S06 Att Amend 0002 EP401 - ONE LINE DIAGRAM.pdf

PDF 137 KB Posted

Attached to
Z2DA--Project # 695-19-131 Renovate and Expand Dialysis Clinic Clement J. Zablocki VA Medical Center Milwaukee, WI
Solicitation number
36C25220B0021
Issued by

About this file

This document provides details for a federal contract opportunity to renovate and expand a dialysis clinic at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The contract scope of work includes demolition, construction trades such as concrete, electrical, plumbing, mechanical, and architectural services. Specialty furnishings are required to support the dialysis mission. Hazardous materials abatement is also included. The total square footage to be renovated is approximately 11,000 square feet. The project magnitude price range is between $2,000,000 and $5,000,000. The period of performance is 540 calendar days. The solicitation is scheduled to post on May 13, 2020 with a bid opening of June 16, 2020. A pre-bid conference will be held. This opportunity is a 100% Service Disabled Veteran Owned Small Business set-aside issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12.

View the file

Other files

File Type Posted
Amend 0005 00 01 10 TABLE OF CONTENTS.pdf PDF
Amend 0005 22 67 19.16 REVERSE-OSMOSIS WATER EQUIPMENT.pdf PDF
Amend 0005 08 71 13.11 LOW ENERGY DOOR OPERATORS.pdf PDF
S06 36C25220B0021 0005.pdf PDF
Amend 0005 01 91 00 COMMISSIONING REQUIREMENTS.pdf PDF
Amend 0005 01 01 10 SN SPECIAL NOTES.pdf PDF
Amend 0005 11 73 00 CEILING MOUNT PATIENT LIFT.pdf PDF
Amend 0005 14 92 00 PNEUMATIC TUBE SYSTEM.pdf PDF
Amend 0003 Photos Revised.pdf PDF
S06 36C25220B0021 0004.pdf PDF
AI601 - FINISH SCHEDULES.pdf PDF
Wage Determination 6.19.20.pdf PDF
Amend 0003 Photos.pdf PDF
SECTION 10 21 23 - CUBICLE CURTAIN TRACKS.pdf PDF
36C25220B0021 0003.pdf PDF
S06 Att Amend 0002 00 01 10 - TABLE OF CONTENTS.pdf PDF
S06 Att Amend 0002 EP100 - BASEMENT FLOOR OVERALL PLAN.pdf PDF
S06 Att Amend 0002 AI201 - INTERIOR FINISHES ELEVATIONS.pdf PDF
S06 Att Amend 0002 AE601 - DOOR_WINDOW SCHEDULE.pdf PDF
S06 36C25220B0021 0002.pdf PDF
S06 Att Amend 0002 28 05 13 - CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY.pdf PDF
S06 Att Amend 0002 10 21 23 - CUBICLE CURTAIN TRACKS.pdf PDF
S06 Att Amend 0002 01 74 19 - CONSTRUCTION WASTE MANAGEMENT.pdf PDF
S06 Att Amend 0002 GC101 - INFECTION CONTROL_PHASING PLAN.pdf PDF
S06 Att Amend 0002 09 05 16 - FLOOR PREP1.pdf PDF
S06 Att Amend 0002 ET102 - SEVENTH FLOOR SYSTEMS PLAN - DIVISION 28.pdf PDF
S06 Att Amend 0002 AD101 - SEVENTH FLOOR DEMOLITION PLAN.pdf PDF
S06 Att Amend 0002 MD101 - MECHANICAL DEMOLITION FLOOR PLAN - 7TH FLOOR.pdf PDF
S06 Att Amend 0002 10 14 00 - SIGNAGE.pdf PDF
S06 Att Amend 0002 12 24 00 - WINDOW SHADES.pdf PDF
S06 Att Site Visit Sign In 5.28.20.pdf PDF
S06 Att Amend 0002 03 30 53 - CAST-IN-PLACE CONCRETE.pdf PDF
S06 Att Amend 0002 QH101 - SEVENTH FLOOR EQUIPMENT PLAN.pdf PDF
S06 Att Amend 0002 01 91 00 - COMMISSIONING REQUIREMENTS.pdf PDF
S06 Att Amend 0002 22 07 11 - PLUMBING INSULATION.pdf PDF
S06 Att Amend 0002 ET101D - SEVENTH FLOOR DEMOLITION PLAN.pdf PDF
S06 Att Amend 0002 22 11 00 - FACILITY WATER DISTRIBUTION.pdf PDF
S06 Att Amend 0002 AE501 - BUILDING DETAILS.pdf PDF
S06 Att Amend 0002 AI901 - SIGNAGE PLAN.pdf PDF
S06 Att Amend 0002 AI101 - FINISH WALL TREATMENT PLAN.pdf PDF
S06 Att Wage Determination 6.5.20.pdf PDF
Site Visit Sign In 5.20.20.pdf PDF
36C25220B0021 0001.docx DOCX document
Amend 0001 Specification 22 63 00.pdf PDF
Amend 0001 Specification 00 01 10.pdf PDF
Amend 0001 Specification 08 14 00.pdf PDF
Amend 0001 Specification 09 06 00.pdf PDF
Amend 0001 J_A Patient Ceiling Lift.pdf PDF
36C25220B0021-011.pdf PDF
36C25220B0021-012.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2-1/2"C.

#4/0 &4

#4 GRD1

COPPER

1"C.

#6 &3

#10 GRD1

COPPER

1-1/2"C.

#3 &4

#8 GRD1

COPPER

P: 480V DELTA

S: 208Y/120V

EE 150°C

DT 30 kVA

MC

MC

MC

2-1/2"C.

#3/0 &4

#6 GRD1

COPPER

RMS SYM @ 480 VOLTS

480/277 VOLTS 3Ø 4W

42k AMPS

GROUP MOUNTED

SS

L3

2-1/2"C.

#4/0 &4

#4 GRD1

COPPER

2-1/2"C.

#4/0 &4

#4 GRD1

COPPER

SS

L2

1-1/4"C.

#3 &4

#8 GRD1

COPPER

1. PANEL AND ALL ASSOCIATED COMPONENTS SHALL BE REMOVED,

SALVAGED, AND RELOCATED TO ELECTRICAL ROOM. CAPTURE

EXISTING CIRCUITS AND EXTEND TO NEW PANEL. THIS PANEL

CONTAINS APPROXIMATELY (17) 20A/1P CIRCUITS TO BE RELOCATED.

2. PROVIDE CONDUCTOR SUPPORTS FOR VERTICAL RACEWAY. REFER

TO ENLARGED FLOOR PLANS FOR APPROXIMATE LOCATIONS.

3. REMOVE MAIN CIRCUIT BREAKER FROM RELOCATED PANEL. A NEW

ENCLOSED CIRCUIT BREAKER SHALL BE PROVIDED TO COORDINATE

WITH EXISTING SYSTEM.

SCALE: NOT TO SCALE

EP401SCALE: NOT TO SCALE

EP401SCALE: NOT TO SCALE

EP401

SCALE: NOT TO SCALE

EP401 SCALE: NOT TO SCALE

EP401

SCALE: NOT TO SCALE

EP401

SCALE: NOT TO SCALE

EP401

CB

LL-71-1

CB

UL-71-1

PB-LH

71-1

PB UL

71-1

PB UL

71-1

CB

EUL-CR-71-1

PB EUL

CR-71-1

JB

ELHCR711

CB

ELHCR711

LL

71-1

EX FEEDER

FED FROM

DL-B01-2

ELH-LS

91-1

EX

100A FEEDER

EPH-Q

71-1

EUL-Q

71-1

EX

100A FEEDER

LH

71-1

100 A

3P

UL

71-1

EX FEEDER

FED FROM

DL-B01-2

225 A

3P

ELH-CR

71-1

100 A

3P

EUL-CR

71-1

EX FEEDER

FED FROM

EDL-CR-B01-1

ELH-CR

71-1

1600AMPS @

MAIN SECTION:

DISTRIBUTION SECTION:

MIN AIC RATING =

EATON POW-R-LINE C SWITCHBOARD

SWITCHBOARD CONSTRUCTION

225 A

3P

225AF

3P

100AT

PARTIAL ONE LINE DIAGRAM - NORMALPARTIAL ONE LINE DIAGRAM-NORMALPARTIAL ONE LINE DIAGRAM-CRITICAL

PARTIAL ONE LINE DIAGRAM - EQUIPMENT

PARTIAL ONE LINE DIAGRAM-LIFE SAFETY

T/EULQ711

PARTIAL ONE LINE DIAGRAM-NORMAL

KEYED NOTES -

7TH FLOOR A SOUTH7TH FLOOR A SOUTH7TH FLOOR A SOUTH

9TH FLOOR A SOUTH 7TH FLOOR AREA A NORTH

8TH FLOOR AREA A NORTH

PARTIAL ONE LINE DIAGRAM-NORMAL

7TH FLOOR AREA A NORTH

EDH-307-Q-4

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C

R e v it L o c a lF ile s \2

.0

M

P e re z ri n g d u .c o m

.r v t

/3

/2

:3

:2

P M

EP401

ONE LINE DIAGRAM

GUIDON DESIGN INC.

1221 N. Pennsylvania Street

Suite 200

Indianapolis, Indiana 46202

317.800.6388

RING & DUCHATEAU, LLP.

17400 W. Capital Drive

Brookfield, WI 53045

414.778.1700

RENOVATE AND EXPAND

DIALYSIS CLINIC

5000 W National Ave, Milwaukee, WI 53295

695-19-131

03/26/2020 MGM MTP

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Revisions: Date:

ADDENDUM 02 06/05/2020

ADD

Sheets
EP100 - BASEMENT FLOOR OVERALL PLAN
EP401 - ONE LINE DIAGRAM
ET102 - SEVENTH FLOOR SYSTEMS PLAN - DIVISION 28

File details come from the government source that posted it. Updated .