S02 - SOW - Att 11 - Haz Mat Report - EHRM Infra Upgrades - Constr - Togus.pdf

PDF 5 MB Posted

Attached to
Electronic Health Record Modernization Infrastructure Upgrades - Construction - Togus, ME
Solicitation number
36C77626R0062
Issued by

About this file

This is a Limited Asbestos and Lead Inspection Report prepared by American Engineering Testing, Inc. (AET) for the Togus VA Medical Center in Augusta, Maine, dated August 15, 2023, in support of Electronic Health Record Modernization (EHRM) Infrastructure Upgrades construction activities.

AET conducted a limited inspection on June 20-22, 2023, by a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector. The inspection covered select IT equipment rooms in 27 buildings at the facility and included collection of 75 samples of suspect asbestos-containing building materials (ACBM) and testing of 77 suspect painted/coated surfaces. All 75 asbestos samples tested negative for asbestos content. However, three lead-containing paint areas were identified in Building 69, Floor 01, Room 102: white plaster walls and ceilings containing 17.6 mg/cm² lead (228 SF), light blue plaster walls containing 1.30 mg/cm² lead (64 SF), and a white wood door frame containing 36.30 mg/cm² lead (18 SF). The report recommends that lead-containing materials be removed by a State of Maine Department of Environmental Protection licensed lead abatement company or an EPA Lead Renovation, Repair and Painting (RRP) trained and certified company. Contractors must obtain required permits, submit State of Maine Department of Environmental Protection Notification Forms prior to demolition/renovation activities, and prepare an environmental contingency management plan. The report should be used in conjunction with a prior asbestos/lead report dated March 25, 2011, prepared by Mabbett & Associates, Inc., as the current inspection only addressed materials not previously identified.

View the file

Other files

File Type Posted
S30 - SAM - Special Notice - Cancellation - 36C77626R0062_2 - EHRM Infra Upgrades - Togus.pdf PDF
S06 - Amend 0002 - Att 03 - Corrected Agenda - RFP - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0002 - 36C77626R0062 - 07202026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 02 - SV - Attendance SHT - 06292026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - 36C77626R0062 - 07142026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - RFIs - 07132026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S06 - Amend 0001 - Att 01 - Rvd Structural Drwg - 06192026 - EHRM Infra - Togus.pdf PDF
S06 - Amend 0001 - Att 03 - SV - Agenda - RFP - 06292026 - EHRM Infra - Togus.pdf PDF
S02 - SOW - Att 05 - Drwg - Vol 3 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 13 - Const Sch - 02132026 - EHRM Infra Upgrades - Constr Togus.pdf PDF
S02 - SOW - Att 26 - Cut Sheet 04 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 03 -Prj Info Sheet for KTR - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 03 - Drwg - Vol 1C - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 22 - TS-000 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 07 - 852.219-75 - 06172026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - Att 04 - Memo - Brand Name - 04092026 - EHRM Infra Upgrade - Togus.pdf PDF
S02 - SOW - Att 35 - Cut Sheet 13 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 17 - Memo - Phy Sec Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 27 - Cut Sheet 05 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 09 - Specs - Vol 3- 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 30 - Cut Sheet 08 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 24 - Cut Sheet 02 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 05 - Division Cost Breakdown - EHRM Infra Upgrade - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 29 - Cut Sheet 07 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 37 - Cut Sheet 15 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 16 - Submittal Reg - 02182026 - EHRM Infra - Upgrades - Constr - Togus.xlsx XLSX spreadsheet
S02 - SOW - Att 14 - Design Calcs - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 18 - Memo - Prj Stnd Compliance - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 21 - PCRA 3 - MCR and Trench Work - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 40 - Cut Sheet 18 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 33 - Cut Sheet 11 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 01 - Drwg - Vol 1A - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 38 - Cut Sheet 16 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 06 - Drwg - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 12 - Geotechnical Report - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 32 - Cut Sheet 10 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 08 - Specs - Vol 1 - Div 02-14 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 20 - PCRA 2 - Cabling and Data Outlets - EHRM Infra Upgrades - Constr - Togus.pdf PDF
RFP - EHRM Infra Upgrade - 36C77626R0062 - 06172026 - Togus.pdf PDF
S02 - SOW - Att 19 - PCRA 1 - TR Constr - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 07 - Specs - Vol 1 - Div 00-01 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 15 - Design Narrative - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 23 - Cut Sheet 01 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 31 - Cut Sheet 09 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 02 - PPQ - EHRM Infra Upgrade - Togus.docx DOCX document
S02 - SOW - Att 02 - Drwg - Vol 1B - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 34 - Cut Sheet 12 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - Att 01 - SOW - 05112026 - EHRM Infra Upgrades - Togus.pdf PDF
S02 - SOW - Att 10 - Specs - Vol 4 - 02182026 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
S02 - SOW - Att 36 - Cut Sheet 14 - EHRM Infra Upgrades - Constr - Togus.pdf PDF
Show 40 more

Latest 50 of 57 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

American Engineering Testing 550 Cleveland Avenue North St. Paul, MN 55114-1804 teamAET.com • 800.972.6364

Geotechnical ● Materials Forensic ● Environmental

Building Technology Petrography/Chemistry

LIMITED ASBESTOS

AND LEAD INSPECTION REPORT

Togus VA Medical Center 1 VA Center Augusta, ME 04330

AET Project No. P-0019594

Report Date:

August 15, 2023

Prepared for:

GDM

1401 W. 34th Ave., Ste. 200 Anchorage, AK 99503

550 Cleveland Avenue North | Saint Paul, MN 55114 Phone (651) 659-9001 | (800) 972-6364 | Fax (651) 659-1379 | teamAET.com | AA/EEO

This document shall not be reproduced, except in full, without written approval from American Engineering Testing, Inc.

GDM

1401 W. 34th Ave., Ste. 200 Anchorage, AK 99503

Attn: Mr. Conrad Chandler, Project Manager

RE: Limited Asbestos and Lead Inspection Report

Togus VA Medical Center 1 VA Center Augusta, ME 04330

Dear Mr. Chandler:

American Engineering Testing, Inc. has completed the enclosed report of Limited Asbestos and Lead Inspection services for the Togus VA Medical Center located in Augusta, Maine. This service was performed in accordance with our proposal agreement no. P-0019594.

We appreciate the opportunity to have been of service to you on this project. If you have any questions regarding the information presented in this Limited Asbestos and Lead Inspection Report or if we can be of additional assistance, please contact me.

Sincerely, American Engineering Testing, Inc.

Bruce A. Boehm Carlson Sr. Environmental Project Manager E-mail: bboehmcarlson@teamAET.com Phone: (651) 999-1387

Enclosure

Limited Asbestos and Lead Inspection Report Togus VA Medical Center, Augusta, ME

Page ii

TABLE OF CONTENTS

Page

TRANSMITTAL LETTER………………………………………………………………………………i TABLE OF CONTENTS........................................................................................................... ii EXECUTIVE SUMMARY .........................................................................................................iii

1.0 INTRODUCTION

1.1 Purpose

1.2 Scope of Inspection

1.3 Limitations

2.0 ASBESTOS AND LEAD INSPECTION PROCEDURES

2.1 General Information

2.2 Function of Inspection

3.0 ASBESTOS AND LEAD INSPECTION RESULTS

3.1 Asbestos-Containing Materials

3.2 Lead Paints/Coatings

4.0 RECOMMENDATIONS

5.0 GENERAL REMARKS

5.1 Standard of Care

5.2 Certifications

TABLES

1. Summary of Non-Asbestos-Containing Building Materials

2. Summary of Lead Containing Paints/Coatings

3. Summary of Non-Lead Containing Paints/Coatings

FIGURES

1. General Notes

2. Building 200 Ground Level Asbestos Containing Building Materials Sample and Lead Paint Test Locations

3. Building 200 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

4. Building 200 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

5. Building 200 Level 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

6. Building 200 Level 5 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

7. Building 204 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

8. Building 205 Levels 1 and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

9. Building 206 Levels 1, 2, and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

10. Building 207 Levels 1, 2, and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

11. Building 208 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

12. Building 210 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

13. Building 211 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

14. Building 212 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

15. Building 221 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

16. Building 232 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

Page iii

17. Building 255 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

18. Building 300 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

19. Building 69 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations

APPENDICES

A. Explanation of Tables

B. INTENTIONALLY BLANK

C. Asbestos Laboratory Analytical Results D. Lead Testing Results E. Pre-Demolition Environmental Checklist and Guide F. Photographic Log G. Laboratory Credentials H. AET Certifications

Page iv

EXECUTIVE SUMMARY

American Engineering Testing, Inc. (AET) was authorized by GDM (Client) to conduct a limited asbestos and lead inspection of various buildings located at the Togus VA Medical Center, 1 VA Center, Augusta, Maine (Site). The purpose for the limited asbestos and lead inspection was to identify, sample and quantify suspect asbestos-containing building materials (ACBMs) and to test and quantify lead containing paints/coatings as required by the State of Maine Department of Environmental Protection. Services performed by AET were conducted in accordance with our Proposal No. P- 0019594.

