PDX 2026-501 (223) E4.13.pdf
PDF 354 KB Posted
- Solicitation number
- 147231
- Issued by
- Multnomah County, Oregon
About this file
This is an electrical wiring diagram for the Portland International Airport North Runway Rehabilitation project, a capital improvement initiative by Portland International Airport (PDX) in Oregon. The document details the Taxiway K1 Stop Bar wiring system and specifies the reinstallation and installation of various lighting and electrical components. The scope includes reinstalling LED red elevated stop bar lights with existing single-channel remotes and new 45-watt isolation transformers (2 units at Taxiway K1), providing and installing new 100-watt isolation transformers for in-pavement stop bar lights and remotes (10 units), reinstalling LED centerline lights with existing remotes and new 65-watt isolation transformers (27 units at Taxiway K1), and reinstalling dual LED in-pavement stop bar/non-autonomous runway guard lights with new 100-watt isolation transformers. Additional work includes providing and installing new 200-watt isolation transformers, reinstalling microwave sensors with utility remote enclosure assemblies per ADB instructions, and reinstalling elevated runway guard lights (2 units at Taxiway K1). The drawing is dated October 2026 and was prepared by design firm personnel including Gene Tupper, M. Tieaskie, M. Dettmer, and Professional Engineer Jeffery L. Nelson (PE #15521, expiration 12/31/2026).
The diagram serves as a technical specification sheet with a comprehensive legend identifying various lighting components including red stop bar lights, centerline lights, guard lights, microwave sensors, remote controls with specific channel configurations, and isolation transformers. The wiring schematic illustrates the electrical connections and control systems necessary for the taxiway lighting infrastructure. No pricing information, bid dates, contract award dates, funding sources, or set-aside information is contained within this technical drawing document.
View the file
Other files
Show 40 more
Latest 50 of 308 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R Y R Y R Y R Y R Y R Y R Y R Y R Y
RS2(ON)
RE1
10L-28R WW
IPSB-K1-1
REINSTALL LED RED ELEVATED STOP BAR LIGHT
WITH EXISTING SINGLE CHANNEL REMOTE AND
NEW CF 45-W, 6.6/6.6 AMP ISOLATION
TRANSFORMER (TYP. OF 2 AT TAXIWAY K1)
RS2(OFF)REM
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S G
R S
G R
S
10L BRT
MWS-K1-2
PROVIDE AND INSTALL NEW CF 100-WATT,
6.6/6.6 AMP ISOLATION TRANSFORMER
(TYP. OF 10 FOR IN-PAVEMENT STOP BAR
LIGHTS AND REMOTES)
REINSTALL EXISTING DUAL
CHANNEL REMOTE (TYP.)
10L BRT
TCK1-26
TCK1-25
TCK1-24
TCK1-23
TCK1-22
TCK1-21
TCK1-20
TCK1-19
TCK1-18
TCK1-17
TCK1-16
TCK1-15
TCK1-14
TCK1-13
TCK1-12
TCK1-11
TCK1-10
TCK1-9
TCK1-8
TCK1-7
TCK1-6
TCK1-5
TCK1-4
TCK1-3
TCK1-2
TCK1-1
MWS-K1-1
REINSTALL PF LED CENTERLINE
LIGHT WITH EXISTING REMOTE
AND NEW CF 65-WATT, 6.6/6.6
AMP ISOLATION TRANSFORMER
(TYP. OF 27 AT TAXIWAY K1)
IPSB-K1-2 IPSB-K1-3 IPSB-K1-4 IPSB-K1-5 IPSB-K1-6 IPSB-K1-7 IPSB-K1-8 IPSB-K1-9 IPSB-K1-10
G R
STCK1-27
ELSBL-K1-1 ELSBL-K1-2
REINSTALL AGC UTILITY
REMOTE ENCLOSURE
ASSEMBLY. SEE DETAIL
REINSTALL PF AGC UTILITY
REMOTE ENCLOSURE
ASSEMBLY. SEE DETAIL
REINSTALL NEW DUAL LED IN-PAVEMENT STOP BAR/
NON-AUTONOMOUS RGL WITH NEW CF 100-WALT,
6.6/6.6 AMP ISOLATION TRANSFORMER (TYP).
REINSTALL PF SINGLE CHANNEL REMOTE (TYP.)
ON OFF ON OFF ON OFF ON OFF ON OFF
ON
RS2(ON) RS2(OFF) RS2(ON) RS2(OFF) RS2(ON) RS2(OFF) RS2(ON) RS2(OFF)
PROVIDE AND INSTALL NEW CF 100-WATT
6.6/6.6 AMP ISOLATION TRANSFORMER.
