S06 Att Amend 0002 GC101 - INFECTION CONTROL_PHASING PLAN.pdf

PDF 491 KB Posted

Attached to
Z2DA--Project # 695-19-131 Renovate and Expand Dialysis Clinic Clement J. Zablocki VA Medical Center Milwaukee, WI
Solicitation number
36C25220B0021
Issued by

About this file

This document provides details for a federal construction contract opportunity to renovate and expand a dialysis clinic at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The contract involves demolishing and reconstructing ward 7AS of building 111 to create a new 11,000 square foot dialysis clinic, including trades such as demolition, concrete, electrical, plumbing, mechanical, architectural work and specialty furnishings. Hazardous materials abatement is also required. The work will impact adjacent occupied and unoccupied areas. The solicitation is scheduled to post on May 13, 2020 with a bid opening of June 16, 2020. Pursuant to Public Law 109-461, this opportunity is set aside as a 100% Service Disabled Veteran Owned Small Business set-aside. Offerors must represent that they are an SDVOSB or VOSB at the time of submission, are a small business for the assigned NAICS code, and are verified on VetBiz.gov. The period of performance is 540 calendar days with a projected value of $2-5 million.

View the file

Other files

File Type Posted
Amend 0005 00 01 10 TABLE OF CONTENTS.pdf PDF
Amend 0005 22 67 19.16 REVERSE-OSMOSIS WATER EQUIPMENT.pdf PDF
Amend 0005 08 71 13.11 LOW ENERGY DOOR OPERATORS.pdf PDF
S06 36C25220B0021 0005.pdf PDF
Amend 0005 01 91 00 COMMISSIONING REQUIREMENTS.pdf PDF
Amend 0005 01 01 10 SN SPECIAL NOTES.pdf PDF
Amend 0005 11 73 00 CEILING MOUNT PATIENT LIFT.pdf PDF
Amend 0005 14 92 00 PNEUMATIC TUBE SYSTEM.pdf PDF
Amend 0003 Photos Revised.pdf PDF
S06 36C25220B0021 0004.pdf PDF
AI601 - FINISH SCHEDULES.pdf PDF
Wage Determination 6.19.20.pdf PDF
Amend 0003 Photos.pdf PDF
SECTION 10 21 23 - CUBICLE CURTAIN TRACKS.pdf PDF
36C25220B0021 0003.pdf PDF
S06 Att Amend 0002 00 01 10 - TABLE OF CONTENTS.pdf PDF
S06 Att Amend 0002 EP100 - BASEMENT FLOOR OVERALL PLAN.pdf PDF
S06 Att Amend 0002 AI201 - INTERIOR FINISHES ELEVATIONS.pdf PDF
S06 Att Amend 0002 AE601 - DOOR_WINDOW SCHEDULE.pdf PDF
S06 36C25220B0021 0002.pdf PDF
S06 Att Amend 0002 28 05 13 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY.pdf PDF
S06 Att Amend 0002 10 21 23 - CUBICLE CURTAIN TRACKS.pdf PDF
S06 Att Amend 0002 01 74 19 - CONSTRUCTION WASTE MANAGEMENT.pdf PDF
S06 Att Amend 0002 09 05 16 - FLOOR PREP1.pdf PDF
S06 Att Amend 0002 ET102 - SEVENTH FLOOR SYSTEMS PLAN - DIVISION 28.pdf PDF
S06 Att Amend 0002 AD101 - SEVENTH FLOOR DEMOLITION PLAN.pdf PDF
S06 Att Amend 0002 MD101 - MECHANICAL DEMOLITION FLOOR PLAN - 7TH FLOOR.pdf PDF
S06 Att Amend 0002 10 14 00 - SIGNAGE.pdf PDF
S06 Att Amend 0002 12 24 00 - WINDOW SHADES.pdf PDF
S06 Att Site Visit Sign In 5.28.20.pdf PDF
S06 Att Amend 0002 03 30 53 - CAST-IN-PLACE CONCRETE.pdf PDF
S06 Att Amend 0002 QH101 - SEVENTH FLOOR EQUIPMENT PLAN.pdf PDF
S06 Att Amend 0002 01 91 00 - COMMISSIONING REQUIREMENTS.pdf PDF
S06 Att Amend 0002 22 07 11 - PLUMBING INSULATION.pdf PDF
S06 Att Amend 0002 ET101D - SEVENTH FLOOR DEMOLITION PLAN.pdf PDF
S06 Att Amend 0002 22 11 00 - FACILITY WATER DISTRIBUTION.pdf PDF
S06 Att Amend 0002 AE501 - BUILDING DETAILS.pdf PDF
S06 Att Amend 0002 AI901 - SIGNAGE PLAN.pdf PDF
S06 Att Amend 0002 AI101 - FINISH WALL TREATMENT PLAN.pdf PDF
S06 Att Amend 0002 EP401 - ONE LINE DIAGRAM.pdf PDF
S06 Att Wage Determination 6.5.20.pdf PDF
Site Visit Sign In 5.20.20.pdf PDF
36C25220B0021 0001.docx DOCX document
Amend 0001 Specification 22 63 00.pdf PDF
Amend 0001 Specification 00 01 10.pdf PDF
Amend 0001 Specification 08 14 00.pdf PDF
Amend 0001 Specification 09 06 00.pdf PDF
Amend 0001 J_A Patient Ceiling Lift.pdf PDF
36C25220B0021-011.pdf PDF
36C25220B0021-012.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

