S02 - SOW - Att 11 - Haz Mat Report - EHRM Infra Upgrades - Constr - Togus.pdf
PDF 5 MB Posted
- Attached to
- Electronic Health Record Modernization Infrastructure Upgrades - Construction - Togus, ME
- Solicitation number
- 36C77626R0062
About this file
This is a Limited Asbestos and Lead Inspection Report prepared by American Engineering Testing, Inc. (AET) for the Togus VA Medical Center in Augusta, Maine, dated August 15, 2023, in support of Electronic Health Record Modernization (EHRM) Infrastructure Upgrades construction activities.
AET conducted a limited inspection on June 20-22, 2023, by a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector. The inspection covered select IT equipment rooms in 27 buildings at the facility and included collection of 75 samples of suspect asbestos-containing building materials (ACBM) and testing of 77 suspect painted/coated surfaces. All 75 asbestos samples tested negative for asbestos content. However, three lead-containing paint areas were identified in Building 69, Floor 01, Room 102: white plaster walls and ceilings containing 17.6 mg/cm² lead (228 SF), light blue plaster walls containing 1.30 mg/cm² lead (64 SF), and a white wood door frame containing 36.30 mg/cm² lead (18 SF). The report recommends that lead-containing materials be removed by a State of Maine Department of Environmental Protection licensed lead abatement company or an EPA Lead Renovation, Repair and Painting (RRP) trained and certified company. Contractors must obtain required permits, submit State of Maine Department of Environmental Protection Notification Forms prior to demolition/renovation activities, and prepare an environmental contingency management plan. The report should be used in conjunction with a prior asbestos/lead report dated March 25, 2011, prepared by Mabbett & Associates, Inc., as the current inspection only addressed materials not previously identified.
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
American Engineering Testing 550 Cleveland Avenue North St. Paul, MN 55114-1804 teamAET.com • 800.972.6364
Geotechnical ● Materials Forensic ● Environmental
Building Technology Petrography/Chemistry
LIMITED ASBESTOS
AND LEAD INSPECTION REPORT
Togus VA Medical Center 1 VA Center Augusta, ME 04330
AET Project No. P-0019594
Report Date:
August 15, 2023
Prepared for:
GDM
1401 W. 34th Ave., Ste. 200 Anchorage, AK 99503
550 Cleveland Avenue North | Saint Paul, MN 55114 Phone (651) 659-9001 | (800) 972-6364 | Fax (651) 659-1379 | teamAET.com | AA/EEO
This document shall not be reproduced, except in full, without written approval from American Engineering Testing, Inc.
GDM
1401 W. 34th Ave., Ste. 200 Anchorage, AK 99503
Attn: Mr. Conrad Chandler, Project Manager
RE: Limited Asbestos and Lead Inspection Report
Togus VA Medical Center 1 VA Center Augusta, ME 04330
Dear Mr. Chandler:
American Engineering Testing, Inc. has completed the enclosed report of Limited Asbestos and Lead Inspection services for the Togus VA Medical Center located in Augusta, Maine. This service was performed in accordance with our proposal agreement no. P-0019594.
We appreciate the opportunity to have been of service to you on this project. If you have any questions regarding the information presented in this Limited Asbestos and Lead Inspection Report or if we can be of additional assistance, please contact me.
Sincerely, American Engineering Testing, Inc.
Bruce A. Boehm Carlson Sr. Environmental Project Manager E-mail: bboehmcarlson@teamAET.com Phone: (651) 999-1387
Enclosure
Limited Asbestos and Lead Inspection Report Togus VA Medical Center, Augusta, ME
Page ii
TABLE OF CONTENTS
Page
TRANSMITTAL LETTER………………………………………………………………………………i TABLE OF CONTENTS........................................................................................................... ii EXECUTIVE SUMMARY .........................................................................................................iii
1.0 INTRODUCTION
1.1 Purpose
1.2 Scope of Inspection
1.3 Limitations
2.0 ASBESTOS AND LEAD INSPECTION PROCEDURES
2.1 General Information
2.2 Function of Inspection
3.0 ASBESTOS AND LEAD INSPECTION RESULTS
3.1 Asbestos-Containing Materials
3.2 Lead Paints/Coatings
4.0 RECOMMENDATIONS
5.0 GENERAL REMARKS
5.1 Standard of Care
5.2 Certifications
TABLES
1. Summary of Non-Asbestos-Containing Building Materials
2. Summary of Lead Containing Paints/Coatings
3. Summary of Non-Lead Containing Paints/Coatings
FIGURES
1. General Notes
2. Building 200 Ground Level Asbestos Containing Building Materials Sample and Lead Paint Test Locations
3. Building 200 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
4. Building 200 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
5. Building 200 Level 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
6. Building 200 Level 5 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
7. Building 204 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
8. Building 205 Levels 1 and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
9. Building 206 Levels 1, 2, and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
10. Building 207 Levels 1, 2, and 3 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
11. Building 208 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
12. Building 210 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
13. Building 211 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
14. Building 212 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
15. Building 221 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
16. Building 232 Level 2 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
Page iii
17. Building 255 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
18. Building 300 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
19. Building 69 Level 1 Asbestos Containing Building Materials Sample and Lead Paint Test Locations
APPENDICES
A. Explanation of Tables
B. INTENTIONALLY BLANK
C. Asbestos Laboratory Analytical Results D. Lead Testing Results E. Pre-Demolition Environmental Checklist and Guide F. Photographic Log G. Laboratory Credentials H. AET Certifications
Page iv
EXECUTIVE SUMMARY
American Engineering Testing, Inc. (AET) was authorized by GDM (Client) to conduct a limited asbestos and lead inspection of various buildings located at the Togus VA Medical Center, 1 VA Center, Augusta, Maine (Site). The purpose for the limited asbestos and lead inspection was to identify, sample and quantify suspect asbestos-containing building materials (ACBMs) and to test and quantify lead containing paints/coatings as required by the State of Maine Department of Environmental Protection. Services performed by AET were conducted in accordance with our Proposal No. P- 0019594.
Bruce Boehm Carlson, a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector, completed the inspection on June 20-22, 2023. AET collected 75 samples of suspect ACBM and tested 77 suspect painted/coated lead surfaces at the Site.
The inspection was limited to select IT equipment rooms in the following buildings:
• 1, 3, 4, 27, 32, 69, 200, 201, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 221, 232, 235, 238, 239, 240, 248, 255 and 300.
AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.
Please review the prior report for information related to the materials that were not sampled or tested by
AET.
The materials that were sampled and tested by AET were found to not contain asbestos.
The following painted/coated surfaces that were tested by AET were found to contain greater than 1 milligram per square centimeter (mg/cm2) lead:
• Shot 54 - Photo 2 – Building 69, white plaster walls and ceilings were found to contain 17.6 mg/cm2 lead. Approximately 228 total square feet (SF) was identified in Fl. 01 Rms. 102 and 102 NE Closet.
• Shot 55 - Photo 2 – Building 69, light blue plaster walls were found to contain 1.30 mg/cm2 lead.
Approximately 64 total square feet (SF) was identified in Fl. 01 Rm. 102.
• Shot 56 - Photo 2 – Building 69, white wood door frame was found to contain 36.30 mg/cm2 lead. Approximately 18 total square feet (SF) was identified in Fl. 01 Rm. 102.
Page v
The lead containing materials must be removed and properly disposed of by a State of Maine Department of Environmental Protection licensed lead abatement company utilizing trained and certified supervisors and workers OR a Lead Renovation, Repair and Painting (RRP) trained and certified company utilizing trained personnel.
Salvage, reuse, recycle or properly dispose of the numerous regulated waste materials identified at the Site prior to commencing with renovation activities.
Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition/renovation activities.
