CLIN_-_005_RFI_00014_SiteElectrical.pdf

PDF 1 MB Posted

Attached to
Completion of Five Health Centers Renovation near Awassa Project in the communities of Arsi Negele, Batu, Durame, Gimbichu, and Waka
Solicitation number
SOL-663-15-000028
Issued by

About this file

CLIN_-_005_RFI_00014_SiteElectrical

View the file

Other files

File Type Posted
CLIN_-_005_RFI_00002-ElecCondClr.pdf PDF
Attachment_7.5_-_CLIN-005_Waka_BOQ.pdf PDF
Attachment_1.4_-_CLIN-004_Gimbichu_Design_Drawings.pdf PDF
Attachment_1.1_-_CLIN-001_Arsi_Negelle_Design_Drawings.pdf PDF
CLIN_-_003_RFI_00021-PitLatSink.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_001_RFI_00002_fixing_PVCCeiling.pdf PDF
CLIN_-_003_RFI_00016-ExtPVLight.pdf PDF
Attachment_3.1-_CLIN-002_Batu_General_Punch_List.xlsx XLSX spreadsheet
Attachment_3.2_-_CLIN-002_Batu_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_4.1_-_CLIN-003_Durame_General_Punch_List.xlsx XLSX spreadsheet
Attachment_7.4_-_CLIN-004_Gimbichu_BOQ.pdf PDF
Attachment_1.4.a_-_CLIN-004_Gimbichu_Soak_Away_Pit_Drawing_Details.pdf PDF
CLIN_-_003_RFI_00001-Various.pdf PDF
CLIN_-_004_RFI_00021_-FlexibleConduits.pdf PDF
CLIN_-_005_RFI_00023-ExtPVLight.pdf PDF
Attachment_6.2_-_CLIN-005_Waka_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_7.3_-_CLIN-003_Durame_BOQ.pdf PDF
CLIN_-_003_RFI_00090-AntirustElectrode.pdf PDF
Attachment_1.5_-_CLIN-005_Waka_Design_Drawings.pdf PDF
CLIN_-_003_RFI-00011-WaterSupplyLines.pdf PDF
CLIN_-_005_RFI_00003_Various2.pdf PDF
CLIN_-_002_RFI_00023-ExtPVLight.pdf PDF
SOL-663-15-000028.pdf PDF
Attachment_2.2_-_CLIN-001_Arsi_Negele_Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_5.2_-CLIN-004_Gimbichu__Electrical_Punch_List.xlsx XLSX spreadsheet
Attachment_1.3_-_CLIN-003_Durame_Design_Drawings.pdf PDF
CLIN_-_004_RFI-00009_Various.pdf PDF
Attachment_7.2_-_CLIN-002_Batu_BOQ.pdf PDF
CLIN_-_003_RFI_00009-SanitaryManholes.pdf PDF
Attachment_4.2_-_CLIN-003_Durame_Electrical_Punch_List.xlsx XLSX spreadsheet
CLIN_-_002_RFI__00020_ElectricManhole-HoldingTank.pdf PDF
CLIN_-_002_RFI_00007_WtrSuppLinesDelivBlock.pdf PDF
CLIN_-_004_RFI_00011_-_EpoxyFlrFin.pdf PDF
Attachment_7.1_-_CLIN-001_Arsi_Negele_BOQ.pdf PDF
CLIN_-_001_RFI_00007-GalvStlWaterSvcPiping.pdf PDF
Attachment_1.2_-_CLIN-002_Batu_Design_Drawings.pdf PDF
CLIN_-_001_RFI-00011-PumpPowerSupply.pdf PDF
CLIN_-_004_RFI_00008-ElecCondClr.pdf PDF
Attachment_1.0_-_Final_Spec_Health_Centers_Renovation.pdf PDF
CLIN_-_003_RFI_00006-IDStair.pdf PDF
CLIN_-_004_RFI_00026-PitLatrineFFL.pdf PDF
CLIN_-_004_RFI_00005_Various.pdf PDF
CLIN_-_002_RFI_00022_-_FlexibleConduits.pdf PDF
CLIN_-_004_RFI_00022-ExtPVLight.pdf PDF
Attachment_6.1_-_CLIN-005_Waka_General_Punch_List.xlsx XLSX spreadsheet
CLIN_-_001_RFI_00008-WallCerTile.pdf PDF
CLIN_-_004_RFI_00029-WaterSupplyLines.pdf PDF
CLIN_-_003_RFI_00019-PitLatHPL.pdf PDF
CLIN_-_003_RFI_00008_GalvStlWaterSvcPiping.pdf PDF
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USAID/EHIP