CONNECT ISOLATION TRANSFORMER,
UTILITY REMOTE ENCLOSURE ASSEMBLY
AND SENSOR PER ADB'S INSTRUCTION.
MWS
REINSTALL PF MICROWAVE SENSOR.
PROVIDE AND INSTALL NEW CF
100-WATT 6.6/6.6 AMP ISOLATION
TRANSFORMER. CONNECT ISOLATION
TRANSFORMER,UTILITY REMOTE
ENCLOSURE ASSEMBLY AND SENSOR
PER ADB'S INSTRUCTION.
REINSTALL MICROWAVE SENSOR.
REINSTALL ELEVATED RUNWAY GUARD
LIGHT (TYP. OF 2 AT TAXIWAY K1)
R Y
RE2
REM
G R
S
M W
S
E5.10
E5.10
PROVIDE AND INSTALL NEW CF
200-WATT, 6.6/66 AMP ISOLATION
TRANSFORMER
PROVIDE AND INSTALL NEW CF
200-WATT, 6.6/66 AMP ISOLATION
TRANSFORMER
JUL Y 2 5 , 1991
JEFFERY L. NELSON
EXP: 12/31/2026
ENGINEER
RE
GIS
TERED PROFESSIONAL
OREGON
15521PE
SCALE:
TAXIWAY K1 STOP BAR WIRING DIAGRAM
N.T.S.1
10/7/2026
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
AL
L
TH
R
EE
P
LA
N
ES
A
R E
VI
SI
BL
E.
T H
IS
G
U
ID
AN
C
E
IS
P R
O
VI
D
ED
F O
R R
EF
ER
EN
C
E O
N
LY
PRINTED:
lig ht da rk gr ay bl ac k
DESIGN NUMBER PROJECT NUMBER
2"
G R
AP
H
IC
S
C
AL
E
- F
O R
R
EF
ER
EN
C E
O N
LY
gr ay
12:29:09 PM DETTMM r:\aviation\pdx\2026\0501 - pdx north runway rehab\sheets - electrical\stop bar wiring diagrams.dwg
DISC. SHT. NO.
DESIGN BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
SUBMITTED BY
DRAWING NO.
TYPE:
1/
4" 1/
2" 1"
1/
4" 1/
2" 1"
DATE BY REVISION APPDATE BY REVISION APP ##
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING DRAWING SCALE IS REDUCED 50� WHEN SHEET SIZE IS 11" x 17"
PORTLAND INTERNATIONAL AIRPORT
NORTH RUNWAY REHABILITATION
ELECTRICAL LIGHTING PLAN
TAXIWAY K1 STOP BAR WIRING DIAGRAM
GENE TUPPER
M. TIEASKIE
M. DETTMER
J. NELSON
OCTOBER 2026
223 CD
PDX 2026-501 E4.132024D011 102981
R Y
REM
GRS
MWS
RS2 (OFF)
RS2 (ON)
RE
R
ON
Y
OFF
LEGEND:
RED STOP BAR LIGHT DUAL CHANNEL REMOTE WITH A
CHANNEL "A" INITIAL FLASH ON (PF)
RED STOP BAR LIGHT DUAL CHANNEL REMOTE WITH A
CHANNEL "A" INITIAL FLASH ON (PF)
RED STOP BAR LIGHT SINGLE CHANNEL REMOTE (PF)
TAXIWAY CENTERLINE LIGHT SINGLE CHANNEL
REMOTE (PF)
MICROWAVE SENSOR SINGLE CHANNEL REMOTE (PF)
RED ELEVATED STOP BAR LIGHT (PF)
SINGLE CHANNEL REMOTE WITH A CHANNEL "A" INITIAL
FLASH ON (PF)
SINGLE CHANNEL REMOTE WITH A CHANNEL "A" INITIAL
FLASH OFF (PF)
TAXIWAY CENTERLINE LIGHT (PF)
MICROWAVE SENSOR (PF)
RED AND YELLOW FLUSH STOP BAR/GUARD LIGHT (PF)
RED FLUSH STOP BAR LIGHT (PF)
YELLOW FLUSH GUARD LIGHT (PF)
ISOLATION TRANSFORMER (PF)
ELEVATED RUNWAY GUARD LIGHT (PF)
ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com ftp://portstds:UseStandards@ftp.pi-express.com
| DIGITALLY SIGNED | |
| 2026-10-08T09:14:08-0700 | |
| Jeff Nelson |
File details come from the government source that posted it. Updated .