This document is a product specification sheet for a Mitsubishi Electric Trane HVAC indoor unit model TCMBG0104SJ11N4, a 4-branch single BC (branch controller) system with a capacity of 54,000 BTU/H per branch connectable to outdoor units ranging from 72,000 to 120,000 BTU/H total capacity. The unit operates on 208/230V, single-phase, 60 Hz electrical power with a minimum circuit ampacity of 0.4/0.4 amps and maximum overcurrent protection of 20 amps, drawing 0.30-0.35 kW during cooling and heating modes. External dimensions are 9-7/8 x 23-1/2 x 15-11/16 inches (250 x 596 x 398 mm) with a net weight of 58 pounds (26 kg), featuring a galvanized steel plate exterior with a pre-coated galvanized and powder-coated lower drain pan.
The unit uses R410A refrigerant exclusively and includes a 3/4 NPT field drain pipe connection. Sound specifications indicate a sound power level of 40 dB(A) during defrost and 59.0 dB(A) during rated cooling operation, with sound pressure levels of 71 dB(A) during defrost measured in an anechoic chamber at approximately 5 feet from the unit. The specification sheet includes detailed dimensional drawings showing mounting configurations, service space requirements, connection points for high and low pressure refrigerant lines, and liquid/gas piping connections for indoor units. A comprehensive accessories list is provided, including ball valves, condensate pumps (Blue Diamond Advanced and MicroBlue models), M-Net control wiring, and various branch joints and reducers with different downstream capacity ratings ranging from 72,000 to 360,000 BTU/H to accommodate system configurations.
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Job Name:
System Reference: Date:
Specifications System Unit Type TCMBG0104SJ11N4
Indoor Unit Capacity Connectable to 1 Branch BTU/H 54,000 Number Of Branches 4 Electrical Power Requirements 208/230V, 1-phase, 60 Hz Minimum Circuit Ampacity (MCA) A 0.4/0.4 Maximum Overcurrent Protection (MOCP) A 20 Power Input (208 / 230V) Cooling kW 0.30 / 0.35 Power Input (208/230V) Heating kW 0.30 / 0.35/
Current Input (208/230V) Cooling A 0.061 / 0.078/ Heating A 0.030 / 0.039
External Dimensions In. [mm] 9-7/8 x 23-1/2 x 15-11/16 [250 x 596 x 398] Net Weight Lbs. [kg] 58 [26]
External finish Galvanized steel plate (Lower part drain pan: Pre-coated galvanized sheets + powder coating) ()
Connectable Outdoor / Heat Source Unit Capacity 72,000 to 120,000 Field drain pipe size In. [mm] 3/4 NPT Refrigerant R410A Sound power level (measured in anechoic room) Defrost dB(A) 40
Sound pressure level (measured in anechoic room) Rated operation dB(A) 59.0 Defrost dB(A) 71
NOTES:
1. The equipment is for use with R410A refrigerant only.
2. When possible, avoid installing the BC controller within 15 Ft. of sound sensitive areas.
3. Rated operation sound data is based on cooling mode. Sound data may vary depending on outdoor unit capacity and operation mode.
4. Sound pressure/power levels obtained via testing in an anechoic chamber. Actual sound pressure levels may be greater due to ambient noise and/or deflection
5. Sound pressure values were obtained at a test location approximately 5 Ft. from the unit
6. The solenoid valve switching sound pressure value is 56 dB(A) for all units
7. The unit is intended for installation in an indoor environment only
8. For details regarding installation specifics, please refer to the product’s Installation Manual.
TCMBG0104SJ11N4
4 BRANCH (SINGLE BC)
Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
INDOOR UNIT ACCESSORIES: TCMBG0104SJ11N4
Ball Valve Ball Valve (3/8” SAE Brazed) BV38BBSI Ball Valve (5/8” SAE Brazed) BV58BBSI
Condensate
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MicroBlue) Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H X86-003 Sauermann Condensate Pump SI30-230
Control Wire M-Net Control Wire, 1,000’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-1000 M-Net Control Wire, 250’ Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) CW162S-250
Port Adapter Joint Pipe Adapter CMY-R160-J1
Valves Adaptors & Headers
Branch Joint (Downstream capacity 127,000-216,000 BTU/H) CMY-R202S-G Branch Joint (Downstream capacity 217,000-234,000 BTU/H) CMY-R203S-G Branch Joint (Downstream capacity 235,000-360,000 BTU/H) CMY-R204S-G Branch Joint (Downstream capacity 73,000-96,000 BTU/H) CMY-Y102LS-G2 Branch Joint (Downstream capacity ≤126,000 BTU/H) CMY-R201S-G Branch Joint (Downstream capacity ≤126,000 BTU/H) CMY-Y202S-G2 Branch Joint (Downstream capacity ≤72,000 BTU/H) CMY-Y102SS-G2 Branch Joint (Downstream capacity ≥316,000 BTU/H) CMY-R205S-G Reducer (Between Main and Sub BC) CMY-R303S-G1 Reducer (Between ODU and BC) CMY-R302S-G1
Specifications are subject to change without notice.� © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
FORM# TCMBG0104SJ11N4 - 202209
TCMB0104, 0106, 0108SJ Unit: mm(in)
78 130
(2
-3 /8
A=
B
(2
-3 /8
A=
B
C on tro l b ox
(Lifting bolt pitch)
(L ift in g bo lt pi tc h)
In do or u ni t m od el
(N ot e 4)
P1 or le ss : ø
6.