New Health Center Construction Task Order 8, Combined RFI Log

Durame Site 202 Batu Site 251 Gimbichu Site 208 Arsi Negele Site 277 Waka Site 213 Meki Site 290

RFI No. Date Rec'd Item No. Question TT Response Response Date Follow-up

1 The Site Electrical Plan shows only two electrical manholes to be constructed, one at Delivery Block and the other at EPl Block (EL - 006).

However, additional manholes are needed at junctions and bends at all other blocks for the purpose of maintenance. Please clarify.

1. 6 additional 600x600x700mm dimension manholes are required.

Revised Electrical Site Plan EL-006 and Typical Site Electrical Details EX- 501 and EX-502 are attached.

2 Pit Latrine Lighting Layout (EL - 003) calls for the lighting line to come from Registration Block. Since it is not shown in the site electrical plan, in what way is the lighting line to come? Underground or overhead? Please clarify.

2. A 3x2.5mm sq under ground power supply cable is to be drawn from LPP-B to the Pit Latrine. Use the spare circuit breaker 6 as a supply for the Latrine lighting. Please see the amended site and block drawings, EL-003 and EL-006. Also note the changes in Distribution schedule LPP-B.

3. Additionally, the main switches of MDB and LLP-A are currently designed to work at almost 100% of critical load. However, a circuit breaker is not recommended to carry more than 80% nominal load for more than 3 hours. They should be upgraded per attached Revised Sheet EL-001, Main Power Supply Detail and Distribution Schedule.

14-May-14

16-May-14

Waka 00014

P:\01298\127-01298-11002\Construction\RFIs\TO#8 - Combined RFI's\RFI Log TO#8 COMBINED

( MAIN DISTRIBUTION BOARD )

Pmax.= 30.77 kVA Ptot.= 43.95 kVA

3x50A(4x10) sq mm

Am p, P ha se , 4

W

E, 0.

Po w er

F ac to r, H z

No

LPP-A

Distribution Panel A(mm )2 I(A)

15.85

Load (kVA)

LPP-B 04.80

LPP-C 06.50

LPP-D 03.70

LPP-E (Delivery) 1x25 04.25 LPP-F (TB & EPI) 1x20 03.20

Spare Spare Pump Control Panel

2x4+1x4

Spare

3x16 03.004x4+1x4 1x25 1x25 3x16

LPP-G (Woreda store) 02.65

(1x10) sq mm

2x6+1x6

3x164x2.5+1x2.5 3x164x2.5+1x2.5 3x254x6+1x6

1x252x6+1x6

1x202x4+1x4 Power Utility Company Transformer

15/0.4kV, 4Wire+E, 0.8Cos , 50Hz kWatt- Hour-Meter

By the Power Utility Company

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 25 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C

1RATING

BREAKER

TYPE

SUB TOTAL

kVA CONNECTED

14400.00

LINE AMPERE

kVA DEMAND

DIVERSITY

43.950

46.743 30.765 00.700

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, MDB

SERVICE

VOLTAGE :

PANEL NO :

SIZE OF

WIRE

CIRCUIT

NUMBER

DESCRIPTION

EEPCo Power Supply System

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

50 Ampere, 3 Phase, ACB

(4x10+1x10) sq mm

25LPP-A

Pump Control Panel Spare Spare

3700.00

CLPP-B

C16LPP-C

CLPP-D

C25LPP-E (Delivery)

LPP-F (TB & EPI) C203x4

15300.00 14250.00

Spare

C165x4 3 1000.001000.00 1000.00

(mm²)

LPP-G(Woreda store)

3x6 1

C

C C C

4250.00

3200.00 2650.00

5300.00 5350.005200.00

1800.001800.00 1200.00

2050.002050.00 2400.00

5x6

5x2.5 5x2.5 3x6

3x4

2. If earthing resistance is greater than 5 Ohm additional electrode shall be buried spaced not less than the length of the electrode.

