This solicitation notice and construction documents outline requirements for a federal contract to renovate and expand the dialysis clinic at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin. The contract will require demolition of an existing vacant ward and construction of a new approximately 11,000 square foot dialysis clinic in its place. Scope of work will include trades such as demolition, concrete, electrical, plumbing, HVAC, architectural, and specialty furnishings to support the dialysis mission. The pre-solicitation is scheduled to post to FedBizOpps on May 13, 2020 with a bid opening tentatively set for June 16, 2020. In accordance with the VAAR, the solicitation will be issued as a 100% Service Disabled Veteran Owned Small Business set-aside with a contract value estimated between $2-5 million. The period of performance is 540 calendar days from notice to proceed.
View the file
Other files
Show 40 more
Latest 50 of 72 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Milwaukee VAMC 10-01-15
695-19-131 Renovate & Expand Dialysis Clinic 100% Construction Documents
Milwaukee, WI 53295 March 26, 2020
10 14 00 - 1
SECTION 10 14 00
SIGNAGE
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies interior signage for room numbers, directional signs exterior signage, code required signs and temporary signs.
B. This section specifies exterior signage.
1.2 RELATED WORK
A. Electrical Work: Division 26, ELECTRICAL.
B. Lighted EXIT signs for egress purposes are specified under Division 26, ELECTRICAL.
1.3 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Provide signage that is the product of one manufacturer, who has provided signage as specified for a minimum of three (3) years. Submit manufacturer’s qualifications.
B. Installer’s Qualifications: Minimum three (3) years’ experience in the installation of signage of the type as specified in this Section.
Submit installer’s qualifications.
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 00, SHOP DRAWINGS, PRODUCT DATA
AND SAMPLES.
B. Sustainable Design Submittals, as described below:
1. Volatile organic compounds per volume as specified in PART 2 -
PRODUCTS.
C. Interior Sign Samples: Sign panels and frames, with letters and symbols, for each sign type.
1. Sign Panel, 203 x 254 mm (8 x 10 inches), with letters.
2. Color samples of each color, 152 x 152 mm (6 x 6 inches. Show anticipated range of color and texture.
3. Sample of typeface, arrow and symbols in a typical full size layout.
D. Exterior Sign Samples: 152 x 152 mm (6 x 6 inches) samples of each color and material.
E. Manufacturer's Literature:
1. Showing the methods and procedures proposed for the anchorage of the signage system to each surface type.
2. Manufacturer’s printed specifications and maintenance instructions.
10 14 00 - 2
F. Sign Location Plan, showing location, type and total number of signs required.
G. Shop Drawings: Scaled for manufacture and fabrication of sign types.
Identify materials, show joints, welds, anchorage, accessory items, mounting and finishes.
H. Full size layout patterns for dimensional letters.
I. Manufacturer’s qualifications.
J. Installer’s qualifications.
1.5 DELIVERY AND STORAGE
A. Deliver materials to job in manufacturer's original sealed containers with brand name marked thereon. Protect materials from damage.
B. Package to prevent damage or deterioration during shipment, handling, storage and installation. Maintain protective covering in place and in good repair until removal is necessary.
C. Deliver signs only when the site and mounting services are ready for installation work to proceed.
D. Store products in dry condition inside enclosed facilities.
1.6 WARRANTY
A. Construction Warranty: Comply with FAR clause 52.246-21, “Warranty of
Construction”.
1.7 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.
B. American Architectural Manufacturers Association (AAMA):
611-14..................Anodized Architectural Aluminum
2603-13.................Voluntary Specification, Performance
Requirements and Test Procedures for Pigmented
Organic Coatings on Aluminum Extrusions and
Panels
C. American National Standards Institute (ANSI):
A117.1-09...............Accessible and Usable Buildings and Facilities
D. ASTM International (ASTM):
A36/A36M-14.............Carbon Structural Steel
A240/A240M-15...........Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and for General Applications
10 14 00 - 3
A666-10.................Annealed or Cold-Worked Austenitic Stainless
Steel Sheet, Strip, Plate and Flat Bar
A1011/A1011M-14.........Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-
Strength Low-Alloy with Improved Formability, and Ultra-High Strength
B36/B36M-13.............Brass Plate, Sheet, Strip, and Rolled Bar
B152/B152M-13...........Copper Sheet, Strip, Plate, and Rolled Bar
B209-14.................Aluminum and Aluminum-Alloy Sheet and Plate
B209M-14................Aluminum and Aluminum-Alloy Sheet and Plate
(Metric)
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)
C1036-11(R2012).........Flat Glass
C1048-12................Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass
C1349-10................Architectural Flat Glass Clad Polycarbonate
D1003-13................Test Method for Haze and Luminous Transmittance of Transparent Plastics
D4802-10................Poly(Methyl Methacrylate) Acrylic Plastic Sheet
D. Code of Federal Regulation (CFR):
40 CFR 59...............Determination of Volatile Matter Content, Water
Content, Density Volume Solids, and Weight
Solids of Surface Coating
E. Federal Specifications (Fed Spec):
MIL-PRF-8184F...........Plastic Sheet, Acrylic, Modified.
MIL-P-46144C............Plastic Sheet, Polycarbonate
F. National Fire Protection Association (NFPA):
70-14...................National Electrical Code
PART 2 - PRODUCTS
2.1 INTERIOR SIGN TYPES
A. Conform to the signage by 290/Systems.
B. Provide insert and frame component system.
C. Basis of Design for Interior Signage is 2/90 Sign Systems. They can provide the station standard.
10 14 00 - 4
D. Temporary Interior Signs:
1. Fabricated from 50 kg (110 pound) matte finished white paper cut to
101 mm (4 inch) wide by 305 mm (12 inch) long.
a. Punched 3.2 mm (.125 inch) hole with edge of hole spaced 13 mm
(.5 inch) in from edge and centered on 101 mm (4 inch) side.
b. Reinforce hole on both sides with suitable material that prevents tie from pulling through hole.
c. Ties: Steel wire 0.3 mm (0.120 inch) thick attached to tag with twist leaving 152 mm (6 inch) long free ends.
2. Mark architectural room number on sign, with broad felt marker in clearly legible numbers or letters that identify room, corridor or space as shown on construction documents.
3. Install temporary signs to rooms that have a room, corridor or space number. Attach to door frame, door knob or door pull.
a. Doors that do not require signs are: corridor doors in corridor with same number, folding doors or partitions, toilet doors, bathroom doors within and between rooms, closet doors within rooms, communicating doors in partitions between rooms with corridor entrance doors.
b. Replace and missing, damaged or illegible signs.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Locate signs as shown on the construction documents.
B. At each sign location there are no utility lines behind each sign location that will be affected by installation of signs.
1. Correct and repair damage done to utilities during installation of signs at no additional cost to Government.
C. Provide inserts and anchoring devices which must be set in concrete or other material for installation of signs. Submit setting drawings, templates, instructions and directions for installation of anchorage devices, which may involve other trades.
D. Refer to Sign Message Schedule for mounting method. Mount signs in proper alignment, level and plumb according to the Sign Location Plan and the dimensions given on elevation and Sign Location Plans. When exact position, angle, height or location is not clear, contact COR for resolution.
10 14 00 - 5
E. When signs are installed on glass, provide blank glass back up to be placed on opposite side of glass exactly behind sign being installed.
Provide blank glass back that is the same size as sign being installed.
F. Touch up exposed fasteners and connecting hardware to match color and finish of surrounding surface.
G. At completion of sign installation, clean exposed sign surfaces. Clean and repair adjoining or adjacent surfaces that became soiled or damaged as a result of installation of signs.
- - - END - - -