Bruce Boehm Carlson, a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector, completed the inspection on June 20-22, 2023. AET collected 75 samples of suspect ACBM and tested 77 suspect painted/coated lead surfaces at the Site.

The inspection was limited to select IT equipment rooms in the following buildings:

• 1, 3, 4, 27, 32, 69, 200, 201, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 221, 232, 235, 238, 239, 240, 248, 255 and 300.

AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.

Please review the prior report for information related to the materials that were not sampled or tested by

AET.

The materials that were sampled and tested by AET were found to not contain asbestos.

The following painted/coated surfaces that were tested by AET were found to contain greater than 1 milligram per square centimeter (mg/cm2) lead:

• Shot 54 - Photo 2 – Building 69, white plaster walls and ceilings were found to contain 17.6 mg/cm2 lead. Approximately 228 total square feet (SF) was identified in Fl. 01 Rms. 102 and 102 NE Closet.

• Shot 55 - Photo 2 – Building 69, light blue plaster walls were found to contain 1.30 mg/cm2 lead.

Approximately 64 total square feet (SF) was identified in Fl. 01 Rm. 102.

• Shot 56 - Photo 2 – Building 69, white wood door frame was found to contain 36.30 mg/cm2 lead. Approximately 18 total square feet (SF) was identified in Fl. 01 Rm. 102.

Page v

The lead containing materials must be removed and properly disposed of by a State of Maine Department of Environmental Protection licensed lead abatement company utilizing trained and certified supervisors and workers OR a Lead Renovation, Repair and Painting (RRP) trained and certified company utilizing trained personnel.

Salvage, reuse, recycle or properly dispose of the numerous regulated waste materials identified at the Site prior to commencing with renovation activities.

Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition/renovation activities.

If untested suspect asbestos-containing materials or potential lead containing paints/coatings are identified during renovation, do not disturb the materials and contact AET for consultation or follow-up testing. Notify the general contractor of the location and quantity of asbestos and regulated waste items at the Site.

1.0 INTRODUCTION

1.1 Purpose

This report presents the results of the limited asbestos and lead Inspection performed at the Togus VA Medical Center, 1 VA Center, Augusta, Maine (Site). American Engineering Testing, Inc. (AET) completed the inspection at the request of GDM (Client). The inspection was performed to facilitate moving and installation of IT cabling and equipment in certain buildings at the Site.

The purpose for the limited asbestos and lead inspection was to identify, sample and quantify suspect asbestos-containing building materials (ACBMs) and to test and quantify lead containing paints/coatings as required by the State of Maine Department of Environmental Protection.

1.2 Scope of Inspection

AET’s scope of services included the following tasks:

• Conduct a visual inspection for the presence of ACBM.

• Collect representative bulk samples of suspect ACBMs for analysis.

• Submit the bulk samples of suspect materials to an accredited National Voluntary Laboratory Accreditation Program (NVLAP) laboratory for analysis of asbestos content. Laboratory certifications can be found in Appendix G.

• Identify, test, and quantify the various painted/coated materials for lead content utilizing a portable x-ray fluorescence (XRF) analyzer.

• Prepare a final report summarizing the results of the assessment.

1.3 Limitations

The inspection was limited to select IT equipment rooms the following buildings:

• 1, 3, 4, 27, 32, 69, 200, 201, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 221, 232, 235, 238, 239, 240, 248, 255 and 300.

Additionally, AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.

Please review the prior report for information related to the materials that were not sampled or tested by

AET.

2.0 ASBESTOS AND LEAD INSPECTION PROCEDURES

2.1 General Information

The Inspection was conducted on June 20-22, 2023 by Bruce Boehm Carlson, a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector. AET collected 75 samples of suspect asbestos-containing building materials (ACBM) and tested 77 suspect painted/coated lead surfaces at the Site.

Suspect asbestos inspection, sampling and analytical procedures were performed in accordance with EPA Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763, Subpart E; EPA National Emission Standard for Hazardous Air Pollutants (NESHAP), 40 CFR Part 61; and the Occupational Safety and Health Administration (OSHA) rules and regulations, Asbestos Standards for General Industry 29 CFR 1910.1001 and Asbestos Standards for the Construction Industry 29 CFR 1926.1101.

Asbestos samples were analyzed utilizing polarized light microscopy (PLM) by Eurofins CEI, a NVLAP accredited laboratory (NVLAP Lab No. 101768-0). Other potential regulated wastes were inventoried according to the Pre-Demolition Environmental Checklist and Guide.

Potential lead-containing paint sampling and analytical procedures were performed in accordance with the State of Maine Department of Environmental Protection, U.S. Department of Housing and Urban Development (HUD), the EPA and the OSHA. Testing was conducted utilizing a Niton portable XRF analyzer.

2.2 Function of Inspection

The EPA NESHAP requires building owners to inspect for ACBM in areas of a building where renovation or demolition will take place. Some States regulate the removal and disposal of regulated waste as outlined in the Pre-Demolition Environmental Checklist and Guide.

All manufactured and some natural products are considered suspect ACBM. Materials that are considered to be non-suspect are wood, metal, glass, and fiberglass. Prior to renovation or demolition of a building, all regulated friable ACBM must be removed from the affected area. In addition, non-friable materials, which are in a damaged condition or are likely to become friable during the process of renovation or demolition also require removal. Non-friable materials, which are in good condition at the time of inspection and most likely will not become friable during demolition may, under certain circumstances, remain in place prior to demolition. EPA and OSHA define any building material which contains greater than one percent asbestos to be asbestos-containing material. It is also required to point-count by PLM the percent asbestos in friable asbestos-containing material (ACM) estimated to contain less than one percent asbestos.

The State of Maine Department of Environmental Protection regulates the removal and disposal of regulated waste. This also includes delaminating lead-based paint.

HUD and the EPA identify lead-based paint as any paint, varnish, shellac, or other coating that contains lead concentrations equal or greater than one milligram per square centimeter (1.0 mg/cm2), 0.5 % by weight or 5,000 parts per million (ppm). OSHA recognizes lead-based paint as paint that contains any detectable amount of lead. Although the use of lead in paint was banned in 1978 by the Consumer Product Safety Commission (CPSC), consumer paints can still contain up to 0.06 % lead by weight or 600 ppm. Lead-based paints are still commonly used in many commercial applications.

3.0 ASBESTOS AND LEAD INSPECTION RESULTS

3.1 Asbestos-Containing Materials

See Figures 1 through 19 for the locations of the asbestos containing building material samples. See Table 1 for the materials that do not contain asbestos. The asbestos analytical laboratory report is included in Appendix C. Photographs are included in Appendix F. Laboratory credentials are included in Appendix G.

AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.

Please review the prior report for information related to the materials that were not sampled or tested by

AET.

The materials that were sampled and tested by AET were found to not contain asbestos.

Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition activities.

3.2 Lead Paints/Coatings

See Figures 1 through 19 for the locations of the lead testing locations. AET tested various paints/coatings in various IT equipment rooms at the Site. A summary of the lead containing paints/coatings can be found in Table 2 and a summary of the non-lead containing paints/coatings can be found in Table 3. Please see Appendix D for the locations and results of all the tested paints/coatings. A copy of the XRF Performance Characteristics Sheets can be found in Appendix G.

AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.

Please review the prior report for information related to the materials that were not sampled or tested by

AET.

The following painted/coated surfaces that were tested by AET were found to contain greater than 1 milligram per square centimeter (mg/cm2) lead:

• Shot 54 - Photo 2 – Building 69, white plaster walls and ceilings were found to contain 17.6 mg/cm2 lead. Approximately 228 total square feet (SF) was identified in Fl. 01 Rms. 102 and 102 NE Closet.

• Shot 55 - Photo 2 – Building 69, light blue plaster walls were found to contain 1.30 mg/cm2 lead.

Approximately 64 total square feet (SF) was identified in Fl. 01 Rm. 102.

• Shot 56 - Photo 2 – Building 69, white wood door frame was found to contain 36.30 mg/cm2 lead. Approximately 18 total square feet (SF) was identified in Fl. 01 Rm. 102.

The lead containing materials must be removed and properly disposed of by a State of Maine Department of Environmental Protection licensed lead abatement company utilizing trained and certified supervisors and workers OR a Lead Renovation, Repair and Painting (RRP) trained and certified company utilizing trained personnel.

Salvage, reuse, recycle or properly dispose of the numerous regulated waste materials identified at the Site prior to commencing demolition activities. A copy of the Pre-Demolition Environmental Checklist and Guide is in Appendix E.

4.0 RECOMMENDATIONS

Based on the results of this investigation, AET recommends the following:

• The facility owners must notify employees, tenants, contractors, and vendors working in the building of the presence, quantity, and location of identified or assumed ACBM and lead containing paints/coatings.

• Prior to commencing renovation/demolition activities conduct the following:

o Utilize a licensed asbestos abatement company with certified supervisors and workers to remove the ACBM identified in the prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc.

o Utilize a State of Maine Department of Environmental Protection certified lead abatement company utilizing certified supervisors and workers OR an EPA Lead RRP trained and certified contractor to manage the painted/coated surfaces throughout and on the building in accordance with the EPA Lead RRP Rules.

• Salvage, reuse, recycle or properly dispose of the numerous regulated objects identified at the Site prior to commencing renovation activities.

• Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition activities.

• Obtain all required local permits.

• Prepare a general environmental contingency management plan for addressing potential situations that may arise during the renovation project. Example contingencies might include management of petroleum, management of spilled fluids or other unknown regulated items encountered during the demolition and Site excavation.

• During the renovation/demolition activities, if additional suspect asbestos containing materials or potential lead containing paints/coatings are discovered, do not disturb the materials and contact AET for consultation or follow-up testing.

5.0 GENERAL REMARKS

5.1 Standard of Care

Bulk asbestos and lead testing, collection and analysis was conducted in accordance with the State of Maine Department of Environmental Protection required methodology. Other potential regulated wastes were inventoried.

This report summarizes the results of the inspection completed by AET. This inspection and review of the subject property has been limited in scope in that it was undertaken with the knowledge that visual observations and random sampling methods alone might not reveal the presence, full nature, and extent of all ACBM, lead paint, and other regulated wastes in the building. AET makes no representations as to the asbestos or lead content of materials not sampled or that were not accessible to our inspector(s) (i.e., between walls, beneath floors, in sealed pipe chases, etc).

The ACBM, lead paint, and other regulated wastes sample locations and building dimensions were visually estimated. Therefore, the sample locations, building dimensions and approximate square footages of ACBM and lead paint should be considered accurate only to the degree implied by the methods used.

This asbestos and regulated wastes inspection is not intended to be the sole basis for asbestos, lead paint, and regulated waste removal bids. Confirmation of the presence, condition, and quantity of the ACBM’s, lead paints, and other regulated waste should be conducted by prospective removal contractors prior to accepting removal bids. This report is provided for the exclusive use of the client noted on the cover page and is subject to the terms and conditions in the applicable contract between the Client and AET. The Client is the only party to whom AET has explained the limitations of this inspection and has been involved in the shaping of the scope of services. Any third-party review of this report will be subject to the terms and conditions governing contractual work between the Client and

AET. The unauthorized use of, reliance on, or release of information contained in this report, without the expressed written consent of the Client is strictly prohibited and will be without risk or liability.

The services performed by AET on this project have been conducted with a level of care and skill that meets or exceeds industry standards set by reputable members of the profession, practicing in the same locality under similar budget and time constraints. This inspection does not guarantee all ACBM, lead paint, or other regulated waste were found.

5.2 Certifications

I, the undersigned, do hereby certify that I am an accredited Asbestos Building Inspector and Lead Inspector in the State of Maine, certified by the State of Maine Department of Environmental Protection, Nos. AI-0923 and LI-0502. A photocopy of my current asbestos inspector and lead inspector certification are included in Appendix H.

Report Authored By:

Bruce A. Boehm Carlson Eric C. Hesse, PE Senior Environmental Project Manager Environmental Division Manage

Tables

Table 1 - Summary of Non-Asbestos Containing Building Materials

Area Location Room Number

Material ID Subcat ID

Material ID Description Subcategory Description

Material Code

Asbestos Content

Quantity Physical Assessment:

Friability Condition

Damage Potential:

Water Air Vib Acc

Cond Rating

AHERA

Rating

Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson

Building Number:1 VA Ctr.

Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.

Sample Set Name:1 Building Address 2:

City, State Zip:Augusta, ME 04330

Lead Paint

Bldg. 200

Floor 02

302 2x2 Ceiling Tile

PHBW Pinhole Birdwing

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 200

Floor 02

308 Base Cove & Mastic

4BR 4" Brown

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 200

Floor 02

313 Sheet Floor & Mastic

BRBP Brown Board Pattern

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 200

Floor 02

E201

308 Base Cove & Mastic

4M 4" Maroon

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 200

Floor 02

E201

310 12x12 Floor Tile & Mastic

LGGS Light Gray w/ Gray Streaks

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Page 1 of 5Monday, August 14, 2023

10:06:33 PM

American Engineering Testing, Inc.

St. Paul, MN 55114

Location Room Number

Material ID Subcat ID

Material ID Description Subcategory Description

Material Code

Asbestos Content

Quantity Physical Assessment:

Friability Condition

Damage Potential:

Water Air Vib Acc

Cond Rating

AHERA

Rating

Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson

Building Number:1 VA Ctr.

Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.

Sample Set Name:1 Building Address 2:

City, State Zip:Augusta, ME 04330

Lead Paint

Bldg. 200

Floor 05

315 Ceramic Tile

1GW Green & White

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 200

Floor 05

C501

315 Ceramic Tile

4G 4" Gray

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 200E

Floor 01

122E

302 2x2 Ceiling Tile

SM Smooth

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 204

Floor 02

315 Ceramic Tile

4W 4" White

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 206

Floor 02

303 2x4 Ceiling Tile

PHBW Pinhole Birdwing

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 206

Floor 02

310 12x12 Floor Tile & Mastic

LGM Light Gray Mottled

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Page 2 of 5Monday, August 14, 2023

10:06:33 PM

American Engineering Testing, Inc.

Room Number

Material ID Subcat ID

Material ID Description Subcategory Description

Material Code

Asbestos Content

Quantity Physical Assessment:

Friability Condition

Damage Potential:

Water Air Vib Acc

Cond Rating

AHERA

Rating

Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson

Building Number:1 VA Ctr.

Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.

Sample Set Name:1 Building Address 2:

City, State Zip:Augusta, ME 04330

Lead Paint

Bldg. 208

Floor 01

308 Base Cove & Mastic

4G 4" Gray

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 208

Floor 01

310 12x12 Floor Tile & Mastic

LTGM Light Gray Mottled

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 208

Floor 01

310 12x12 Floor Tile & Mastic

LBRM Light Brown Mottled

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 210

Floor 01

303 2x4 Ceiling Tile

PHF Pinhole Fissure

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 255

Floor 01

302 2x2 Ceiling Tile

PHC Pinhole Crater

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 255

Floor 01

310 12x12 Floor Tile & Mastic

LTGGS Light Gray w/ Gray Streaks

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Page 3 of 5Monday, August 14, 2023

10:06:34 PM

American Engineering Testing, Inc.

