PDX 2026-501 (158) C9.07.pdf

PDF 957 KB Posted

Attached to
Portland International Airport North Runway Rehabilitation
Solicitation number
147231
Issued by
Multnomah County, Oregon

About this file

This is a technical specification document for the Portland International Airport North Runway Rehabilitation project in Oregon, specifically detailing storm drainage and manhole construction requirements. The document provides comprehensive specifications for Type B precast storm sewer manholes, including design standards, materials, installation procedures, and safety requirements. All precast sections must conform to ASTM C-478, with reinforcement meeting ASTM A615 Grade rebar or ASTM A497 welded wire specifications. Manholes are designed to accommodate 100,000-pound wheel loads with 250 PSI tire pressure and require shop drawings and structural calculations stamped by a licensed Oregon structural engineer. Backfill around structures within new or existing pavements or within 10 feet of pavement must utilize Controlled Low Strength Material (CLSM), while other areas follow standard specifications. The project requires installation of PORT-furnished confined space signage on all new and existing unsigned confined space structures within the project area, with designated identification numbers applied using permanent markers and powder-actuated fastening tools.

The specifications include detailed attachment procedures for confined space signs using Hilti powder-actuated guns with varying fastener options and charge settings depending on substrate material (concrete, hard cast iron, or brittle concrete). Manhole frames and covers must be ductile iron with bolted covers and aircraft-rated grates to meet the airport's operational requirements. Manhole access steps and lid openings must conform to OSHA standards (sections 1910.23(D) and 1910.24(B)), with steps spaced at 12-inch centers conforming to City of Portland Standard Plan P-168. The document was prepared by HNTB Corporation and dated October 2026, with design oversight from registered professional engineer Hans N. Conradt (License PE 60434, expiring December 31, 2027). No pricing, contract duration, or award information is contained within this technical specification document.

View the file

Other files

File Type Posted
PDX 2026-501 (277) E7.14.pdf PDF
PDX 2026-501 (236) E5.04.pdf PDF
PDX 2026-501 (107) C7.01.pdf PDF
PDX 2026-501 (162) C9.11.pdf PDF
PDX 2026-501 (18) C1.10.pdf PDF
PDX 2026-501 (263) E6.13.pdf PDF
PDX 2026-501 (53) C4.06.pdf PDF
PDX 2026-501 (254) E6.04.pdf PDF
PDX 2026-501 (102) C6.08.pdf PDF
PDX 2026-501 (151) C9.00.pdf PDF
PDX 2026-501 (156) C9.05.pdf PDF
PDX 2026-501 (130) C7.24.pdf PDF
PDX 2026-501 (174) C10.11.pdf PDF
Getting the most out of your Port of Portland Vendor Profile.docx DOCX document
PDX 2026-501 (202) E3.05.pdf PDF
PDX 2026-501 (195) E2.11.pdf PDF
PDX 2026-501 (66) C4.19.pdf PDF
PDX 2026-501 (299) E8.21.pdf PDF
PDX 2026-501 (160) C9.09.pdf PDF
PDX 2026-501 (133) C7.27.pdf PDF
PDX 2026-501 (16) C1.08.pdf PDF
PDX 2026-501 (52) C4.05.pdf PDF
PDX 2026-501 (41) C3.15.pdf PDF
PDX 2026-501 (89) C5.14.pdf PDF
PDX 2026-501 (227) E4.17.pdf PDF
PDX 2026-501 (212) E4.02.pdf PDF
PDX 2026-501 (33) C3.07.pdf PDF
PDX 2026-501 (274) E7.11.pdf PDF
PDX 2026-501 (205) E3.08.pdf PDF
PDX 2026-501 (181) C12.02.pdf PDF
PDX 2026-501 (228) E4.18.pdf PDF
PDX 2026-501 (197) E3.00.pdf PDF
PDX 2026-501 (278) E7.15.pdf PDF
PDX 2026-501 (173) C10.10.pdf PDF
2026-14659 Project Manual.pdf PDF
PDX 2026-501 (137) C7.31.pdf PDF
PDX 2026-501 (211) E4.01.pdf PDF
PDX 2026-501 (10) C1.02.pdf PDF
PDX 2026-501 (144) C8.02.pdf PDF
PDX 2026-501 (159) C9.08.pdf PDF
PDX 2026-501 (237) E5.05.pdf PDF
PDX 2026-501 (106) C7.00.pdf PDF
PDX 2026-501 (97) C6.03.pdf PDF
PDX 2026-501 (256) E6.06.pdf PDF
PDX 2026-501 (191) E2.07.pdf PDF
PDX 2026-501 (140) C7.34.pdf PDF
PDX 2026-501 (135) C7.29.pdf PDF
PDX 2026-501 (186) E2.02.pdf PDF
PDX 2026-501 (207) E3.10.pdf PDF
PDX 2026-501 (249) E5.17.pdf PDF
Show 40 more