TEMPORARY WALLS. SEE PLAN AND PLAN NOTES

TEMPORARY CONSTRUCTION ACCESS DOORS

REFERENCE AREA FOR ABOVE CEILING

WORK ON FLOOR BELOW.

RE: ENGINEERING DRAWINGS FOR FULL

SCOPE OF WORK

BEYOND PROJECT BOUNDARY

PROJECT BOUNDARY

IC / PHASING LEGEND

EXISTING WALL TO BE VERIFIED OR

MODIFIED TO BE 1-HR RATED

CONTINUOUS FIRESAFE SEALANT

TOP AND BOTTOM, & BOTH SIDES

3 1/2" SOUND ATTENUATION BATT.

5/8" TYPE X GYPSUM BOARD, BOTH SIDES

3 5/8" METAL STUD @ 16" O.C. WITH

RUNNER CHANNELS ALONG TOP

AND BOTTOM

CONSTRUCTION

SIDE

PUBLIC

SIDE

6 MIL. FIRE RETARDANT VISQUEEN

MEMBRANE. CONTINUOUSLY ADHERE

TO THE STRUCTURAL DECK ABOVE AND

TO THE FLOOR BELOW WITH TAPE.

UNDERSIDE OF STRUCTURAL DECK

UL LISTING: U465

COORDINATE WITH EXISTING CEILING

PUBLIC

SIDE

1 HOUR FIRE RATED METAL DOOR ASSEMBLY

AND FRAME WITH SEALS, CARD READER,

HARDWARE AND CLOSER.

TRIATEK MONITOR

SEAL ALL EDGES WITH TAPE. SEE

SPECIFICATIONS FOR MORE INFO.

SEAL ALL EDGES WITH TAPE

REFER TO TEMPORARY BARRIER TYPE FOR

REQUIRED CONDITION TO STRUCTURE ABOVE

VA / OSHA TEMPORARY SIGNAGE

LOCKSET TO ACCEPT VA SUPPLIED SFIC

CLOSER

NOTE: PROTECT EXISTING WALLS &

FLOORS FROM TEMP. CONSTRUCTION

BARRIER. EXISTING FINSIHES DAMAGED

BY TEMP. IC/CN BARRIER SHALL BE

REPAIRED BY CONTRACTOR.

PROVIDE CARD READER AT EXTERIOR ANTI-

ROOM DOOR ONLY.