1. Earthing resistance shall not be greater than 5 Ohm.

NOTE

Earthing conductor 1x10 sq mm to MDB

Earthing Rod copper clad steel Diameter 16 mm, length 2400 mm

Ground level

Manhole 700x700x700 mm

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

SUB TOTAL

kVA CONNECTED

LINE AMPERE

kVA DEMAND

DIVERSITY

15.85

24.08 15.85 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-A

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MDB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

25 Ampere, 3 Phase, ACB

(4x6+1x6) sq mm

163x2.5 1Lighting

C163x2.5 1 C161 C161

3x2.5 3x2.5

Spare Spare Spare

C163x2.5 1

C161 C161

C163x2.5 1

C161

(mm²)

Socket Outlet Socket Outlet

Water Heater Water Heater

Socket Outlet Socket Outlet Socket Outlet Socket Outlet

Lighting Lighting

C1613x2.5 C163x2.5 1 C1613x2.5 C163x2.5 1 C163x2.5 1

Socket Outlet

C163x2.5 1

5350.00

1200.00

1200.00 1200.00

1200.00

0800.00

5200.00

1400.00

0900.00

1000.00

1200.00

5300.00

0750.00

1200.00 1400.00

1200.00

Water Heater C163x2.5 1 1200.00

EL-001

M A

IN

P

O W

ER

S

U P P

LY

D

ET

A

IL

A N

D

D

IS

TR

IB

U

TI

O N

S C

H

ED

U

LE

MAIN POWER SUPPLY DETAIL AND

DISTRIBUTION SCHEDULE, SCALE NTS

BT BT

TE

TR

A

T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

KM

D

ES

IG

N

ED

B

Y

D R A

W N

B Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

D A

TE

A

PR

SY

M B

NOTE: A3 SIZE REDUCED TO HALF SCALE

RENOVATION

(WAKA)

SITE # 213

W A

K A

H

EA

LT

H

C

EN

TE

R

R

EN

O V

A

TI

O N

S

IT

E N

O

D

ES

C

RI

PT

IO

N

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/1 4/

/0

5/

0%

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

Kerry.Mason Oval

Kerry.Mason Oval

Kerry.Mason Oval

Kerry.Mason Oval

Kerry.Mason Line

Kerry.Mason Line

Kerry.Mason Text Box 63 Amp

Kerry.Mason Text Box 40 Amp

DRUG STORE

INFECTIOUS

DISEASE

CLINIC DISPENSARY

VERENDAH

WAITING

REGISTR.

ROOM

WAITING

AREA

CASHER

YOUTH FRIENDLY

SERVICE

2 2 2 2

1 1 1

1 1

REGISTRATION BLOCK LIGHTING LAYOUT

LPP-B

2 2

2 2

FLUSH

ENCLOSURE :

BUS RATING :

BUS TYPE :

SHEET STEEL

63A, 10 kA

TPN+PE

IP RATING :

DRWG. NO. :

MOUNTING :

31 2

BUS CONNECTION

(VOLT-AMPERE)

C C

1RATING

BREAKER

TYPE

0550.00

SUB TOTAL

kVA CONNECTED

1800.00

LINE AMPERE

kVA DEMAND

DIVERSITY

04.80

07.29 04.80 01.00

CIRCUIT LOAD PER PHASE

4 Wire+E, 50 Hz 380/220 Volt, 3 Phase, LPP-B

SERVICE

VOLTAGE :

PANEL NO :

SIZE

3x2.5 1

OF

WIRE

CIRCUIT

NUMBER

Lighting

DESCRIPTION

MDB

TOP

MAIN SWITCH

FEEDER

POWER SOURCE

LOCATION

NUMBER

POLES

DISTRIBUTION BOARD SCHEDULE

16 Ampere, 3 Phase, ACB

(4x2.5+1x2.5) sq mm

1800.00

163x2.5 1Lighting

C163x2.5 1 C161

3x2.5 Pit Latrine Spare Spare

C161 C161

C163x2.5 1

C161

(mm²)

Socket Outlet Socket Outlet Socket Outlet

1200.00

800.00 1000.00

1200.00 1000.00

3x2.5 0250.00

DRUG STORE

INFECTIOUS

DISEASE

CLINIC

DISPENSARY

VERENDAH

WAITING

REGISTR.

