This document contains a pre-solicitation notice and related federal contract opportunity for the modernization of Building 22 at the Ann Arbor Veterans Affairs Medical Center. The Department of Veterans Affairs intends to issue an invitation for bid on or around November 30th, 2022 for construction services to modernize Building 22 including all necessary labor, materials, equipment and supervision. The work is estimated to cost between $5-10 million and will be awarded as a firm fixed price contract within 120 days of bid opening. This opportunity is reserved exclusively for qualified Service-Disabled Veteran Owned Small Businesses. The eventual awardee must be registered in the System for Award Management and Vendor Information Pages databases. All questions must be submitted in writing to the named contracting specialist by the date specified in the forthcoming solicitation.
View the file
Other files for this federal contract opportunity
Show all 49
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING VALVE SYMBOLS
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENTAV
GENERAL PLUMBING SYMBOLS
LIMIT OF DEMOLITION
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
POINT OF CONNECTION BETWEEN NEW AND
EXISTING WORK
PRESSURE GAGE
THERMOMETER
STRAINER
FLOW ELEMENT
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES
INVERTED BUCKET TRAP SET INCLUDING
PIPING ACCESSORIES
FE
PIPE UP
PIPE DOWN
CO CLEAN OUT
HOSE BIB
DRAWING SYMBOLS
PL101
A
26-P 3
DETAIL NUMBER
DRAWING NUMBER WHERE SHOWN
SECTION LETTER
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT IS LOCATED.
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
DRAWING NUMBER WHERE DRAWN
PL105
PIPING CONTINUATION
PLUMBING ABBREVIATIONS
REVISION NUMBER
PIPING SYMBOLS
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
LABORATORY VACUUM
LABORATORY AIR
MEDICAL VACUUM
MEDICAL AIR
MA
VENT (SANITARY)
DCW
DHW
DHWR
MV
LA
LVC
OXYGEN
O
SANITARY SEWER
SAN
STORM WATER
SW
V
DIALYSIS WATER SUPPLY
DWS
FILTERED COLD WATER
FCW
FUEL OIL DISCHARGE
FOD
FUEL OIL RETURN
FOR
FUEL OIL SUPPLY
FOS
FUEL OIL VENT
FOV
NATURAL GAS
G
NITROGEN
N2
NITROUS OXIDE
N2O
SOFTEN COLD WATER
SCW
TEMPERED WATER RETURN
TWR
TEMPERED WATER SUPPLY
TWS
PLUMBING GENERAL NOTES
A. THE FOLLOWING NOTES APPLY EQUALLY TO THE FULL SET OF PLUMBING DOCUMENTS.
B. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
C. REFER TO SCHEDULES, DETAILS, AND DIAGRAMS FOR PIPING, PIPE SIZES AND PIPELINE DEVICES NOT
INDICATED ON FLOOR PLAN.
D. LOCATIONS AND SIZES OF EXISTING PIPING SHOWN ON THIS DRAWING HAVE BEEN DETERMINED FROM A REVIEW OF EXISTING DRAWINGS AND/OR SITE INVESTIGATION WHERE POSSIBLE. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE WORK SHOWN ON THE CONTRACT DRAWINGS WHICH MAY IMPACT THE PROGRESS OF WORK SHALL BE BROUGHT
TO THE ATTENTION OF THE VA IN WRITING BEFORE PROCEEDING WITH THE WORK.
E. EACH CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE WORK OF OTHERS.
F. ALL WORK SHALL BE IN COMPLIANCE WITH GOVERNING CODES AND VA STANDARDS.
G. PROVIDE ACCESS PANELS IN NON-ACCESSIBLE SUSPENDED CEILINGS FOR VALVES, CLEANOUTS, CONTROLS, ETC.
H. ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE PROTECTED AND/OR FIRESTOPPED AS REQUIRED TO MAINTAIN FIRE RATINGS. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE-RATED
ASSEMBLIES.
I. CONTRACTOR TO IMMEDIATELY INFORM THE COR IN THE EVENT THAT MATERIALS OBSERVED ARE
SUSPECTED TO CONTAIN ASBESTOS.
