AB101 Rev 5.pdf
PDF 303 KB Posted
- Attached to
- Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
- Solicitation number
- n44255
About this file
The document includes a first floor plan for a proposed vehicle maintenance facility and a related federal contract opportunity solicitation. The floor plan depicts the layout of the 18,278 square foot facility, including areas for vehicle repair bays, welding and production shops, hazardous materials storage, employee break areas, and restrooms. Key structural elements and notes are also indicated.
The solicitation seeks to construct a general purpose berthing pier and trestle with controlled access, along with an associated vessel maintenance facility, parking area, and fuel distribution and storage system. These facilities would support the operations mission of the Maritime Force Protection Unit in Bangor to provide security escort for submarines transiting between homeport and the test range in the Strait of Juan de Fuca. The solicitation is issued by the Department of the Navy Naval Facilities Engineering Command for an opportunity designated as solicitation number N44255.
View the file
Other files for this federal contract opportunity
Show all 50
Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W D
AB201
A1
AB202
A1
AB201
C1
E
D
A
A1
AB301
C1
AB301
AB202
C1
6'
6"
7 9
C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
ENTRY
CORRIDOR
SUPERVISOR
OFFICE
106-B
SUPERVISOR
OFFICE
106-C
ELECTRONICS
TECHNICIAN
TRAILER
SHOP
PRODUCTION
SHOP
WELD
SHOP
REPAIR
BAY
REPAIR
BAY
REPAIR
BAY
SECURE
MATERIAL/PARTS
STORAGE
& ISSUE
HAZARDOUS
MATERIALS
STORAGE
COMMS
ELECTRICAL
MECHANICAL
MULTIPURPOSE
OPEN
OFFICE
BREAK
AREA
106-A
101-2
101-1
106-C-1
106-B-1
002-1
003-1
004-1
114-2
010-1
006-1008-1 007-1009-1 006-2
015-2
008-2 007-2009-2
114-1
005-1
119-1
C3
AB302
A3
AB302
8'
0"
B
A1
AB302
106-D-1
CLOSET
106-D
10' - 0" 25' - 0" 25' - 0" 27' - 6" 30' - 0" 27' - 6"
35' - 0" 25' - 0"
50' - 0"
2 22 2
2 22
AB402
A1
AB402
A3
AB403
A1
4 4 4
10' - 3"
B
B1
B1
B1
B1
B
B
B
B
B
AA
C
B
A
015-1
10' - 0"
107-1
110-1
35' - 10"
5'
6"
6' - 6" 3' - 9" 5' - 0" 3' - 9" 6' - 6" 1' - 6"
3' - 9" 5' - 0" 3' - 9"
6'
2"
2'
3" 3'
2"
8'
9"
3' - 6"
4'
0"
/2
/2
1"
MEN'S
RESTROOM
WOMEN'S
RESTROOM
JANITOR
104-1 103-1
105-1
A
A
1' - 4"
48' - 8"
001-1
4' - 0 1/2"
102-19
9 9 9 9 9 9
9 9 9 99 9
110-2
010-2
29 9
10' - 10 1/2"
FE
44 9 9
4 4
4 4 4
114-3
C2
AB501
EQ EQ EQ EQ
9 9 9 9 9 9
9 9 9 9 9 9 99
9 9
AB502
A1
4 44
HAZARDOUS
WASTE
ACCUMULATION
X118
FLAMMABLE
GAS
STORAGE
X117
ARGON
STORAGE
X116
OXIDIZER
STORAGE
X115
E Q
E Q
E Q
E Q
CORRIDOR
102-A
20 20
20 20
20 20
20 20
1' - 10 1/2" 3' - 1 1/2" 3' - 1 1/2" 1' - 10 1/2"
AB404
A1
B3
AB501
9'
1/
2"
3'
1"
8' - 6" ±
2' - 1" ±
3" W SAFETY YELLOW
DIAGONAL STRIPES @ 24" OC
LEGEND
1 HR FIRE BARRIER
FIRE EXTINGUISHER CABINET
PROVIDED BY GOVERNMENT
FE
701 N 36TH STREET, SUITE 330
SEATTLE, WA 98103
SCALE:
EPROJECT NO.:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
SHEET OF
DRAWFORM REVISION: 31 JANUARY 2017
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
AS NOTED
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
N A
V F
A C
N W
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
IL
V E
R D
A L
E
W A
S H
IN
G
T O
N
N A
V A
L B
A S
E K
IT
S
A P
B
A N
G O
R S
IL
V
E R
D A
L E
W
A S
H
IN
G T
O N
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
S
YM
D
ES
C R
IP
TI
O N
D A
TE
A P P R
FIRE PROTECTION
D. GIBSON/T. BOLING
1389895
RYAN HENDRYX
STATE OF WASHINGTON
REGISTERED
ARCHITECT
10445
B. KOPP
B. GALLOWAY
B. NIXON
:1 :5
P M
C U s e rs m h a h n D o c u m e n ts P B L D G A R N E W
C E N T R A L m h a h n M A V P .r vt
F Y
M
C O
N P
R O
J E
C T
P -9
T P
P P
IE
R
A N
D M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
F
IR
S T
F L
O O
R P
L A
N
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R T
H W
E S
T
MHRH KP
AB101
SCALE: 1/8" = 1'-0"A1
FIRST FLOOR PLAN
ROOF 15,275 SF
VMF COVERED AREAS (1/2 OF ACTUAL AREA) 725 SF
WASH RACK 2,278 SF
TOTAL VMF BUILDING AREA 18,278 SF
DD1391 AREA LIMITATION 18,290 SF
TABULATED BUILDING AREAS
1. REFER TO ID101 FOR FURNITURE, FIXTURES, AND EQUIPMENT (FF&E).
2. REFER TO AB603 FOR MATERIAL SCHEDULE.
3. PROVIDE 8'-0" H. 3/4" PAINTED PLYWOOD PROTECTION BOARD AT ALL
PRE-ENGINEERED EXTERIOR WALLS, TYP. REFER TO FINISH
SCHEDULE FOR LOCATIONS.
SHEET NOTESSHEET KEYNOTES
1 DRINKING FOUNTAIN
2 OVERHEAD COILING DOOR
3 EXPANDED METAL MESH PANEL
4 COLUMN; PT4
5 EXPANDED METAL MESH BUILT-IN STORAGE ALCOVE; PT5
6 UTILITY SINK AND PAPER TOWEL DISPENSER
7 HIGH PERFORMANCE TRANSLUCENT PANEL
8 EMERGENCY SHOWER WITH EYE WASH
9 6" DIAMETER BOLLARD, 42" HEIGHT; PT5
10 MECHANICAL EQUIPMENT FIXED ACCESS LADDER; PT5
11 CONCRETE SIDEWALK - SEE CIVIL
12 SURFACE MOUNTED PERFORATED METAL BENCH
13 ACTIVE LEAF
14 CARD READER
15 40' L x 10' D x 10' H PRE-FABRICATED HAZARDOUS MATERIALS STORAGE
BUILDING WITH 4-HR BI-DIRECTIONAL FIRE RATING (4 COMPARTMENT)
16 BUILT-IN BATTERY CLOSED STORAGE SHELF UNIT, 24"D x 48"W; PT5
17 BUILT-IN TIRE RACK
18 BUILT-IN STORAGE RACK, 24"D x 96"W; PT5
19 BUILT-IN CLOSED STORAGE SHELF UNIT, 24"D x 48"W; PT5
20 TUBE STEEL COLUMN
21 BUILT-IN STORAGE RACK, 36"D x 96"W; PT5
22 8"H HELVETICA BLACK LETTERING "NO STORAGE" AT 15'-0" H. COORDINATE
HORIZONTAL POSITION WITH BUILT-IN STORAGE RACKS, TYP.
23 3/4" SOLID SURFACE COUNTER OVER 3/4" PLYWOOD WITH 2" GROMMETS IN EACH
CORNER. FRONT OF COUNTER TO HAVE 3/4" THICK x 2" HIGH VERTICAL FACE.
HEAT SEAM WHERE VERTICAL AND HORIZONTAL SOLID SURFACE MEET.
SUPPORT COUNTERS SIMILARLY TO COUNTERS IN BREAK ROOM AND
RESTROOMS.
0' 4' 8' 16' 1/8" = 1'-0"
ELEMENT ASSEMBLY MAXIMUM
ROOF U-0.039
WALL U-0.060
BUILDING ENVELOPE REQUIREMENTS
1. ALL EXTERIOR METAL ELEMENTS TO BE PT3, UNO.
2. ALL INTERIOR EXPOSED COLUMNS AND BEAMS TO BE PT4, UNO.
COLOR NOTES
16046682
P
PI
5 5
8.
.2
M C H
P
PI
8 4
8.
.2
M C H
P
PI
3 9
0.
.2
M C H
| Sheets |
| AB101 - FIRST FLOOR PLAN |
File details come from the government source that posted it. Updated .