ROOM

WAITING

AREA

CASHER

YOUTH FRIENDLY

SERVICE

YOUTH FRIENDLY

SERVICE

LPP-B

REGISTRATION BLOCK SOCKET LAYOUT

U LAT

STAFF LAT

M LAT F LAT

A B C

5 5 5 5 6 Lighting Line from Registration Block

LPP-B Circuit Number 6

PIT LATRINE BLOCK LIGHTING LAYOUT

EL-003

R

EG

IS

TR

A

TI

O N

B

LO

C K A

N D

P

IT

L A

TR

IN

E

EL

EC

TR

IC

A L

P

LA

N

REGISTRATION BLOCK AND PIT LATRINE

ELECTRICAL PLAN

BT BT

TE

TR

A

T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

KM

D

ES

IG

N

ED

B

Y

D R A

W N

B Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

D A

TE

A

PR

SY

M B

NOTE: A3 SIZE REDUCED TO HALF SCALE

RENOVATION

(WAKA)

SITE # 213

W A

K A

H

EA

LT

H

C

EN

TE

R

R

EN

O V

A

TI

O N

S

IT

E N

O

D

ES

C

RI

PT

IO

N

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/1 4/

/0

5/

0%

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

0 5m1 2 3 41

Scale 1:50

R

FI

EEPCo LINE

4x10mm² UG supply line to KWH-Meter in 50mm diameter PVC

Power Line from EEPCo Kilowatt Hour Meter TO MDB

KWH

LPP-A

MDB

Manhole 700x700x700mm with 16 x 2400mm Earth Rod

(4x6+1x6 mm²) supply line from MDB to LPP-A in 50mm diameter PVC

4x10+1x10mm² supply line to MDB in 50mm diameter PVC in ceiling

(4x2.5+1x2.5 mm²) UG supply line from MDB to LPP-C in 50mm diameter

PVC

(4x2.5+1x2.5 mm²) supply line from MDB to LPP-B in

50mm diameter PVC in ceiling

SITE ELECTRICAL POWER DISTRIBUTION LAYOUT

REGISTRATION BLOCK

DELIVERY BLOCK

LABORATORY BLOCK

DELIVERY BLOCK

ART BLOCK

CAFETERIA

TB & EPI BLOCK

LAUNDRY BASIN

SHOWER

PIT LATRINE

LPP-B

LPP-C

LPP-D

(2x6+1x6 mm²) supply line from MDB to LPP-D in 50mm diameter PVC in ceiling from EEPCo Power Line to Kilowatt Hour Meter

Manhole 600x600x700mm(TYP)

UPVC PIPE DIAM 50MM(TYP)

(3x2.5mm²) UG supply cable from LPP-B to Pit Ltrine in

32mm diameter PVC

(4x2.5+1x2.5 mm²) UG supply line from MDB to LPP-B in 50mm diameter

PVC

(2x6+1x6 mm²) UG supply line from MDB to LPP-D in

50mm diameter PVC

(4x2.5+1x2.5 mm²) supply line from MDB to LPP-C in

50mm diameter PVC in ceiling

EL-006

S

IT

E

EL

EC

TR

IC

A

L P

LA

N

SITE ELECTRICAL PLAN

1:150

5 0 5 10

BT BT

TE

TR

A

T

EC

H

/0

5/

U S A

ID

E

TH

IO

P

IA

H

EA

LT

H

IN

FR

A S

TR

U C

TU

R E

P R O

G R A

M

KM

D

ES

IG

N

ED

B

Y

D R A

W N

B Y

C H

K B

Y

D A

TE

S U

B M

IT

TE

D B

Y

D A

TE

A

PR

SY

M B

NOTE: A3 SIZE REDUCED TO HALF SCALE

RENOVATION

(WAKA)

SITE # 213

W A

K A

H

EA

LT

H

C

EN

TE

R

R

EN

O V

A

TI

O N

S

IT

E N

O

D

ES

C

RI

PT

IO

N

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

/1 4/

/0

5/

0%

D

ES

IG

N

D

EV

EL

O

PM

EN

T D

W G s

R

FI

FIN GRADE

WARNING TAPE

200 200

PVC PIPE Ø 50MM

SOIL BACK FILL

POWER CABLE IN

PVC PIPE Ø 50MM

FIN GRADE

WARNING TAPE

SOIL BACK FILL

200 200

POWER CABLE IN

PVC PIPE Ø 50MM,

TYP

FIN GRADE

WARNING TAPE

100 200

SOIL BACK FILL

POWER CABLE IN

PVC PIPE Ø 50MM,

TYP

FIN GRADE

WARNING TAPE

70 130

SOIL BACK FILL

70130

EARTHING ROD: COPPER CLAD

STEEL DIA 16MM, L 2400MM

EARTHING CONDUCTOR TO

MDB; SIZE PER DWGS

NOTE:

1. EARTHING RESISTANCE SHALL NOT BE GREATER THAN 5 OHM.

2. IF EARTHING RESISTANCE IS GREATER THAN 5 OHM, ADDITIONAL

ELECTRODE SHALL BE BURIED, SPACED NOT LESS THAN THE LENGTH OF

THE ELECTRODE.