If untested suspect asbestos-containing materials or potential lead containing paints/coatings are identified during renovation, do not disturb the materials and contact AET for consultation or follow-up testing. Notify the general contractor of the location and quantity of asbestos and regulated waste items at the Site.
1.0 INTRODUCTION
1.1 Purpose
This report presents the results of the limited asbestos and lead Inspection performed at the Togus VA Medical Center, 1 VA Center, Augusta, Maine (Site). American Engineering Testing, Inc. (AET) completed the inspection at the request of GDM (Client). The inspection was performed to facilitate moving and installation of IT cabling and equipment in certain buildings at the Site.
The purpose for the limited asbestos and lead inspection was to identify, sample and quantify suspect asbestos-containing building materials (ACBMs) and to test and quantify lead containing paints/coatings as required by the State of Maine Department of Environmental Protection.
1.2 Scope of Inspection
AET’s scope of services included the following tasks:
• Conduct a visual inspection for the presence of ACBM.
• Collect representative bulk samples of suspect ACBMs for analysis.
• Submit the bulk samples of suspect materials to an accredited National Voluntary Laboratory Accreditation Program (NVLAP) laboratory for analysis of asbestos content. Laboratory certifications can be found in Appendix G.
• Identify, test, and quantify the various painted/coated materials for lead content utilizing a portable x-ray fluorescence (XRF) analyzer.
• Prepare a final report summarizing the results of the assessment.
1.3 Limitations
The inspection was limited to select IT equipment rooms the following buildings:
• 1, 3, 4, 27, 32, 69, 200, 201, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 221, 232, 235, 238, 239, 240, 248, 255 and 300.
Additionally, AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.
Please review the prior report for information related to the materials that were not sampled or tested by
AET.
2.0 ASBESTOS AND LEAD INSPECTION PROCEDURES
2.1 General Information
The Inspection was conducted on June 20-22, 2023 by Bruce Boehm Carlson, a State of Maine Department of Environmental Protection certified Asbestos Building Inspector and Lead Inspector. AET collected 75 samples of suspect asbestos-containing building materials (ACBM) and tested 77 suspect painted/coated lead surfaces at the Site.
Suspect asbestos inspection, sampling and analytical procedures were performed in accordance with EPA Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763, Subpart E; EPA National Emission Standard for Hazardous Air Pollutants (NESHAP), 40 CFR Part 61; and the Occupational Safety and Health Administration (OSHA) rules and regulations, Asbestos Standards for General Industry 29 CFR 1910.1001 and Asbestos Standards for the Construction Industry 29 CFR 1926.1101.
Asbestos samples were analyzed utilizing polarized light microscopy (PLM) by Eurofins CEI, a NVLAP accredited laboratory (NVLAP Lab No. 101768-0). Other potential regulated wastes were inventoried according to the Pre-Demolition Environmental Checklist and Guide.
Potential lead-containing paint sampling and analytical procedures were performed in accordance with the State of Maine Department of Environmental Protection, U.S. Department of Housing and Urban Development (HUD), the EPA and the OSHA. Testing was conducted utilizing a Niton portable XRF analyzer.
2.2 Function of Inspection
The EPA NESHAP requires building owners to inspect for ACBM in areas of a building where renovation or demolition will take place. Some States regulate the removal and disposal of regulated waste as outlined in the Pre-Demolition Environmental Checklist and Guide.
All manufactured and some natural products are considered suspect ACBM. Materials that are considered to be non-suspect are wood, metal, glass, and fiberglass. Prior to renovation or demolition of a building, all regulated friable ACBM must be removed from the affected area. In addition, non-friable materials, which are in a damaged condition or are likely to become friable during the process of renovation or demolition also require removal. Non-friable materials, which are in good condition at the time of inspection and most likely will not become friable during demolition may, under certain circumstances, remain in place prior to demolition. EPA and OSHA define any building material which contains greater than one percent asbestos to be asbestos-containing material. It is also required to point-count by PLM the percent asbestos in friable asbestos-containing material (ACM) estimated to contain less than one percent asbestos.
The State of Maine Department of Environmental Protection regulates the removal and disposal of regulated waste. This also includes delaminating lead-based paint.
HUD and the EPA identify lead-based paint as any paint, varnish, shellac, or other coating that contains lead concentrations equal or greater than one milligram per square centimeter (1.0 mg/cm2), 0.5 % by weight or 5,000 parts per million (ppm). OSHA recognizes lead-based paint as paint that contains any detectable amount of lead. Although the use of lead in paint was banned in 1978 by the Consumer Product Safety Commission (CPSC), consumer paints can still contain up to 0.06 % lead by weight or 600 ppm. Lead-based paints are still commonly used in many commercial applications.
3.0 ASBESTOS AND LEAD INSPECTION RESULTS
3.1 Asbestos-Containing Materials
See Figures 1 through 19 for the locations of the asbestos containing building material samples. See Table 1 for the materials that do not contain asbestos. The asbestos analytical laboratory report is included in Appendix C. Photographs are included in Appendix F. Laboratory credentials are included in Appendix G.
AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.
Please review the prior report for information related to the materials that were not sampled or tested by
AET.
The materials that were sampled and tested by AET were found to not contain asbestos.
Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition activities.
3.2 Lead Paints/Coatings
See Figures 1 through 19 for the locations of the lead testing locations. AET tested various paints/coatings in various IT equipment rooms at the Site. A summary of the lead containing paints/coatings can be found in Table 2 and a summary of the non-lead containing paints/coatings can be found in Table 3. Please see Appendix D for the locations and results of all the tested paints/coatings. A copy of the XRF Performance Characteristics Sheets can be found in Appendix G.
AET was provided a prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc. AET utilized this report to reduce the number of samples and tests needed during their limited inspection. AET only sampled and tested materials that were not previously identified in the prior report. Likewise, no material inventory was created for this report due to the majority of the materials having been present, inspected, and inventoried as part of the prior report. Therefore, this report is to be used in conjunction with the prior report when making renovations.
Please review the prior report for information related to the materials that were not sampled or tested by
AET.
The following painted/coated surfaces that were tested by AET were found to contain greater than 1 milligram per square centimeter (mg/cm2) lead:
• Shot 54 - Photo 2 – Building 69, white plaster walls and ceilings were found to contain 17.6 mg/cm2 lead. Approximately 228 total square feet (SF) was identified in Fl. 01 Rms. 102 and 102 NE Closet.
• Shot 55 - Photo 2 – Building 69, light blue plaster walls were found to contain 1.30 mg/cm2 lead.
Approximately 64 total square feet (SF) was identified in Fl. 01 Rm. 102.
• Shot 56 - Photo 2 – Building 69, white wood door frame was found to contain 36.30 mg/cm2 lead. Approximately 18 total square feet (SF) was identified in Fl. 01 Rm. 102.
The lead containing materials must be removed and properly disposed of by a State of Maine Department of Environmental Protection licensed lead abatement company utilizing trained and certified supervisors and workers OR a Lead Renovation, Repair and Painting (RRP) trained and certified company utilizing trained personnel.
Salvage, reuse, recycle or properly dispose of the numerous regulated waste materials identified at the Site prior to commencing demolition activities. A copy of the Pre-Demolition Environmental Checklist and Guide is in Appendix E.
4.0 RECOMMENDATIONS
Based on the results of this investigation, AET recommends the following:
• The facility owners must notify employees, tenants, contractors, and vendors working in the building of the presence, quantity, and location of identified or assumed ACBM and lead containing paints/coatings.
• Prior to commencing renovation/demolition activities conduct the following:
o Utilize a licensed asbestos abatement company with certified supervisors and workers to remove the ACBM identified in the prior report dated March 25, 2011, titled General Asbestos/Lead Containing Paint Summary Report prepared by Mabbett & Associates, Inc.
o Utilize a State of Maine Department of Environmental Protection certified lead abatement company utilizing certified supervisors and workers OR an EPA Lead RRP trained and certified contractor to manage the painted/coated surfaces throughout and on the building in accordance with the EPA Lead RRP Rules.
