B09_Attachment_51_-_A8-A20-A22-A24-A25-A26_REV_0008.pdf

PDF 1 MB Posted

Attached to
HAVO 305150 Phase II, Kilauea Visitor Center (KVC)
Solicitation number
140P2024R0114
Issued by

About this file

This document appears to be a set of architectural drawings for the Kilauea Visitor Center (KVC) renovation project at Hawaii Volcanoes National Park. The drawings detail the first floor plan, enlarged floor plans for the offices and comfort station, and various interior elevations. The project involves the rehabilitation of the existing KVC, demolition and replacement of the existing comfort station, and expansion of the existing lanai. Key details include the location, project purpose, and Phase II implementation status. The drawings provide floor plans, dimensions, materials, and other specifications for the renovations. This document does not contain information about the specific federal contract opportunity, such as the solicitation number, award details, pricing terms, or set-asides. It is solely focused on the architectural design elements of the KVC project.

View the file

Other files

File Type Posted
B08_Attachment_6_HAVO_305150_Wage_Determination_9_6_2024_0009.pdf PDF
Sol_140P2024R0114_Amd_0009.pdf PDF
B09_Attachment_25_-_Amd_08_Solicitation_QA_HAVO_305150_0008.xlsx XLSX spreadsheet
Sol_140P2024R0114_Amd_0008.pdf PDF
B09_Attachment_48_-_C9_WATER_PLAN_AND_PROFILE_II_REV_0007.pdf PDF
B09_Attachment_36_-_08_31_13_-_ACCESS_DOORS_AND_FRAMES_0007.pdf PDF
B09_Attachment_30_-_08_14_33_-_STILE_AND_RAIL_WOOD_DOORS_0007.pdf PDF
B09_Attachment_41_-_09_29_00_-_GYPSUM_BOARD_0007.pdf PDF
B08_Attachment_6_HAVO_305150_Wage_Determination_7_19_2024_0007.pdf PDF
B09_Attachment_38_-_08_80_00_-_GLAZING_0007.pdf PDF
B09_Attachment_46_-_A22-A28-A51_REV_0007.pdf PDF
B09_Attachment_44_-_10_28_00_-_TOILET_ACCESSORIES_0007.pdf PDF
B09_Attachment_43_-_09_51_13_-_ACOUSTICAL_PANEL_CEILINGS_0007.pdf PDF
B09_Attachment_32_-_06_20_13_-_Exterior_Finish_Carpentry_0007.pdf PDF
B09_Attachment_40_-_08_91_19_-_FIXED_LOUVERS_0007.pdf PDF
B09_Attachment_47_-_C6_C11_C16_REV_0007.pdf PDF
B09_Attachment_49_-_E15_REV_0007.pdf PDF
B09_Attachment_28_-_07_92_00_-_Joint_Sealants_0007.pdf PDF
B09_Attachment_50_-_E25_REV_0007.pdf PDF
B09_Attachment_29_-_08_12_13_-_Hollow_Metal_Frames_0007.pdf PDF
B09_Attachment_37_-_08_71_00_-_Door_Hardware_0007.pdf PDF
B09_Attachment_25_-_Amd_07_Solicitation_QA_HAVO_305150_0007.xlsx XLSX spreadsheet
B09_Attachment_35_-_07_72_00_-_Roof_Accessories_0007.pdf PDF
B09_Attachment_34_-_07_62_00_-_Sheet_Metal_Flashing_and_Trim_0007.pdf PDF
B09_Attachment_33_-_07_21_00_-_Thermal_Insulation_0007.pdf PDF
B09_Attachment_42_-_09_30_13_-_CERAMIC_TILING_0007.pdf PDF
B09_Attachment_31_-_01_77_00A_Closeout-OperationMaintenance-Requirements_0007.pdf PDF
B09_Attachment_39_-_08_83_00_-_MIRRORS_0007.pdf PDF
Sol_140P2024R0114_Amd_0007.pdf PDF
B09_Attachment_45_-_33_14_16___Site_Water_Utility_Distribution_0007.pdf PDF
B09_Attachment_27_-_01_33_23-A_SubmittalList-ReviewEstimate_0007.pdf PDF
B09_Attachment_26_-_00_-_Table_of_Contents_0007.pdf PDF
Attachment_23_-_Pre-proposal_Site_Visit_Sign-in_Roster_7_31_2024_0006.pdf PDF
Attachment_21_-_01_33_23-A_SubmittalList-ReviewEstimate_0006.pdf PDF
Attachment_18_-_R1_A42_CD_HAVO_KVC_0006.pdf PDF
Attachment_24_-_HAVO_305150B_Prebid_Meeting_Notes_7-31-24_0006.pdf PDF
Attachment_17_-_R1_A36_CD_HAVO_KVC_0006.pdf PDF
Sol_140P2024R0114_Amd_0006.pdf PDF
Attachment_25_-_Amd_06_Solicitation_QA_HAVO_305150_0006.xlsx XLSX spreadsheet
Attachment_22_-_01_77_00A_Closeout-OperationMaintenance-Requirements_0006.pdf PDF
Attachment_20_-_SECTION_08_71_00_-_DOOR_HARDWARE_-_REV_2_0006.pdf PDF
Attachment_19_-_R1_A49_CD_HAVO_KVC_0006.pdf PDF
Sol_140P2024R0114_Amd_0005.pdf PDF
B09_Attachment_15_-_Cold_Fluid-Applied_Waterproofing-rev1_07_14_16_0004.pdf PDF
B09_Attachment_16_-_S1_Basement-81_0004.pdf PDF
Sol_140P2024R0114_Amd_0004.pdf PDF
Sol_140P2024R0114_Amd_0003.pdf PDF
B09_Attachment_14_-_Site_Visit_Tri_Fold_HAVO_305150B_-_AMENDMENT_3_0003.pdf PDF
B09_Attachment_13_-_HAVO_305150_Prebid_Site_Visit_Insructions_0003.pdf PDF
B08_Attachment_2_HAVO305150_FinalCDDrawings_0002.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

