B09_Attachment_36_-_08_31_13_-_ACCESS_DOORS_AND_FRAMES_0007.pdf
PDF 84 KB Posted
- Solicitation number
- 140P2024R0114
About this file
This document is a technical specification for access doors and frames required for the Kilauea Visitor Center (KVC) Phase II project at Hawaii Volcanoes National Park. The specification outlines the performance requirements, including that the access doors must have an exposed flange, stainless steel construction with a brushed finish, and fully concealed hinges. The doors and frames must be fabricated as integral units ready for installation, with smooth, flat metal surfaces. The hardware requirements include providing multiple latches and locks with two keys per lock, keyed alike. The document also includes installation instructions and requirements to examine the substrate and correct any unsatisfactory conditions prior to installation.
View the file
Other files
Show 40 more
Latest 50 of 72 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HAVO - 305150 08 31 13
ACCESS DOORS AND FRAMES
SECTION 08 31 13 - ACCESS DOORS AND FRAMES
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes doors required to provide access for servicing mechanical equipment.
1.2 SUBMITTALS
A. Product data
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Exposed flange
B. Stainless steel for all exposed surfaces, with brushed finish. Door shall be 14 gauge. Frame and trim shall be 16 gauge.
C. Hinges shall be fully concealed.
2.2 FABRICATION
A. General: Provide access door and frame assemblies manufactured as integral units ready for installation.
B. Metal Surfaces: For metal surfaces exposed to view in the completed Work, provide materials with smooth, flat surfaces without blemishes. Do not use materials with exposed pitting, seam marks, roller marks, rolled trade names, or roughness.
C. Doors and Frames: Grind exposed welds smooth and flush with adjacent surfaces. Furnish mounting holes, attachment devices and fasteners of type required to secure access doors to types of supports indicated.
D. Latch and Lock Hardware:
1. Quantity: Furnish number of latches and locks required to hold doors tightly closed.
2. Keys: Furnish two keys per lock and key all locks alike.
danah.palik Cloud
HAVO - 305150 08 31 13
ACCESS DOORS AND FRAMES
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Comply with manufacturer's written instructions for installing access doors and frames.
3.3 ADJUSTING
A. Adjust doors and hardware, after installation, for proper operation.
END OF SECTION