• Salvage, reuse, recycle or properly dispose of the numerous regulated objects identified at the Site prior to commencing renovation activities.
• Complete and submit the State of Maine Department of Environmental Protection Notification Forms as required prior to commencing the demolition activities.
• Obtain all required local permits.
• Prepare a general environmental contingency management plan for addressing potential situations that may arise during the renovation project. Example contingencies might include management of petroleum, management of spilled fluids or other unknown regulated items encountered during the demolition and Site excavation.
• During the renovation/demolition activities, if additional suspect asbestos containing materials or potential lead containing paints/coatings are discovered, do not disturb the materials and contact AET for consultation or follow-up testing.
5.0 GENERAL REMARKS
5.1 Standard of Care
Bulk asbestos and lead testing, collection and analysis was conducted in accordance with the State of Maine Department of Environmental Protection required methodology. Other potential regulated wastes were inventoried.
This report summarizes the results of the inspection completed by AET. This inspection and review of the subject property has been limited in scope in that it was undertaken with the knowledge that visual observations and random sampling methods alone might not reveal the presence, full nature, and extent of all ACBM, lead paint, and other regulated wastes in the building. AET makes no representations as to the asbestos or lead content of materials not sampled or that were not accessible to our inspector(s) (i.e., between walls, beneath floors, in sealed pipe chases, etc).
The ACBM, lead paint, and other regulated wastes sample locations and building dimensions were visually estimated. Therefore, the sample locations, building dimensions and approximate square footages of ACBM and lead paint should be considered accurate only to the degree implied by the methods used.
This asbestos and regulated wastes inspection is not intended to be the sole basis for asbestos, lead paint, and regulated waste removal bids. Confirmation of the presence, condition, and quantity of the ACBM’s, lead paints, and other regulated waste should be conducted by prospective removal contractors prior to accepting removal bids. This report is provided for the exclusive use of the client noted on the cover page and is subject to the terms and conditions in the applicable contract between the Client and AET. The Client is the only party to whom AET has explained the limitations of this inspection and has been involved in the shaping of the scope of services. Any third-party review of this report will be subject to the terms and conditions governing contractual work between the Client and
AET. The unauthorized use of, reliance on, or release of information contained in this report, without the expressed written consent of the Client is strictly prohibited and will be without risk or liability.
The services performed by AET on this project have been conducted with a level of care and skill that meets or exceeds industry standards set by reputable members of the profession, practicing in the same locality under similar budget and time constraints. This inspection does not guarantee all ACBM, lead paint, or other regulated waste were found.
5.2 Certifications
I, the undersigned, do hereby certify that I am an accredited Asbestos Building Inspector and Lead Inspector in the State of Maine, certified by the State of Maine Department of Environmental Protection, Nos. AI-0923 and LI-0502. A photocopy of my current asbestos inspector and lead inspector certification are included in Appendix H.
Report Authored By:
Bruce A. Boehm Carlson Eric C. Hesse, PE Senior Environmental Project Manager Environmental Division Manage
Tables
Table 1 - Summary of Non-Asbestos Containing Building Materials
Area Location Room Number
Material ID Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson
Building Number:1 VA Ctr.
Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.
Sample Set Name:1 Building Address 2:
City, State Zip:Augusta, ME 04330
Lead Paint
Bldg. 200
Floor 02
302 2x2 Ceiling Tile
PHBW Pinhole Birdwing
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 200
Floor 02
308 Base Cove & Mastic
4BR 4" Brown
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 200
Floor 02
313 Sheet Floor & Mastic
BRBP Brown Board Pattern
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 200
Floor 02
E201
308 Base Cove & Mastic
4M 4" Maroon
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 200
Floor 02
E201
310 12x12 Floor Tile & Mastic
LGGS Light Gray w/ Gray Streaks
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Page 1 of 5Monday, August 14, 2023
10:06:33 PM
American Engineering Testing, Inc.
St. Paul, MN 55114
Location Room Number
Material ID Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson
Building Number:1 VA Ctr.
Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.
Sample Set Name:1 Building Address 2:
City, State Zip:Augusta, ME 04330
Lead Paint
Bldg. 200
Floor 05
315 Ceramic Tile
1GW Green & White
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 200
Floor 05
C501
315 Ceramic Tile
4G 4" Gray
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 200E
Floor 01
122E
302 2x2 Ceiling Tile
SM Smooth
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 204
Floor 02
315 Ceramic Tile
4W 4" White
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 206
Floor 02
303 2x4 Ceiling Tile
PHBW Pinhole Birdwing
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 206
Floor 02
310 12x12 Floor Tile & Mastic
LGM Light Gray Mottled
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Page 2 of 5Monday, August 14, 2023
10:06:33 PM
American Engineering Testing, Inc.
Room Number
Material ID Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson
Building Number:1 VA Ctr.
Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.
Sample Set Name:1 Building Address 2:
City, State Zip:Augusta, ME 04330
Lead Paint
Bldg. 208
Floor 01
308 Base Cove & Mastic
4G 4" Gray
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 208
Floor 01
310 12x12 Floor Tile & Mastic
LTGM Light Gray Mottled
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 208
Floor 01
310 12x12 Floor Tile & Mastic
LBRM Light Brown Mottled
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 210
Floor 01
303 2x4 Ceiling Tile
PHF Pinhole Fissure
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 255
Floor 01
302 2x2 Ceiling Tile
PHC Pinhole Crater
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 255
Floor 01
310 12x12 Floor Tile & Mastic
LTGGS Light Gray w/ Gray Streaks
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Page 3 of 5Monday, August 14, 2023
10:06:34 PM
American Engineering Testing, Inc.
Room Number
Material ID Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson
Building Number:1 VA Ctr.
Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.
Sample Set Name:1 Building Address 2:
City, State Zip:Augusta, ME 04330
Lead Paint
Bldg. 255
Floor 01
321 Caulk
BR Brown
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 255
Floor 01
305 Sheetrock & Taping Compound
WC Walls and Ceilings
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Bldg. 255
Floor 01
308 Base Cove & Mastic
4T 4" Tan
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 255
Floor 01
310 12x12 Floor Tile & Mastic
BGM Beige Marbled
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 255
Floor 01
321 Caulk
R Red
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 300
Floor 01
305 Sheetrock & Taping Compound
WLC Walls and Ceilings
M ND 7 4
Notes: Located in various areas throughout the building.
NFriable
Page 4 of 5Monday, August 14, 2023
10:06:34 PM
American Engineering Testing, Inc.
Room Number
Material ID Subcat ID
Material ID Description Subcategory Description
Material Code
Asbestos Content
Quantity Physical Assessment:
Friability Condition
Damage Potential:
Water Air Vib Acc
Cond Rating
AHERA
Rating
Client Name:GDM Project Number:P-0019594 Project Manager:Bruce A. Boehm Carlson
Building Number:1 VA Ctr.
Building NameTogus VA Medical Center Building Address 1:1 VA Ctr.
Sample Set Name:1 Building Address 2:
City, State Zip:Augusta, ME 04330
Lead Paint
Bldg. 300
Floor 01
308 Base Cove & Mastic
4LG 4" Light Gray
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Bldg. 300
Floor 01
310 12x12 Floor Tile & Mastic
DBRM Dark Brown Marbled
M ND 0 NA
Notes: Located in various areas throughout the building.
NNon-Friable
Page 5 of 5Monday, August 14, 2023
10:06:34 PM
American Engineering Testing, Inc.