Room Number

Material ID Subcat ID

Material ID Description Subcategory Description

Material Code

Asbestos Content

Quantity Physical Assessment:

Friability Condition

Damage Potential:

Water Air Vib Acc

Cond Rating

AHERA

Rating

Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson

Building Number:1 VA Ctr.

Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.

Sample Set Name:1 Building Address 2:

City, State Zip:Augusta, ME 04330

Lead Paint

Bldg. 255

Floor 01

321 Caulk

BR Brown

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 255

Floor 01

305 Sheetrock & Taping Compound

WC Walls and Ceilings

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Bldg. 255

Floor 01

308 Base Cove & Mastic

4T 4" Tan

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 255

Floor 01

310 12x12 Floor Tile & Mastic

BGM Beige Marbled

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 255

Floor 01

321 Caulk

R Red

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 300

Floor 01

305 Sheetrock & Taping Compound

WLC Walls and Ceilings

M ND 7 4

Notes: Located in various areas throughout the building.

NFriable

Page 4 of 5Monday, August 14, 2023

10:06:34 PM

American Engineering Testing, Inc.

Room Number

Material ID Subcat ID

Material ID Description Subcategory Description

Material Code

Asbestos Content

Quantity Physical Assessment:

Friability Condition

Damage Potential:

Water Air Vib Acc

Cond Rating

AHERA

Rating

Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson

Building Number:1 VA Ctr.

Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.

Sample Set Name:1 Building Address 2:

City, State Zip:Augusta, ME 04330

Lead Paint

Bldg. 300

Floor 01

308 Base Cove & Mastic

4LG 4" Light Gray

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Bldg. 300

Floor 01

310 12x12 Floor Tile & Mastic

DBRM Dark Brown Marbled

M ND 0 NA

Notes: Located in various areas throughout the building.

NNon-Friable

Page 5 of 5Monday, August 14, 2023

10:06:34 PM

American Engineering Testing, Inc.

Table 2

Togus VA Medical Center Augusta, ME

AET Project No. P-0019594

Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result

54 69 1 102 NE Closet North Wall Plaster White 17.60 228 SF Positive 55 69 1 102 North Wall Plaster Lt. Blue 1.30 64 SF Positive 56 69 1 102 West Door Frame Wood White 36.30 18 SF Positive

Please note that this report is to be used in conjunction with the prior report titled General Asbestos/Lead Containing Paint Summary Report dated March 25, 2011 prepared by Mabbett & Associates, Inc. AET did not test all painted surfaces. Many surfaces appeared to be the same paints identified in the prior report and this report only reflects the materials tested by AET.

Summary of Lead Containing Paints/Coatings

Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: March 20-21, 2023

Table 3

Augusta, ME

AET Project No. P-0011150

Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result

1 Calibration Range <0.01 SRM 2570 0.00 NA Pass 2 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 3 Calibration 3.58 ± 0.39 SRM 2571 3.40 NA Pass 4 221 1 100B East Wall Sheetrock Tan 0.00 NA Negative 5 221 1 100B South Door Frame Metal Tan 0.00 NA Negative 6 221 1 100B South Door Wood Blonde 0.00 NA Negative 7 221 1 100B North Panel Wood Black 0.00 NA Negative 8 221 1 100B South Door Frame Metal Lt. Yellow 0.00 NA Negative 9 221 1 100B South Door Frame Metal Lt. Blue 0.00 NA Negative

10 207 1 132A West Wall Sheetrock Green 0.00 NA Negative 11 207 1 132A North Wall Sheetrock Blue 0.00 NA Negative 12 207 2 201 East Wall Sheetrock Cream 0.00 NA Negative 13 207 3 145/301 East Wall Sheetrock Tan 0.00 NA Negative 14 207 3 145/301 South Panel Wood Black 0.00 NA Negative 15 207 3 307 South Window Frame Metal Gray 0.00 NA Negative 16 207 3 307 West Wall Sheetrock Gray 0.00 NA Negative 17 232 2 202 West Door Wood Blonde 0.00 NA Negative 18 232 2 202 West Door Frame Metal Beige 0.00 NA Negative 19 232 2 202 South Wall Sheetrock Beige 0.00 NA Negative 20 232 2 202 Floor Floor Wood Gray 0.00 NA Negative 21 206 1 145A North Door Frame Metal Gray 0.00 NA Negative 22 206 1 145A West Wall Sheetrock Tan 0.00 NA Negative 23 206 1 145A South Wall Sheetrock Lt. Blue 0.00 NA Negative 24 206 2 213 East Wall Sheetrock Tan 0.60 NA Negative 25 206 2 215 East Wall Sheetrock Lt. Tan 0.00 NA Negative 26 206 3 320 East Wall Sheetrock Tan 0.00 NA Negative 27 206 3 366 North Wall Sheetrock Cream 0.00 NA Negative 28 208 1 117 North Wall Sheetrock Tan 0.00 NA Negative 29 205 1 108 South Wall Sheetrock Tan 0.60 NA Negative 30 205 1 108 East Wall Sheetrock Lt. Green 0.60 NA Negative 31 205 3 307E East Wall Sheetrock Tan 0.00 NA Negative 32 205 3 307E South Wall Sheetrock Lt. Blue 0.00 NA Negative 33 Calibration Range <0.01 SRM 2570 0.00 NA Pass 34 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 35 Calibration 3.58 ± 0.39 SRM 2571 3.50 NA Pass 36 200 G C009 South Wall Sheetrock Yellow 0.00 NA Negative 37 200 G C009 West Wall Concrete Yellow 0.00 NA Negative

Summary of Non-Lead Containing Paints/Coatings

Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: June 20-21, 2023

Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result

Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: June 20-21, 2023

38 200 G C009 South Door Frame Metal Lt. Yellow 0.00 NA Negative 39 200 G C009 South Door Frame Metal Gray 0.00 NA Negative 40 200 G C009 South Door Wood Blonde 0.00 NA Negative 41 200 G 28 South Wall Sheetrock Cream 0.00 NA Negative 42 200 3 E341 West Wall Sheetrock Tan 0.00 NA Negative 43 200 3 E341 East Wall Sheetrock Lt. Blue 0.00 NA Negative 44 200 5 560 Floor Floor Ceramic Tile 1" Green/White 0.00 NA Negative 45 200 5 C501 South Wall Ceramic Tile 4" Gray 0.00 NA Negative 46 200 5 C501 South Wall Ceramic Tile 4" White 0.00 NA Negative 47 Calibration Range <0.01 SRM 2570 0.00 NA Pass 48 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 49 Calibration 3.58 ± 0.39 SRM 2571 4.00 NA Pass 50 Calibration Range <0.01 SRM 2570 0.00 NA Pass 51 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 52 Calibration 3.58 ± 0.39 SRM 2571 3.60 NA Pass 53 69 1 Linen Closet West Panel Wood White 0.00 NA Negative 57 69 1 102 West Door Wood Blonde 0.01 NA Negative 58 211 1 101 East Panel Wood White 0.00 NA Negative 59 211 1 101 West Door Frame Metal Lt. Gray 0.00 NA Negative 60 211 1 101 West Door Wood Blonde 0.00 NA Negative 61 211 1 101 North Wall Brick White 0.02 NA Negative 62 212 1 100 South Wall Concrete Gray 0.00 NA Negative 63 212 1 100 Floor Floor Concrete White 0.05 NA Negative 64 Calibration Range <0.01 SRM 2570 0.00 NA Pass 65 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 66 Calibration 3.58 ± 0.39 SRM 2571 3.60 NA Pass 67 204 2 200 North Wall Plaster Tan 0.00 NA Negative 68 204 2 200 North Wall Ceramic Tile 4" White 0.13 NA Negative 69 Calibration Range <0.01 SRM 2570 0.00 NA Pass 70 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 71 Calibration 3.58 ± 0.39 SRM 2571 3.30 NA Pass 72 255 1 106 West Door Wood Blonde 0.00 NA Negative 73 255 1 106 West Door Frame Metal Brown 0.00 NA Negative 74 255 1 106 South Wall Sheetrock Tan 0.00 NA Negative 75 Calibration Range <0.01 SRM 2570 0.00 NA Pass 76 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 77 Calibration 3.58 ± 0.39 SRM 2571 3.20 NA Pass

Please note that this report is to be used in conjunction with the prior report titled General Asbestos/Lead Containing Paint Summary Report dated March 25, 2011 prepared by Mabbett & Associates, Inc. AET did not test all painted surfaces. Many surfaces appeared to be the same paints identified in the prior report and this report only reflects the materials tested by AET.

