EB131 Rev 1.pdf
PDF 199 KB Posted
- Attached to
- Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
- Solicitation number
- n44255
About this file
This document contains a systems floor plan and partial electrical site plan for a facility renovation project. The plans show the layout of rooms, locations of electrical equipment and devices, and notes specifying installation requirements. Relevant details include that the project is for the renovation of Building 1389895 to support operations of the Maritime Force Protection Unit at Naval Base Kitsap in Bangor, Washington. Electrical work shown on the plans includes installation of pull boxes, conduit routing, and mounting locations and heights for electrical boxes and devices.
View the file
Other files for this federal contract opportunity
Show all 50
Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0/3/1
0/1/0
0/1/0
0/1/0 +72"
1/0/0 +48"
1/1/11/1/1
1/0/0 +48"
1/0/0 +48"
1/0/0 +48"
CR
CR
CR CR
KP
KP
0/1/0
0/1/0
2/1/1
2/1/1
0/3/1
1/1/0 +48
KP
ENTRY
CORRIDOR
SUPERVISOR
OFFICE
106-B
SUPERVISOR
OFFICE
106-C
ELECTRONICS
TECHNICIAN
TRAILER
SHOP
PRODUCTION
SHOP
WELD
SHOP
REPAIR
BAY
REPAIR
BAY
REPAIR
BAY
SECURE
MATERIAL/PARTS
STORAGE
& ISSUE
HAZARDOUS
MATERIALS
STORAGE
COMMS
ELECTRICAL
MECHANICAL
MULTIPURPOSE
OPEN
OFFICE
BREAK
AREA
106-A
CLOSET
106-D
MEN'S
RESTROOM
WOMEN'S
RESTROOM
JANITOR
HAZARDOUS
WASTE
ACCUMULATION
X118
FLAMMABLE
GAS
STORAGE
X117
ARGON
STORAGE
X116
OXIDIZER
STORAGE
X115
CORRIDOR
102-A
E
D
A
52 6
7 9
C
B
B2
EB402
4"C
4"C
PULLBOX
PULLBOX
ZONE PULLBOX
015-2015-2
010-1010-1 006-1
119-1
114-2114-2
001-1001-1
2"C
ZONE PULLBOX
PULLBOX
2"C 2"C
2"C
2"C
PULLBOXZONE PULLBOX
2"C
2"C
2"C
2"C (TYP)
2"C 2"C
SCALE:
EPROJECT NO.:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
SHEET OF
DRAWFORM REVISION: 31 JANUARY 2017
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
AS NOTED
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
D E P A R T M E N T
O F
T H E
N A V Y
N A V F A C
N W
N A V A L
F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
S
IL
V E R D A L E W A S H
IN
G T O N
N A V A L
B A S E
K
IT
S A P B A N G O R
S
IL
V E R D A L E W A S H
IN
G T O N
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
S
YM
D
ES
C R
IP
TI
O N
D A
TE
A P P R
FIRE PROTECTION
D. GIBSON/T. BOLING
1389895
:3 :4
A M
C U s e rs S b o ll e n D o c u m e n ts P B L D G E L E C R S b o ll e n .r vt
F Y
M
C O
N P
R O
J E
C T
P -9
T P
P P
IE
R
A N
D M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
S
YS
TE
M S
FL
O O R
P
LA
N
N A V A L
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
C O M M A N D
N O R
TH
W
ES
T
BCPSMB BGA
EB131
117 135
16046742
D. BUSSARD
B. GALLOWAY
B. NIXON
SCALE:
8' 8'
1/8" = 1'-0"
16'16'
GENERAL NOTES:
SHEET KEYNOTES:
1. ROUTE CONDUITS FROM BACK BOXES OR DEVICE TO CLOSEST PULLBOX OR
ZONE PULLBOX.
2. PROVIDE 24x24x8 INCH PULLBOXES AND ZONE PULLBOXES AT LOCATIONS
SHOWN ON THIS SHEET.
N
SCALE: 1/8" = 1'-0"
SYSTEMS FLOOR PLAN
A1
1. SEE SHEET EB101 FOR CONTINUATION.
2. MOUNT BOX BELOW BEAM AT 18" ABOVE TOP OF ROLL UP DOOR STRUCTURE LINE.
3. MOUNT BOX AT 162"AFF TO BOTTOM OF BOX.
P
PI
0/
S M B
| Sheets |
| EB101 - PARTIAL ELECTRICAL SITE PLAN |
| EB131 - SYSTEMS FLOOR PLAN |
File details come from the government source that posted it. Updated .