Table 2
Togus VA Medical Center Augusta, ME
AET Project No. P-0019594
Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result
54 69 1 102 NE Closet North Wall Plaster White 17.60 228 SF Positive 55 69 1 102 North Wall Plaster Lt. Blue 1.30 64 SF Positive 56 69 1 102 West Door Frame Wood White 36.30 18 SF Positive
Please note that this report is to be used in conjunction with the prior report titled General Asbestos/Lead Containing Paint Summary Report dated March 25, 2011 prepared by Mabbett & Associates, Inc. AET did not test all painted surfaces. Many surfaces appeared to be the same paints identified in the prior report and this report only reflects the materials tested by AET.
Summary of Lead Containing Paints/Coatings
Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: March 20-21, 2023
Table 3
Augusta, ME
AET Project No. P-0011150
Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result
1 Calibration Range <0.01 SRM 2570 0.00 NA Pass 2 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 3 Calibration 3.58 ± 0.39 SRM 2571 3.40 NA Pass 4 221 1 100B East Wall Sheetrock Tan 0.00 NA Negative 5 221 1 100B South Door Frame Metal Tan 0.00 NA Negative 6 221 1 100B South Door Wood Blonde 0.00 NA Negative 7 221 1 100B North Panel Wood Black 0.00 NA Negative 8 221 1 100B South Door Frame Metal Lt. Yellow 0.00 NA Negative 9 221 1 100B South Door Frame Metal Lt. Blue 0.00 NA Negative
10 207 1 132A West Wall Sheetrock Green 0.00 NA Negative 11 207 1 132A North Wall Sheetrock Blue 0.00 NA Negative 12 207 2 201 East Wall Sheetrock Cream 0.00 NA Negative 13 207 3 145/301 East Wall Sheetrock Tan 0.00 NA Negative 14 207 3 145/301 South Panel Wood Black 0.00 NA Negative 15 207 3 307 South Window Frame Metal Gray 0.00 NA Negative 16 207 3 307 West Wall Sheetrock Gray 0.00 NA Negative 17 232 2 202 West Door Wood Blonde 0.00 NA Negative 18 232 2 202 West Door Frame Metal Beige 0.00 NA Negative 19 232 2 202 South Wall Sheetrock Beige 0.00 NA Negative 20 232 2 202 Floor Floor Wood Gray 0.00 NA Negative 21 206 1 145A North Door Frame Metal Gray 0.00 NA Negative 22 206 1 145A West Wall Sheetrock Tan 0.00 NA Negative 23 206 1 145A South Wall Sheetrock Lt. Blue 0.00 NA Negative 24 206 2 213 East Wall Sheetrock Tan 0.60 NA Negative 25 206 2 215 East Wall Sheetrock Lt. Tan 0.00 NA Negative 26 206 3 320 East Wall Sheetrock Tan 0.00 NA Negative 27 206 3 366 North Wall Sheetrock Cream 0.00 NA Negative 28 208 1 117 North Wall Sheetrock Tan 0.00 NA Negative 29 205 1 108 South Wall Sheetrock Tan 0.60 NA Negative 30 205 1 108 East Wall Sheetrock Lt. Green 0.60 NA Negative 31 205 3 307E East Wall Sheetrock Tan 0.00 NA Negative 32 205 3 307E South Wall Sheetrock Lt. Blue 0.00 NA Negative 33 Calibration Range <0.01 SRM 2570 0.00 NA Pass 34 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 35 Calibration 3.58 ± 0.39 SRM 2571 3.50 NA Pass 36 200 G C009 South Wall Sheetrock Yellow 0.00 NA Negative 37 200 G C009 West Wall Concrete Yellow 0.00 NA Negative
Summary of Non-Lead Containing Paints/Coatings
Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: June 20-21, 2023
Shot Building Fl. Rm. Side/Location Component Substrate Color Reading (mg/cm2) Quantity Result
Project: GDM - Togus VA Medical Center By: Bruce A. Boehm Carlson Project No.: P-0019594 Date: June 20-21, 2023
38 200 G C009 South Door Frame Metal Lt. Yellow 0.00 NA Negative 39 200 G C009 South Door Frame Metal Gray 0.00 NA Negative 40 200 G C009 South Door Wood Blonde 0.00 NA Negative 41 200 G 28 South Wall Sheetrock Cream 0.00 NA Negative 42 200 3 E341 West Wall Sheetrock Tan 0.00 NA Negative 43 200 3 E341 East Wall Sheetrock Lt. Blue 0.00 NA Negative 44 200 5 560 Floor Floor Ceramic Tile 1" Green/White 0.00 NA Negative 45 200 5 C501 South Wall Ceramic Tile 4" Gray 0.00 NA Negative 46 200 5 C501 South Wall Ceramic Tile 4" White 0.00 NA Negative 47 Calibration Range <0.01 SRM 2570 0.00 NA Pass 48 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 49 Calibration 3.58 ± 0.39 SRM 2571 4.00 NA Pass 50 Calibration Range <0.01 SRM 2570 0.00 NA Pass 51 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 52 Calibration 3.58 ± 0.39 SRM 2571 3.60 NA Pass 53 69 1 Linen Closet West Panel Wood White 0.00 NA Negative 57 69 1 102 West Door Wood Blonde 0.01 NA Negative 58 211 1 101 East Panel Wood White 0.00 NA Negative 59 211 1 101 West Door Frame Metal Lt. Gray 0.00 NA Negative 60 211 1 101 West Door Wood Blonde 0.00 NA Negative 61 211 1 101 North Wall Brick White 0.02 NA Negative 62 212 1 100 South Wall Concrete Gray 0.00 NA Negative 63 212 1 100 Floor Floor Concrete White 0.05 NA Negative 64 Calibration Range <0.01 SRM 2570 0.00 NA Pass 65 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 66 Calibration 3.58 ± 0.39 SRM 2571 3.60 NA Pass 67 204 2 200 North Wall Plaster Tan 0.00 NA Negative 68 204 2 200 North Wall Ceramic Tile 4" White 0.13 NA Negative 69 Calibration Range <0.01 SRM 2570 0.00 NA Pass 70 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 71 Calibration 3.58 ± 0.39 SRM 2571 3.30 NA Pass 72 255 1 106 West Door Wood Blonde 0.00 NA Negative 73 255 1 106 West Door Frame Metal Brown 0.00 NA Negative 74 255 1 106 South Wall Sheetrock Tan 0.00 NA Negative 75 Calibration Range <0.01 SRM 2570 0.00 NA Pass 76 Calibration 0.71 ± 0.08 SRM 2574 0.70 NA Pass 77 Calibration 3.58 ± 0.39 SRM 2571 3.20 NA Pass
Please note that this report is to be used in conjunction with the prior report titled General Asbestos/Lead Containing Paint Summary Report dated March 25, 2011 prepared by Mabbett & Associates, Inc. AET did not test all painted surfaces. Many surfaces appeared to be the same paints identified in the prior report and this report only reflects the materials tested by AET.
