Attachment_19_-_R1_A49_CD_HAVO_KVC_0006.pdf

PDF 91 KB Posted

Attached to
HAVO 305150 Phase II, Kilauea Visitor Center (KVC)
Solicitation number
140P2024R0114
Issued by

About this file

This document is a door schedule and legend that provides details about the doors to be used in the Kilauea Visitor Center (KVC) renovation project at Hawaii Volcanoes National Park.

The door schedule specifies the door type, mark, width, height, thickness, and remarks for each door, including information about historic doors to be salvaged and reused. The legend provides additional details about the various door types, such as full glazed wood entry doors, flush solid core wood doors, and roll-down grilles. The document also includes a note about determining if doors are left or right-handed based on the floor plan. This information is relevant to the federal contract opportunity for the HAVO 305150 Phase II project, which involves the rehabilitation of the existing KVC and other site improvements.

View the file

Other files

File Type Posted
B08_Attachment_6_HAVO_305150_Wage_Determination_9_6_2024_0009.pdf PDF
Sol_140P2024R0114_Amd_0009.pdf PDF
B09_Attachment_25_-_Amd_08_Solicitation_QA_HAVO_305150_0008.xlsx XLSX spreadsheet
Sol_140P2024R0114_Amd_0008.pdf PDF
B09_Attachment_51_-_A8-A20-A22-A24-A25-A26_REV_0008.pdf PDF
B09_Attachment_48_-_C9_WATER_PLAN_AND_PROFILE_II_REV_0007.pdf PDF
B09_Attachment_36_-_08_31_13_-_ACCESS_DOORS_AND_FRAMES_0007.pdf PDF
B09_Attachment_30_-_08_14_33_-_STILE_AND_RAIL_WOOD_DOORS_0007.pdf PDF
B09_Attachment_41_-_09_29_00_-_GYPSUM_BOARD_0007.pdf PDF
B08_Attachment_6_HAVO_305150_Wage_Determination_7_19_2024_0007.pdf PDF
B09_Attachment_38_-_08_80_00_-_GLAZING_0007.pdf PDF
B09_Attachment_46_-_A22-A28-A51_REV_0007.pdf PDF
B09_Attachment_44_-_10_28_00_-_TOILET_ACCESSORIES_0007.pdf PDF
B09_Attachment_43_-_09_51_13_-_ACOUSTICAL_PANEL_CEILINGS_0007.pdf PDF
B09_Attachment_32_-_06_20_13_-_Exterior_Finish_Carpentry_0007.pdf PDF
B09_Attachment_40_-_08_91_19_-_FIXED_LOUVERS_0007.pdf PDF
B09_Attachment_47_-_C6_C11_C16_REV_0007.pdf PDF
B09_Attachment_49_-_E15_REV_0007.pdf PDF
B09_Attachment_28_-_07_92_00_-_Joint_Sealants_0007.pdf PDF
B09_Attachment_50_-_E25_REV_0007.pdf PDF
B09_Attachment_29_-_08_12_13_-_Hollow_Metal_Frames_0007.pdf PDF
B09_Attachment_37_-_08_71_00_-_Door_Hardware_0007.pdf PDF
B09_Attachment_25_-_Amd_07_Solicitation_QA_HAVO_305150_0007.xlsx XLSX spreadsheet
B09_Attachment_35_-_07_72_00_-_Roof_Accessories_0007.pdf PDF
B09_Attachment_34_-_07_62_00_-_Sheet_Metal_Flashing_and_Trim_0007.pdf PDF
B09_Attachment_33_-_07_21_00_-_Thermal_Insulation_0007.pdf PDF
B09_Attachment_42_-_09_30_13_-_CERAMIC_TILING_0007.pdf PDF
B09_Attachment_31_-_01_77_00A_Closeout-OperationMaintenance-Requirements_0007.pdf PDF
B09_Attachment_39_-_08_83_00_-_MIRRORS_0007.pdf PDF
Sol_140P2024R0114_Amd_0007.pdf PDF
B09_Attachment_45_-_33_14_16___Site_Water_Utility_Distribution_0007.pdf PDF
B09_Attachment_27_-_01_33_23-A_SubmittalList-ReviewEstimate_0007.pdf PDF
B09_Attachment_26_-_00_-_Table_of_Contents_0007.pdf PDF
Attachment_23_-_Pre-proposal_Site_Visit_Sign-in_Roster_7_31_2024_0006.pdf PDF
Attachment_21_-_01_33_23-A_SubmittalList-ReviewEstimate_0006.pdf PDF
Attachment_18_-_R1_A42_CD_HAVO_KVC_0006.pdf PDF
Attachment_24_-_HAVO_305150B_Prebid_Meeting_Notes_7-31-24_0006.pdf PDF
Attachment_17_-_R1_A36_CD_HAVO_KVC_0006.pdf PDF
Sol_140P2024R0114_Amd_0006.pdf PDF
Attachment_25_-_Amd_06_Solicitation_QA_HAVO_305150_0006.xlsx XLSX spreadsheet
Attachment_22_-_01_77_00A_Closeout-OperationMaintenance-Requirements_0006.pdf PDF
Attachment_20_-_SECTION_08_71_00_-_DOOR_HARDWARE_-_REV_2_0006.pdf PDF
Sol_140P2024R0114_Amd_0005.pdf PDF
B09_Attachment_15_-_Cold_Fluid-Applied_Waterproofing-rev1_07_14_16_0004.pdf PDF
B09_Attachment_16_-_S1_Basement-81_0004.pdf PDF
Sol_140P2024R0114_Amd_0004.pdf PDF
Sol_140P2024R0114_Amd_0003.pdf PDF
B09_Attachment_14_-_Site_Visit_Tri_Fold_HAVO_305150B_-_AMENDMENT_3_0003.pdf PDF
B09_Attachment_13_-_HAVO_305150_Prebid_Site_Visit_Insructions_0003.pdf PDF
B08_Attachment_2_HAVO305150_FinalCDDrawings_0002.pdf PDF
Show 40 more

