MW103 Rev 1.pdf
PDF 419 KB Posted
- Attached to
- Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
- Solicitation number
- n44255
About this file
This solicitation and accompanying drawings outline requirements for a maritime construction project. The Navy seeks to construct a general purpose berthing pier and trestle with controlled access, a vessel maintenance facility with parking and fuel distribution and storage systems. These facilities will support the operations of the Maritime Force Protection Unit in Bangor to provide security escort for submarines transiting through the Strait of Juan de Fuca and test ranges. The solicitation number is n44255 and was issued by the Department of the Navy Naval Facilities Engineering Command. The drawings depict plans for the pier and trestle showing locations of utilities like potable water, oily waste, and sanitary sewer lines. Key details include specifications for insulation and weatherproof jackets on utility lines in trenches.
View the file
Other files for this federal contract opportunity
Show all 50
Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M W
M W
3" OILY WASTE, DOUBLE
CONTAINED (PUMPED)
4" SANITARY SEWER
(PUMPED)
D
C
B
A
7 8 9 10 11 12
C1
MW601
A3
MW402
C2
MW601
SP-3 1-1/2"
C4
MW601
B3
MW402
8" POTABLE WATER
OPPOSITE HAND
OW RISER NO. 6
SS RISER NO. 4
PAPW-6
RISER VALVE TREE IS ABOVE TRENCH LID
telephone: 206.448.1911
2301 Fifth Avenue, Suite 401 www.notkin.com facsimile: 206.448.9485
Seattle, WA 98121
Contact: Peter Sloane, P.E.
notkin#: 217069 mechanical engineers notkin
SCALE:
EPROJECT NO.:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
SHEET OF
DRAWFORM REVISION: 31 JANUARY 2017
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
AS NOTED
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
N A
V F
A C
N W
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
IL
V E
R D
A L
E W
A S
H
IN
G T
O N
N A
V A
L B
A S
E K
IT
S
A P
-B A
N G
O R
S
IL
V E
R D
A L E
W
A S
H
IN
G T
O N
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
S
YM
D
ES
C R
IP
TI
O N
D A
TE
A P P R
FIRE PROTECTION
D. GIBSON/T. BOLING
1389895
K. PAULSON
/2 /2
:2
:1
P M
C R e v it P ro je c ts
\P -9
\P
-P
IE
R
-1
-M
E C
H -R d e ta c h e d
.r v t
F Y
M
C O
N P
R O
J E
C T
P -9
T P
P P
IE
R
A N
D M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
T P
P T
R E
S T
LE
A
N D
P
IE
R P
LA
N
A
R E
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R T
H W
E S
T
RRRPS LDS
MW103
193 269
16046541
B. GALLOWAY
B. NIXON
SCALE: 1/8" = 1'-0"
TPP TRESTLE AND PIER PLAN - AREA 3
NA1
0' 4' 8' 16'
SHEET KEYNOTES:
PROVIDE HEAT TRACE JUNCTION BOX
AT BASE OF RISER FOR POWER
CONNECTION TO RISER HEAT TRACE
SYSTEM.
PROVIDE 1" INSULATION & T316 SST
WEATHER JACKET ON PW PIPE AND
FITTINGS IN TRENCHES.
PROVIDE 1/2" INSULATION & T316 SST
WEATHER JACKET ON OW AND SS PIPE,
FITTINGS, AND VALVES IN TRENCHES.
SUMP PUMP TIES INTO THE SANITARY
SEWER MAIN THROUGH A 1.5" CHECK
VALVE, BALL VALVE, AND PIPE. SEE
DETAIL A3/MW502.
PW RISER NO. 2 (NORTH END)
1.
2.
3.
4.
5.
SCALE: NONE
KEY PLAN
P
PI
0/
A
JM
| Sheets |
| MW103 - TPP TRESTLE AND PIER PLAN - AREA 3 |
File details come from the government source that posted it. Updated .