Figures
CRAWL SPACE
BIO-MED
BIO-MED SHOP
TOILET
CHIEF
35 OFFICE
33 CORRIDOR
STAIR
BIO-MED
SPACE
31A
CONF RM
BIO-MED
COMM
ELEV 3
EMS STOR
WHEELCHAIR
REPAIR SHOP
UNIVERSAL
HAZARDOUS
WASTE STOR
149J
CORRIDOR
MECH
MEN LOCKER
149I
MECH
ELEV 2
ELEV 1
WATER PUMP
WOMEN LOCKER
STOR
EMS OFFICE
ROOM
C8A
CORRIDOR
C72
SERVICE LOBBY
C8
PROVIDER OFFICE
C25
CG
STAIR
PROVIDER OFFICE
C23
CG
UP
13-02
CABLING IN CORRIDORS
CORRIDOR
C71
ROOM
C3 ELEV LOBBY
C70
CG
COMM
C6
MEN
C1
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
STAIR
E80
ROOM
E79
ROOM
E19A
ROOM
E17 ROOM
E13E
CORRIDOR
E74
ROOM
E13F
ROOM
E13G
ELEC
E15
ROOM
E11
TR #7B
E13I
OFFICE
E13H
CONF / BREAK RM
E20 OFFICE
E22
ROOM
E13D
ROOM
AGENT CASHIER
E24
ROOM
ROOM
PHARMACY
E19
ROOM
E13C
ROOM
E13
ROOM
E13B
ROOM
E19B
ROOM
E4A
ROOM
E6
ROOM
E4
ROOM
E4B
CORRIDOR
E71
VEST
E70A
PHARMACY
E002A
ROOM
E13A
ROOM
E09
CORRIDOR
E70
ROOM
E12
ROOM
E8
ROOM
E8A
ROOM
E10H
ROOM
E10B
ROOM
E10F
ROOM
E10G
ROOM
E41 ROOM
E52
ROOM
E54
ROOM
391E72
EXAM
E56
EXAM
E55
ROOM
E10
ROOM
E10A
ROOM
E10I
ROOM
E10D
ROOM
13-03
TR CONSTRUCTION200-AE-300
ROOM
E16
ROOM
E14
WOMEN
C4
OFFICE
C17
OFFICE
E23A
OFFICE/EXAM
E23
HAC
C2
OFF PHYS TX
E21
FLOW RM
C13
CG
OFFICE
C15
OFFICE
C14
PHARMACY
C35
EXAM
C34
EXAM
C49
ELEV
ELEV
ELEV
STAFF TOILET
C19
PROVIDER OFFICE
C21
CG
CG
CORRIDOR
CORRIDOR
MAIL RM
ELECTRONICS
TECH
MAIL RM
4A
HAC
C24
PROVIDER OFFICE
C22
CG
CG
PROVIDER OFFICE
C20
DR OFFICE
C37
DR OFFICE
C39
HAC STOR
EMS STOR
LAB STOR
IT STOR
ELEV LOBBY
FMS
STARBUCKS
1 PROSTHETIC STOR
HAC
STAIR
76 TR #7A
C009A
ELECTRONIC
STOR
C009
CORRIDOR
PROSTHETIC STOR
3A
TR CONSTRUCTION
13-03
200-AE-300
CORRIDOR
200209
LOGISTICS
STOR
16C
TOILET
149E
NURSING SUPPLY
C40 TELEHEALTH
C38
ROOM
C55A
ED DIRECTOR
C55
VENDING ACCESS
16F
VENDING
BIO-MED SHOP
16B
SMOKING AREA
16E
EMERGENCY
ELECTRICAL RM
C54A
EXAM
C53
EXAM
C36
ED NURSE
MANAGER
C56
ROOM
C54
EXAM
C51
CG
CORRIDOR
C74
CORRIDOR
149F
CORRIDOR
C76
EXAM
C50
EXAM
C48
OFFICE/EXAM
C12
CG
TOILET
E27A
OFFICE
E25
OFFICE
C11
OFFICE/EXAM
C10
CORRIDOR
E76
IPC TEAM
E28
ELEC
E26
ROOM
E31
ROOM
E34
ROOM
E36
ROOM
E10J
ROOM
E1
ROOM
E33
ROOM
E44
TOILET
E46
TOILET
E48
ROOM
E50A
ROOM
E50
ROOM
E39
CORRIDOR
E77
BIOPSY ROOM
C31 OFFICE
C30
ROOM
C30A
EXAM
LOCKER
E27
STOR
CO45A
ROOM
E42
AMBULANCE BAY
E43
UP
STAIR
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
STAFF ON-CALL
C46A
STOR
C46B
ROOM
E78 ROOM
E45
LIFE SUPPORT RM
E47
EXAM
E49
ROOM
E53
MEDS
E51
TOILET
TREATMENT
E53A
DERMATOLOGY
C33
DERM EXAM
C32
EXAM
C45
STAFF
C46
ROOM
C46B1
OFFICE
C52
ELEC
57A
C G
C G C
G
C G
C G
36, 38, 39, 40
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 200/200E - Ground Level
Figure 2
APPROXIMATE SCALE IN FEET
200 40
N
File: Togus_Bldg200_200E.dwg Ground PO 17938-1911
Legend
Asbestos Sample Location
Positive Material
###-XXX-X
## Lead Test Location
CRAWL SPACE
STAIR
COMP GAS
S 174TOR
O2 STOR
CORRIDOR
STOR
STOR
TOILET
166A
BLUE RM LAB
HISTOLOGY STOR
TRASH UNIT
HAC
166B
02 STOR
159A
HISTOLOGY
157A
HISTOLOGY LAB
COOLER
166C
STOR
166D
ELEC EQUIP
ROOM
OFFICE
155C ULTRA SOUND
CORRIDOR
STOR
FIRE ALARM
162A
CLOSET
ULTRA SOUND
DATA
155A
CHANGING RM
M110
WAITING
M107
OFFICE
M105
TOILET
M108
RECEPTION
M101
TOILET
M106
OFFICE
M104
ELEC
M103
CORRIDOR
M100
COMM
CONTROL RM
145A
TOILET
RECOVERY
M120
HAC
M119
EMS STOR
M18
SUPPLY
M117
COMPUTER RM
M116
ELEV 3
OFFICE / READING
RM
LINEN
READING
HAC
ELEC
149UUU
CORRIDOR
X-RAY 5
PREP
X-RAY 4
149YYY
149VVV
TOILET
141A
X-RAY 3
149WWW
ROOM
LIGHT RM
137A
DARK RM
X-RAY 2
ALCOVE
129B
X-RAY 1
ALCOVE
129A
STRECHER WC
WAITING
CT CONTROL RM
CT SCANNER
CT SCAN ELEC RM
102AELEC
C101A
13-02
CABLING IN CORRIDORS
STAIR
C80
DN
UP CORRIDOR
C120
RADIOLOGY MGR
OFFICE
C102
BONE
DENSITOMETRY
C101
BONE
DENSITOMETRY
C101B
ELEV
ELEV
ELEV
WAITING
149X RECEPTION
149Y CG
EXAM / MEDICINE /
ONCOLOGY /
GASTRO
149AAA
OFFICE
C104A
ELEV LOBBY
C120
OFFICE
C104
CG
BARIATRIC TOILET
149CC
TELE
C103
WOMEN
C105
CONF RM
C106
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
STAIR 3
149TTT
CLINICAL
TEACHING COORD
OFFICE
E107A
TOILET
E105G
OFFICE
E107 HAC
E105F PROCEDURE RM
E108
CORRIDOR
E150
HAC
E103
ELEC
E101
PROCEDURE RM
E114
SPD STOR
E121
CHEIF OFFICE
E107B
ROOM
E105I
VAULT
E105H
PHARMACY
E105
INPT PHARMACY
MGR OFFICE
E105E
ELEC / TELE
105B
LAB
E105A
ELEC
E105B
LAB
E105C
LAB
E105D
PROCEDURE RM
E111
CONTROL RM
E110
SPD CLEAN AREA
E132
ROOM
E144C
BREAK
E105J
OFFICE
E107C
PROCEDURE RM
E109 CORRIDOR
E153
OFFICE
E113
SOILED
E115