Figures

CRAWL SPACE

BIO-MED

BIO-MED SHOP

TOILET

CHIEF

35 OFFICE

33 CORRIDOR

STAIR

BIO-MED

SPACE

31A

CONF RM

BIO-MED

COMM

ELEV 3

EMS STOR

WHEELCHAIR

REPAIR SHOP

UNIVERSAL

HAZARDOUS

WASTE STOR

149J

CORRIDOR

MECH

MEN LOCKER

149I

MECH

ELEV 2

ELEV 1

WATER PUMP

WOMEN LOCKER

STOR

EMS OFFICE

ROOM

C8A

CORRIDOR

C72

SERVICE LOBBY

C8

PROVIDER OFFICE

C25

CG

STAIR

PROVIDER OFFICE

C23

CG

UP

13-02

CABLING IN CORRIDORS

CORRIDOR

C71

ROOM

C3 ELEV LOBBY

C70

CG

COMM

C6

MEN

C1

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

STAIR

E80

ROOM

E79

ROOM

E19A

ROOM

E17 ROOM

E13E

CORRIDOR

E74

ROOM

E13F

ROOM

E13G

ELEC

E15

ROOM

E11

TR #7B

E13I

OFFICE

E13H

CONF / BREAK RM

E20 OFFICE

E22

ROOM

E13D

ROOM

AGENT CASHIER

E24

ROOM

ROOM

PHARMACY

E19

ROOM

E13C

ROOM

E13

ROOM

E13B

ROOM

E19B

ROOM

E4A

ROOM

E6

ROOM

E4

ROOM

E4B

CORRIDOR

E71

VEST

E70A

PHARMACY

E002A

ROOM

E13A

ROOM

E09

CORRIDOR

E70

ROOM

E12

ROOM

E8

ROOM

E8A

ROOM

E10H

ROOM

E10B

ROOM

E10F

ROOM

E10G

ROOM

E41 ROOM

E52

ROOM

E54

ROOM

391E72

EXAM

E56

EXAM

E55

ROOM

E10

ROOM

E10A

ROOM

E10I

ROOM

E10D

ROOM

13-03

TR CONSTRUCTION200-AE-300

ROOM

E16

ROOM

E14

WOMEN

C4

OFFICE

C17

OFFICE

E23A

OFFICE/EXAM

E23

HAC

C2

OFF PHYS TX

E21

FLOW RM

C13

CG

OFFICE

C15

OFFICE

C14

PHARMACY

C35

EXAM

C34

EXAM

C49

ELEV

ELEV

ELEV

STAFF TOILET

C19

PROVIDER OFFICE

C21

CG

CG

CORRIDOR

CORRIDOR

MAIL RM

ELECTRONICS

TECH

MAIL RM

4A

HAC

C24

PROVIDER OFFICE

C22

CG

CG

PROVIDER OFFICE

C20

DR OFFICE

C37

DR OFFICE

C39

HAC STOR

EMS STOR

LAB STOR

IT STOR

ELEV LOBBY

FMS

STARBUCKS

1 PROSTHETIC STOR

HAC

STAIR

76 TR #7A

C009A

ELECTRONIC

STOR

C009

CORRIDOR

PROSTHETIC STOR

3A

TR CONSTRUCTION

13-03

200-AE-300

CORRIDOR

200209

LOGISTICS

STOR

16C

TOILET

149E

NURSING SUPPLY

C40 TELEHEALTH

C38

ROOM

C55A

ED DIRECTOR

C55

VENDING ACCESS

16F

VENDING

BIO-MED SHOP

16B

SMOKING AREA

16E

EMERGENCY

ELECTRICAL RM

C54A

EXAM

C53

EXAM

C36

ED NURSE

MANAGER

C56

ROOM

C54

EXAM

C51

CG

CORRIDOR

C74

CORRIDOR

149F

CORRIDOR

C76

EXAM

C50

EXAM

C48

OFFICE/EXAM

C12

CG

TOILET

E27A

OFFICE

E25

OFFICE

C11

OFFICE/EXAM

C10

CORRIDOR

E76

IPC TEAM

E28

ELEC

E26

ROOM

E31

ROOM

E34

ROOM

E36

ROOM

E10J

ROOM

E1

ROOM

E33

ROOM

E44

TOILET

E46

TOILET

E48

ROOM

E50A

ROOM

E50

ROOM

E39

CORRIDOR

E77

BIOPSY ROOM

C31 OFFICE

C30

ROOM

C30A

EXAM

LOCKER

E27

STOR

CO45A

ROOM

E42

AMBULANCE BAY

E43

UP

STAIR

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

STAFF ON-CALL

C46A

STOR

C46B

ROOM

E78 ROOM

E45

LIFE SUPPORT RM

E47

EXAM

E49

ROOM

E53

MEDS

E51

TOILET

TREATMENT

E53A

DERMATOLOGY

C33

DERM EXAM

C32

EXAM

C45

STAFF

C46

ROOM

C46B1

OFFICE

C52

ELEC

57A

C G

C G C

G

C G

C G

36, 38, 39, 40

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 200/200E - Ground Level

Figure 2

APPROXIMATE SCALE IN FEET

200 40

N

File: Togus_Bldg200_200E.dwg Ground PO 17938-1911

Legend

Asbestos Sample Location

Positive Material

###-XXX-X

## Lead Test Location

CRAWL SPACE

STAIR

COMP GAS

S 174TOR

O2 STOR

CORRIDOR

STOR

STOR

TOILET

166A

BLUE RM LAB

HISTOLOGY STOR

TRASH UNIT

HAC

166B

02 STOR

159A

HISTOLOGY

157A

HISTOLOGY LAB

COOLER

166C

STOR

166D

ELEC EQUIP

ROOM

OFFICE

155C ULTRA SOUND

CORRIDOR

STOR

FIRE ALARM

162A

CLOSET

ULTRA SOUND

DATA

155A

CHANGING RM

M110

WAITING

M107

OFFICE

M105

TOILET

M108

RECEPTION

M101

TOILET

M106

OFFICE

M104

ELEC

M103

CORRIDOR

M100

COMM

