PDX 2026-501 (162) C9.11.pdf

PDF 391 KB Posted

Attached to
Portland International Airport North Runway Rehabilitation
Solicitation number
147231
Issued by
Multnomah County, Oregon

About this file

This document is a technical specification sheet for storm drainage and underdrain details prepared for the Portland International Airport North Runway Rehabilitation project in Oregon. The sheet, dated October 2026 and designated as drawing number PDX 2026-501 C9.11, provides detailed construction specifications for utility locate procedures, underdrain cleanout installations, and related drainage infrastructure. Key specifications include 6-inch HDPE perforated and non-perforated underdrain pipes with 45-degree elbows and wye connections, controlled low strength material (CLSM) encasement requirements, utility locate wire installation within one foot of openings, and porous backfill with filter fabric applications. The cleanout cover assembly utilizes either a Neenah R-6014 frame with 14-inch diameter opening or an approved equal, stamped with "UNDERDRAIN" lettering and bolted to the frame. Installation requirements mandate that disturbed areas be seeded and topsoiled, that the cleanout assembly be installed after hot mix asphalt surface course construction through coring or sawcutting, and that concrete encasement extend to the bottom of the crushed aggregate base course.

The technical specifications establish contractor options for either square or round concrete underdrain cleanout casting pads with minimum diameter of 1 foot 6 inches, subject to engineer review and approval for round configurations. Stabilization of vertical cleanouts is required to prevent pipe damage or movement, and controlled low strength material must not contact perforated underdrain pipe sections. The design was prepared by Gene Tupper and H. Conradt, with drawings checked by C. Eiseler and N. Chowdhury. All specifications reference standard material grades including structural concrete (P-610), porous backfill (D-705), filter fabric, and fiber joint packing components. The document confirms compliance with Oregon Professional Engineer registration requirements and includes a note regarding optimal viewing settings for print and electronic display of the technical drawings at various shading levels.

View the file

Other files

File Type Posted
PDX 2026-501 (277) E7.14.pdf PDF
PDX 2026-501 (236) E5.04.pdf PDF
PDX 2026-501 (107) C7.01.pdf PDF
PDX 2026-501 (18) C1.10.pdf PDF
PDX 2026-501 (263) E6.13.pdf PDF
PDX 2026-501 (53) C4.06.pdf PDF
PDX 2026-501 (254) E6.04.pdf PDF
PDX 2026-501 (102) C6.08.pdf PDF
PDX 2026-501 (151) C9.00.pdf PDF
PDX 2026-501 (156) C9.05.pdf PDF
PDX 2026-501 (130) C7.24.pdf PDF
PDX 2026-501 (174) C10.11.pdf PDF
Getting the most out of your Port of Portland Vendor Profile.docx DOCX document
PDX 2026-501 (202) E3.05.pdf PDF
PDX 2026-501 (195) E2.11.pdf PDF
PDX 2026-501 (66) C4.19.pdf PDF
PDX 2026-501 (299) E8.21.pdf PDF
PDX 2026-501 (160) C9.09.pdf PDF
PDX 2026-501 (133) C7.27.pdf PDF
PDX 2026-501 (16) C1.08.pdf PDF
PDX 2026-501 (52) C4.05.pdf PDF
PDX 2026-501 (41) C3.15.pdf PDF
PDX 2026-501 (89) C5.14.pdf PDF
PDX 2026-501 (227) E4.17.pdf PDF
PDX 2026-501 (212) E4.02.pdf PDF
PDX 2026-501 (33) C3.07.pdf PDF
PDX 2026-501 (274) E7.11.pdf PDF
PDX 2026-501 (205) E3.08.pdf PDF
PDX 2026-501 (181) C12.02.pdf PDF
PDX 2026-501 (228) E4.18.pdf PDF
PDX 2026-501 (197) E3.00.pdf PDF
PDX 2026-501 (158) C9.07.pdf PDF
PDX 2026-501 (278) E7.15.pdf PDF
PDX 2026-501 (173) C10.10.pdf PDF
2026-14659 Project Manual.pdf PDF
PDX 2026-501 (137) C7.31.pdf PDF
PDX 2026-501 (211) E4.01.pdf PDF
PDX 2026-501 (10) C1.02.pdf PDF
PDX 2026-501 (144) C8.02.pdf PDF
PDX 2026-501 (159) C9.08.pdf PDF
PDX 2026-501 (237) E5.05.pdf PDF
PDX 2026-501 (106) C7.00.pdf PDF
PDX 2026-501 (97) C6.03.pdf PDF
PDX 2026-501 (256) E6.06.pdf PDF
PDX 2026-501 (191) E2.07.pdf PDF
PDX 2026-501 (140) C7.34.pdf PDF
PDX 2026-501 (135) C7.29.pdf PDF
PDX 2026-501 (186) E2.02.pdf PDF
PDX 2026-501 (207) E3.10.pdf PDF
PDX 2026-501 (249) E5.17.pdf PDF
Show 40 more

Latest 50 of 308 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POROUS

BACKFILL

(D-705)

UTILITY (PIPE, DUCT, ETC.)

GRADE

NOTE:

1. LOCATE COIL WITHIN ONE FOOT OF OPENING. LABEL "LOCATE"

WARNING TAPE

10 GAUGE XHHW COPPER

STRANDED LOCATE WIRE.

WIRE TO BE BROUGHT OVER

CENTERLINE OF PIPE

FASTEN WIRE

AS REQUIRED

2' COIL AND UTILITY

LOCATE WIRE TAG

2' COIL

1' -0

LOCATE

PLAN

3"

3"

STRUCTURAL

CONCRETE (P-610)

FRAME

2 - #4X1'-2" E.W.