(1 /4
Br az ed
P1 ov er
: ø 9.
(3
/8
Br az ed
In do or u ni t m od el
(N ot e 4)
P1 or le ss : ø
.7
(1 /2
Br az ed
P1 ov er
: ø
.8
(5 /8
Br az ed
(4 -1
3/
(5-1/8) (7-7/8)
(4) 267(10-9/16)
(1
(2 -1
1/
(8 -1
3/
(3-1/8) (5-1/8) 398(15-11/16)
323(12-3/4) 35(1-7/16)
(2 3-
1/ 2)
(2 5-
9/
(4 -3
/4
4-
/1
6) (2
-3 /8
11(7/16)
250(9-7/8)
(1
5/
(3
-1 /2
)(2 -3
/8 ø1 9.
(3
/4
N ot e 5) ø2 8.
(1
-3 /1
6) (N ot e
5)
(8 -5
/8
(1 -1
/2
(E m er ge nc y dr ai ni ng
)D et ai l o f X s ec tio n D et ai l o f Y s ec tio n
(In do or un it M od el:
P1
8 o ve
r) (In do or un it M od el:
P or le ss
(1
3/
(2
(9
/1 6)
30(1-3/16) 12(1/2)
A B
CM
B-
P1
NU
-J
(7 -1
/8
CM
B-
P1
NU
-J
(1 1-
/1
6)
CM
B- P1
NU
-J
(1
6- 9/
N ot e 1.
S us pe ns io n bo lt
(ø
) a nd n ut
(M
) p re pa re in th e fie ld
2.
T ak e no tic e of s er vi ce s pa ce a s sh ow n.
(P le as e gi ve a tte nt io n no t t o oc cu py s er vi ce s pa ce b y le tti ng d uc ts an d pi pe s th ro ug h.
3.
In st al l t hi s pr od uc t i n a lo ca tio n w he re n oi se
(r ef rig er an t n oi se em itt ed b y th e un it w ill no t d is tu rb th e ne ig hb or s.
(F or u se in q ui et e nv iro nm en ts w ith lo w b ac kg ro un d no is e, po si tio n th e
BC
C O
N
TR
O
LL
ER
a t l ea st m a w ay fr om a ny in do or u ni ts
4.
R ef er to th e
In st al la tio n
M an ua l f or re fri ge ra nt p ip in g di am et er s iz e w he n co nn ec tin g pl ur al in do or u ni ts w ith b ra nc h.
5.
R ef er to th e Ta bl e-fo r c on ne ct io n pi pe o f o ut do or u ni t d ia m et er si ze
6.
R ef er to th e
In st al la tio n
M an ua l f or in su la tio n of c on ne ct io n pi pe a nd dr ai n pi pi ng
7.
D o no t p la ce th e
BC
c on tro lle r d ire ct ly o n th e flo or
<A cc es so rie s>
Sq ua re w as he r ( w ith c us hi on
4p cs
Sq ua re w as he r•
4p cs
Y
X 3/
N
PT
s cr ew
C on ne ct io n pi pe o f o ut do or u ni t
(H ig h pr es su re
C on ne ct io n pi pe o f o ut do or u ni t
(L ow p re ss ur
e) C on ne ct io n pi pe o f in do or u ni t ( Li qu id
C on ne ct io n pi pe o f in do or u ni t (
G as
3/
N
PT
s cr ew
C ut tin g po in t C ut tin g po in t
C on ne ct ab le un it ca pa ci ty
H ig h pr es s.
P ip e Lo w p re ss
. P ip e ø1 5.
(5
/8 ø1 9.
(3
/4 ø1 9.
(3
/4 ø2 2.
(7
/8 ø1 9.
(3
/4 ø2 2.
(7
/8 ) o r ø
.5
(1 -1
/8
Ta bl e- 1.
T o ou td oo r/h ea t s ou rc e un it (N ot e.
5)
*F or th e re fri ge ra nt p ip e siz e, re fe r t o
In st al la tio n
M an ua l o f o ut do or u ni ts /h ea t s ou rc e un its sp ac e Se rvi cesp ac e Se rvi ce
)052(
(200) 45073
(N ot e 2)Ac ce ss do or
(1 7-
3/ 4)
(17-3/4)
(2 -7
/8 ) (9-7/8)
(700)(27-9/16)
(9 -7
/8
(100)(3-15/16) (7-7/8)
INDOOR UNIT DIMENSIONS: TCMBG0104SJ11N4
| Job Name 11: |
| System Reference 11: |
| Date 11: |
| Check Box 1: Off |
| Check Box 2: Off |
| Check Box 3: Off |
| Check Box 4: Off |
| Check Box 5: Off |
| Check Box 6: Off |
| Check Box 7: Off |
| Check Box 8: Off |
| Check Box 9: Off |
| Check Box 10: Off |
| Check Box 11: Off |
| Check Box 12: Off |
| Check Box 13: Off |
| Check Box 14: Off |
| Check Box 15: Off |
| Check Box 16: Off |
| Check Box 17: Off |
| Check Box 18: Off |
File details come from the government source that posted it. Updated .