TOILET
E112
RECEPTION
E116
NUCLEAR
MEDICINE WAITING
E127
GEN SERGERY
WAITING
E126
ADMIN OFFICE
E125C
READING
E119
LAB
E118
PROCEDURE RM
E117
CORRIDOR
E151
CLEAN UTILITY
E125D
TOILET
E124
DIRTY UTIL
E125
GEN SURGERY
E125B
HAC
E132A
ROOM
E132B
ETD GAS
E144D
DW2
DECONTAMINATION
AREA
DE-IONIZED
WATER
TREATMENT
E142C
PROCESSING
STOR
E144A
ELEC
E144B
GEN SURGERY
E125A
OFFICE
E130A
OFFICE
E120
TR #8B
E122
TR CONSTRUCTION
13-03
200-AE-301
HAC
C109
CORRIDOR
C120
OFFICE
E123
EXAM
E128
SPS ASST CHIEF
E130
SPS CHIEF
E130B
EQUIP
DISPERSING
E136
ELEC
E134
DIST STERILE /
CLEAN SUPPLIES
E138
OFFICE
E138B
TOILET
E140
TOILET
HAC
E142A
VEST
E142D
E142B1
DECONTAM
LOCKER
E142B
LOCKER
E141A TOILET
E141A1
MEN
C107
PHARMACY
E131
EXAM
E133
TRAVEL OFFICE
E133A
STAFF LOUNGE
149EE
CUBICLE
149BBB
CUBICLE
149CCC
CUBICLE
149FF
CUBICLE
149DDD
TOILET
149DD
STAFF TOILET
149VV
CORRIDOR
149BB
OFFICE
149GG
CG 1A3
CONF /
MULTI-PURPOSE
149HH 6
CG CG
CORRIDOR
E152
MEN LOCKER
E138A
ROOM
E140A
DN
UP
STAFF BREAK /
WOMEN LOCKER
E141
STAIR-2
E81
TELEMEDICINE
149UU
CORRIDOR
149Z
CG
1 1
EXAM / MEDICINE /
ONCOLOGY /
GASTRO
149ZZ
NURSE STATION
INTAKE /EXIT
INTERVIE
149W
EXAM
CORRIDOR
TOILET
EXAM
RECEPTION
REVERSE
PRECAUTION RM
149V
TOILET / EXAM
ROOM
149T
PATIENT TOILET
149U
CONSULTATION
RM
CG
149S SOILED UTILITY
149R
ONC:
1 1
INTERVIEW RM -
RHEUMATOLOGY
149YY
STRETCHER /
WHEELCHAIR
ALCOVE
149AA
ELEC
149WW
TELEDATA
149XX
SPS CLEAN STOR
149QQ
HAC
149TT
WASTE VACUUM
PUMP
149RR
1 1A
CG4
CORRIDOR
149SSS
CLEAN LINEN
STOR
149SS
ELEC
149JJ
CRASH CART
149KK
TREATMENT
149FFF
TOILET
149LL
TOILET
149MM
1A3
TREATMENT
149KKK
MED.
149OO
NOURISH.
149EEE
CG
ONC: ONC:
CHEMOTHERAPY
TREATMENT BAY
149PP
CHEMOTHERAPY
TREATMENT BAY
149LLL
CG
ONC:
CHEMOTHERAPY
TREATMENT BAY
149MMM
ONC:
CHEMOTHERAPY
TREATMENT BAY
149NNN
CG CG
NURSE STATION
149NN
CG
1 INTERVIEW ROOM
- ONCOLOGY
149II
CHEMOTHERAPY
TREATMENT BAY
149GGG
ONC:
CHEMOTHERAPY
TREATMENT BAY
149HHH
ONC:
CHEMOTHERAPY
TREATMENT BAY
149III
ONC:
CHEMOTHERAPY
TREATMENT BAY
149JJJ
ONC:
CHEMOTHERAPY
TREATMENT BAY
149RRR
ONC:
CHEMOTHERAPY
TREATMENT BAY
149QQQ
ONCG:C CG
CGCHEMOTHERAPY
TREATMENT BAY
149PPPCG
CG
ONC:CG
CHEMOTHERAPY
TREATMENT BAY
149OOO
CG CG
TOILET GENERAL
PROCEDURE
OFFICE
OFFICE
EXAM
OFFICE
STAIR-C
MECH
OFFICE
RECEPTION
ELEV 2
ELEV 1
ELEV LOBBY
STAIR-E
CORRIDOR
M115 VEST
175A
STOR
MECH SHOP
WAITING
M109
CHANGING RM
M113
WAITING
M112
TOILET
M111
MRI SCAN
M114
LOCKER
155B
CORRIDOR
142A CLEAN SUPPLY
142C
ELEC
TOILET
142B
ROOM
155D ULTRASOUND
SUITE
ROOM
STAIR
SOILED LINEN
CHUTE
156A
MECH
CORRIDOR
EMS STOR
EMS STOR
101A
LOCKER -
RADIOLOGY
STAFF
CAST / EXAM
SUPPLY
STOR
STOR
TELE
152 NO2 STOR
CLOSET
200-AE-301
O2 STOR
O2 STOR
STOR
13-01
TR CONSTRUCTION; DIRECT
ACCESS FROM EXTERIOR
TR #8A
196A
VEST
176A
STAIR
176 BREAK
MEN
CORRIDOR
EXAM
PROCEDURE RM
GENERAL
149Q
EXAM
EXAM
EXAM
EXAM
ELEC
PHYS ADMIN
OFFICE
EXAM
EMERGENCY
GENERATOR
C G
C G
C C
G G
C G
C
G
C G
C G C G
C G C
G
C G
C
G
C G
C G
1 1A
C G
C G C
G C
G
C G
C G
C G
C G
302-SM-A, B, C
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 200/200E - Level 1
Figure 3
APPROXIMATE SCALE IN FEET
200 40
N
File: Togus_Bldg200_200E.dwg Level 1 PO 17938-1911
Legend
Asbestos Sample Location
Positive Material
STOR
270E
STOR
270E1
LAB
270A
CHEMISTRY LAB
LAB
270B
OFFICE
270D
STAIR-D
TOILET
BLOOD BANK
OFFICE
270C
VEST
270F
KITCHEN
264A
OFFICE
265A HEMATOLOGY LAB
ELEC
307 BIO SAFETY
264 264B 264B
BLOOD DONOR RM
OFFICE
262A
OFFICE
CORRIDOR
ROOM
248A
CONF RM
CHUTE
VASCULAR EXAM
RM
VASCULAR STOR
VASCULAR EXAM
RM
TOILET
ELEC
ELEC
230A
PROCEDURE
TOILET
PRE-EQUIP
CLEANING
280B
OFFICE
EXAM
EXAM
BREAK
ELEC
280A
CORRIDOR
PROCEDURE
STOR
EXAM
EXAM
EXAM
ROOM
232A
EXAM
EXAM
EXAM
OPEN OFFICE
ROOM
232B
ROOM
WAITING
CABLING IN CORRIDORS
13-02
ELEC
C201A
PHLEMOTOMY
C202
STAIR-1
DN
UP
BLOOD DRAW /
LAB WORK WAIT
C201
CG CG 1
ELEV
ELEV
ELEV
STRETCHER
ALCOVE
WAITING
RECEPTION /
CHECK-IN
STAIR-C
EXAM
HAC
TOILET
SYPPLY
WAITING
ELEV 3
ELEV 2
ELEV 1
ELEV LOBBY
STAIR-E
STAFF TOILET
208B
PATIENT TOILET
STAFF
HAC
CORRIDOR
TOILET
201A
ROOM
201B
ROOM
201C
ROOM
201D
LAB
CONSULT, INTAKE
/ EXIT INTERVIEW
RM
CORRIDOR
MECH
OFFICE
201E
WAITING
282A
CONSULT RM
CG
TOILET PREP /
RECOVERY RM
10 3
CG9 1
BARIATRIC TOILET
CONF RM
C204
OFFICE
C208
13-03
TR CONSTRUCTION
STAIR
CORRIDOR
E270
SOUND BOOTH
E215
SOILED UTILITY
E211
MICROSCOPE RM
E213
CONTROL BOOTH
E217
ELEC
E209
PRE OP
E202
VISUAL FIELD RM
E204
MECH
E219
SOUND BOOTH
CONTROL BOOTH