Latest 50 of 72 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES:

REFER TO THE FLOOR PLAN TO DETERMINE IF

DOOR IS LEFT HANDED OR RIGHT HANDED.

EXISTING HARDWARE TO REMAIN SHALL BE HDW

TYPE E IN SCHED.

1.

2.

FINISH FLOOR

D

FULL GLAZED PAIR WOOD

ENTRY DOOR WITH

SAFETY GLAZING

B

FLUSH SOLID CORE

WOOD DOOR

FINISH FLOOR

A

(E) SINGLE PANEL

WOOD DOOR

FINISH FLOOR

C

(E) PNL DOOR W/

TOP GLASS PNL

E

MISCELLANEOUS

EXISTING TO REMAIN

H

W W

H H

W

W

H

H

W

GRILLE HOUSING ABV

H

W

G

ROLL-DOWN GRILLE

H

DOOR OPENING

W

H

F

WOOD DOOR, SEE

DETAILS ON A34

W

HH

H

I

FLUSH SOLID CORE

WOOD DOOR W/

NARROW VISION LIGHT

W

H

FINISH FLOOR

J

PAIR FLUSH SOLID

CORE WOOD DOORS

W

H

This work was prepared by me or under my supervision.

Signature Expiration Date of License

4/30/2026

No. 4073

W

N

ARCHITECT

PROFESSIONAL

LICENSED

A

H

NEL

G

A

,IIA S.

U.

NO

ME. AS

OF

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.