Latest 50 of 308 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. ALL PRECAST SECTIONS SHALL CONFORM TO REQUIREMENTS OF ASTM C-478.

2. REINFORCEMENT SHALL BE REBAR MEETING ASTM A615 GRADE OR WELDED WIRE MEETING ASTM A497.

3. INSTALL PORT FURNISHED CONFINED SPACE SIGNS IN ALL STRUCTURES, SEE DETAIL

4. BACKFILL AROUND STRUCTURES WITHIN NEW OR EXISTING PAVEMENTS OR WITHIN 10' OF ANY PAVEMENT SHALL BE CONTROLLED LOW STRENGTH MATERIAL (CLSM). BACKFILL AROUND ALL OTHER STRUCTURES

SHALL BE PER THE SPECIFICATIONS.

GENERAL NOTES:

13" CC

INSIDE OF

MANHOLE

WALL

3" M

IN

- 1

/2 " M

IN

13 - 1/2"

14 - 1/4"

NOTE:

1. MANHOLE STEPS SHALL CONFORM TO CITY

OF PORTLAND STANDARD PLAN P-168.

NOTES:

1. CONFINED SPACE SIGNAGE IS TO BE ATTACHED TO PORT IDENTIFIED NEW CONFINED SPACE STRUCTURES AND EXISTING

UNSIGNED CONFINED SPACE STRUCTURES WITHIN THE PROJECT AREA.

2. WRITE THE DESIGNATED CONFINED SPACE IDENTIFICATION NUMBER ON THE PORT PROVIDED SIGN (SPACE ID) USING A PERMANENT MARKER IN A CLEAR, LEGIBLE MANNER, PORT WILL PROVIDE NUMBER FOR EACH SPACE.

3. PERMANENTLY ATTACH THE SIGN TO THE CONFINED SPACE IN THE MANNER SPECIFIED IN THE TABLE (BASED ON MATERIAL)

ATTACHING CONFINED SPACE SIGNS

TOOL: HILTI POWDER ACTUATED GUN, MODEL DX 36 M

MATRIX BEING ATTACHED

TO

FASTENER CHARGE CHARGE SETTING NOTES

CONCRETE X-DAK 16P8 WITH

R-23 WASHER

YELLOW (50352/4) DIALED TO THE

ABSOLUTE

MINIMUM

THIS WORKS WELL BECAUSE OF THE SHARP,

SHORT FASTENER. IF THIS DOES NOT WORK, TRY

THE NEXT CONCRETE SUGGESTION BELOW.

CONCRETE X-DNI 27P8S15 YELLOW (50352/4) DIALED FROM

ABSOLUTE

MINIMUM TO .5

THIS FASTENER COMES WITH A SMALL WASHER

ALREADY ATTACHED. IF THIS BLOWS THROUGH

THE SIGN YOU SHOULD USE A R-23 WASHER.

OLD CONCRETE - HARD

CAST IRON

NO SUGGESTION THESE ARE VERY TOUGH TO ATTACH TO. WITH

THE HARD CAST IRON TRY 2-4 TIMES AND IF IT

DOES NOT ATTACH, GO FOR THE CONCRETE

BELOW THE RING. FOR THE OLD BRITTLE

CONCRETE TRY ALL THREE FASTENERS, ONLY

OCCASIONALLY THEY ARE UNSUCCESSFUL.