CONSTRUCTION ACTIVITY - D

PATIENT RISK GROUP: MEDIUM

CLASS OF PRECAUTION MATRIX: IV

1. PROVIDE TEMPORARY 1 HR FIRE RATED WALL CONSTRUCTION PER NFPA

241. REFER TO DETAIL 1/GC101.

2. PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR WITH

CARD READER ACCESS. REFER TO DETAIL 2/GC101

3. WORK WILL TAKE PLACE ABOVE CEILING IN CORRIDOR C7B01 OUTSIDE OF

SCOPE BOUNDARY. CEILING WILL BE DEMOLISHED. NEW CEILING AND LIGHT

FIXTURES WILL BE REQUIRED. INSTALL NEW CEILING AND LIGHTS TO MATCH

EXISTING LAYOUT. REFER TO MECHANICAL DRAWINGS FOR SCOPE OF

WORK TO BE PERFORMED ABOVE CEILING. PATCH AND REPAIR FINISHES IN

THE CORRIDOR AS REQUIRED. PROVIDE INFECTION CONTROL PLAN TO COR

FOR APPROVAL PRIOR TO BEGINNING WORK. ALL WORK OUTSIDE OF

PROJECT BOUNDARY TO BE DONE OFF-SHIFT.

4. PROVIDE TEMPORARY INFECTION CONTROL BARRIER AT EXISTING STAIR

DOOR. THIS DOOR TO BE USED FOR EMERGENCY EGRESS ONLY.

REFERENCE VA-ISSUED ILSM.

5. EXISTING PARTITION TO SERVE AS INFECTION CONTROL BARRIER. MODIFY

PARTITION CONSTRUCTION AS REQUIRED TO BRING WALL TO 1 HOUR WALL

CONSTRUCTION, UL RATING U465. REMOVE EXISTING DOOR AND INSTALL

NEW DOOR AND FRAME PER CONSTRUCTION DWGS. SEAL DOOR FROM ONE

SIDE TO SERVE AS A CONSTRUCTION AND INFECTION CONTROL BARRIER.

6. EXISTING PARTITION TO SERVE AS CONSTRUCTION AND INFECTION

CONTROL BARRIER. MODIFY PARTITION CONSTRUCTION AS REQUIRED TO

BRING WALL TO 1 HOUR WALL CONSTRUCTION, UL RATING U465. WHERE

APPLICABLE, REMOVE EXISTING DOOR, FRAME AND ASSOCIATED

HARDWARE. INFILL OPENING WITH REQUIRED CONSTRUCTION TO MAINTAIN

U465 CONSTRUCTION.

7. PROVIDE 2 HOUR FIRE RATED CONSTRUCTION AND INFECTION CONTROL

BARRIER AROUND EXISTING 2 HOUR SHAFT TO PROVIDE PROTECTION WHEN

EXISTING SHAFT IS OPENED FOR MECHANICAL AND PIPING CONNECTIONS.

PROVIDE 90 MINUTE RATED METAL DOOR ASSEMBLY AND FRAME WITH

SEALS, HARDWARE AND CLOSER. BUILD BARRIER WALL DURING THE HOURS

OF 5PM TO 5AM.

8. REMOVE EXISTING DOORS AND RETURN TO VA. PROVIDE A 1-HOUR

CONSTRUCTION BARRIER WALL IN CORRIDOR. ALL WORK TO BE DONE OFF-

HOURS.

9. TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION PER

NFPA 241 TO BECOME 1 HR RATED PARTITION FOR NEW CONSTRUCTION.

10. WORK WILL TAKE PLACE IN THIS CORRIDOR OUTSIDE OF SCOPE BOUNDARY.

WORK TO INCLUDE ABATEMENT AND DEMOLITION OF FLOORING AND WALL

GUARDS. PREPARE EXISTING WALLS FOR NEW FINISHES. A PORTION OF

THIS AREA WILL ALSO INVOLVE ABOVE CEILING WORK. PROVIDE INFECTION

CONTROL PLAN TO COR FOR APPROVAL PRIOR TO BEGINNING WORK. ALL

WORK OUTSIDE OF PROJECT BOUNDARY TO BE DONE OFF-SHIFT.