J. PROVIDE OFFSETS AS NECESSARY TO COMPLETE SYSTEMS AND COORDINATE WORK WITH OTHER TRADES.
MEDICAL AIR OUTLET
OXYGEN OUTLET
MEDICAL VACUUM OUTLET
A
O
V
PIPING PENETRATION THROUGH FLOOR/ROOF
CIRCUIT SETTER
NEW PIPING
PIPING TO BE REMOVED
EXISTING PIPING
A/E ARCHITECT / ENGINEER
AD AREA DRAIN/ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER/AIR SEPARATOR
ASD ADJUSTABLE SPEED DRIVES/AUTOMATIC SPRINKLER DRAIN
ASHRAE AMERICAN SOCIETY OF HEATING REFRIGERATION AIR
CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
AXF AXIAL FLOW
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BPW BEDPAN WASHER
BSP BLACK STEEL PIPE
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C CENTIGRADE (CELSIUS)
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CHP CHILLED WATER PUMP
CHW CHILLER WATER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CI CAST IRON
CM COUNTER MOUNTED/CUBIC METER
CO CLEAN OUT
CO2 CARBON DIOXODE
COMP COMPARTMENT
CS CLINICAL SINK
CV CONSTANT VOLUME/CONTROL VALVE
D DRAIN
DCW DOMESTIC COLD WATER
DD-1 DESIGN DEVELOPMENT (SUBMISSION 1)
DD-2 DESIGN DEVELOPMENT (SUBMISSION 2)
DDC DIRECT DIGITAL CONTROLS
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DI DEIONIZED WATER
DIA DIAMETERN
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWS DIALYSIS WATER SUPPLY
DWV DRAIN WASTE VENT
EL ELEVATION
EPA ENVIRONMENTAL PROTECTION AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EWS/SH EYE WASH/DRENCH SHOWER
(E) EXISTING TO REMAIN
F FAHRENHEIT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FF FINISHED FLOOR
FM FLOW METER/FLOOR MOUNTED
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOT FUEL OIL TANK
FOV FUEL OIL VENT
FOHX FUEL OIL HEAT EXCHANGER
FPS FEET PER SECOND
FS FLOW SWITCH/FLOOR SINK
FT FEET
FT WC FEET OF WATER COLUMN
FT-LB FOOT-POUND
FU FIXTURE UNITS
GAL GALLON
GCO GRADE CLEANOUT
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H&CW HOT AND COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HD HUB DRAIN
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN (STEAM CONDENSATE)
HPS HIGH PRESSURE SUPPLY (STEAM)
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
HX HEAT EXCHANGER
HYD HYDRANT
IBT INVERTED BUCKET TRAP
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
KG KILOGRAM
KW KILOWATT
KWH KILOWATT HOUR
L LITER
L/H LITERS PER HOUR (or LITERS/HOUR) L/M LITERS PER MINUTE (or LITERS/MINUTE) L/S LITERS PER SECOND (or LITERS/SECOND)
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LF LINEAR FOOT (FEET)
LPG LIQUEFIED PETROLEUM GAS
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LPR LOW PRESSURE RETURN (STEAM CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN (CLEAN)
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LVC LABORATORY VACUUM
LV LABORATORY VENT
LW LABORATORY WASTE
M METER
M/S METERS PER SECOND (OR METERS/SECOND)
MA MEDICAL AIR
MAV MANUAL AIR VENT
MAX MAXIMUM
MBH 1,000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MOU MEMORANDUM OF UNDERSTANDING
MPR MEDIUM PRESSURE RETURN (STEAM CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MS MOP SINK
MV MEDICAL VACUUM
N2 NITROGEN
N2O NITROUS OXIDE
NA NOT APPLICABLE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NGFM NATURAL GAS FLOWMETER
NO NORMALLY OPEN
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NPSHA NET POSITIVE SUCTION HEAD AVAILABLE
NPSHR NET POSITIVE SUCTION HEAD REQUIRED
NPW NON POTABLE WATER
NTS NOT TO SCALE
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PDI PLUMBING AND DRAINAGE INSTITUTE
PG PRESSURE GAGE
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PTRV PRESSURE TEMPERATURE RELIEF VALVE
PW POTABLE WATER
RCP RECIRCULATING PUMP
RCW RAW COLD WATER
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RTU ROOF TOP UNIT
RV RELIEF VALVE
SAN SANITARY SEWER
SCFM STANDARD CUBIC FEET PER MINUTE
SCW SOFTENED COLD WATER
SHW SOFTENED HOT WATER
SD SMOKE DETECTOR
SDMH STORM DRAIN MANHOLE
SD-1 SCHEMATIC DESIGN (SUBMISSION1)
SD-2 SCHEMATIC DESIGN (SUBMISSION2)
SF SQUARE FOOT (FEET)
SH SHOWER
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SMH SANITARY MANHOLE
SP SUMP PUMP/STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPRV STEAM PRESSURE REDUCING VALVE
SS STAINLESS STEEL
ST STORAGE TANK/STEAM TRAP
SW STORM WATER
SW SOFTWATER
SWHX STEAM TO WATER HEAT EXCHANGER
TCV TEMPERATURE CONTROL VALVE
TD TRENCH DRAIN/TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TDS TOTAL DISSOLVED SOLIDS
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
UG UNDERGROUND
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VP VACUUM PUMP
VS VENT STACK
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WASTE/WATTS
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT/WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER/WALL MOUNTED
WPD WATER PRESSURE DROP
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
YCO YARD CLEANOUT
YH YARD HYDRANT
ZV ZONE VALVE
LABORATORY WASTE (CORROSION RESISTANT)
LW
LABORATORY VENT (CORROSION RESISTANT)
LV
RAW COLD WATER (CITY WATER)
RCW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /A n n A rb o r
V A
M o d e rn iz e B ld g
/F
F E
A n n A rb o r
M o d e rn iz e
B
M E
P rv t
/2
/2
:4
:4
A M
P001
PLUMBING LEGEND SHEET
09/02/2022 PP GP
MODERNIZE BUILDING 22 506-21-102
ANN ARBOR, MICHIGAN
100% BID DOCUMENTS
ANN ARBOR
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
100% BID DOCUMENTS 09/02/2022
2 ADDENDUM 02 03/02/2023
09/02/2022
| Sheets |
| P001 - PLUMBING LEGEND SHEET |
File details come from the government source that posted it. Updated .