This document is a product specification sheet for Rheem Professional Classic® tankless electric water heaters for residential applications. The product line includes nine models (RTEX-04, RTEX-06, RTEX-08, RTEX-11, RTEX-13, RTEX-18, RTEX-24, RTEX-27, and RTEX-36) designed to provide on-demand, continuous hot water with digital temperature control adjustable in 1-degree increments ranging from 80°F to 140°F.

The heaters feature robust copper immersion heating elements with brass tops that are field-serviceable, with models varying from single to four heating chambers depending on capacity requirements. Point-of-use models (RTEX-04, RTEX-06) support flow rates of 0.5 to 2.0 GPM and are designed for single applications such as hand sinks and washing machines. Multiple application models (RTEX-08 through RTEX-36) support flow rates up to 6.0 GPM for whole-home applications, with the RTEX-36 providing the highest capacity at 36.0 kW and 150 amperage. All units feature external digital displays with thermostatic control, simple installation with side or bottom NPT water connections, and are certified by the Water Quality Association for lead-free compliance and listed to UL 499 and CSA standards. The warranty includes a 5-year heating chamber and 1-year parts limited warranty. Optional inline flow regulators are available to enhance outlet temperature control, and suggested specifications are provided for procurement purposes.

View the file

Other files

File Type Posted
S30 - SAM - Special Notice - Cancellation - 36C77626R0062_2 - EHRM Infra Upgrades - Togus.pdf PDF
S06 - Amend 0002 - Att 03 - Corrected Agenda - RFP - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0002 - 36C77626R0062 - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 02 - SV - Attendance SHT - 06292026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - 36C77626R0062 - 07142026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - RFIs - 07132026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S06 - Amend 0001 - Att 01 - Rvd Structural Drwg - 06192026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 03 - SV - Agenda - RFP - 06292026 - EHRM Infra - Togus.pdf PDF
S02 - SOW - Att 05 - Drwg - Vol 3 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 13 - Const Sch - 02132026 - EHRM Infra Upgrades - Constr Togus.pdf PDF
S02 - SOW - Att 26 - Cut Sheet 04 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 03 -Prj Info Sheet for KTR - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 03 - Drwg - Vol 1C - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 22 - TS-000 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 07 - 852.219-75 - 06172026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - Att 04 - Memo - Brand Name - 04092026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - SOW - Att 35 - Cut Sheet 13 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 17 - Memo - Phy Sec Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 27 - Cut Sheet 05 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 09 - Specs - Vol 3- 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 30 - Cut Sheet 08 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 24 - Cut Sheet 02 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 05 - Division Cost Breakdown - EHRM Infra Upgrade - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 29 - Cut Sheet 07 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 37 - Cut Sheet 15 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 16 - Submittal Reg - 02182026 - EHRM Infra - Upgrades - Constr - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 14 - Design Calcs - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 18 - Memo - Prj Stnd Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 21 - PCRA 3 - MCR and Trench Work - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 40 - Cut Sheet 18 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 33 - Cut Sheet 11 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 01 - Drwg - Vol 1A - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 38 - Cut Sheet 16 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 06 - Drwg - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 11 - Haz Mat Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 12 - Geotechnical Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 08 - Specs - Vol 1 - Div 02-14 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 20 - PCRA 2 - Cabling and Data Outlets - EHRM Infra Upgrades - Constr - Togus.pdf PDF
RFP - EHRM Infra Upgrade - 36C77626R0062 - 06172026 - Togus.pdf PDF
S02 - SOW - Att 19 - PCRA 1 - TR Constr - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 07 - Specs - Vol 1 - Div 00-01 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 15 - Design Narrative - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 23 - Cut Sheet 01 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 31 - Cut Sheet 09 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 02 - PPQ - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 02 - Drwg - Vol 1B - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 34 - Cut Sheet 12 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 01 - SOW - 05112026 - EHRM Infra Upgrades - Togus.pdf PDF
S02 - SOW - Att 10 - Specs - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 36 - Cut Sheet 14 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Performance Features

• �On demand, consistent and continuous hot water

• �Compact and stylish with digital temperature control in increments of 1° ranging from 80°F to 140°F*

• �Robust copper immersion heating elements with brass top increases durability and are threaded for easy replacement