11. CONTRACTOR TO PROVIDE SCRUBBER IN ANTEROOM AREA.

A. REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED

BY CLASS IN SPECIFICATION 010110SN AND 01 35 26 FOR ADDITIONAL

INFORMATION.

B. REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE

FOR ADDITIONAL INFORMATION.

C. COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS AND

FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE

CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE

PROJECT BOUNDARY.

D. COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER

WALL CONSTRUCTION AND INFECTION CONTROL (IC) MEASURES WITH COR

AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE. TEMPORARY

IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE

APPROXIMATE. CONTRACTOR SHALL PROVIDE INFECTION CONTROL

WORKPLAN AND DRAWING TO COR FOR APPROVAL BEFORE ANY DEMO.

E. SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR

AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE

PHASING INFORMATION FOR 6TH FLOOR ABOVE CEILING WORK IN THE

CONTRACTOR PROVIDED CMP SCHEDULE FOR WORK ALSO REQUIRED

ABOVE AND BELOW THE FLOOR PLATE OF THE PROJECT BOUNDARY.

F. SIXTH FLOOR ABOVE CEILING WORK SHALL TAKE PLACE BETWEEN THE

HOURS OF 5:00 PM AND 5:00 AM. IN AREAS THAT REQUIRE ABOVE CEILING

WORK WHERE CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE REMOVED

AND STORED IN A SAFE MANOR UNTIL CEILING TILES CAN BE REINSTALLED.

DAMAGED AND BROKEN CEILING TILES SHALL BE REPLACED BY

CONTRACTOR.

G. EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED

DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF

OPERATION.

H. WORK REQUIRING VIBRATION OR LOUD NOISE SHALL TAKE PLACE BETWEEN

THE HOURS OF 5:00 PM AND 5:00 AM. EVERY EFFORT SHALL BE MADE TO

KEEP NOISE AND VIBRATION TO A MINIMUM.

I. PROVIDE A 24"X36" STICKY WALK OFF MAT AT EACH TEMPORARY DOOR

LOCATION. MAT SHALL BE REPLACED OR CLEANED AS NECESSARY

J. PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH

TEMPORARY DOOR LOCATION.

K. CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,

MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE

LIQUIDS UP TO 30 GALLONS.

L. ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED

WITH 4 MIL. POLY SHEET.

M. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT

BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED

ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED

WITH A LID. REMOVE DEBRIS DAILY; BEFORE 7AM OR AFTER 4PM.

N. ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY

STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE

MATERIALS SHALL NOT BE STORED IN THE FACILITY.

O. PROVIDE CONTAINMENT CART (SHARK TANK) FOR ABOVE CEILING ACCESS

OUTSIDE PROJECT BOUNDARY.

P. CONTRACTOR SHALL PROVIDE INFECTION CONTROL PLAN TO VA FOR

REVIEW AND APPROVAL DURING PRECONSTRUCTION PHASE. CONTRACTOR

SHALL PROVIDE CALCULATIONS FOR NEGATIVE ARE MACHINES NEEDED

SHOWING QUANTITY REQUIRED AND LOCATIONS INSIDE 7AS. CONTRACTOR

SHALL PROVIDE CUTSHEET AND PRODUCT INFORMATION OF NEGATIVE AIR

MACHINE INTENDED WITH INFECTION CONTROL PLAN SUBMITTAL.

