This is a product specification sheet for the Mitsubishi Electric Trane HVAC TLGHF0300RVX02A energy recovery ventilation (ERV) unit. The document provides comprehensive technical specifications and dimensional details for this commercial HVAC component.

The TLGHF0300RVX02A is a Lossnay® cross-flow energy recovery ventilator with a capacity of 300 CFM (510 m³/h) designed for 208/230V, single-phase, 60 Hz operation. Key specifications include power consumption ranging from 0.111 to 0.235 kW, adjustable fan speeds from 75-300 CFM with corresponding static pressure ratings of 0.06–1.0 inches of water gauge, and temperature exchange efficiency ranging from 83% to 65.5% depending on fan speed. The unit features a high-efficiency EC motor, an 8.75-inch diameter centrifugal fan, and utilizes a cellulose fiber membrane heat exchange core for air-to-air total heat exchange. The external dimensions are 41-7/8 x 41-3/16 x 13-1/32 inches with a net weight of 75 pounds. The unit includes a standard MERV 7 non-woven fabric filter and supports optional MERV 14 and MERV 16 filters. Control options include a stand-alone remote controller (TZ-62DR-EA) with M-NET connectivity and external input bypass damper control capability. Additional accessories available include duct silencers, upgraded filters, signal output terminals, and CO2 sensors (built-in or wall-mounted options).

View the file

Other files

File Type Posted
S30 - SAM - Special Notice - Cancellation - 36C77626R0062_2 - EHRM Infra Upgrades - Togus.pdf PDF
S06 - Amend 0002 - Att 03 - Corrected Agenda - RFP - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0002 - 36C77626R0062 - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 02 - SV - Attendance SHT - 06292026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - 36C77626R0062 - 07142026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - RFIs - 07132026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S06 - Amend 0001 - Att 01 - Rvd Structural Drwg - 06192026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 03 - SV - Agenda - RFP - 06292026 - EHRM Infra - Togus.pdf PDF
S02 - SOW - Att 05 - Drwg - Vol 3 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 13 - Const Sch - 02132026 - EHRM Infra Upgrades - Constr Togus.pdf PDF
S02 - Att 03 -Prj Info Sheet for KTR - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 03 - Drwg - Vol 1C - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 22 - TS-000 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 07 - 852.219-75 - 06172026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - Att 04 - Memo - Brand Name - 04092026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - SOW - Att 35 - Cut Sheet 13 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 17 - Memo - Phy Sec Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 27 - Cut Sheet 05 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 09 - Specs - Vol 3- 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 30 - Cut Sheet 08 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 24 - Cut Sheet 02 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 05 - Division Cost Breakdown - EHRM Infra Upgrade - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 29 - Cut Sheet 07 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 37 - Cut Sheet 15 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 16 - Submittal Reg - 02182026 - EHRM Infra - Upgrades - Constr - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 14 - Design Calcs - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 18 - Memo - Prj Stnd Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 21 - PCRA 3 - MCR and Trench Work - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 40 - Cut Sheet 18 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 33 - Cut Sheet 11 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 01 - Drwg - Vol 1A - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 38 - Cut Sheet 16 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 06 - Drwg - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 11 - Haz Mat Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 12 - Geotechnical Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 32 - Cut Sheet 10 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 08 - Specs - Vol 1 - Div 02-14 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 20 - PCRA 2 - Cabling and Data Outlets - EHRM Infra Upgrades - Constr - Togus.pdf PDF
RFP - EHRM Infra Upgrade - 36C77626R0062 - 06172026 - Togus.pdf PDF
S02 - SOW - Att 19 - PCRA 1 - TR Constr - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 07 - Specs - Vol 1 - Div 00-01 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 15 - Design Narrative - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 23 - Cut Sheet 01 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 31 - Cut Sheet 09 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 02 - PPQ - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 02 - Drwg - Vol 1B - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 34 - Cut Sheet 12 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 01 - SOW - 05112026 - EHRM Infra Upgrades - Togus.pdf PDF
S02 - SOW - Att 10 - Specs - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 36 - Cut Sheet 14 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications are subject to change without notice.� © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:

System Reference: Date:

GENERAL FEATURES

•Lossnay® cross-flow energy recovery core
•Minimal cross contamination between entering and leaving air streams
•Stand-alone remote controller (TZ-62DR-EA)
•M-NET Connectivity
•External input bypass damper control
•Stand alone or interlocks connects with all Mitsubishi Electric products
•Four fan speeds
•High efficiency DC Motor
•Standard MERV 7 non-woven fabric filter, washable fiber
•Optional high-efficiency MERV 14 and MERV 16 filters

Specifications System Unit Type TLGHF0300RVX02A

Capacity CFM [m3/h] 300 [510] Power source Voltage, Phase, Hertz 208/230V, 1-phase, 60 Hz Power Consumption kW 0.111 - 0.235 Current A 0.017 - 0.048 Starting Current A 6.1

MCA A 4.3

Maximum Overcurrent Protection (MOCP) A 15

Fan Air Volume CFM [m3/h] 75-150-225-300 [127-225-382-510] External Static pressure in.WG 0.06–0.25–0.56–1.0

Exchange Efficiency Temperature % 83-76-70-65.5 Enthalpy Cooling % 65.0-58.0- 53.5- 50.0 Enthalpy Heating % 81.5-74.0-66.5-63.0

External Finish Galvanized steel sheet External Dimensions In. [mm] 41-7/8 x 41-3/16 x 13-1/32 [1,063 x 1,046 x 331] Net weight Lbs [kg] 75 [34] Energy Transfer Mechanism Lossnay® Core Heat Exchange Material Partition, spacing plate-cellulose fiber membrane Heat Exchange System Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Blower Type 8-3/4 In. diameter centrifugal fan Motor Type EC Motor Entering Air Temperature Operation Range °F [°C] 14 to 104 [-10 to 40] Sound pressure level dB(A) 18.0–22.0–31.0-37.0

TLGHF0300RVX02A

ENERGY RECOVERY VENTILATION

karis Rectangle karis Rectangle karis Rectangle karis Rectangle karis Rectangle karis Rectangle karis Rectangle karis Rectangle

Specifications are subject to change without notice.� © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

ACCESSORIES: TLGHF0300RVX02A

Wired Remote Controller Lossnay® ERV Remote Controller TZ-62DR-EA Control Interface Signal Output Terminal PZ-4GS-E Duct Accessories Duct Silencer PZ-200SS-E

Filter

MERV 14 Filter PZ-50RFP-E MERV 16 Filter PZ-50RFP2-E MERV 7 Filter (Included) PZ-50RF9-E

Remote Sensor CO2 Sensor, Built-In PZ-70CSB-E CO2 Sensor, Wall Mount PZ-70CSW-E1

Specifications are subject to change without notice.� © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

FORM# TLGHF0300RVX02A - 202304

UNIT SCALE

inch(mm) N.T.S

DIMENSIONS: TLGHF0300RVX02A

Job Name 11:
System Reference 11:
Date 11:
Check Box 8: Off
Check Box 1: Off
Check Box 2: Off
Check Box 3: Off
Check Box 4: Off
Check Box 5: Off
Check Box 6: Off
Check Box 7: Off

File details come from the government source that posted it. Updated .