X1 X3 X5 X9

XA

XA

XB

XC XC

XD XD

X8X6

XE XE

X4X2 X7

EXIST MEMORIAL

OUTLINE OF ROOF ABV

EXIST FLAG POLE

A22

A1

C1

A15

A3

A15

NEW STAIR TO

BASEMENT

A1

A15

(N) STONE KNEE WALL

C1

A17

A18

A1

A1

A16

LA

L1 L2 L3

LB

LC

LD

LE

LF

LG

LH

LI

12' - 0" 12' - 0" 12' - 0" 12' - 0"

R1 R2 38' - 8"

RE RE

RD

/4

/4

RC RC

RA

NEW R-19 INSULATION @ EXIST

EXTERIOR WALLS (TYP FOR

EXHIBITS/LOBBY, PARK STORE, PARK

STORE STORAGE)

LOUVER RAIN

SCREENS

A20

A1

24' - 0" 24' - 0"

A21

A1

2'

/2

9'

1/ 2"

11' - 3 3/4"

10' - 0 3/4"

A19

A1

PARK STORE

PARK

STORE

STORAGE

NEW HALLWAY

(E)

HALLWAY

BREAK ROOM

UTILITY

RR B

LACTATION

ROOM

RR A

EXHIBITS & LOBBY

HALAU

STORAGE

COMFORT

STATION LANAI

UNISEX WOMENSMENS

JANITORIAL

REUSE

SALVAGED WDW

(E) AUDITORIUM

CJ

CJ

CJ

CJ

1B

6A6C

6C1A

1A

1B

1A

1A 6M

1A

3C 3C

3B

3F 3G 3F 3G

3E

3D

3H

5A 5C

5E

5E

5F

5G 5B

5A

5D

4C

4B

3D

3A

2D 2A

2A

2A

2A

2E

2A

2A

2B

2C

2B

2F

W211

UNENCLOSED VERTICAL PLATFORM LIFT

2E

SEE CIVILLOUVER RAIN

SCREENS

N101

NEW DR IN

EXIST LOCATION

NEW CARPET FOR WALLS TO +/- 3'-0"

TO MATCH HT OF EXIST (VIF), NEW

PAINT, REINSTALL SALVAGED BASE

M

IN

C

LR

VIF LOC, WRAP

POST W/ 1X S4S

REPLACE WD SILL,

MATCH EXIST

REPAIR WD

SILL, MATCH

EXIST

REPLACE WD SILL,

MATCH EXIST

131 132 133130

102 103 104 105

160A

157A

125158

143144

166163

WRAP 6X6

POST W/ 1X S4S

6M

6C

6C 6E

6D6G6I

6F 6B

6C

6G 6J

6K

6H 6L

6L

1A 1A

1C

1B

3A 3A

6'

8'

18' - 8"

SEE CIVIL FOR

DECORATIVE INLAY

REQUIREMENTS

ALL DIMENSIONS ARE TO FACE OF STUD, UNO.

