This is a product specification sheet for the Mitsubishi Electric Trane HVAC TLGHF0470RVX02A Energy Recovery Ventilation (ERV) unit. The document provides detailed technical specifications, dimensions, and available accessories for this equipment.

The TLGHF0470RVX02A is a standalone energy recovery ventilation system with a capacity of 470 CFM (799 m³/h) utilizing a Lossnay® cross-flow energy recovery core for minimal cross-contamination between air streams. The unit operates on 208/230V, single phase, 60Hz power with a power consumption range of 0.22-0.425 kW and includes four fan speed settings with an EC motor. The system achieves exchange efficiency ratings of 69-84.5% for temperature transfer and 51-83% for enthalpy depending on fan speed, with sound pressure levels ranging from 20-40 dB(A). External dimensions are 41-3/8" x 51-5/16" x 15-29/32" with a net weight of 110 lbs, and it operates across entering air temperatures of 14-104°F. The unit features a standard MERV 7 non-woven fabric filter and supports optional MERV 14 and MERV 16 filters, M-NET connectivity, and includes a stand-alone remote controller (TZ-62DR-EA) with capabilities for external input bypass damper control. Available accessories include wired remote controllers, duct silencers, various filter options, and CO2 sensors for remote monitoring. The specifications document is subject to change without notice and is current as of June 2022.

View the file

Other files

File Type Posted
S30 - SAM - Special Notice - Cancellation - 36C77626R0062_2 - EHRM Infra Upgrades - Togus.pdf PDF
S06 - Amend 0002 - Att 03 - Corrected Agenda - RFP - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0002 - 36C77626R0062 - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 02 - SV - Attendance SHT - 06292026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - 36C77626R0062 - 07142026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - RFIs - 07132026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S06 - Amend 0001 - Att 01 - Rvd Structural Drwg - 06192026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 03 - SV - Agenda - RFP - 06292026 - EHRM Infra - Togus.pdf PDF
S02 - SOW - Att 05 - Drwg - Vol 3 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 13 - Const Sch - 02132026 - EHRM Infra Upgrades - Constr Togus.pdf PDF
S02 - SOW - Att 26 - Cut Sheet 04 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 03 -Prj Info Sheet for KTR - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 03 - Drwg - Vol 1C - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 22 - TS-000 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 07 - 852.219-75 - 06172026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - Att 04 - Memo - Brand Name - 04092026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - SOW - Att 35 - Cut Sheet 13 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 17 - Memo - Phy Sec Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 27 - Cut Sheet 05 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 09 - Specs - Vol 3- 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 30 - Cut Sheet 08 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 24 - Cut Sheet 02 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 05 - Division Cost Breakdown - EHRM Infra Upgrade - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 29 - Cut Sheet 07 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 37 - Cut Sheet 15 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 16 - Submittal Reg - 02182026 - EHRM Infra - Upgrades - Constr - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 14 - Design Calcs - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 18 - Memo - Prj Stnd Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 21 - PCRA 3 - MCR and Trench Work - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 33 - Cut Sheet 11 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 01 - Drwg - Vol 1A - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 38 - Cut Sheet 16 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 06 - Drwg - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 11 - Haz Mat Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 12 - Geotechnical Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 32 - Cut Sheet 10 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 08 - Specs - Vol 1 - Div 02-14 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 20 - PCRA 2 - Cabling and Data Outlets - EHRM Infra Upgrades - Constr - Togus.pdf PDF
RFP - EHRM Infra Upgrade - 36C77626R0062 - 06172026 - Togus.pdf PDF
S02 - SOW - Att 19 - PCRA 1 - TR Constr - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 07 - Specs - Vol 1 - Div 00-01 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 15 - Design Narrative - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 23 - Cut Sheet 01 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 31 - Cut Sheet 09 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 02 - PPQ - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 02 - Drwg - Vol 1B - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 34 - Cut Sheet 12 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 01 - SOW - 05112026 - EHRM Infra Upgrades - Togus.pdf PDF
S02 - SOW - Att 10 - Specs - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 36 - Cut Sheet 14 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

GENERAL FEATURES

•Lossnay® cross-flow energy recovery core
•Minimal cross contamination between entering and leaving air streams
•Stand-alone remote controller (TZ-62DR-EA)
•M-NET Connectivity
•External input bypass damper control
•Stand alone or interlocks connects with all Mitsubishi Electric products
•Four fan speeds
•High efficiency DC Motor
•Standard MERV 7 non-woven fabric filter, washable fiber
•Optional high-efficiency MERV 14 and MERV 16 filters

Specifications System Unit Type TLGHF0470RVX02A

Capacity CFM [m3/h] 470 [799] Power source 208/230, 1, 60 Power Consumption kW 0.22 - 0.425 Current A 0.047/0.11 Starting Current A 6.1

MCA A 5.1

Maximum Overcurrent Protection (MOCP) A 15

Fan

Air Volume CFM [m3/h] 118- 235-353-470 [ 200-399-599-799] Type x quantity 9-5/8 In. diameter centrifugal fan External Static pressure in.WG 0.06–0.25–0.56–1.0 Motor type EC Motor

Exchange Efficiency Temperature % 69-73-77.5-84.5 Enthalpy Cooling % 51.0-57.0- 64.0- 72.0 Enthalpy Heating % 64.0-69.0-75.0-83.0

External finish Galvanized steel sheet External Dimensions In. [mm] 41-3/8 x 51-5/16 x 15-29/32 [1,051 x 1,302 x 404] Net weight Lbs [kg] 110 [50] Energy Transfer Mechanism Lossnay® Core Heat Exchange Material Partition, spacing plate-cellulose fiber membrane Heat Exchange System Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Blower Type 9-5/8 In. diameter centrifugal fan Entering Air Temperature Operation Range °F [°C] 14 to 104 [ -10 to 40] Sound pressure level dB(A) 40.0–34.0–26.0–20.0

TLGHF0470RVX02A

ENERGY RECOVERY VENTILATION

Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

ACCESSORIES: TLGHF0470RVX02A

Wired Remote Controller Lossnay® ERV Remote Controller TZ-62DR-EA Control Interface Signal Output Terminal PZ-4GS-E Duct Accessories Duct Silencer PZ-250SS-E

Filter

MERV 14 Filter PZ-80RFP-E MERV 16 Filter PZ-80RFP2-E MERV 7 Filter (Included) PZ-80RF9-E

Remote Sensor CO2 Sensor, Built-In PZ-70CSB-E CO2 Sensor, Wall Mount PZ-70CSW-E1

Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

FORM# TLGHF0470RVX02A - 202206Ver2

UNIT SCALE

inch(mm) N.T.S

DIMENSIONS: TLGHF0470RVX02A

Job Name 11:
System Reference 11:
Date 11:
Check Box 8: Off
Check Box 1: Off
Check Box 2: Off
Check Box 3: Off
Check Box 4: Off
Check Box 5: Off
Check Box 6: Off
Check Box 7: Off

File details come from the government source that posted it. Updated .