HAWAII VOLCANOES NATIONAL PARK

KILAUEA VISITOR CENTER

DESIGNED:

CADD:

TECH REVIEW:

DATE:

187007

SHEET

HAVO 305150B

/2

/2

:4 :3

P

M C U s e r s js

D o c u m e n t s C .A

L T E R N A T E H A V O V C R je n n a K R T .r v t

A49

DOOR SCHEDULE AND

LEGEND

GM, AA

JS, AA

GM

4/12/2024 78

DOOR TYPES

DOOR SCHEDULE DOOR NOTES

NUMBER TYPE MARK WIDTH HEIGHT THICKNESS REMARKS

114 S 2' - 6" 7' - 0" 1 3/8" HISTORIC GLASS PANEL DOOR.

115 S 2' - 6" 7' - 0" 1 3/8" HISTORIC SINGLE PANEL DOOR.

116 S 2' - 2" 7' - 0" 1 3/8" HISTORIC DOOR W/ LOUVER.

117 S 2' - 2" 7' - 0" 1 3/8" HISTORIC DOOR W/ LOUVER.

118 S 2' - 2" 7' - 0" 1 3/8" HISTORIC SINGLE PANEL DOOR.

131 S 2' - 6" 7' - 0" 1 3/8" HISTORIC SINGLE PANEL DOOR.

137 S VIF 7' - 0" 1 3/8" HISTORIC SINGLE PANEL DOOR. VIF WIDTH

IN FIELD FOR POSSIBLE REUSE.

HISTORIC DOOR SCHEDULE

NOTES:

1. PARK TO DETERMINE WHICH, IF ANY, OF THE HISTORIC DOORS IN THE HISTORIC DOOR SCHEDULE SHOULD BE

SALVAGED AND STORED.

2. HISTORIC DOORS 113, 119, AND 130 SCHEDULED FOR REUSE IN DOOR SCHEDULE.

NUMBER TYPE MARK HDW SET WIDTH HEIGHT THICKNESS REMARKS

1 E E

2 E E

3 E E

4 E E

5 E E

6 E E

7 E E

8 E E

9 E E

10 E E

13 H - 3' - 0" 7' - 0" NO DOOR, NO HARDWARE.

108 E 02

121 E E

122 A 07 3' - 0" 7' - 0" 1 3/8" REPLACE LOCKSET.

123 H - NO DOOR, NO HARDWARE.

125 C 07 2' - 6" 7' - 0" 1 3/8" REUSE SALVAGED DOOR 113, REPLACE LOCKSET.

127 C 07 3' - 0" 7' - 0" 1 3/8" REPLACE LOCKSET.

140 E 07

141 E E

142 E E

143 E E

144 E E

145 E E PAINT (E) LOUVER.

146 E E

147 E E

148 E E

151 E E

154 D 01 6' - 0" 7' - 0" 2"

155 B 02 4' - 0" 7' - 0" 1 3/4"

156 C 07 3' - 0" 7' - 0" 1 3/8" REUSE SALVAGED DOOR 119.

157 A 08 3' - 0" 7' - 0" 1 3/8"

157A A 08 3' - 0" 7' - 0" 1 3/8" REUSE SALVAGED DOOR 137 IF 3' - 0" WIDTH.

158 A 04 2' - 8" 7' - 0" 1 3/8"

159 A 08 3' - 0" 7' - 0" 1 3/8"

160 I 07 3' - 6" 7' - 0" 1 3/4"

160A C 07 3' - 6" 7' - 0" 1 3/4" REUSE SALVAGED DOOR 130, INSTALL OBSCURE FILM ON GLASS ON

PARK STORE STORAGE SIDE.

161 D 01 6' - 0" 7' - 0" 2"

162 G - 10' - 0" 7' - 0" NO HARDWARE

163 F 09 4' - 10" 7' - 9 3/4" 3"

164 B 05 3' - 0" 7' - 9 3/4" 1 3/4"

165 B 08 3' - 0" 7' - 9 3/4" 1 3/4"

166 F 09 4' - 10" 7' - 9 3/4" 3"

167 B 10 3' - 0" 7' - 0" 1 3/4"

G2 E E

G3 H - NO DOOR, NO HARDWARE.

G4 J 03 6' - 0" 7' - 0" 1 3/4"

N101 D 01 6' - 0" 7' - 0" 2"

Sheets
A49 - DOOR SCHEDULE AND LEGEND