• �Simple Installation

• �Digital temperature display

• �External controls to adjust temperature in increments of 1°*

Average GPM Usage by Application

Average Gallons Per Minute (GPM) based on 2010 Plumbing Standards

PRINTED IN U.S.A. 12/20 WP FORM NO. TKE-101 Rev. 6

INTEGRATED HOME COMFORTINTEGRATED HOME COMFORT

Professional Classic® tankless electric water heaters offer continuous hot water

Water INTEGRATED HOME COMFORT

Residential Electric Professional Classic Tankless Water Heaters

RTEX-08, RTEX-11, RTEX-13RTEX-04, RTEX-06

Unique Features:

• �External Adjustable Digital

Thermostatic Control with LED display (+/- 1 degree accuracy)

• �Durable Copper Immersion two heating elements, field serviceable

• �Simple Installation – Side 1/2" compression water connections with 1/2" NPT adapters included

Unique Features:

• �External Digital Display – shows outlet temperature

• �Durable Copper Immersion single heating element, field serviceable

• �Simple Installation – Bottom 1/2" NPT water connections

RTEX-18

Unique Features:

• �External Digital Thermostatic

Control with LED display (+/- 1 degree accuracy)

• �Most advanced self-modulation, adjust power to meet hot water demand

• �Durable Copper Immersion two heating elements, field serviceable

• �Simple Installation – Bottom 3/4" NPT water connections

RTEX-24, RTEX-27

Unique Features:

• �External Digital Thermostatic

Control with LED display (+/- 1 degree accuracy)

• �Most advanced self-modulation, adjust power to meet hot water demand

• �Durable Copper Immersion three heating elements, field serviceable

• �Simple Installation – Bottom 3/4" NPT water connections

Unique Features:

• �External Digital Thermostatic

Control with LED display (+/- 1 degree accuracy)

• �Most advanced self-modulation, adjust power to meet hot water demand

• �Durable Copper Immersion four heating elements, field serviceable

• �Simple Installation – Bottom 3/4" NPT water connections

RTEX-36

MODEL NUMBER

TEMPERATURE RISE °F

0.5

GPM

1.0

GPM

1.5

GPM

2.0

GPM

2.5

GPM

3.0

GPM

4.0

GPM

5.0

GPM

6.0

GPM

SINGLE POINT-OF-USE

RTEX-04 48° 24° 16° 12° – – – – –

RTEX-06 75° 37° 25° 19° – – – – –

MULTIPLE APPLICATIONS

RTEX-08 + 55° 36° 27° 22° 18° 14° – –

RTEX-11 + 75° 50° 38° 30° 25° 19° – –

RTEX-13 + 89° 59° 44° 36° 30° 22° – –

RTEX-18 + + 82° 62° 49° 41° 31° 25° –

RTEX-24 + + 109° 82° 66° 55° 41° 33° 27°

RTEX-27 + + + 92° 74° 62° 46° 37° 31°

RTEX-36 + + + + 98° 82° 62° 49° 41°

+ Temperature electronically limited setting on adjustable thermostat on front cover

*RTEX-04 and RTEX-06 only show output temperature and are non-thermostatically controlled

Rheem.com

Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free compliance.

Standard Hand Sink 0.5 GPM

Washing Machine 1 to 1.5 GPM

�Water-Saver Shower Head 1.5 GPM

Dishwasher 1 to 2 GPM

Kitchen Sink 1 to 2 GPM

Standard Shower Head 2.0 GPM

Bath Tub ≥ 4 GPM

Whole-Home Up to 6 GPM

Warranty

• �5-Year heating chamber and 1-year parts limited warranty See Residential Warranty Certificate for complete information RTEX-08, RTEX-11, RTEX-13

RTEX-18

RTEX-24, RTEX-27 RTEX-36

RTEX-04, RTEX-06

POINT-OF-USE

For 0.5 GPM to 2.0 GPM Applications

MULTIPLE APPLICATIONS

For 0.5 GPM to 6.0 GPM Applications

ADR

Rectangle

ADR

Rectangle

PRINTED IN U.S.A. 12/20 WP FORM NO. TKE-101 Rev. 6

Rheem.com | 800.374.8806 Manufacturers National Service Department

400 Captain Neville Drive, Waterbury, CT 06705

INTEGRATED HOME COMFORTINTEGRATED HOME COMFORT

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Specifications

Water INTEGRATED HOME COMFORT

Residential Electric Professional Classic Tankless Water Heaters

*�240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according to a 240V applied voltage. Check with local officials prior to derating the electrical infrastructure.

DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

MODEL NUMBER

kW

AMPS

RECOMMENDED

BREAKER

SIZE VOLTAGE

RECOMMENDED

WIRE SIZE (CU)

MIN.

FLOW

(GPM)

MAX.

FLOW

(GPM) HEIGHT WIDTH DEPTH

WATER

CONN.

SHIP

WEIGHT

(LBS.)

120V 1 HEATING CHAMBER

RTEX-04 3.5 29A (1x30)A 120 10 AWG 0.3 1.5 5-7/8 10-7/8 2-3/4 1/2 NPT 4.5

240V* 1 HEATING CHAMBER

RTEX-06 6.0 25A (1x25)A 220 10 AWG 0.3 2.0 5-7/8 10-7/8 2-3/4 1/2 NPT 4.5

RTEX-08* 7.3 33A (1x40)A 240 8 AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 7

RTEX-11* 11.8 46A (1x50)A 240 6 AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5

RTEX-13* 13.0 54A (1x60)A 240 6 AWG 0.3 4.8 12-5/8 8-1/4 3-5/8 1/2 CF 8.5

240V* 2 HEATING CHAMBERS

RTEX-18* 18.0 75A (2x40)A 240 8 AWG 0.3 7.0 18-1/4 14-1/2 3-1/2 3/4 NPT 14.78

240V* 3 HEATING CHAMBERS

RTEX-24* 24.0 100A (3x40)A 240 8 AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8

RTEX-27* 27.0 113A (3x40)A 240 8 AWG 0.3 7.0 18-1/4 17-5/8 3-1/2 3/4 NPT 17.8

240V* 4 HEATING CHAMBERS

RTEX-36* 36.0 150A (4x40)A 240 8 AWG 0.3 8.0 18-1/4 21-5/8 3-1/2 3/4 NPT 22.7

Rated Pressure 25 PSI min., 150 PSI max.

Certifications ETL Listed to UL 499 and CSA

Std. Temp. Settings 120°F (Adjustable 80°F-140°F)

Temp. Accuracy +/–1° at steady flow

Turn-On 0.3 GPM

Product Specifications (all models)

RHEEM

PART NUMBER

GPM RATING OF

INSERTS PROVIDED

CONNECTION

SIZE

RTE10001A 1.0, 1.5, 2.0 1/2" NPT

RTE10001B 2.0, 3.0, 4.0, 5.0 3/4" NPT

Optional Inline Flow Regulator

• �Enhanced outlet temperature control

• �Install on the outlet side of the heater

• �Limit maximum volume to the specified flow rate to ensure exiting temperature is within an acceptable range

• �Flow Regulators for ½" and ¾" NPT plumbing connections

• Flow range: 1 to 5 gallons per minute

Suggested Sizing Guide

MODEL

NUMBER

FLOW

REGULATOR

PART NO.

GPM INSERT TO USE BASED ON

INLET WATER TEMPERATURE

40°F 50°F 60°F 70°F

RTEX-04 N/A N/A N/A N/A N/A

RTEX-06 N/A N/A N/A N/A N/A

RTEX-08 RTE10001A 1.0 1.0 1.0 1.5

RTEX-11 RTE10001A 1.0 1.0 1.5 2.0

RTEX-13 RTE10001A 1.0 1.0 1.5 2.0

RTEX-18 RTE10001B 2.0 2.0 2.0 3.0

RTEX-24 RTE10001B 2.0 2.0 3.0 4.0

RTEX-27 RTE10001B 2.0 3.0 4.0 5.0

RTEX-36 RTE10001B 3.0 4.0 5.0 5.0

Suggested Specifications Unit shall have copper clad immersion heating element(s) with brass terminations for increased durability. External temperature control and display adjustable in 1° increments with a range of 80°-140°F.

Display shall be capable of displaying setpoint temperature in Celsius or Fahrenheit temperature scales. Unit shall utilize a flow meter with a 0.3 gpm activation point and manage power based on actual flow rate and inlet temperature. Values should be processed 60 times per second. Unit shall be WQA certified lead free, certified to UL499 and CSA C22.2 No.64.