EW111 Rev 2.pdf

PDF 213 KB Posted

Attached to
Amendment 0010 -Use the applicable Small Business Forms attached
Solicitation number
n44255
Issued by

About this file

This package includes construction plans and specifications for a federal contract solicitation. The project constructs a general purpose berthing pier and trestle with controlled access, vessel maintenance facility with parking, fuel distribution and storage system to support the Maritime Force Protection Unit's operations mission of providing security escort for submarines through protection and defense during transit in the Strait of Juan de Fuca and test range. Facilities include a pier power plan on sheet 1 showing electrical equipment, panels, and conduits, an enlarged plan of the KB dock north on sheet 2, and electrical schedules on sheet 3. The solicitation is issued by the Department of the Navy Naval Facilities Engineering Command for an indefinite delivery indefinite quantity construction contract to provide maintenance and repair services at various facilities.

View the file

Other files

File Type Posted
Sections B- F-G forms.pdf PDF
Rev1442.pdf PDF
SF30 Amendment 0010.pdf PDF
SB106 Rev 2.pdf PDF
EW404 Rev 3.pdf PDF
01 32 17.00 20 Rev.pdf PDF
Attachment K.docx DOCX document
VMF SIte 3 from Sturgeon St.jpg JPG image
EW626 Rev 1.pdf PDF
Answer Attachment.xlsx XLSX spreadsheet
KB Spit 1 - Pier Location.jpg JPG image
MW301 Rev 1.pdf PDF
EW628 Rev 4.pdf PDF
Fueling Site rev.jpg JPG image
MB602 Rev 1.pdf PDF
EW303 Rev 2.pdf PDF
EB603 Rev 1.pdf PDF
08 41 13 Rev.pdf PDF
MW103 Rev 1.pdf PDF
EW623 Rev 2.pdf PDF
MW102 Rev 1.pdf PDF
EB605 Rev 3.pdf PDF
EB606 Rev 2.pdf PDF
MB603 Rev 1.pdf PDF
EB101 Rev 3.pdf PDF
Amendment 0009 Final.pdf PDF
EB609 Rev 1.pdf PDF
10 56 13 Rev.pdf PDF
25 10 10.00 24.pdf PDF
MW101 Rev 1.pdf PDF
EB131 Rev 1.pdf PDF
22 13 29 Rev.pdf PDF
VMF Site 1 from Sturgeon St.jpg JPG image
01 45 35 Rev.pdf PDF
Fueling Site From Sealion Road.jpg JPG image
08 11 16 Rev.pdf PDF
MW602 Rev 2.pdf PDF
EW301 Rev 1.pdf PDF
Fueling Site.jpg JPG image
SB503 Rev 1.pdf PDF
Gaurd booths.pdf PDF
EW611 Rev 3.pdf PDF
EW401 Rev 7.pdf PDF
03 30 00 Rev.pdf PDF
Sealion Road.jpg JPG image
EW621 Rev 4.pdf PDF
EW101 Rev 3.pdf PDF
EW627 Rev 6.pdf PDF
AB101 Rev 5.pdf PDF
KB Spit 2 - Pier Location.jpg JPG image
Show 40 more

Latest 50 of 145 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M A

T C

H

LI

N E

S E

E D

W G

E W

TPP2C

J H G F

E

T1

T2

T3

M A

TC

H

LIN

E

S E

E D

W G

E W

C1

EW301

P-02

P-04

PULL BOX PE-01

A1

EW502

C2

EW303

GAM-1

GAM-2

P-08

PULL BOX PE-04

P-10

EMBEDDED JUNCTION BOX

P-15

P-13P-14 EMBEDDED

JUNCTION BOX

P-16TP-1

P-01

XFMRTPPTB

TPP2B

TPP4B

P-03

SP-1

GUARD HOUSE

C1

EW303

C4

EW303

5"

1-1/2" 6

EW503

A1

TYPICAL SEISMIC JOINT

EW304

C3

P-59

P-47

P-57

P-56 P-17

LDS-3

P-58

5"

V MANHOLE P-01

A3

EW403

1"

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E P A R T M E N T

O F

T H E

N A V Y

N A V F A C

N W

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

S

IL

V E R D A L E W A S H

IN

G T O N

N A V A L

B A S E

K

IT

S A P B A N G O R

S

IL

V E R D A L E W A S H

IN

G T O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

:4 :5

A M

C U s e rs S b o ll e n D o c u m e n ts P M O D P

IE

R E L E C R S b o ll e n .r vt

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

P

IE

R

PO

W

ER

P

LA

N

S H

EE

T

N A V A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O M M A N D

N O R

TH

W

ES

T

BCPSMB BGA

EW111

215 269

16046563

DOUG BUSSARD

B. GALLOWAY

B. NIXON

SCALE: 1/8" = 1'-0"

PIER POWER PLAN - SHEET 1

SCALE:

8' 8'

1/8" = 1'-0"

16'16'

SHEET KEYNOTES:

1. PANEL PROVIDED WITH GUARD HOUSE. VERIFY LOCATION OF

PANEL.

2. PANELS AND THEIR SUPPORTING STRUCTURE SHALL BE DESIGNED

TO RESIST A DISTRIBUTED LOAD OF 50 POUNDS PER LINEAR FOOT

APPLIED IN ANY DIRECTION AT A HEIGHT OF 3'-6" OR A POINT

LOAD OF 200 LBS APPLIED IN ANY DIRECTION AT A HEIGHT OF

3'-6."

3. COORDINATE CONDUIT ROUTING AND EQUIPMENT CONNECTION

POINTS WITH GATE AND TURNSTILE MANUFACTURER.

4. REFER TO MECHANICAL PLANS FOR LIFT STATION CONTROL PANEL.

5. REFER TO MECHANICAL PLANS FOR LEAK DETECTION PANEL.

6. (4) CONDUITS, TWO FOR 480V POWER TO THE PUMPS, AND TWO

FOR PUMP CONTROLS.

7. PROVIDE 6'X6'X6' MANHOLE.

GENERAL NOTES:

1. REFER TO POWER CONDUIT SCHEDULES ON SHEETS EW624 AND

EW625.

2. REFER TO MOTOR AND EQUIPMENT WIRING SCHEDULE ON SHEET

EW621.

KEY PLAN

N

P

PI

S M B

P

PI

0/

S M B

Sheets
EW111 - PIER POWER PLAN - SHEET 1
EW404 - ENLARGED PLAN - KB DOCK NORTH
EW621 - ELECTRICAL SCHEDULES

File details come from the government source that posted it. Updated .