Ø16 STL BAR HANDLE

100MM RC COVER

Ø8 C/C 120 BOTH WAYS

Ø8 C/C 120 BOTH WAYS

5 10 50 510

100 500 100

FIN GRADE SLOPED 2%

FROM MH

700X700X700MM RC

MANHOLE

Ø16 STL BAR HANDLE

100MM RC COVER

Ø8 C/C 120 BOTH WAYS

Ø8 C/C 120 BOTH WAYS

5 10 40 510

100 400 100

FIN GRADE SLOPED 2%

FROM MH

600X600X600MM RC

MANHOLE

T Y

P

S

I T

E

E

L E

C

D

E T

A I L

S

EX-501

TYP EARTHING MANHOLE DETAIL9

SCALE: 1:75

STANDARD

DETAIL BOOK

w w w t e t r a t e c h c o m

O n e

G r a n t

S t r e e t

F r a m i n g h a m

M

A

P

M

P

D

O C

S S

I T

E S

R

E N

O V

A T

I O

N S

R

E N

O V

A T

I O

N

S

T A

N D

A R

D

D

E T

A I L

B

O O

K S

H E

E T

F I L

E S

E

H I P

E

X

E

L E

C D

T L

S N

E W

D

W G

M

A S

O N

K

E R

R Y

ONE PIPE

UG CABLE INSTALLATION DETAIL1

SCALE: 1:10

ONE PIPE/CABLE

UG CABLE INSTALLATION DETAIL2

SCALE: 1:10

TWO PIPE/CABLE

UG CABLE INSTALLATION DETAIL3

SCALE: 1:10

THREE PIPE/CABLE

UG CABLE INSTALLATION DETAIL4

SCALE: 1:10

TYP ELEC MANHOLE DETAIL10

SCALE: 1:75

BELOW GRADE:

50MM DIA PVC

PIPE

ABOVE GRADE:

50MM DIA

WEATHERPROOF

UPVC PIPE

GALV METAL

BRACKET WITH

CONC ANCHORS

SPACED 1M OC

AND AT ALL

TURNS &

JUNCTURES, TYP

TO BLDG

INTERIOR

ELEC

INSTALLATION

SUB OR MAIN DIST

BOARD

EXST EXT WALL

EXST VERANDAH

EXST SOFFIT

50MM DIA

WEATHERPROOF

UPVC PIPE ATTACHED

WITH GALV METAL

BRACKETS W/ CONC

ANCHORS SPACED 1

M OC TO OTHER

BLOCKS WHERE REQ

BELOW GRADE:

50MM DIA PVC PIPE

ABOVE GRADE:

50MM DIA

WEATHERPROOF

UPVC PIPE

GALV METAL

BRACKET WITH

CONC ANCHORS

SPACED MAX 1M

OC

EXST SOFFIT

EXST EXT WALL

SUB OR MAIN DIST

BOARD

T Y

P

S

I T

E

E

L E

C

D

E T

A I L

S

EX-502

STANDARD

DETAIL BOOK

w w w t e t r a t e c h c o m

O n e

G r a n t

S t r e e t

F r a m i n g h a m

M

A

P

M

P

D

O C

S S

I T

E S

R

E N

O V

A T

I O

N S

R

E N

O V

A T

I O

N

S

T A

N D

A R

D

D

E T

A I L

B

O O

K S

H E

E T

F I L

E S

E

H I P

E

X

E

L E

C D

T L

S N

E W

D

W G

M

A S

O N

K

E R

R Y

ABOVE GRADE ELEC CONDUIT

INSTALLATION DETAIL AT VERANDAH5

SCALE: 1:10

ABOVE GRADE ELEC CONDUIT

INSTALLATION DETAIL AT EXT WALL6

SCALE: 1:10

File details come from the government source that posted it. Updated .