The document covers coordination, submittals, and requirements for door hardware, including hinges, locks, exit devices, closers, and operators. It specifies performance requirements such as accessibility standards, keying requirements, and installation instructions. It provides a detailed hardware schedule that lists the door hardware sets to be provided for different door types, including entrances, storage rooms, the generator building, electric room, janitor room, and exterior doors. The project is being implemented by the Department of the Interior National Park Service National Office.
View the file
Other files
Show 40 more
Latest 50 of 72 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HAVO – 305150B 08 71 00- 1
081324 DOOR HARDWARE
SECTION 08 71 00 – DOOR HARDWARE
PART 1 - GENERAL
1.1 COORDINATION
A. Installation Templates: Distribute for doors, frames, and other work specified to be factory prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.
B. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.
C. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.
1.2 SUBMITTALS
A. Product literature
B. Hardware schedule showing hardware products being provided for each door.
C. Keys
1.3 DELIVERY, STORAGE, AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site.
B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package.
C. Deliver keys to manufacturer of key control system for subsequent delivery to Contracting Officer.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations: Obtain each type of door hardware from single manufacturer.
1. Provide electrified door hardware from same manufacturer as mechanical door hardware unless otherwise indicated. Manufacturers that perform electrical modifications and that danah.palik Cloud
HAVO – 305150B 08 71 00- 2
are listed by a testing and inspecting agency acceptable to authorities having jurisdiction are acceptable.
2.2 PERFORMANCE REQUIREMENTS
A. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.
B. Means of Egress Doors: Latches do not require more than 15 lbf to release the latch. Locks do not require use of a key, tool, or special knowledge for operation.
C. Accessibility Requirements: For door hardware on doors in an accessible route, comply with the USDOJ's "2010 ADA Standards for Accessible Design”.
1. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 lbf.
2. Comply with the following maximum opening-force requirements:
a. Interior, Non-Fire-Rated Hinged Doors: 5 lbf applied perpendicular to door.
b. Fire Doors: Minimum opening force allowable by authorities having jurisdiction.
3. Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/2 inch high.
4. Adjust door closer sweep periods so that, from an open position of 90 degrees, the door will take at least 5 seconds to move to a position of 12 degrees from the latch.
D. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade name displayed in a visible location except in conjunction with required fire-rating labels and as otherwise approved by Architect.
1. Manufacturer's identification is permitted on rim of lock cylinders only.
E. Base Metals: Produce door hardware units of base metal indicated, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18.
F. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware unless otherwise indicated.
1. Concealed Fasteners: For door hardware units that are exposed when door is closed, except for units already specified with concealed fasteners. Do not use through bolts for installation where bolt head or nut on opposite face is exposed unless it is the only means of securely attaching the door hardware. Where through bolts are used on hollow door and frame construction, provide sleeves for each through bolt.
2. Spacers or Sex Bolts: For through bolting of hollow-metal doors.
HAVO – 305150B 08 71 00- 3
3. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.
2.3 KEYING
A. All door locksets shall be unlocked with the park master key. Master key shall be provided by park.
B. Doors 106, 115, 116, 117 and 118 shall all be keyed alike. Keying shall match keying for other park restrooms. Park to supply key to copy
C. Doors 102, 103 and 104 keyed alike
D. Door 105 and 109 keyed alike
E. Doors 101, 107, 108, 111, 112, 113 and 114 all keyed alike
F. Door 110 keyed separately
G. Door 119 keyed separately
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance of the Work.
B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Steel Doors and Frames: For surface-applied door hardware, drill and tap doors and frames in accordance with ANSI/SDI A250.6.
B. Wood Doors: Comply with door and hardware manufacturers' written instructions.
3.3 INSTALLATION
A. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations.
1. Standard Steel Frames: ANSI/SDI A250.8.
HAVO – 305150B 08 71 00- 4
2. Wood Doors: DHI's "Recommended Locations for Architectural Hardware for Wood Flush Doors."
B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work. Do not install surface-mounted items until finishes have been completed on substrates involved.