CONTROL RM

145A

TOILET

RECOVERY

M120

HAC

M119

EMS STOR

M18

SUPPLY

M117

COMPUTER RM

M116

ELEV 3

OFFICE / READING

RM

LINEN

READING

HAC

ELEC

149UUU

CORRIDOR

X-RAY 5

PREP

X-RAY 4

149YYY

149VVV

TOILET

141A

X-RAY 3

149WWW

ROOM

LIGHT RM

137A

DARK RM

X-RAY 2

ALCOVE

129B

X-RAY 1

ALCOVE

129A

STRECHER WC

WAITING

CT CONTROL RM

CT SCANNER

CT SCAN ELEC RM

102AELEC

C101A

13-02

CABLING IN CORRIDORS

STAIR

C80

DN

UP CORRIDOR

C120

RADIOLOGY MGR

OFFICE

C102

BONE

DENSITOMETRY

C101

BONE

DENSITOMETRY

C101B

ELEV

ELEV

ELEV

WAITING

149X RECEPTION

149Y CG

EXAM / MEDICINE /

ONCOLOGY /

GASTRO

149AAA

OFFICE

C104A

ELEV LOBBY

C120

OFFICE

C104

CG

BARIATRIC TOILET

149CC

TELE

C103

WOMEN

C105

CONF RM

C106

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

STAIR 3

149TTT

CLINICAL

TEACHING COORD

OFFICE

E107A

TOILET

E105G

OFFICE

E107 HAC

E105F PROCEDURE RM

E108

CORRIDOR

E150

HAC

E103

ELEC

E101

PROCEDURE RM

E114

SPD STOR

E121

CHEIF OFFICE

E107B

ROOM

E105I

VAULT

E105H

PHARMACY

E105

INPT PHARMACY

MGR OFFICE

E105E

ELEC / TELE

105B

LAB

E105A

ELEC

E105B

LAB

E105C

LAB

E105D

PROCEDURE RM

E111

CONTROL RM

E110

SPD CLEAN AREA

E132

ROOM

E144C

BREAK

E105J

OFFICE

E107C

PROCEDURE RM

E109 CORRIDOR

E153

OFFICE

E113

SOILED

E115

TOILET

E112

RECEPTION

E116

NUCLEAR

MEDICINE WAITING

E127

GEN SERGERY

WAITING

E126

ADMIN OFFICE

E125C

READING

E119

LAB

E118

PROCEDURE RM

E117

CORRIDOR

E151

CLEAN UTILITY

E125D

TOILET

E124

DIRTY UTIL

E125

GEN SURGERY

E125B

HAC

E132A

ROOM

E132B

ETD GAS

E144D

DW2

DECONTAMINATION

AREA

DE-IONIZED

WATER

TREATMENT

E142C

PROCESSING

STOR

E144A

ELEC

E144B

GEN SURGERY

E125A

OFFICE

E130A

OFFICE

E120

TR #8B

E122

TR CONSTRUCTION

13-03

200-AE-301

HAC

C109

CORRIDOR

C120

OFFICE

E123

EXAM

E128

SPS ASST CHIEF

E130

SPS CHIEF

E130B

EQUIP

DISPERSING

E136

ELEC

E134

DIST STERILE /

CLEAN SUPPLIES

E138

OFFICE

E138B

TOILET

E140

TOILET

HAC

E142A

VEST

E142D

E142B1

DECONTAM

LOCKER

E142B

LOCKER

E141A TOILET

E141A1

MEN

C107

PHARMACY

E131

EXAM

E133

TRAVEL OFFICE

E133A

STAFF LOUNGE

149EE

CUBICLE

149BBB

CUBICLE

149CCC

CUBICLE

149FF

CUBICLE

149DDD

TOILET

149DD

STAFF TOILET

149VV

CORRIDOR

149BB

OFFICE

149GG

CG 1A3

CONF /

MULTI-PURPOSE

149HH 6

CG CG

CORRIDOR

E152

MEN LOCKER

E138A

ROOM

E140A

DN

UP

STAFF BREAK /

WOMEN LOCKER

E141

STAIR-2

E81

TELEMEDICINE

149UU

CORRIDOR

149Z

CG

1 1

EXAM / MEDICINE /

ONCOLOGY /

GASTRO

149ZZ

NURSE STATION

INTAKE /EXIT

INTERVIE

149W

EXAM

CORRIDOR

TOILET

EXAM

RECEPTION

REVERSE

PRECAUTION RM

149V

TOILET / EXAM

ROOM

149T

PATIENT TOILET

149U

CONSULTATION

RM

CG

149S SOILED UTILITY

149R

ONC:

1 1

INTERVIEW RM -

RHEUMATOLOGY

149YY

STRETCHER /

WHEELCHAIR

ALCOVE

149AA

ELEC

149WW

TELEDATA

149XX

SPS CLEAN STOR

149QQ

HAC

149TT

WASTE VACUUM

PUMP

149RR

1 1A

CG4

CORRIDOR

149SSS

CLEAN LINEN

STOR

149SS

ELEC

149JJ

CRASH CART

149KK

TREATMENT

149FFF

TOILET

149LL

TOILET

149MM

1A3

TREATMENT

149KKK

MED.

149OO

NOURISH.

149EEE

CG

ONC: ONC:

CHEMOTHERAPY

TREATMENT BAY

149PP

CHEMOTHERAPY

TREATMENT BAY

149LLL

CG

ONC:

CHEMOTHERAPY

TREATMENT BAY

149MMM

ONC:

CHEMOTHERAPY

TREATMENT BAY

149NNN

CG CG

NURSE STATION

149NN

CG

1 INTERVIEW ROOM

- ONCOLOGY

149II

CHEMOTHERAPY

TREATMENT BAY

149GGG

ONC:

CHEMOTHERAPY

TREATMENT BAY

149HHH

ONC:

CHEMOTHERAPY

TREATMENT BAY

149III

ONC:

CHEMOTHERAPY

TREATMENT BAY

149JJJ

ONC:

CHEMOTHERAPY

TREATMENT BAY

149RRR

ONC:

CHEMOTHERAPY

TREATMENT BAY

149QQQ

ONCG:C CG

CGCHEMOTHERAPY

TREATMENT BAY

149PPPCG

CG

ONC:CG

CHEMOTHERAPY

TREATMENT BAY

149OOO

CG CG

TOILET GENERAL

PROCEDURE

OFFICE

OFFICE

EXAM

OFFICE

STAIR-C

MECH

OFFICE

RECEPTION

ELEV 2

ELEV 1

ELEV LOBBY

STAIR-E

CORRIDOR

M115 VEST

175A

STOR

MECH SHOP

WAITING

M109

CHANGING RM

M113

WAITING

M112

TOILET

M111

MRI SCAN

M114

LOCKER

155B

CORRIDOR

142A CLEAN SUPPLY

142C

ELEC

TOILET

142B

ROOM

155D ULTRASOUND

SUITE

ROOM

STAIR

SOILED LINEN

CHUTE

156A

MECH

CORRIDOR

EMS STOR

EMS STOR

101A

LOCKER -

RADIOLOGY

STAFF

CAST / EXAM

SUPPLY

STOR

STOR

TELE

152 NO2 STOR

CLOSET

200-AE-301

O2 STOR

O2 STOR

STOR

13-01

TR CONSTRUCTION; DIRECT

ACCESS FROM EXTERIOR

TR #8A

196A

VEST

176A

STAIR

176 BREAK

MEN

CORRIDOR

EXAM

PROCEDURE RM

GENERAL

149Q

EXAM

EXAM

EXAM

EXAM

ELEC

PHYS ADMIN

OFFICE

EXAM

EMERGENCY

GENERATOR

C G

C G

C C

G G

C G

C

G

C G

C G C G

C G C

G

C G

C

G

C G

C G

1 1A

C G

C G C

G C

G

C G

C G

C G

C G

302-SM-A, B, C

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 200/200E - Level 1

Figure 3

APPROXIMATE SCALE IN FEET

200 40

N

File: Togus_Bldg200_200E.dwg Level 1 PO 17938-1911

Legend

Asbestos Sample Location

Positive Material

STOR

270E

STOR

270E1

LAB

270A

CHEMISTRY LAB

LAB

270B

OFFICE

270D

STAIR-D

TOILET

BLOOD BANK

OFFICE

270C

VEST

270F

KITCHEN

264A

OFFICE

265A HEMATOLOGY LAB

ELEC

307 BIO SAFETY

264 264B 264B

BLOOD DONOR RM

OFFICE

262A

OFFICE

CORRIDOR

ROOM

248A

CONF RM

CHUTE

VASCULAR EXAM

RM

VASCULAR STOR

VASCULAR EXAM

RM

TOILET

ELEC

ELEC

230A

PROCEDURE

TOILET

PRE-EQUIP

CLEANING

280B

OFFICE

EXAM

EXAM

BREAK

ELEC

280A

CORRIDOR

PROCEDURE

STOR

EXAM

EXAM

EXAM

ROOM

232A

EXAM

EXAM

EXAM

OPEN OFFICE

ROOM

232B

ROOM

WAITING

CABLING IN CORRIDORS

13-02

ELEC

C201A

PHLEMOTOMY

C202

STAIR-1

DN

UP

BLOOD DRAW /

LAB WORK WAIT

C201

CG CG 1

ELEV

ELEV

ELEV

STRETCHER

ALCOVE

WAITING

RECEPTION /

CHECK-IN

STAIR-C

EXAM

HAC

TOILET

SYPPLY

WAITING

ELEV 3

ELEV 2

ELEV 1

ELEV LOBBY

STAIR-E

STAFF TOILET

208B

PATIENT TOILET

STAFF

HAC

CORRIDOR

TOILET

201A

ROOM

201B

ROOM

201C

ROOM

201D

LAB

CONSULT, INTAKE

/ EXIT INTERVIEW

RM

CORRIDOR

MECH

OFFICE

201E

WAITING

282A

CONSULT RM

CG

TOILET PREP /

RECOVERY RM

10 3

CG9 1

BARIATRIC TOILET

CONF RM

C204

OFFICE

C208

13-03

TR CONSTRUCTION

STAIR

CORRIDOR

E270

SOUND BOOTH

E215

SOILED UTILITY

E211

MICROSCOPE RM

E213

CONTROL BOOTH

E217

ELEC

E209

PRE OP

E202

VISUAL FIELD RM

E204

MECH

E219

SOUND BOOTH

CONTROL BOOTH

CORRIDOR

E275

200-AE-302

AUDIOLOGY

OFFICE

C212

AUDIOLOGY EXAM

C210

CORRIDOR

C206

TELE

C203

WOMEN

C205

MEN

C207

HAC

C209

CORRIDOR

E272

EXAM

E203

SUPPLY

E204A

EXAM

E206

TR #9B

E201

PT EXAM

E240

EUDIOLOGY STOR

E241

EXAM

E205

AUDIO TECH

OFFICE

E242

EXAM

E220

EXAM

E222

ROOM

E229

EXAM

E228

EXAM

E226 WAITING

E207

TOILET

E224

CORRIDOR

E273 CORRIDOR

WOMEN

E221 HYDROTHERAPY

E236B

OFFICE

E236C

TOILET

E236D

EXAM

E251C

CONTROL BOOTH

E246B

SOUND BOOTH

E246C

HEALTH SYSTEM

SPECIALIST

C243

CHIEF AUDIOLOGY

C243A

PHYSIOLOGY LAB /

PULMONARY

EXERCISE

CG CG1

CG

CG

CG

CORRIDOR

E271

AUDIOLOGY EXAM

E245

HAC

E247

AUDIOLOGY

E249

EXAM

E239

CG DN

UP

ELEC

E248

AUDIOLOGIST

E252

STOR

E250

CORRIDOR

E274

EXAM

E251

STOR

E251A

STAFF

E251B

MECH

E254

EXAM

E223A EXAM

E218

EXAM

E216

EXAM

E214

EXAM

E212

MINOR SURGERY

OPHTHALMOLOGY

E223

CHEIF OT OFFICE

E225

CORRIDOR

E276

OFFICE

E227A

OFFICE

E227B

TECH OFFICE

E227C ADL KITCHEN

E234A

TOILET

E233

EXAM

E212A

ELEC

E232

WAITING

E231 OFFICE /

RECEPTION

E236A

PHYS THERAPY

CLINIC

E236

AUDIOLOGIST

E255

STAIR-2

E081

CGAPNEA RM

CG CG

PHYSIOLOGY LAB /

PULMONARY

EXERCISE

INTERVIEW

CG

1A 5 CG

CORRIDOR

CONSULT / APNEA

RM

CG

4CG CG

1A3 10 1 1

MECH

HAC

MED GAS

TOILET

CONSULT RM

CONSULT RM

CONSULT RM

1 1

CORRIDOR

ELEV LOBBY

C220

CG

CG

CORRIDOR

CG

ELEC

INTERVIEW -

ENDO.

TELEDATA

NOURISH.

RECEPTION

STOR

205A

PROCEDURE RM,

BRONCHOSCOPY

PREP / RECOVERY

CG CG

CRASH CART

1A

CG CG

CG CG

CORRIDOR

CG

NURSE STATION

CLEAN LINEN

STOR

MEDICATION AREA

1 8CG CG

CG 1 1 1 2

SPS CLEAN STOR

CG

EQUIP / STOR

STAFF LOUNGE

CORRIDOR

OFFICE, DIRECTOR

OF RESPIRATORY

THERAPY

CLOSET

CUBICLES - 5

TOTAL

CG

CG

CG

CUBICLE, CHIEF

OF PULMONARY

MEDICINE

CG

1A

SOILED UTILITY

STAFF TOILET

3 10

CUBICLE, STAFF

PHYSICIAN -

INFECT

ELEC

CUBICLE, STAFF

PHYSICIAN -

ENDOC.

