This document includes an electrical site plan drawing and related federal contract solicitation. The electrical site plan drawing depicts the layout of existing and proposed electrical infrastructure to support construction of a general purpose berthing pier and tessel with controlled access, vessel maintenance facility and parking, and fuel distribution and storage system. The project is required to support maritime force protection operations for the Naval Base Kitsap Bangor security escort mission. The solicitation seeks amendment responses by applicable small businesses for the contract to construct these facilities to enable stand-up of the Nuclear Weapons Security Program mission as mandated by national security directives. The Naval Facilities Engineering Command is the contracting agency. Key information includes the project scope, response deadline, involved federal organizations, and small business set-aside designation.

View the file

Other files

File Type Posted
Sections B- F-G forms.pdf PDF
Rev1442.pdf PDF
SF30 Amendment 0010.pdf PDF
SB106 Rev 2.pdf PDF
EW404 Rev 3.pdf PDF
01 32 17.00 20 Rev.pdf PDF
Attachment K.docx DOCX document
VMF SIte 3 from Sturgeon St.jpg JPG image
EW626 Rev 1.pdf PDF
Answer Attachment.xlsx XLSX spreadsheet
KB Spit 1 - Pier Location.jpg JPG image
MW301 Rev 1.pdf PDF
EW628 Rev 4.pdf PDF
Fueling Site rev.jpg JPG image
MB602 Rev 1.pdf PDF
EW303 Rev 2.pdf PDF
EB603 Rev 1.pdf PDF
08 41 13 Rev.pdf PDF
MW103 Rev 1.pdf PDF
EW623 Rev 2.pdf PDF
MW102 Rev 1.pdf PDF
EB605 Rev 3.pdf PDF
EB606 Rev 2.pdf PDF
MB603 Rev 1.pdf PDF
EB101 Rev 3.pdf PDF
Amendment 0009 Final.pdf PDF
EB609 Rev 1.pdf PDF
10 56 13 Rev.pdf PDF
25 10 10.00 24.pdf PDF
MW101 Rev 1.pdf PDF
EB131 Rev 1.pdf PDF
22 13 29 Rev.pdf PDF
VMF Site 1 from Sturgeon St.jpg JPG image
01 45 35 Rev.pdf PDF
Fueling Site From Sealion Road.jpg JPG image
08 11 16 Rev.pdf PDF
EW111 Rev 2.pdf PDF
MW602 Rev 2.pdf PDF
EW301 Rev 1.pdf PDF
Fueling Site.jpg JPG image
SB503 Rev 1.pdf PDF
Gaurd booths.pdf PDF
EW611 Rev 3.pdf PDF
EW401 Rev 7.pdf PDF
03 30 00 Rev.pdf PDF
Sealion Road.jpg JPG image
EW621 Rev 4.pdf PDF
EW627 Rev 6.pdf PDF
AB101 Rev 5.pdf PDF
KB Spit 2 - Pier Location.jpg JPG image
Show 40 more

Latest 50 of 145 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

D

W

S

S

D

P

D

P

S

P

P

W

P

D

P

P

S

H O O D C A N A L

SEA LION ROAD

SEA LION ROAD

H O O D C A N A L

H O O D C A N A L

STAIRS

EX

. B

UIL

DIN

G

5'x11'

STEEL-TRAILER'S

(T-100A&B)

EX

BU

ILD

ING

T-

EX. BUILDING

P-990B

EX.

BUILDING

T116

64.7'9 .3

22.1'

.4

.4

17.9'

1.0'

.5

41.7'

.2

12.5'

.9

9.0' 8.8'

32.7'

2.6'

.3

.7

.0

.0

.0

1.0'

1.7'

1.7'

14.7'

.8

.5'

.8

.0'

.4

4"FM*

4"FM*

4"FM*

4"FM*

4"FM*

4"

FM

8"P

VC

ABA

NDO

NED

AD

S

S P E E D

B U M P

S P E E D

B U M P

SP

EE

D

BU

MP

SP

EE

D

BU

MP

"D .I.

24"D.I.*

24"D.I.*

24"D.I.*

8"D .I.

24"D.I.*

MULTIPLE ELECT RIC

AL C

ONDUITS

V-01

EXISTING COMM VAULT

B7136 PAD

MOUNTED SWITCH

MATCHLINE SEE DWG EW111,EW121,EW131

(2) 4"C2

EXISTING PAD MOUNTED

TERMINATING CABINET P3/T1(JC-1)

P3

T2

P3

M3

P3

M4

P3

M2

B7136

V-04

V-02

(E) KB DOCK

A1

EW401

V-10

V-094

EXISTING COMM VAULT

V-08

A1

EW402

A1

EW404

A1

EW405

5"

4"

4"

4"

5"

4"

4"

4"

2"

JC-2

5"

B1

EW403

2"

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E P A R T M E N T

O F

T H E

N A V Y

N A V F A C

N W

N A V A L

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

S

IL

V E R D A L E W A S H

IN

G T O N

N A V A L

B A S E

K

IT

S A P B A N G O R

S

IL

V E R D A L E W A S H

IN

G T O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

:3 :3

A M

C U s e rs S b o ll e n D o c u m e n ts P M O D P

IE

R E L E C R S b o ll e n .r vt

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

EL

EC

TR

IC

A L S

IT

E P

LA

N

N A V A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O M M A N D

N O R

TH

W

ES

T

BCPSMB BGA

EW101

214 269

16046562

DOUG BUSSARD

B. GALLOWAY

B. NIXON

SCALE:

50' 50'

1" = 50'-0"

100'100'

SHEET KEYNOTES:

1. EXISTING CONDUITS FROM COMM VAULT UP TO 2ND

FLOOR COMM ROOM.

2. REMOVE EXISTING FEEDER F-514 FROM EXISTING

DUCTBANK. TURN OVER REMOVED CONDUCTORS TO

THE BANGOR RECYCLE CENTER B1460.

3. PROVIDE FEEDER FWE8 IN EXISTING DUCTBANK.

4. STUB CONDUITS INTO EXISTING COMM VAULT.

5. STUB OUT CONDUIT AND CAP UNDER KB DOCK.

6. PROVIDE (3) 3-CELL FABRIC INNERDUCTS IN

CONDUIT. PROVIDE TWO 24-STRAND SINGLE-MODE

OPTICAL FIBER CABLES FROM RADAR STATION TO

VAULT-01. MATCH EXISTING CABLE TYPE AND

MANUFACTURER (SYSTIMAX TERASPEED). TERMINATE

CABLES AT RADAR STATION. SPLICE CABLES INTO

EXISTING CABLES IN THE EXISTING SPLICE

ENCLOSURE IN THE COMMUNICATION VAULT

V-01. MATCH CABLE CONNECTORS AND METHOD OF

SPLICING AT CABLE ENDS WITH THE EXISTING.

COORDINATE WORK SCHEDULE/DOWNTIME DURATION,

CUTOVER OF EXISTING CABLES WITH NEW CABLES,

TESTING AND LABELING OF THE CABLES WITH

SWFPAC. RADAR STATION TO REMAIN IN OPERATION

THROUGHOUT CONSTRUCTION EXCEPT FOR SWFPAC

APPROVED SHUTDOWN PERIOD.

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN

A1

GENERAL NOTES:

1. REFER TO EW627 FOR COMM ENCLOSURE, PULL BOX,

AND VAULT SCHEDULE AND SYSTEMS CABLE

SCHEDULE.

2. REFER TO EW628 FOR SYSTEMS PATHWAY SCHEDULE.

3. FOR TYPICAL DUCTBANK DETAIL SEE C3/EW502.

4. RACEWAYS INSTALLED ON THIS SHEET ARE NOT

INCLUDED IN THE CONDUIT SCHEDULE.

5. PROVIDE (3) 3-CELL FABRIC INNERDUCTS IN EACH

4" COMMUNICATIONS CONDUIT. 1

P

PI

S M B

P

PI

S M B

P

PI

0/

S M B

Sheets
EW101 - ELECTRICAL SITE PLAN
EW628 - ELECTRICAL SCHEDULES