1 - #4 HOOP

1' -6

1'-6"

3" (T

YP

2 - #4X1'-2" E.W.

1 - #4 HOOP 14" DIA

WITH 1'-6" LAP

NEENAH R-6014 FRAME AND COVER

OR EQUAL. COVER TO BE STAMPED

WITH 1-INCH SURFACE LETTERING

WITH THE WORD "UNDERDRAIN."

COVER SHALL BOLT TO FRAME.

NOTES:

1. STABILIZE VERTICAL CLEANOUT TO PREVENT PIPE DAMAGE OR MOVEMENT.

2. CONTROLLED LOW STRENGTH MATERIAL SHALL ENCASE ALL JOINT ELBOWS AND WYES.

3. CONTROLLED LOW STRENGTH MATERIAL SHALL NOT BE IN CONTACT WITH PERFORATED

UNDERDRAIN PIPE.

4. ALL DISTURBED AREAS SHALL BE SEEDED (T-901) AND TOPSOILED (T-905).

5. SEE NOTE 2, DETAIL 2 THIS SHEET FOR UNDERDRAIN CLEANOUT INSTALLATION

INFORMATION.

NOTES:

1. CONTRACTOR HAS THE OPTION TO INSTALL A ROUND CONCRETE UNDERDRAIN CLEANOUT CASTING PAD IN LIEU OF THE SQUARE PAD SHOWN. THE CONTRACTOR SHALL SUBMIT A PROPOSED DETAIL FOR A ROUND FOR A ROUND FOR REVIEW AND APPROVAL BY ENGINEER. MINIMUM PAD DIAMETER

SHALL BE 1'-6".

2. THE UNDERDRAIN CLEANOUT COVER, FRAME AND CONCRETE PAD INSTALLATION SHALL OCCUR AFTER THE P-401 HOT MIX ASPHALT SURFACE COURSE CONSTRUCTION. CONTRACTOR SHALL CORE OR SAWCUT THE ASPHALT TO INSTALL THE UNDERDRAIN CLEANOUT. THE UNDERDRAIN CLEANOUT

SHALL BE CONCRETE ENCASED TO THE BOTTOM OF THE CRUSHED AGGREGATE BASE COURSE.

CENTER OF

CLEANOUT

(LOCATION POINT)

6" SOLID

PIPE (TYP.)

VARIES

6" HDPE PERFORATED

PIPE (TYP.)

45° BEND

6" SOLID PIPE (TYP.)

6" NON-PERFORATED

UNDERDRAIN PIPE

FLOW

POROUS

BACKFILL

(D-705)

FILTER FABRIC

(D-705)

D

EP

TH

V

AR

IE

S

6" PERFORATED

UNDERDRAIN PIPE

6" NON-PERFORATED

UNDERDRAIN PIPE

6" NON-PERFORATED

UNDERDRAIN PIPE

CLSM (P-153)

45° ELBOW

45° ELBOW INVERT ELEVATION

AS SHOWN ON

PROFILE

FLOW

45° WYE COUPLING

6" PERFORATED

UNDERDRAIN PIPE

C9.11

INSTALL IN AC PAVEMENT SECTION OR IN

NON-PAVED GRADED AREA

SEE PLAN VIEW FOR PLACEMENT

LOCKING RING & COVER

OLYMPIC FOUNDRY M1007 D/T

OR APPROVED EQUAL. COVER

SHALL BE TAMPERPROOF,

BOLTED OR SCREWED TO RING.

FIBER JOINT PACKING

8" DIA

4 3/4"

10/6/2026

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

AL

L

TH

R

EE

P

LA

N

ES

A

R E

VI

SI

BL

E.

T H

IS

G

U

ID

AN

C

E

IS

P R

O

VI

D

ED

F O

R R

EF

ER

EN

C

E O

N

LY

PRINTED:

lig ht da rk gr ay bl ac k

DESIGN NUMBER PROJECT NUMBER

2"

G R

AP

H

IC

S

C

AL

E

- F

O R

R

EF

ER

EN

C E

O N

LY

gr ay

1:49:45 PM NCHOWDHURY c:\users\nchowdhury\dc\accdocs\hntb corporation\88598 - pdx north runway rehab\project files\shared cad\sheets - civil\storm drainage details.dwg

DISC. SHT. NO.

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"

DESIGN BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

SUBMITTED BY

DRAWING NO.

TYPE:

1/

4" 1/

2" 1"

1/

4" 1/

2" 1"

DATE BY REVISION APPDATE BY REVISION APP ##

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

PORTLAND INTERNATIONAL AIRPORT

NORTH RUNWAY REHABILITATION

STORM DRAINAGE AND UNDERDRAIN DETAILS 5

GENE TUPPER

C. EISELER

N. CHOWDHURY

H. CONRADT

OCTOBER 2026

162 CD

PDX 2026-501 C9.112024D011 102981

SCALE:

TYPICAL 6" CLEAN-OUT

N.T.S.1

SCALE:

TYPICAL UTILITY LOCATE

AT CLEANOUT DETAIL

N.T.S.2

SCALE:

CLEANOUT "Y" CONNECTION

N.T.S.3 SCALE:

UNDERDRAIN CLEANOUT

COVER AND CONCRETE PAD

N.T.S.4

RE

G ISTERED PROFESS IONALENG I NEER

MARCH 9 , 1999

60434PE

OREGON

12/31/27EXPIRES:

HA NS N . CONRA DT

2026-10-06T17:42:39-0700
Hans N Conradt

File details come from the government source that posted it. Updated .