CORRIDOR
E275
200-AE-302
AUDIOLOGY
OFFICE
C212
AUDIOLOGY EXAM
C210
CORRIDOR
C206
TELE
C203
WOMEN
C205
MEN
C207
HAC
C209
CORRIDOR
E272
EXAM
E203
SUPPLY
E204A
EXAM
E206
TR #9B
E201
PT EXAM
E240
EUDIOLOGY STOR
E241
EXAM
E205
AUDIO TECH
OFFICE
E242
EXAM
E220
EXAM
E222
ROOM
E229
EXAM
E228
EXAM
E226 WAITING
E207
TOILET
E224
CORRIDOR
E273 CORRIDOR
WOMEN
E221 HYDROTHERAPY
E236B
OFFICE
E236C
TOILET
E236D
EXAM
E251C
CONTROL BOOTH
E246B
SOUND BOOTH
E246C
HEALTH SYSTEM
SPECIALIST
C243
CHIEF AUDIOLOGY
C243A
PHYSIOLOGY LAB /
PULMONARY
EXERCISE
CG CG1
CG
CG
CG
CORRIDOR
E271
AUDIOLOGY EXAM
E245
HAC
E247
AUDIOLOGY
E249
EXAM
E239
CG DN
UP
ELEC
E248
AUDIOLOGIST
E252
STOR
E250
CORRIDOR
E274
EXAM
E251
STOR
E251A
STAFF
E251B
MECH
E254
EXAM
E223A EXAM
E218
EXAM
E216
EXAM
E214
EXAM
E212
MINOR SURGERY
OPHTHALMOLOGY
E223
CHEIF OT OFFICE
E225
CORRIDOR
E276
OFFICE
E227A
OFFICE
E227B
TECH OFFICE
E227C ADL KITCHEN
E234A
TOILET
E233
EXAM
E212A
ELEC
E232
WAITING
E231 OFFICE /
RECEPTION
E236A
PHYS THERAPY
CLINIC
E236
AUDIOLOGIST
E255
STAIR-2
E081
CGAPNEA RM
CG CG
PHYSIOLOGY LAB /
PULMONARY
EXERCISE
INTERVIEW
CG
1A 5 CG
CORRIDOR
CONSULT / APNEA
RM
CG
4CG CG
1A3 10 1 1
MECH
HAC
MED GAS
TOILET
CONSULT RM
CONSULT RM
CONSULT RM
1 1
CORRIDOR
ELEV LOBBY
C220
CG
CG
CORRIDOR
CG
ELEC
INTERVIEW -
ENDO.
TELEDATA
NOURISH.
RECEPTION
STOR
205A
PROCEDURE RM,
BRONCHOSCOPY
PREP / RECOVERY
CG CG
CRASH CART
1A
CG CG
CG CG
CORRIDOR
CG
NURSE STATION
CLEAN LINEN
STOR
MEDICATION AREA
1 8CG CG
CG 1 1 1 2
SPS CLEAN STOR
CG
EQUIP / STOR
STAFF LOUNGE
CORRIDOR
OFFICE, DIRECTOR
OF RESPIRATORY
THERAPY
CLOSET
CUBICLES - 5
TOTAL
CG
CG
CG
CUBICLE, CHIEF
OF PULMONARY
MEDICINE
CG
1A
SOILED UTILITY
STAFF TOILET
3 10
CUBICLE, STAFF
PHYSICIAN -
INFECT
ELEC
CUBICLE, STAFF
PHYSICIAN -
ENDOC.
CUBICLES - 4
TOTAL
CG
ROOM
208A
STAIR-F
ELEC
CORRIDOR
EXAM
EXAM
SD
CLEAN LINEN
TR #9A
EXAM
BATH / SHOWER
214 DIRTY LINEN
TELE HEALTH
STAFF
HAC
TELE
LAB MGR OFFICE
MECH
208D
13-03 TR CONSTRUCTION
STAFF
208C
200-AE-302
PATHOLOGY LAB
OFFICE
OFFICE
262B
STOR
OT CLINIC
E234
EXAM
E238A
CORRIDOR
E238
OT OFFICE
E234B
TREATMENT
E238B
STOR
E234C
OFFICE
E234D
STOR
E238D
OFFICE
E238C
C
G
C G
C G
C G
C G
1A
1A C
G
1A
C G
C
G
C
G
C G
C G
1A
C G
C G
302-PHBW-A, B, C
313-BRBP-A, B, C
308-4BR-A, B, C
305-WL-A, B, C
310-LGGS-A, B, C
308-4M-A, B, C
File: Togus_Bldg200_200E.dwg Level 2 PO 17938-1911
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 200/200E - Level 2
Figure 4
APPROXIMATE SCALE IN FEET
200 40
N
Legend
Asbestos Sample Location
Positive Material
STAIR-D
HAC
372A
ROOM
SUPPLY
BREAK
CLEAN LINEN
385A MULTI-PURPOSE
PROCEDURE
PROCEDURE RM
TOILET
MED STORE
KITCHEN
ROOM
358A
ROOM
358B
NURSE STA
OFFICE
BED
358K
200-AE-303
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
TOILET
EXAM
ROOM
358C
EXAM
OFFICE
13-04
TR CONSTRUCTION
EXAM
PATIENT RM
TOILET
336A
EXAM
AIR HANDLER RM
334A
ELEC
ROOM
TOILET
PATIENT RM
PATIENT RM
TOILET
344A
MECH
NURSE STA
TOILET
3445A
PATIENT RM
PATIENT RM
376 TOILET
343A
HAC
TOILET
339A
PATIENT RM
NURSE STA
PATIENT RM
TOILET
340A PATIENT RM
MED CART STOR
342A
MED RM
338A
MED RM
CORRIDOR
CLEAN LINEN
TOILET
335A
TOILET
PATIENT RM
SOILED
CLEAN LINEN
329A
SPD STOR
TOILET
ROOM
329B
O2 STOR
CORRIDOR
LOCKER
302A
CLEAN UTILITY
ELEC
C301A
CONF RM
C302
STAIR-1
DN
UP ELEV
ELEV
ELEV
ELEV LOBBY
C301
OFFICE
C304 ELEV LOBBY
C320
NEPHROLOGY
OFFICE
C306
CORRIDOR
C321
NEPHROLOGY
OFFICE
E304
OFFICE
E302
TELE
C303
TOILET
C305
TOILET
C307
HAC
E361
STAIR
HAC
E311
OR STOR
E363
CLASS RM
E365
200-AE-303
13-03
TR CONSTRUCTION
1-BED RM
E310
1-BED RM
E312
ANTE RM
E313
CONSOLATION RM
E328
1-BED RM
E314
SICU
1-BED RM
E315
BREAK
E332
NOURISHMENT
E333
MED RM
E331
SUPPLY
E330
NURSE STA
E306
CLEAN LINEN
E326
ANTE RM
E316
1-BED RM
E317
HAC
E301H
STOR
E318
ELEC
E319
1-BED RM
E320
1-BED RM
E321
1-BED RM
E322
1-BED RM
E323
N MGR OFFICE
E325
TOILET
E324A
LOCKER
E324
SOILED UTILITY
E301E
CLEAN UTILITY
E301F
BREAK
E301G
WATER TANK
E301G1
SOILED UTILITY
E327
LOCKER
E329
TOILET
E329A
DIALYSIS SUITE
E301
SOILED EQUIP
E301D
SUPPLY
E360C
TOILET
E360D
WOMEN LOCKER
E384
SOILED UTILITY
E360E
ELEC
E343
HAC
E386
MEN LOCKER
E382
OR 5
E380
OR 4
E378
HAC
E374
ELEC
E376
CLEAN EQUIP
E301C ROOM
E342
PACU
E360
PRE OP AREA
E362
OFFICE
E362B
LOUNGE /
DICTATING RM
E390A
CLEAN DW
SURGICAL SVC
E390
STOR
E372A
ANEST OFFICE
E369A
STERILIZER AREA
E390B
DIRTY DW
SOILED UTILITY
E373
STOR
1-BED RM
E309
1-BED RM
E308
1-BED RM
E307
ELEC
E305
