EW101 Rev 3.pdf

PDF 261 KB Posted

Attached to
Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
Solicitation number
n44255
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document includes an electrical site plan drawing and related federal contract solicitation. The electrical site plan drawing depicts the layout of existing and proposed electrical infrastructure to support construction of a general purpose berthing pier and tessel with controlled access, vessel maintenance facility and parking, and fuel distribution and storage system. The project is required to support maritime force protection operations for the Naval Base Kitsap Bangor security escort mission. The solicitation seeks amendment responses by applicable small businesses for the contract to construct these facilities to enable stand-up of the Nuclear Weapons Security Program mission as mandated by national security directives. The Naval Facilities Engineering Command is the contracting agency. Key information includes the project scope, response deadline, involved federal organizations, and small business set-aside designation.

View the file

Other files for this federal contract opportunity

Other files attached to Amendment 0010 -Use the applicable Small Business Forms attached, newest first.
File Type Posted
VMF Site 1 from Sturgeon St.jpg JPG image
KB Spit 1 - Pier Location.jpg JPG image
MW101 Rev 1.pdf PDF
EW111 Rev 2.pdf PDF
EB131 Rev 1.pdf PDF
22 13 29 Rev.pdf PDF
08 41 13 Rev.pdf PDF
EW404 Rev 3.pdf PDF
Attachment K.docx DOCX document
01 32 17.00 20 Rev.pdf PDF
Sealion Road.jpg JPG image
VMF SIte 3 from Sturgeon St.jpg JPG image
VMF Site 2 from Sturgeon St.jpg JPG image
106 Rev 1.pdf PDF
EW122 Rev 1.pdf PDF
EB606 Rev 1.pdf PDF
MW412 Rev 1.pdf PDF
EW613 Rev 2.pdf PDF
SW521 Rev 2.pdf PDF
09 90 00 Rev.pdf PDF
33 52 11 Rev.pdf PDF
Amendment 0007.pdf PDF
Revised_Sections 00100 and 00800.pdf PDF
P907 TPS Geotech Report_0006.pdf PDF
P907 TPS UST Site Assess Report_0006.pdf PDF
PPIs Continued.pdf PDF
P907_Amend0006_Specs.pdf PDF
P907_Amend0006_Drawings.pdf PDF
EW404 Rev 1.pdf PDF
EW602 Rev 1.pdf PDF
EW611 Rev 1.pdf PDF
AB104 Rev1.pdf PDF
SW526 Rev 1.pdf PDF
EW612 Rev 1.pdf PDF
31 62 16.19.pdf PDF
SW601 Rev 1.pdf PDF
AB101 Rev 1.pdf PDF
EW601 Rev 1.pdf PDF
AB502 Rev 1.pdf PDF
CW161 Rev 1.pdf PDF
EW602 Rev 2.pdf PDF
Amendment 0004.pdf PDF
SF30 Continuation rev.pdf PDF
SITES WALK.pdf PDF
Amendment 0002 SF30.pdf PDF
Amend_1_Page_2.pdf PDF
Amendment 0001.docx DOCX document
RFP Attachment K_EXAMPLE Overhead Forms.xlsx XLSX spreadsheet
Attachment J.pdf PDF
Sections A-L forms.pdf PDF
Show all 50

Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

D

W

S

S

D

P

D

P

S

P

P

W

P

D

P

P

S

H O O D C A N A L

SEA LION ROAD

SEA LION ROAD

H O O D C A N A L

H O O D C A N A L

STAIRS

EX

. B

UIL

DIN

G

5'x11'

STEEL-TRAILER'S

(T-100A&B)

EX

BU

ILD

ING

T-

EX. BUILDING

P-990B

EX.

BUILDING

T116

64.7'9 .3

22.1'

.4

.4

17.9'

1.0'

.5

41.7'

.2

12.5'

.9

9.0' 8.8'

32.7'

2.6'

.3

.7

.0

.0

.0

1.0'

1.7'

1.7'

14.7'

.8

.5'

.8

.0'

.4

4"FM*

4"FM*

4"FM*

4"FM*

4"FM*

4"

FM

8"P

VC

ABA

NDO

NED

AD

S

S P E E D

B U M P

S P E E D

B U M P

SP

EE

D

BU

MP

SP

EE

D

BU

MP

"D .I.