NON-BEARING INTERIOR PARTITIONS SHALL BE 2 X 4 WD STUDS, AT

16" OC WITH 1/2" GYPBD ON EACH SIDE, UNO.

PROVIDE R-19 INSULATION AT ALL EXTERIOR WALLS THAT

SEPARATE CONDITIONED AND NON CONDITIONED SPACES.

SEE A49 FOR DOOR SCHEDULE.

SEE A50 FOR WINDOW SCHEDULE.

1.

2.

3.

4.

5.

WALL SECTION OR

DETAIL SECTION

SHEET NUMBER WHERE DETAIL IS DRAWN

A1

A-501

SHEET NUMBER WHERE SECTION DRAWN

BUILDING SECTIONA1

A-301

A

BA-401

C

D

PARTITION TYPE;

SEE A37 TO A44

TYP INT

ELEVATION

REFERENCE

WINDOW ID

DOOR ID:

A

COLUMN GRID LINE

SHEET NUMBER WHERE

DETAIL IS DRAWN

PLAN DETAIL REFERENCEA1

A-501

NORTH ARROW

A1

A-201

BUILDING ELEVATION

LEGEND

EXISTING WALL

EXISTING WALL W/ NEW R-19 INSULATION

NEW WALL

1A

NEW WALL W/ R-19 INSULATION

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A8

FIRST FLOOR PLAN

GM,

JS,

GM

4/12/2024

A

C

BD

INT

ELEV

0 8' 16' 24' 3/32" = 1'-0"A8

FLOOR PLANA1

FLOOR PLAN NOTES:

DN

ALL DIMENSIONS FOR NEW WALLS ARE TO FACE OF STUD, UNO.

DIMENSIONS TO EXIST WALLS ARE TO FINISH FACE, UNO.

NON-BEARING INTERIOR PARTITIONS SHALL BE 2 X 4 WD STUDS, AT

16" OC WITH 1/2" GYPBD ON EACH SIDE, UNO.

PROVIDE R-19 INSULATION AT ALL EXTERIOR WALLS THAT

SEPARATE CONDITIONED AND NON CONDITIONED SPACES.

REPLACE SILL TO MATCH EXIST.

1.

2.

3.

4.

WALL SECTION OR

DETAIL SECTION

SHEET NUMBER WHERE DETAIL IS DRAWN

A1

A-501

SHEET NUMBER WHERE SECTION DRAWN

BUILDING SECTIONA1

A-301

101A

A

BA-401

C

D

ROOM NAME & NUMBER

PARTITION TYPE;

SEE 01-A530s

TYP INT

ELEVATION

REFERENCE

ROOM NAME

WINDOW ID: TYPE

DOOR ID:

("ROOM NUMBER, DOOR A")

A

COLUMN GRID LINE

SHEET NUMBER WHERE

DETAIL IS DRAWN

PLAN DETAIL REFERENCEA1

A-501

NORTH ARROW

A1

A-201

BUILDING ELEVATION

LEGEND

EXISTING WALL

EXISTING WALL W/

NEW R-19 INSULATION

NEW WALL

NEW WALL W/ R-19

INSULATION

FIRE SPRINKLER HEAD,

SEE FIRE PROTECTION

LIGHT FIXTURE, SEE ELEC

LIGHT FIXTURE, SEE ELEC

LIGHT FIXTURE, SEE ELEC

LIGHT FIXTURE, SEE ELEC

LIGHT FIXTURE, SEE ELEC

LIGHT FIXTURE, SEE ELEC

CEILING HEIGHT

IDENTIFICATION

9' - 0"