1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.
2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.
C. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings.
1. Configuration: Provide one power supply for each door opening indicated with electrified door hardware.
3.4 ADJUSTING
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
1. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.
2. Spring Hinges: Adjust to achieve positive latching when door is allowed to close freely from an open position of 70 degrees and so that closing time complies with accessibility requirements of authorities having jurisdiction.
3.5 CLEANING AND PROTECTION
A. Clean adjacent surfaces soiled by door hardware installation.
B. Clean operating items as necessary to restore proper function and finish.
C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion.
3.6 MAINTENANCE SERVICE
A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.
HAVO – 305150B 08 71 00- 5
3.7 HARDWARE SETS
A. HW-01 (Entrances) – Doors N101, 154, and 161 6 EA Hinges A5111 4.5 x 4.5 NRP 630 2 EA Exit Device Type IV (2890) 630 1 EA Lock X-10 1 EA Cylinder E09211 626 1 Set Flush Bolts L04251 626 2 EA Automatic door openers with push pad switches
B. HW-02 (Storage Rooms) – Doors 108, 155 3 EA Hinges A5133 3.5 x 3.5 630 1 EA Lockset F07 X LEVER 630 1 EA Kickplate J102 8” x 34” 626 1 EA Stop L04251 626
C. HW-03 (Generator Building) – Door G4 6 EA Hinges A5111 4.5 x 4.5 NRP 630 1 EA Lockset F07 X LEVER 630 2 EA Surface Bolts 2 EA Kickplates J102 8” x 34” 626
D. HW-04 (Electric Room) – Door 158 3 EA Hinges A5111 4.5 x 4.5 NRP 630 1 EA Lockset F07 X LEVER 626 1 Set Flush Bolts L04251 626
E. HW-05 (Janitor) – Door 164 3 EA Hinges A5111 3.5 x 3.5 630 1 EA Lockset F07 X LEVER 626 1 EA Stop L04251 626
F. HW-06 Not Used
G. HW-07 (Door to Hall) – Doors 122, 125, 127, 156 3 EA Hinges A5111 3.5 x 3.5 630 1 EA Lockset F07 X LEVER 626 1 EA Stop L04251 626
H. HW-08 (Privacy) – Doors 157, 157a, 159 3 EA Hinges A5111 3.5 x 3.5 630 1 EA Lockset F82 X LEVER 626 1 EA Stop L04251 626
I. HW-09 (Toilet Room Doors) – Doors 163, 166 5 EA Hinges A5111 5 x 5 630 1 EA Lockset F05 X LEVER (provide longer spindle)
1 EA Cane Bolt
HAVO – 305150B 08 71 00- 6
J. HW-10 (Exterior Doors) – Door 167 3 EA Hinges A5133 4.5 x 4.5 630 1 EA Lockset F21 X LEVER 626 1 EA Stop L04251 626 1 EA Closer CO2011 PT4A, B, C, D, F, H FULL COVER
K. HW-11 Not Used
END OF SECTION 08 71 00
| PART 1 - GENERAL |
| 1.1 COORDINATION |
| A. Installation Templates: Distribute for doors, frames, and other work specified to be factory prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated... |
| B. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant. |
| C. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems. |
| 1.2 SUBMITTALS |
| A. Product literature |
| B. Hardware schedule showing hardware products being provided for each door. |
| C. Keys |
| 1.3 DELIVERY, STORAGE, AND HANDLING |
| A. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site. |
| B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. |
| C. Deliver keys to manufacturer of key control system for subsequent delivery to Contracting Officer. |
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS |
| A. Source Limitations: Obtain each type of door hardware from single manufacturer. |
| 1. Provide electrified door hardware from same manufacturer as mechanical door hardware unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities ha... |
| 2.2 pERFORMANCE rEQUIREMENTS |
| A. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. |
| B. Means of Egress Doors: Latches do not require more than 15 lbf to release the latch. Locks do not require use of a key, tool, or special knowledge for operation. |
| C. Accessibility Requirements: For door hardware on doors in an accessible route, comply with the USDOJ's "2010 ADA Standards for Accessible Design”. |
| 1. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 lbf. |
| 2. Comply with the following maximum opening-force requirements: |
| a. Interior, Non-Fire-Rated Hinged Doors: 5 lbf applied perpendicular to door. |
