This document is a technical specification for stile and rail wood doors, part of a larger federal contract opportunity. The specification covers key requirements for the wood doors, including submittals, delivery and handling, performance standards, and installation. The doors must be fabricated from paint grade material and comply with manufacturer's written instructions. The doors are part of the HAVO 305150 Phase II project to repair and replace infrastructure at the Kilauea Visitor Center in Hawaii Volcanoes National Park. The overall project includes rehabilitation of the existing visitor center, demolition and replacement of an adjacent comfort station, and expansion of the visitor center lanai. This technical specification does not contain pricing, set-asides, award dates, or other procurement-specific details, but rather outlines the technical requirements for the wood doors.
View the file
Other files
Show 40 more
Latest 50 of 72 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HAVO - 305150 08 14 33
STILE AND RAIL WOOD DOORS
SECTION 08 14 33 - STILE AND RAIL WOOD DOORS
PART 1 - GENERAL
1.1 SUBMITTALS
A. Product data
1.2 DELIVERY, STORAGE, AND HANDLING
B. Comply with requirements of referenced standard and manufacturer's written instructions.
C. Package doors individually in opaque plastic bags or cardboard cartons.
D. Mark each door on bottom rail with opening number used on Shop Drawings.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations:
1. Obtain stile and rail wood doors from single manufacturer.
2.2 PERFORMANCE REQUIREMENTS
A. Doors shall be fabricated from paint grade material, smooth finished, to be painted.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine doors and installed door frames, with Installer present, before hanging doors.
1. Verify that installed frames comply with indicated requirements for type, size, location, and swing characteristics and have been installed with level heads and plumb jambs.
2. Reject doors with defects.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Hardware: For installation, see Section 087100 "Door Hardware."
danah.palik Cloud
HAVO - 305150 08 14 33
STILE AND RAIL WOOD DOORS
B. Install doors to comply with manufacturer's written instructions and referenced quality standard, and as indicated.
1. Install frames level, plumb, true, and straight.
2. Shim as required with concealed shims. Install level and plumb to a tolerance of 1/8 inch in 96 inches.
3. Anchor frames to anchors or blocking built in or directly attached to substrates.
a. Secure with countersunk, concealed fasteners and blind nailing.
b. Use fine stainless steel finishing nails or finishing screws for exposed fastening, countersunk and filled flush with woodwork.
C. Job-Fitted Doors:
1. Align and fit doors in frames with uniform clearances and bevels as indicated below.
a. Do not trim stiles and rails in excess of limits set by manufacturer or permitted for fire-rated doors.
2. Machine doors for hardware.
3. Seal edges of doors, edges of cutouts, and mortises after fitting and machining.
4. Clearances:
1. Provide 1/8 inch at heads, jambs, and between pairs of doors.
2. Provide 1/4 inch from bottom of door to top of finished floor unless otherwise indicated on Drawings.
5. Bevel doors 1/8 inch in 2 inches at lock edges.
3.3 ADJUSTING
A. Operation: Rehang or replace doors that do not swing or operate freely.
B. Finished Doors: Replace doors that are damaged or do not comply with requirements. Doors may be repaired or refinished if Work complies with requirements and shows no evidence of repair or refinishing.
END OF SECTION