LIGHT TUBE

X9

XA

XB

XC

X8X6 X7

124 SF

NEW

HALLWAY

165 SF

BREAKROOM

UTILITY

44 SF

RR A

RR B

OFFICE

OFFICE

MAIL ROOM

RANGER ROOM

(E) HALLWAY

10' - 0 5/8" 4' - 1 1/2"

5'

/4

3' - 11" 5'

/4

3'

/8

5'

/8

0" 5'

/4

1' - 10 1/2"

A1

A36

A3

A36

2'

/4

A

LI

G N

A

LI

G N

(N) 6X6 POST TO

REPLACE EXIST

A

LI

G N

30 SF

LACTATION

RM

BLOCK IN WDW

SEE &

NEW STAIR TO BASEMENT

CONC SLAB ABV (N) STAIR

HALF SUSAN

157A

NO WORK EXCEPT FIRE

SPRINKLERS, SEE FIRE

PROTECTION

NO WORK EXCEPT FIRE

SPRINKLERS, SEE FIRE

PROTECTION

NO WORK EXCEPT FIRE

SPRINKLERS, SEE FIRE

PROTECTION

NO WORK EXCEPT FIRE

SPRINKLERS, SEE FIRE

PROTECTION

1'

1/ 2"

LINE WALLS W/ FRP PANELS

C2

A47

144 143

A4

A36

CENTER SINK W/

EXIST WDW

M

IN

C

LR

1'

0"

SHELF, SEE &/C1 A48 /A1 A48

BUILD OUT WALL

TO BE FLUSH W/

WDW BLOCKING

/B4 A35/A4 A35

X9

XA

XB

XC

X8X6 X7

9' - 0"

BREAKROOM

GYPBD

9' - 0"

RR A

GYPBD

9' - 0"

LACTATION

RM

GYBD

9' - 0"

OFFICE

EXIST

9' - 0"

OFFICE

EXIST

9' - 0"

RANGER

ROOM

EXIST

9' - 0"

MAIL ROOM

EXIST

9' - 0"

(E) HALLWAY

GYPBD

9' - 0"

NEW

HALLWAY

GYPBD

9' - 0"

RR B

GYPBD

9' - 0"

UTILITY

GYPBD

E Q

E Q

1'

/8

EQ EQ

10' - 6" 7' - 6"

7' - 6" 7' - 6"

E Q

E Q

12' - 0"

3' - 0 5/8" 2' - 10"

2'

/8

2'

/4

2'

/8

2'

/4

1' - 6"

1' - 0"

4'

/4

5'

/2

5'

/4

6'

/2

5'

5'

/4

2'

2'

2' - 9 5/8"

E Q

E Q

EQ EQ

E Q

E Q

E Q

E Q 2' - 6 1/4" 7' - 3 1/2" 7' - 3 1/2"

3' - 0" 4' - 0 5/8" 3' - 0"

4' - 9"

2'

/4

2'

E Q

E Q

2'

/2

1' - 10" 1' - 10"

11 1/2"

NOTES:

SEE ELEC FOR LIGHTING &

POWER PLAN

SEE FA FOR FIRE ALARMS

SEE FP FOR FIRE PROTECTION

SEE MECH FOR HVAC

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A20

ENLARGED FLOOR PLANS -

OFFICES

GM, AA

JS, AA

GM

4/12/2024

ENLARGED FLOOR PLAN NOTES:

1/4" = 1'-0"A20

ENLARGED PLAN - OFFICESA1

1/4" = 1'-0"A20

CEILING PLAN - OFFICESA3

A

C

BD

INT

ELEV

0 2' 4' 8'

0 2' 4' 8'

ENLARGED REFLECTED

X9 R1 R2

RE

RD

RC

RA

1'

/2

/4

/2

11' - 3 3/4" 38' - 8"

15' - 5" 3' - 7" 16' - 1 3/4" 3' - 6 1/4"

3/ 4"

6'

3/ 4"

/4

9'

9' - 5" 5' - 9" 10' - 3 3/4" 13' - 2 1/4"

4' - 5" 5' - 0" 6' - 0"

4' - 6" 8' - 2"

MENS

WOMENS

JANITORIAL

UNISEX

1' - 11 3/4" 1' - 9 1/2"

2'

1/ 2"

FD FD

FD

164 165

1'

/2

6'

1'

/2

1' - 1 1/2"

12' - 5 3/8" 10' - 0" 16' - 2 5/8"

1' - 1 1/2"

1'

/2

1'

/2

1'

/2

1' - 1 1/2"

2'

1/ 2"

DRINKING

FOUNTAIN

& BOTTLE

FILLER

BABY CHANGING

STATION, TYP

FOR 2

SOAP

FAUCET

PTD/WR, TYP

FOR 3

WALL MTD ADULT

CHANGING

STATION

LOUVER

RAINSCREENS

STONE KNEE WALL

CONC SILL

/4

C J

ALIGN

CENTER VENT BTWN WALLS, SEE MECH

1' - 6"

C J C J

C J

C J

C J

5'

5'

C J

C J

C J

C J C J

C JC J

C J C J

C J

WALL MTD

HAND DRYER,

TYP FOR 7

SHELF,

SEE

/C2 A48 /A2 A48

COMFORT STATION LANAI

A32

C4

8'

7"

5' - 6"

7" 8'

2' - 9"

ALL DIMENSIONS FOR NEW WALLS ARE TO FACE OF STUD, UNO.

DIMENSIONS TO EXIST WALLS ARE TO FINISH FACE, UNO.

NON-BEARING INTERIOR PARTITIONS SHALL BE 2 X 4 WD STUDS, AT

16" OC WITH 1/2" GYPBD ON EACH SIDE, UNO.

PROVIDE R-19 INSULATION AT ALL EXTERIOR WALLS THAT

SEPARATE CONDITIONED AND NON CONDITIONED SPACES.

REPLACE SILL TO MATCH EXIST.

1.

2.

3.

4.

WALL SECTION OR

DETAIL SECTION

SHEET NUMBER WHERE DETAIL IS DRAWN

A1

A-501

SHEET NUMBER WHERE SECTION DRAWN

BUILDING SECTIONA1

A-301

101A

A

BA-401

C

D

ROOM NAME & NUMBER

PARTITION TYPE;

SEE A37 TO A44

TYP INT

ELEVATION

REFERENCE

ROOM NAME

WINDOW ID

DOOR ID

A

COLUMN GRID LINE

SHEET NUMBER WHERE

DETAIL IS DRAWN

PLAN DETAIL REFERENCEA1

A-501

NORTH ARROW

A1

A-201

BUILDING ELEVATION

LEGEND

1A

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A22

ENLARGED FLOOR PLANS -

COMFORT STATION

GM, AA

JS, AA

GM

4/12/2024

ENLARGED FLOOR PLAN NOTES:

1/4" = 1'-0"A22

ENLARGED PLAN - COMFORT STATIONA1

A

C

BD

INT

ELEV

0 2' 4' 8'

2'

0"

1'

3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 6' - 0 1/4"

1' - 6" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 1' - 5"SEMI-RECESSED

PTD/WR

DECORATIVE TILE

SOLID SURFACE7' - 3 3/4"

WALL MTD

HAND DRYER

RECESSED TP, SANITARY

NAPKIN DISPOSAL, AND SCD

5' - 3" 5' - 0"

1"

3' - 5 1/2" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4"

3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 1' - 6"

2' - 6" 2' - 6" 2' - 0"

PLUMBING

GUARD

FAUCET

SOAP

MIRROR,

24" X 48", TYP

A1

A45

2'

" 5"

1"1"

1'

1'

WALL MTD HAND DRYERS

PAPER TOWEL DISPENSER

& RECESSED WASTE

RECEPTACLE (PTDWR)

R E

A C

H

4' -0

M

A X

4'-0" 3'-0"

7" - 9"

M

IN

1' -4

6"

16" - 18"

T O

T O

P O

F G

B

T O

6"

T O

T O

P O

F G

B

T O

6"

TYPICAL SIDE ELEVATION

AT ACCESSIBLE TOILET

TYPICAL FRONT ELEVATION

AT ACCESSIBLE TOILET

2' -1

0" M

A X

R E

F

LE

C T

IV

E

S U

R F

A C

E

3' -4

M

A X

T O

T O

C O

N T

R O

L

4' -0

M

A X

FRONT ELEVATION AT

LAVATORY

SIDE ELEVATION

AT LAVATORY

S E

A T

H G

T

SS SIDE SPLASH

AT WALLS

PROVIDE ADA COMPLIANT

PROTECTIVE JACKET OVER ALL

EXPOSED WATER & DRAIN PIPES

6' -2

M

IN

MIN

1'-0"

MIN

2'-0"

4'-6" MIN

2" C

LR

AUTOMATIC FLUSH

VALVE SENSOR

WO. COORDINATE

MOUNTING HEIGHT

WITH GRAB BAR TO

INSURE PROPER

FUNCTION

NOTE:

ALL DIMENSIONS ARE TAKEN TO FINISH FACE OF WALL OR FLOOR

FIXTURES SHOWN TO ILLUSTRATE MOUNTING HEIGHT REQUIREMENTS.

REFER TO DRAWINGS AND SPECIFICATIONS FOR FIXTURE TYPE.

1.

2.

OPEN

1' - 5"

7' - 5 1/2"

BABY CHANGING STATION

DECORATIVE TILE BANDS, TYP

OPEN

RECESSED TP,

SANITARY NAPKIN

DISPOSAL, AND SCD

5' - 0"

RECESSED TP, SANITARY

NAPKIN DISPOSAL, AND SCD

SOLID

SURFACE

DECORATIVE

TILE BANDS, TYP

5' - 3"

SEMI-RECESSED PTD/WR3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4"1' - 6 3/4"

7' - 3 3/4"

1' - 5"

5' - 3" 3' - 1 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4"

1' - 5"

DECORATIVE TILE

WALL MTD

HAND DRYER

SOLID

SURFACE

DECORATIVE TILE

5" 1"1"

2'

1'

"1

OPEN

3' - 0" 3' - 0" 3' - 0" 3' - 0" 2' - 10"

FAUCET

SOAP

BABY CHANGING

STATION

2' - 0"

2' - 6" 2' - 6" 1' - 11"MIRROR, 24" X 48", TYP

PLUMBING

GUARDA3

A45

MIRROR

2' - 0"PLUMBING GUARD

2' - 0"

SEMI-RECESSED

PTD/WR

SOLID SURFACE

4' - 3 1/2"

GYPBD

WALL MTD

HAND DRYER

WALL MTD ADULT

CHANGING STATION

3' - 0"

RECESSED TP,

SANITARY NAPKIN

DISPOSAL, AND SCD

DECORATIVE TILE

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A24

INTERIOR ELEVATIONS

GM, AA

AA, SC

GM

4/12/2024

0 2' 4' 8'

TYPICAL MOUNTING HEIGHTS:

A

C

BD

INT

ELEV

1/4" = 1'-0"A24

WOMENS RESTROOMA1

C1 C2 D

A1 A2 B

1/4" = 1'-0"A24

MENS RESTROOMC1

C1 D

A B

1/4" = 1'-0"A24

UNISEX RESTROOMC3

A CB D

0 2' 4' 8'

0 2' 4' 8'

C2

VENT BEYOND,

SEE MECH

MOP SINK

FRP

OPEN TO

PLUMBING CHASE

5'

MOP RACK

PLUMBING CHASE, NO FINISH FRP

FRP

PLUMBING CHASE, NO FINISH

2'

4'

1/ 2"

A2

A48

5' - 6" 3"

C2

A48

2'

0"

2' - 0"

HALF SUSAN

4' - 0"

2' - 6"4' - 9"2' - 9"

ELEC EQUIP,

SEE ELEC

5' - 7"

MIN 4' - 1" CLR

2' - 0" 2' - 9"

FILLER

2' - 0"

CENTER SINK W/ (E) WDW (E) WDW

2' - 0" 2' - 0"

FRP, TYP IN UTILITY

5'

MOP RACK

4' - 6" 5"

A1

A48

C1

A48

3'

3'

BASE AS

SCHED

RECESSED PTD/WR

1' - 0"

CENTER MIRROR

& LIGHT W/ SINK

2' - 3" RECESSED TP,

SANITARY NAPKIN

DISPOSAL, AND SCD

(E) WDW

A4

A35

B4

A35

OPEN TO STAIR

BEYOND

OPEN TO

(E) HALLWAY

WOOD WALL CAPREUSE HISTORIC WAINSCOT,

TYP IN NEW HALLWAY

W A

IN

S

C O

T H

T

M A

T C

H E

X

IS

T

FLUSH

TRANSITION

SALVAGED HISTORIC DOOR (E) DOOR (N) DOOR

(N) WALL

2' - 9"

REUSE HISTORIC WAINSCOT

GYPBD, PAINTED

W A

IN

S

C O

T H

T

M A

T C

H E

X

IS

T

12' - 9"

FIRE ALARM CONTROL

PANEL, SEE FA

ELEC PANELS,

SEE ELEC

SALVAGED HISTORIC DOOR156

BASE AS SCHED, TYP 157A

EQEQ

WALL MTD SHELVES

WALL MTD COUNTER

C5

A47

C4

A47

OUTLET, SEE ELEC

PULL STATION, SEE FA

COMM OUTLET, SEE TECH

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A25

INTERIOR ELEVATIONS

GM, AA

AA, SC

GM

4/12/2024

A

C

A A

0 2' 4' 8' 1/4" = 1'-0"A25

COMFORT STATION JANITORIALC1

B

D

1/4" = 1'-0"A25

BREAKROOM (117)D3

1/4" = 1'-0"A25

UTILITYC4

A

C

B

D

1/4" = 1'-0"A25

OFFICE RESTROOM AA1

0 2' 4' 8'

1/4" = 1'-0"A25

NEW HALLWAYA2

C

A B

D

0 2' 4' 8'

0 2' 4' 8'

B

0 2' 4' 8'

C D

C

1/4" = 1'-0"A25

LACTATION ROOMC3

0 2' 4' 8'

D

A B C D

INTERIOR

ELEVATION KEY

GYPBD WALLS, TYP

15' - 10"

18' - 8" 9' - 9"

11' - 9" (N) DOOR TO COMFORT STATION

SALVAGED HISTORIC DOOR

160A 5' - 9"

3' - 9"

(E) WDWS

3' - 0" 23' - 5"

5' - 4" 18' - 4"

OPEN TO

LOBBY BEYOND

ROLL-DOWN GRILLE

HEAD SOFFIT

4' - 9" 5' - 3"

12' - 0"

FLUSH TRANSITION

OPEN TO

(E) HALLWAY

NEW STL PIPE HANDRAIL,

BOTH SIDES

OPEN TO NEW

HALLWAY BEYOND

7'

FLUSH

TRANSITION

WOOD WALL CAP

OPEN

C2

A47

W A

IN

S

C O

T H

T

M A

T C

H E

X

IS

T

REUSE HISTORIC WAINSCOT

1X TRIM, STAIN TO

MATCH WAINSCOT,

ALIGN WITH EDGE

OF STEP

C1

A47

NEW HALLWAY

DOOR BEYOND

BASE AS

SCHED

CENTER MIRROR

& LIGHT W/ SINK

EQ EQ

3' - 0" RECESSED PTD/WR

1' - 0" RECESSED TP, SANITARY

NAPKIN DISPOSAL, AND SCD

GRAB BARS

OPEN

BASE AS SCHED

5' - 8"

A25

A2

A25

D3SALVAGED HISTORIC

DOOR BEYOND

EXIST DR

156 157A 158

OUTLET, SEE ELEC

PULL STATION, SEE FA

COMM OUTLET, SEE TECH

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/1

/2

:2 :4

A

M C

U s e rs

\j s \D o c u m e n ts

\2 C

.A L T

E R

N A

T E

H

A V

O V

C R je n n a K

R

T .r v t

A26

INTERIOR ELEVATIONS

GM, AA

AA, SC

GM

4/12/2024

C

A

1/4" = 1'-0"A26

PARK STOREA1

0 2' 4' 8'

1/4" = 1'-0"A26

NEW STAIRC1

A DC

0 2' 4' 8'

B

D

1/4" = 1'-0"A26

OFFICE RESTROOM BA4

1/4" = 1'-0"A26

EXIST HALLWAYC4

A B

C D

0 2' 4' 8'

0 2' 4' 8'

C

D

INTERIOR

ELEVATION KEY

Sheets
A8 - FIRST FLOOR PLAN
A20 - ENLARGED FLOOR PLANS - OFFICES
A22 - ENLARGED FLOOR PLANS - COMFORT STATION
A24 - INTERIOR ELEVATIONS
A25 - INTERIOR ELEVATIONS
A26 - INTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .