MW301 Rev 1.pdf

PDF 640 KB Posted

Attached to
Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
Solicitation number
n44255
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document package includes mechanical engineering drawings and specifications for a federal construction contract opportunity. The project constructs a general purpose berthing pier and trestle with controlled access, vessel maintenance facility with parking, fuel distribution and storage system to support the Maritime Force Protection Unit (MFPU) Bangor's operations mission of providing security escort for submarines through the Strait of Juan de Fuca and test range. Facilities detailed in the drawings include typical pier and trestle trenches housing potable water, sanitary sewer, and oily waste piping with insulation and weather jackets. Isolation valves, conduit, supports, and containment boxes are also specified. The opportunity is solicited by the Department of the Navy Naval Facilities Engineering Command for general contractor services.

View the file

Other files for this federal contract opportunity

Other files attached to Amendment 0010 -Use the applicable Small Business Forms attached, newest first.
File Type Posted
Sections B- F-G forms.pdf PDF
Rev1442.pdf PDF
SB106 Rev 2.pdf PDF
Fueling Site From Sealion Road.jpg JPG image
Fueling Site.jpg JPG image
SB503 Rev 1.pdf PDF
MW102 Rev 1.pdf PDF
EW628 Rev 4.pdf PDF
EW401 Rev 7.pdf PDF
EW623 Rev 2.pdf PDF
EB605 Rev 3.pdf PDF
03 30 00 Rev.pdf PDF
01 45 35 Rev.pdf PDF
08 11 16 Rev.pdf PDF
Answer Attachment.xlsx XLSX spreadsheet
CS101 Rev 1.pdf PDF
MW613 Rev 1.pdf PDF
MW611 Rev 1.pdf PDF
MW112 Rev 1.pdf PDF
MW601 Rev 1.pdf PDF
Amendment 008 changes.docx DOCX document
26 11 13.00 20 Rev.pdf PDF
01 45 00.00 20.pdf PDF
13 34 20 Rev.pdf PDF
Amendment 0008.pdf PDF
1100 kW Generator Photo_0006.pdf PDF
PPI AMEND 0006.pdf PDF
Amendment 0005.pdf PDF
CS102 Rev 1.pdf PDF
EW141 Rev 1.pdf PDF
CS103 Rev 1.pdf PDF
EW124 Rev 1.pdf PDF
P-876 AS-Built_E130.pdf PDF
AB603 Rev 1.pdf PDF
01 32 17.00 20.pdf PDF
AB111 Rev 1.pdf PDF
EW404 Rev 1.pdf PDF
EW602 Rev 1.pdf PDF
EW611 Rev 1.pdf PDF
SF30 Continuation .pdf PDF
Amendment 0004.pdf PDF
Amendment 003.pdf PDF
SF30 Continuation rev.pdf PDF
Amendment 0002 SF30.pdf PDF
Amend_1_Page_2.pdf PDF
P907 Project Location.pdf PDF
SF30 Amendment 0001.pdf PDF
RFP P-907 Pier and Maintence Facility.pdf PDF
RFP Attachment K_EXAMPLE Overhead Forms.xlsx XLSX spreadsheet
Attachment J.pdf PDF
Show all 50

Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8" POTABLE

WATER

3"DW OW (PUMPED)

4"DW SS (PUMPED)

CONCRETE TRENCH

ACCESS LID

DIRTY TRENCH

CLEAN TRENCH 1

CHANNEL

SUPPORT

(SEE SW545)

CL

APPROX. 0'-7"

(TYP FOR PW)

APPROX. 0'-4"

(TYP FOR OW & SS)

ELEC. CONDUIT IN

VARIOUS LOCATIONS.

2"

53"DW OW

(PUMPED)

4"DW SS (PUMPED)

8" POTABLE

WATER

ISOLATION VALVE WITH 2"

SQUARE NUT OPERATOR

CLEAN TRENCH 1

DIRTY TRENCH

CONCRETE TRENCH

ACCESS LID

CHANNEL

SUPPORT

(SEE SW545)

APPROX. 0'-7"

(TYP FOR PW)

APPROX. 0'-4"

(TYP FOR OW & SS)

ELECTRICAL CONDUIT IN

VARIOUS LOCATIONS

4"

8" PW

4" SANITARY SEWER, DOUBLE

WALL (PUMPED)

3" OILY WASTE, DOUBLE

WALL (PUMPED)