24"D.I.*

24"D.I.*

24"D.I.*

8"D .I.

24"D.I.*

MULTIPLE ELECT RIC

AL C

ONDUITS

V-01

EXISTING COMM VAULT

B7136 PAD

MOUNTED SWITCH

MATCHLINE SEE DWG EW111,EW121,EW131

(2) 4"C2

EXISTING PAD MOUNTED

TERMINATING CABINET P3/T1(JC-1)

P3

T2

P3

M3

P3

M4

P3

M2

B7136

V-04

V-02

(E) KB DOCK

A1

EW401

V-10

V-094

EXISTING COMM VAULT

V-08

A1

EW402

A1

EW404

A1

EW405

5"

4"

4"

4"

5"

4"

4"

4"

2"

JC-2

5"

B1

EW403

2"

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E P A R T M E N T

O F

T H E

N A V Y

N A V F A C

N W

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

S

IL

V E R D A L E W A S H

IN

G T O N

N A V A L

B A S E

K

IT

S A P B A N G O R

S

IL

V E R D A L E W A S H

IN

G T O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

:3 :3

A M

C U s e rs S b o ll e n D o c u m e n ts P M O D P

IE

R E L E C R S b o ll e n .r vt

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

EL

EC

TR

IC

A L S

IT

E P

LA

N

N A V A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O M M A N D

N O R

TH

W

ES

T

BCPSMB BGA

EW101

214 269

16046562

DOUG BUSSARD

B. GALLOWAY

B. NIXON

SCALE:

50' 50'

1" = 50'-0"

100'100'

SHEET KEYNOTES:

1. EXISTING CONDUITS FROM COMM VAULT UP TO 2ND

FLOOR COMM ROOM.

2. REMOVE EXISTING FEEDER F-514 FROM EXISTING

DUCTBANK. TURN OVER REMOVED CONDUCTORS TO

THE BANGOR RECYCLE CENTER B1460.

3. PROVIDE FEEDER FWE8 IN EXISTING DUCTBANK.

4. STUB CONDUITS INTO EXISTING COMM VAULT.

5. STUB OUT CONDUIT AND CAP UNDER KB DOCK.

6. PROVIDE (3) 3-CELL FABRIC INNERDUCTS IN

CONDUIT. PROVIDE TWO 24-STRAND SINGLE-MODE

OPTICAL FIBER CABLES FROM RADAR STATION TO

VAULT-01. MATCH EXISTING CABLE TYPE AND

MANUFACTURER (SYSTIMAX TERASPEED). TERMINATE

CABLES AT RADAR STATION. SPLICE CABLES INTO

EXISTING CABLES IN THE EXISTING SPLICE

ENCLOSURE IN THE COMMUNICATION VAULT

V-01. MATCH CABLE CONNECTORS AND METHOD OF

SPLICING AT CABLE ENDS WITH THE EXISTING.

COORDINATE WORK SCHEDULE/DOWNTIME DURATION,

CUTOVER OF EXISTING CABLES WITH NEW CABLES,

TESTING AND LABELING OF THE CABLES WITH

SWFPAC. RADAR STATION TO REMAIN IN OPERATION

THROUGHOUT CONSTRUCTION EXCEPT FOR SWFPAC

APPROVED SHUTDOWN PERIOD.

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN

A1

GENERAL NOTES:

1. REFER TO EW627 FOR COMM ENCLOSURE, PULL BOX,

AND VAULT SCHEDULE AND SYSTEMS CABLE

SCHEDULE.

2. REFER TO EW628 FOR SYSTEMS PATHWAY SCHEDULE.

3. FOR TYPICAL DUCTBANK DETAIL SEE C3/EW502.

4. RACEWAYS INSTALLED ON THIS SHEET ARE NOT

INCLUDED IN THE CONDUIT SCHEDULE.

5. PROVIDE (3) 3-CELL FABRIC INNERDUCTS IN EACH

4" COMMUNICATIONS CONDUIT. 1

P

PI

S M B

P

PI

S M B

P

PI

0/

S M B

Sheets
EW101 - ELECTRICAL SITE PLAN
EW628 - ELECTRICAL SCHEDULES

File details come from the government source that posted it. Updated .