ISOLATION BED
RM
E303
MEN LOCKER
E301A
WOMEN LOCKER
E301B
TOILET
E301A1
TOILET
E301B1
CORRIDOR
E392
EXAM
E340
TR #10B
E341
TOILET
E362A1
LOCKER
E362A
CLEAN UTILITY
E360A
OR 1
E364
CORRIDOR
E391
ELEC
E366
ROOM
EQUIP
OR 2
E368
O2/CO2
HAC
E370
ROOM
DNSTAIR-2
STOR
E367
OR 3
E372
STOR
E369
CLEAN LINEN
SPD CLOSET
PATIENT RM
TOILET
306A
STAIR-C
MECH
332B
BREAK
332A
PATIENT RM
TOILET
TOILET
PATIENT RM
ELEV 3
ELEV 2
ELEV 1
ELEV LOBBY
TOILET
301A
STAIR-E
PATIENT RM
TOILET
303A
PATIENT RM
MECH
305A
STAIR-F
KITCHEN
CORRIDOR
SOIL
300B
TOILET
308A
PATIENT RM
NURSE STA
OFFICE
310B
WORK AREA
310A
HAC SINK
300C
PATIENT RM
331 TOILET
312A
ELEC
300D
TOILET
316A
PATIENT RM
PATIENT RM
329 TOILET
318A
MEDS
PATIENT RM
HAC
PATIENT RM
ELEC
RECEPTION
AIR HANDLER RM
307A
ROOM
ROOM
358E
ROOM
358D
BED
358G
BED
358H
TR #10A
358J
WAITING
ISO PATIENT RM
TOILET
309A
ANTE RM
13-02
CABLING IN CORRIDORS
TOILET
313A TOILET
317A
PATIENT RM
PATIENT RM
TOILET
319A
STAFF SURGEON
E348
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
CORRIDOR
E345
STAFF SURGEON
E350
SURGERY ADMIN
E349
TREATMENT
E358
ROOM
E347
13-04
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
CHEIF
NEUROSURGERY
E352
STAFF SURGEON
E354 STAFF SURGEON
E356
42 48
File: Togus_Bldg200_200E.dwg Level 3 PO 17938-1911
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 200/200E - Level 3
Figure 5
APPROXIMATE SCALE IN FEET
200 40
N
Legend
Asbestos Sample Location
Positive Material
STAIR-D
MECH
OFFICE
CABLING THROUGHOUT
DEPARTMENT AS INDICATED
13-04
OFFICE
OFFICE
DENTAL OFFICE
CORRIDOR
DENTAL
OFFICE
ELEC
ELEV 3
LAB
DECON RM
DRESSING RM
PROCEDURE RM
PROCEDURE RM
PROCEDURE RM
STAIR-C
TOILET
TOILET
CORRIDOR
TREATMENT
STOR
DRESSING RM
546A
CORRIDOR
DRESSING RM
545A
DRESSING RM
544A
OFFICE
RECOVERY
536A
RECOVERY
536B
RECOVERY
536C
RECOVERY
536D
RECOVERY
536E
RECOVERY
536F VEST
WAITING
TOILET
530A
HAC
528 CORRIDOR
CONFERENCE RM
TOILET
C502
ELEC
C501A
STOR
C501
STAIR-1
CLINICAL
DIETITIAN OFFICE
C504
ELEV LOBBY
C520
OFFICE
OFFICE SUPPLY
C504A
13-03
TR #12
C501B
TR CONSTRUCTION
ELEV
ELEV
ELEV
? 200-AE-304
CHIEF OFFICE
ROOM
535A
NURSE STA
WAITING
ELEV 2
ELEV 1
CORRIDOR
VEST
ELEV LOBBY
STAIR-E
SUPPLY
OPERATORY
503 ORAL SURGERY
OPERATORY
DARK RM
ELEC
CLEAN LINEN /
SUPPLY
PATIENT TOILET
SOILED UTILITY
SOILED LINEN
HAC
PANOGRAPHY
OPERATORY
OPERATORY
OPERATORY
SUPPLY
CORRIDOR
RESIDENT
OPERATORY
RESIDENT
OPERATORY
DENTAL LAB
STAIR-F
RESIDENT
MEDS
OPERATORY
OPERATORY
RESIDENT
OPERATORY
525 STOR
527A
VEST
TELE
OFFICE
WOMEN LOCKER
517C
CONF / BREAK RM
517A
STAFF TOILET
517B
MEN LOCKER
517D CABLING IN CORRIDORS
13-02
OFFICE
LEVEL 5 FLOOR PLAN
45, 46
315-1GW-A, B, C
315-4G-A, B, C
File: Togus_Bldg200_200E.dwg Level 5 PO 17938-1911
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 200/200E - Levels 5, 6, 7
Figure 6
APPROXIMATE SCALE IN FEET
200 40
N
Legend
Asbestos Sample Location
Positive Material
STAIR
FREEZER
220C #3
COOLER
220F #4
COOLER
220D #5 ELEV
ROOM
ROOM
COOLER
220E #6
ROOM
FREEZER
220B #2
FREEZER
220A #1
13-03
CABLING
KITCHEN
FREEZER
217A
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
215A
ROOM
TH
RE
TR #19
200A
ROOM
204A
ROOM
DINING
ROOM
ROOM
ROOM
STOR
STAIR
ROOM
ROOM
13-02
CABLING
LEVEL 2
ROOM
220A
ROOM
ROOM
ROOM
13-03
TR CONSTRUCTION
ROOM
ROOM
205A
67, 68 315-4W-A, B, C
Togus VA Medical Center 1 VA Ctr.
Augusta, ME, 04330 AET Project No. P-0019594Date: 8/15/2023
Sample Locations Building 204
Figure 7
APPROXIMATE SCALE IN FEET
100 20
N
File: Togus_Bldg204.dwg 204 PO 17938-1911
Legend
Asbestos Sample Location
Positive Material
OFFICE
300F
OFFICE
318B
OFFICE
318A
OFFICE
EXAM
316B
EXAM
316C
EXAM
314A
OFFICE
312A
ROOM
316A ROOM
316D
CORR
STOR
STAIR
OFFICE
OFFICE
PURCHASING
OFFICE
313A
OFFICE
311A
ROOM
307B
ROOM
307A
ROOM
307D
TR #22
307E
ROOM
307C
ROOM
ROOM
ROOM
SUPPLY
OFFICE
312B
OFFICE
300E
ROOM
TOILET
ELEC
OFFICE
300B
ROOM
OFFICE
300G
OFFICE
300H
OFFICE
300I
OFFICE
300K
OFFICE
300L
LAB
300M
OFFICE
300D
OFFICE
300C
STOR
300A
STAIR
CORR
MULTI-PURPOSE
MULTI-PURPOSE
332A
MULTI-PURPOSE
ELEV
PSYCH SERVICES
OFFICE
337J
OBSERVATION
300N
CONF
CHASE
MEN
ELEC
OFFICE
337I
CORR
COMP
336A
OFFICE
336B
OFFICE
336C
DISTRICT COUNCIL
OFFICE
336D
LEVEL 3
LIBRARY
336E
ROOM
336F
STAIR
CLOSET
OFFICE
337H
SOCIAL WORK
SERVICES
OFFICE
337G
OFFICE
337A
OFFICE
337B
OFFICE
337C
OFFICE
337D
OFFICE
337E
OFFICE
337F
ROOM
100A
ROOM
ROOM
116A ROOM
ROOM
ROOM
118A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .