWN ARE IN CENTIMETERS.

HOLDING TANK

PLAN & SECTION

D B

D B

TE

TR

A T

EC

H

A

PR

IL

U

S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

KMD

ES

IG

N

ED

B

Y

D W

N B

Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

DA

TE

AP

R

SY

MB

NOTE: A3 SIZE REDUCED TO HALF SCALE

RENOVATION

(BATU)

SITE #251

B A

T U

H E A

LT

H

C E N

T E R

R E N

O V

A T

IO

N

S

IT

E N

O

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/1 4/

0%

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/0 5/

HOLDING TANK FOUNDATION REIN PLAN1

SCALE 1:2

HOLDING TANK LID REIN PLAN2

SCALE 1:20

HOLDING TANK SECTION- MASONRY3

SCALE 1:2

RF

I 0

_U

PD

A

TE

D

/0

4/

Pair of 4 x 10 mm square power feeder cable from EEPCO to KWAH A & B inside

50mm rigid PVC conduit

TO#8 Batu site electrical intake manhole relocation proposal

Sketched by : Haile Demessie Electrical Engineer, IRD-Ethiopia, July 2014

Guard House

OPD Block

Delivery Block m m m m

Manhole position on drawing

Manhole proposed new position

KWH-A

KWH-B

31m

4 x 10 mm square feeder cable from EEPCO to KWAH-A inside

50mm rigid PVC conduit

4 x 10 mm square feeder cable from EEPCO to

KWAH-B inside 50mm PVC conduit

File details come from the government source that posted it. Updated .