C9.07

VA

R

IA

BL

E

VA

R

IA

BL

E

VARIES

M

IN

MANHOLE

RINGS

3" M

IN

THE MANHOLE MAY

POURED MONOLITHIC TO

8" ABOVE THE BARREL

OF THE MAIN SEWER

PRECAST TOP SLAB

PRECAST RISER

6" MIN/16" MAX

30"

ANCHOR FRAME TO MANHOLE

STRUCTURE WITH 4 - 3/4" x 12"

LONG EXPANSION ANCHORS

" M

AX

MANHOLE FRAME AND

COVER, SEE NOTE 2

RUBBER GASKET

TYPICAL ALL JOINTS

BREAK OUT 2" CLEAR (MIN.)

STEPS @ 12" O.C.

SEE DETAIL 2

C9.07

6" 6"

12" MIN

CRUSHED AGG. BASE COURSE

(P-209) - COMPACT TO 95% AS

DETERMINED BY ASTM D1557

VA

R

IE

S

NOTES:

1. TYPE B MANHOLES SHALL BE PRECAST AND DESIGNED FOR LOADING

OF 100,000 LBS. (100 KIPS) AND 250 PSI. THE CONTRACTOR SHALL

SUBMIT SHOP DRAWINGS AND STRUCTURAL CALCULATIONS STAMPED

BY A LICENSED STRUCTURAL ENGINEER IN THE STATE OF OREGON FOR

APPROVAL.

2. MANHOLE FRAME AND COVER SHALL BE DUCTILE IRON & DESIGNED TO

MEET 100,000 LB, WHEEL LOADS WITH 250 PSI TIRE PRESSURE. COVER

SHALL BE BOLTED TO FRAME. MANHOLE CATCH BASIN GRATE SHALL BE

AIRCRAFT RATED.

3. BACKFILL AROUND STRUCTURES WITHIN NEW OR EXISTING

PAVEMENTS OR WITHIN 10' OF ANY PAVEMENT SHALL BE CONTROLLED

LOW STRENGTH MATERIAL (CLSM). BACKFILL AROUND ALL OTHER

STRUCTURES SHALL BE PER THE SPECIFICATIONS.

4. MANHOLE ACCESS STEPS AND LID OPENING SHALL CONFORM TO

APPLICABLE STANDARDS FOR DIMENSIONS AND CLEARANCES,

PARTICULARLY OSHA SECTIONS 1910.23(D) AND 1910.24(B). SEE DETAIL

C9.07

10/6/2026

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

AL

L

TH

R

EE

P

LA

N

ES

A

R E

VI

SI

BL

E.

T H

IS

G

U

ID

AN

C

E

IS

P R

O

VI

D

ED

F O

R R

EF

ER

EN

C

E O

N

LY

PRINTED:

lig ht da rk gr ay bl ac k

DESIGN NUMBER PROJECT NUMBER

2"

G R

AP

H

IC

S

C

AL

E

- F

O R

R

EF

ER

EN

C E

O N

LY

gr ay

1:49:40 PM NCHOWDHURY c:\users\nchowdhury\dc\accdocs\hntb corporation\88598 - pdx north runway rehab\project files\shared cad\sheets - civil\storm drainage details.dwg

DISC. SHT. NO.

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"

DESIGN BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

SUBMITTED BY

DRAWING NO.

TYPE:

1/

4" 1/

2" 1"

1/

4" 1/

2" 1"

DATE BY REVISION APPDATE BY REVISION APP ##

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

PORTLAND INTERNATIONAL AIRPORT

NORTH RUNWAY REHABILITATION

STORM DRAINAGE AND UNDERDRAIN DETAILS 1

GENE TUPPER

C. EISELER

N. CHOWDHURY

H. CONRADT

OCTOBER 2026

158 CD

PDX 2026-501 C9.072024D011 102981

SCALE:

STORM SEWER MANHOLE TYPE "B"

AIRCRAFT RATED

N.T.S.1

SCALE:

MANHOLE STEP

N.T.S.2 SCALE:

CONFINED SPACE SIGN

N.T.S.3

RE

G ISTERED PROFESS IONALENG I NEER

MARCH 9 , 1999

60434PE

OREGON

12/31/27EXPIRES:

HA NS N . CONRA DT

2026-10-06T17:38:00-0700
Hans N Conradt

File details come from the government source that posted it. Updated .