INFECTION CONTROL PLAN NOTES

INFECTION CONTROL GENERAL NOTES

INFECTION CONTROL PLAN NOTES

1 2 6

9 10

3 4 5 7 8

11 13 15 17 191612

K

H

E

C

B

A

J

D

OFFICE

CORRIDOR

C7A14

OFFICE

OFFICE

SUPPLY

7102A

SUPPLY

TOILET

EXAM

EXAM

EXAM

EXAM

EXAM

EXAM

OFFICE

TOILET

OFFICE

OFFICE

ORTHO WAITING

OFFICE

HAC

FAC

7A01

STORAGE

TOILET

7134A

TOILET

STR

7-4

TOILET

EC

EC

ORTHO SUPPLY

SOILED UTILITY

EXAM

EXAM

7142 EXAM

EXAM

EXAM

CAST RM

7146 STORAGE

7148A

STORAGE

EXAM

TOILET

7146A

FAC

7A02

EC

EC

OFFICE

7110A

OFFICE

7110C

OFFICE

CORRIDOR

C7A13

CORRIDOR

C7A12

CORRIDOR

C7A11

CORRIDOR

C7A11A

CORRIDOR

C7A08

HALLWAY

A0733

CORRIDOR

C7A07

TOILET

7119A

TOILET

7117A

TOILET

7115A

TOILET

7107A OFFICE

OFFICE

OFFICE

EXAM

EXAM

TOILET

7215A

TOILET

7207A

WAITING

EXAM

TOILET

7150A

TOILET

7252A

OFFICE

STORAGE

7250A

STORAGE

LAB

7246 BREAK

WOUND STAFF

7240C

RESTROOM

WAITING

MED RM

7210A

OFFICE

OFFICE

WAITING

CONTROL

7150B

WOUND

7240B

PROCTO

7240A

TOILET

CORRIDOR

C7A04A

CORRIDOR

C7A01

CORRIDOR

C7A05

CIRRIDOR

C7A04

HAC

VP

7-29

TOILET

TOILET

CORRIDOR

C7B02

STORAGE

OFFICE

EXAM

ELEV

7-A-5

ELEV

7-A-6

ELEV

7-A-8

ELEV

7-A-7

OFFICE

OFFICE

OFFICE

EXAM

EXAM

EXAM

DIRTY UTILITY

ENT OFFICE

OFFICE

OFFICE

EXAM

ENT SUPPLY

7306A

HALLWAY

C7B10

CORRIDOR

C7B10A

STR

7-1

ELEV

7-B-12

ELEV

7-B-9

TC

EC

ELEV

7-B-10

ELEV

7-B-11

ELEV LOBBY

C7B05

CORRIDOR

C7B04

CORRIDOR

C7B03B

TRASH RM

OFFICE

OFFICE

5,165 CF

2,915 CF 2,719 CF

1,371 CF

665 CF

2,370 CF

3,125 CF 3,084 CF 1,257 CF 1,254 CF 1,342 CF 1,395 CF

1,697 CF 3,016 CF

225 CF

230 CF

225 CF 230 CF

1,234 CF

2,786 CF

1,940 CF

1,665 CF

1,792 CF

744 CF

1,078 CF

1,840 CF

1,180 CF

1,300 CF

393 CF

3,018 CF

3,018 CF

2,900 CF

327 CF

2,413 CF

3,116 CF

3,054 CF

1,490 CF2,443 CF

744 CF

425 CF

1,577 CF

476 CF

292 CF371 CF

3,853 CF

2,553 CF

1,956 CF

11,976 CF

4,243 CF

B

C

PROJECT AREA A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\d v a lla n d in g h a m \D o c u m e n ts

\1

.1

.1

A v d v a lla n d in g h a m g u id o n d e s ig n .c o m

.r v t

/5

/2

:2

:2

P M

GC101

INFECTION CONTROL/PHASING

PLANGUIDON

1221 N. PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

317.800.6388

RING & DUCHATEAU, LLP.

17400 W. CAPITOL DRIVE

BROOKFIELD, WI 53045

414.778.1700

RENOVATE AND EXPAND

DIALYSIS CLINIC

5000 W National Ave, Milwaukee, WI 53295

695-19-131

03/26/2020

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 1 1/2" = 1'-0"GC101

1 TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION NFPA 241

SCALE: 1/4" = 1'-0"GC101

2 TEMPORARY WALL CONSTRUCTION ELEVATION

SCALE: 1/8" = 1'-0"GC101

4 SEVENTH FLOOR PLAN

N SCALE: 1" = 100'-0"

KEY PLAN

Revisions: Date:

ADDENDUM 02 06/05/2020

File details come from the government source that posted it. Updated .