ARV-P1

A1

MW503

ARV-P2

A4

MW503

ARV-P3

A4

MW503

8"PW

SEE CW154 FOR CONTINUATION

TRESTLE

ABUTMENT

PAPW-2EJ-6

PAPW-1

A1

MW501

SEAL ANNULAR RING AT PIPE SLEEVE

WITH NON-SHRINK GROUT (TYP 3)

3"OW DW4"SS SW

A1

MW402

C2

MW402

2.5" FLEXIBLE

HOSE TO SUMP

SST DAM

2.5" 316 SST DRAIN PIPING

WELDED TO SST DAM

FLANGED CLEANOUT ON SS

SST CONTAINMENT BOX

3"OW (SW) 4"SS (SW)

3"OW (SW) 4"SS (SW)

SST CONTAINMENT BOX

7 7 telephone: 206.448.1911

2301 Fifth Avenue, Suite 401 www.notkin.com facsimile: 206.448.9485

Seattle, WA 98121

Contact: Peter Sloane, P.E.

notkin#: 217069 mechanical engineers notkin

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

N A

V F

A C

N W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

IL

V E

R D

A L

E W

A S

H

IN

G T

O N

N A

V A

L B

A S

E K

IT

S

A P

-B A

N G

O R

S

IL

V E

R D

A L E

W

A S

H

IN

G T

O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

K. PAULSON

/2 /2

:0

:4

P M

C R e v it P ro je c ts

\P -9

\P

-P

IE

R

-1

-M

E C

H -R d e ta c h e d

.r v t

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

S E

C T

IO

N

S

T Y

P

IC

A L

T P

P P

IE

R

T R

E N

C H

E S

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R T

H W

E S

T

KHRPS LDS

MW301

196 269

16046544

B. GALLOWAY

B. NIXON

SHEET KEYNOTES:

SEE STRUCTURAL SW531 (TRESTLE) AND SW533 (PIER) FOR

EXACT DIMENSIONS.

PROVIDE PIPE GUIDE & SUPPORT CONSISTING OF 1/2"ø HDG

CS U-BOLTS WITH HDG CS DOUBLE NUTS AND

WASHERS(TYPICAL). ATTACH U-BOLTS TO CHANNEL SUPPORT

AND SET 1/8" MIN. GAP BETWEEN U-BOLT AND PIPE.

3" X 2'-2" X 1/2" THICK UHMWPE SLIDE PLATE.

3" X 1'-3" X 1/2" THICK UHMWPE SLIDE PLATE.

PROVIDE 1/2" INSULATION & T316 SST WEATHER JACKET FOR

ALL OW & SS PIPING ON THE PIER AND TRESTLE INCLUDING

ABOVE DECK AND IN TRENCHES, UNLESS INDICATED

OTHERWISE.

PROVIDE 1" INSULATION & T316 SST WEATHER JACKET FOR

ALL PW PIPING ON THE PIER AND TRESTLE INCLUDING ABOVE

DECK AND IN TRENCHES, UNLESS INDICATED OTHERWISE.

PROVIDE EXTENDED VALVE STEM UP THROUGH LID OF

CONTAINMENT BOX WITH REMOVABLE HANDLE FOR 3"OW

(SW) AND 4"SS (SW) FLANGED ISOLATION VALVES. SEAL LID AT

VALVE EXTENSION WITH RUBBER GROMMET.

1.

2.

3.

4.

5.

6.

7.

C3

A3

MW101

MW102

SCALE: 1" = 1'-0"

SECTION - TYPICAL TRESTLE TRENCHES

0' 6" 1' 2'

0' 6" 1' 2'

SCALE: 1" = 1'-0"

SECTION - TYPICAL PIER TRENCHES

SCALE: 1/2" = 1'-0"

SECTION - TPP PIER TRENCH TRANSITION

A1

MW102

0' 1' 2' 4'

SCALE: 1/2" = 1'-0"

SECTION - ABUTMENT

B1

0' 1' 2' 4'

MW101, MW402

C2 MW102, MW301, MW402, MW602

0' 6" 1' 2'

SCALE: 1" = 1'-0"

SECTION - TYPICAL TRENCH PIPE ANCHOR

SCALE: 1" = 1'-0"

SECTION - PIER ISOLATION VALVES

C1 MW102

0' 6" 1' 2'

P

PI

0/

A

JM

Sheets
MW301 - SECTIONS - TYPICAL TPP PIER TRENCHES

File details come from the government source that posted it. Updated .