| b. Fire Doors: Minimum opening force allowable by authorities having jurisdiction. |
| 3. Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/2 inch high. |
| 4. Adjust door closer sweep periods so that, from an open position of 90 degrees, the door will take at least 5 seconds to move to a position of 12 degrees from the latch. |
| D. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade name displayed in a visible location except in conjunction with required fire-rating labels and as otherwise approved by Architect. |
| 1. Manufacturer's identification is permitted on rim of lock cylinders only. |
| E. Base Metals: Produce door hardware units of base metal indicated, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of a quality equal to or greater than that of spe... |
| F. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminu... |
| 1. Concealed Fasteners: For door hardware units that are exposed when door is closed, except for units already specified with concealed fasteners. Do not use through bolts for installation where bolt head or nut on opposite face is exposed unless it i... |
| 2. Spacers or Sex Bolts: For through bolting of hollow-metal doors. |
| 3. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere as indicated. |
| 2.3 kEYING |
| A. All door locksets shall be unlocked with the park master key. Master key shall be provided by park. |
| B. Doors 106, 115, 116, 117 and 118 shall all be keyed alike. Keying shall match keying for other park restrooms. Park to supply key to copy |
| C. Doors 102, 103 and 104 keyed alike |
| D. Door 105 and 109 keyed alike |
| E. Doors 101, 107, 108, 111, 112, 113 and 114 all keyed alike |
| F. Door 110 keyed separately |
| G. Door 119 keyed separately |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance of the Work. |
| B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation. |
| C. Proceed with installation only after unsatisfactory conditions have been corrected. |
| 3.2 PREPARATION |
| A. Steel Doors and Frames: For surface-applied door hardware, drill and tap doors and frames in accordance with ANSI/SDI A250.6. |
| B. Wood Doors: Comply with door and hardware manufacturers' written instructions. |
| 3.3 INSTALLATION |
| A. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations. |
| 1. Standard Steel Frames: ANSI/SDI A250.8. |
| 2. Wood Doors: DHI's "Recommended Locations for Architectural Hardware for Wood Flush Doors." |
| B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, s... |
| 1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation. |
| 2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards. |
| C. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings. |
| 1. Configuration: Provide one power supply for each door opening indicated with electrified door hardware. |
| 3.4 aDJUSTING |
| A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate fo... |
| 1. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction. |
| 2. Spring Hinges: Adjust to achieve positive latching when door is allowed to close freely from an open position of 70 degrees and so that closing time complies with accessibility requirements of authorities having jurisdiction. |
| 3.5 CLEANING and Protection |
| A. Clean adjacent surfaces soiled by door hardware installation. |
| B. Clean operating items as necessary to restore proper function and finish. |
| C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion. |
| 3.6 Maintenance Service |
| A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Owner's continued adjustment, maintenance, and removal and replacement of door hardware. |
| 3.7 Hardware Sets |
| A. HW-01 (Entrances) – Doors N101, 154, and 161 |
| B. HW-02 (Storage Rooms) – Doors 108, 155 |
| C. HW-03 (Generator Building) – Door G4 |
| D. HW-04 (Electric Room) – Door 158 |
| E. HW-05 (Janitor) – Door 164 |
| F. HW-06 Not Used |
| G. HW-07 (Door to Hall) – Doors 122, 125, 127, 156 |
| H. HW-08 (Privacy) – Doors 157, 157a, 159 |
| I. HW-09 (Toilet Room Doors) – Doors 163, 166 |
| J. HW-10 (Exterior Doors) – Door 167 |
| K. HW-11 Not Used |