CUBICLES - 4

TOTAL

CG

ROOM

208A

STAIR-F

ELEC

CORRIDOR

EXAM

EXAM

SD

CLEAN LINEN

TR #9A

EXAM

BATH / SHOWER

214 DIRTY LINEN

TELE HEALTH

STAFF

HAC

TELE

LAB MGR OFFICE

MECH

208D

13-03 TR CONSTRUCTION

STAFF

208C

200-AE-302

PATHOLOGY LAB

OFFICE

OFFICE

262B

STOR

OT CLINIC

E234

EXAM

E238A

CORRIDOR

E238

OT OFFICE

E234B

TREATMENT

E238B

STOR

E234C

OFFICE

E234D

STOR

E238D

OFFICE

E238C

C

G

C G

C G

C G

C G

1A

1A C

G

1A

C G

C

G

C

G

C G

C G

1A

C G

C G

302-PHBW-A, B, C

313-BRBP-A, B, C

308-4BR-A, B, C

305-WL-A, B, C

310-LGGS-A, B, C

308-4M-A, B, C

File: Togus_Bldg200_200E.dwg Level 2 PO 17938-1911

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 200/200E - Level 2

Figure 4

APPROXIMATE SCALE IN FEET

200 40

N

Legend

Asbestos Sample Location

Positive Material

STAIR-D

HAC

372A

ROOM

SUPPLY

BREAK

CLEAN LINEN

385A MULTI-PURPOSE

PROCEDURE

PROCEDURE RM

TOILET

MED STORE

KITCHEN

ROOM

358A

ROOM

358B

NURSE STA

OFFICE

BED

358K

200-AE-303

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

TOILET

EXAM

ROOM

358C

EXAM

OFFICE

13-04

TR CONSTRUCTION

EXAM

PATIENT RM

TOILET

336A

EXAM

AIR HANDLER RM

334A

ELEC

ROOM

TOILET

PATIENT RM

PATIENT RM

TOILET

344A

MECH

NURSE STA

TOILET

3445A

PATIENT RM

PATIENT RM

376 TOILET

343A

HAC

TOILET

339A

PATIENT RM

NURSE STA

PATIENT RM

TOILET

340A PATIENT RM

MED CART STOR

342A

MED RM

338A

MED RM

CORRIDOR

CLEAN LINEN

TOILET

335A

TOILET

PATIENT RM

SOILED

CLEAN LINEN

329A

SPD STOR

TOILET

ROOM

329B

O2 STOR

CORRIDOR

LOCKER

302A

CLEAN UTILITY

ELEC

C301A

CONF RM

C302

STAIR-1

DN

UP ELEV

ELEV

ELEV

ELEV LOBBY

C301

OFFICE

C304 ELEV LOBBY

C320

NEPHROLOGY

OFFICE

C306

CORRIDOR

C321

NEPHROLOGY

OFFICE

E304

OFFICE

E302

TELE

C303

TOILET

C305

TOILET

C307

HAC

E361

STAIR

HAC

E311

OR STOR

E363

CLASS RM

E365

200-AE-303

13-03

TR CONSTRUCTION

1-BED RM

E310

1-BED RM

E312

ANTE RM

E313

CONSOLATION RM

E328

1-BED RM

E314

SICU

1-BED RM

E315

BREAK

E332

NOURISHMENT

E333

MED RM

E331

SUPPLY

E330

NURSE STA

E306

CLEAN LINEN

E326

ANTE RM

E316

1-BED RM

E317

HAC

E301H

STOR

E318

ELEC

E319

1-BED RM

E320

1-BED RM

E321

1-BED RM

E322

1-BED RM

E323

N MGR OFFICE

E325

TOILET

E324A

LOCKER

E324

SOILED UTILITY

E301E

CLEAN UTILITY

E301F

BREAK

E301G

WATER TANK

E301G1

SOILED UTILITY

E327

LOCKER

E329

TOILET

E329A

DIALYSIS SUITE

E301

SOILED EQUIP

E301D

SUPPLY

E360C

TOILET

E360D

WOMEN LOCKER

E384

SOILED UTILITY

E360E

ELEC

E343

HAC

E386

MEN LOCKER

E382

OR 5

E380

OR 4

E378

HAC

E374

ELEC

E376

CLEAN EQUIP

E301C ROOM

E342

PACU

E360

PRE OP AREA

E362

OFFICE

E362B

LOUNGE /

DICTATING RM

E390A

CLEAN DW

SURGICAL SVC

E390

STOR

E372A

ANEST OFFICE

E369A

STERILIZER AREA

E390B

DIRTY DW

SOILED UTILITY

E373

STOR

1-BED RM

E309

1-BED RM

E308

1-BED RM

E307

ELEC

E305

ISOLATION BED

RM

E303

MEN LOCKER

E301A

WOMEN LOCKER

E301B

TOILET

E301A1

TOILET

E301B1

CORRIDOR

E392

EXAM

E340

TR #10B

E341

TOILET

E362A1

LOCKER

E362A

CLEAN UTILITY

E360A

OR 1

E364

CORRIDOR

E391

ELEC

E366

ROOM

EQUIP

OR 2

E368

O2/CO2

HAC

E370

ROOM

DNSTAIR-2

STOR

E367

OR 3

E372

STOR

E369

CLEAN LINEN

SPD CLOSET

PATIENT RM

TOILET

306A

STAIR-C

MECH

332B

BREAK

332A

PATIENT RM

TOILET

TOILET

PATIENT RM

ELEV 3

ELEV 2

ELEV 1

ELEV LOBBY

TOILET

301A

STAIR-E

PATIENT RM

TOILET

303A

PATIENT RM

MECH

305A

STAIR-F

KITCHEN

CORRIDOR

SOIL

300B

TOILET

308A

PATIENT RM

NURSE STA

OFFICE

310B

WORK AREA

310A

HAC SINK

300C

PATIENT RM

331 TOILET

312A

ELEC

300D

TOILET

316A

PATIENT RM

PATIENT RM

329 TOILET

318A

MEDS

PATIENT RM

HAC

PATIENT RM

ELEC

RECEPTION

AIR HANDLER RM

307A

ROOM

ROOM

358E

ROOM

358D

BED

358G

BED

358H

TR #10A

358J

WAITING

ISO PATIENT RM

TOILET

309A

ANTE RM

13-02

CABLING IN CORRIDORS

TOILET

313A TOILET

317A

PATIENT RM

PATIENT RM

TOILET

319A

STAFF SURGEON

E348

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

CORRIDOR

E345

STAFF SURGEON

E350

SURGERY ADMIN

E349

TREATMENT

E358

ROOM

E347

13-04

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

CHEIF

NEUROSURGERY

E352

STAFF SURGEON

E354 STAFF SURGEON

E356

42 48

File: Togus_Bldg200_200E.dwg Level 3 PO 17938-1911

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 200/200E - Level 3

Figure 5

APPROXIMATE SCALE IN FEET

200 40

N

Legend

Asbestos Sample Location

Positive Material

STAIR-D

MECH

OFFICE

CABLING THROUGHOUT

DEPARTMENT AS INDICATED

13-04

OFFICE

OFFICE

DENTAL OFFICE

CORRIDOR

DENTAL

OFFICE

ELEC

ELEV 3

LAB

DECON RM

DRESSING RM

PROCEDURE RM

PROCEDURE RM

PROCEDURE RM

STAIR-C

TOILET

TOILET

CORRIDOR

TREATMENT

STOR

DRESSING RM

546A

CORRIDOR

DRESSING RM

545A

DRESSING RM

544A

OFFICE

RECOVERY

536A

RECOVERY

536B

RECOVERY

536C

RECOVERY

536D

RECOVERY

536E

RECOVERY

536F VEST

WAITING

TOILET

530A

HAC

528 CORRIDOR

CONFERENCE RM

TOILET

C502

ELEC

C501A

STOR

C501

STAIR-1

CLINICAL

DIETITIAN OFFICE

C504

ELEV LOBBY

C520

OFFICE

OFFICE SUPPLY

C504A

13-03

TR #12

C501B

TR CONSTRUCTION

ELEV

ELEV

ELEV

? 200-AE-304

CHIEF OFFICE

ROOM

535A

NURSE STA

WAITING

ELEV 2

ELEV 1

CORRIDOR

VEST

ELEV LOBBY

STAIR-E

SUPPLY

OPERATORY

503 ORAL SURGERY

OPERATORY

DARK RM

ELEC

CLEAN LINEN /

SUPPLY

PATIENT TOILET

SOILED UTILITY

SOILED LINEN

HAC

PANOGRAPHY

OPERATORY

OPERATORY

OPERATORY

SUPPLY

CORRIDOR

RESIDENT

OPERATORY

RESIDENT

OPERATORY

DENTAL LAB

STAIR-F

RESIDENT

MEDS

OPERATORY

OPERATORY

RESIDENT

OPERATORY

525 STOR

527A

VEST

TELE

OFFICE

WOMEN LOCKER

517C

CONF / BREAK RM

517A

STAFF TOILET

517B

MEN LOCKER

517D CABLING IN CORRIDORS

13-02

OFFICE

LEVEL 5 FLOOR PLAN

45, 46

315-1GW-A, B, C

315-4G-A, B, C

File: Togus_Bldg200_200E.dwg Level 5 PO 17938-1911

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 200/200E - Levels 5, 6, 7

Figure 6

APPROXIMATE SCALE IN FEET

200 40

N

Legend

Asbestos Sample Location

Positive Material

STAIR

FREEZER

220C #3

COOLER

220F #4

COOLER

220D #5 ELEV

ROOM

ROOM

COOLER

220E #6

ROOM

FREEZER

220B #2

FREEZER

220A #1

13-03

CABLING

KITCHEN

FREEZER

217A

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

215A

ROOM

TH

RE

TR #19

200A

ROOM

204A

ROOM

DINING

ROOM

ROOM

ROOM

STOR

STAIR

ROOM

ROOM

13-02

CABLING

LEVEL 2

ROOM

220A

ROOM

ROOM

ROOM

13-03

TR CONSTRUCTION

ROOM

ROOM

205A

67, 68 315-4W-A, B, C

Togus VA Medical Center 1 VA Ctr.

Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023

Sample Locations Building 204

Figure 7

APPROXIMATE SCALE IN FEET

100 20

N

File: Togus_Bldg204.dwg 204 PO 17938-1911

Legend

Asbestos Sample Location

Positive Material

OFFICE

300F

OFFICE

318B

OFFICE

318A

OFFICE

EXAM

316B

EXAM

316C

EXAM

314A

OFFICE

312A

ROOM

316A ROOM

316D

CORR

STOR

STAIR

OFFICE

OFFICE

PURCHASING

OFFICE

313A

OFFICE

311A

ROOM

307B

ROOM

307A

ROOM

307D

TR #22

307E

ROOM

307C

ROOM

ROOM

ROOM

SUPPLY

OFFICE

312B

OFFICE

300E

ROOM

TOILET

ELEC

OFFICE

300B

ROOM

OFFICE

300G

OFFICE

300H

OFFICE

300I

OFFICE

300K

OFFICE

300L

LAB

300M

OFFICE

300D

OFFICE

300C

STOR

300A

STAIR

CORR

MULTI-PURPOSE

MULTI-PURPOSE

332A

MULTI-PURPOSE

ELEV

PSYCH SERVICES

OFFICE

337J

OBSERVATION

300N

CONF

CHASE

MEN

ELEC

OFFICE

337I

CORR

COMP

336A

OFFICE

336B

OFFICE

336C

DISTRICT COUNCIL

OFFICE

336D

LEVEL 3

LIBRARY

336E

ROOM

336F

STAIR

CLOSET

OFFICE

337H

SOCIAL WORK

SERVICES

OFFICE

337G

OFFICE

337A

OFFICE

337B

OFFICE

337C

OFFICE

337D

OFFICE

337E

OFFICE

337F

ROOM

100A

ROOM

ROOM

116A ROOM

ROOM

ROOM

118A…