This document includes plans for a general purpose berthing pier and trestle with controlled access, vessel maintenance facility with parking, fuel distribution and storage system to support the Maritime Force Protection Unit (MFPU) Bangor's operations mission. The project constructs facilities including a pier, trestle, abutment utility vault, lift station pump control panel, and leak detection system. Utilities routed through trenches will include 8-inch potable water, 4-inch sanitary sewer, and double contained 3-inch oily waste pipes. The leak detection system will include sensors in containment boxes on the pier, trestle, abutment utility vault connected by cable to a monitoring and alarm panel. The solicitation is issued by the Department of the Navy Naval Facilities Engineering Command for these construction services.

View the file

Other files for this federal contract opportunity

Other files attached to Amendment 0010 -Use the applicable Small Business Forms attached, newest first.
File Type Posted
VMF Site 1 from Sturgeon St.jpg JPG image
KB Spit 1 - Pier Location.jpg JPG image
EW111 Rev 2.pdf PDF
EB131 Rev 1.pdf PDF
22 13 29 Rev.pdf PDF
08 41 13 Rev.pdf PDF
EW404 Rev 3.pdf PDF
Attachment K.docx DOCX document
01 32 17.00 20 Rev.pdf PDF
106 Rev 1.pdf PDF
MW412 Rev 1.pdf PDF
EW613 Rev 2.pdf PDF
SW521 Rev 2.pdf PDF
MW602 Rev 1.pdf PDF
SB106 Rev 1.pdf PDF
SB102 Rev 7.pdf PDF
MW601 Rev 2.pdf PDF
MW401 Rev 1.pdf PDF
33 56 10 Rev.pdf PDF
Amendment 0007.pdf PDF
Revised_Sections 00100 and 00800.pdf PDF
P907 TPS Geotech Report_0006.pdf PDF
P907 TPS UST Site Assess Report_0006.pdf PDF
PPIs Continued.pdf PDF
P-876 AS-Built_E130_0006.pdf PDF
Amendment 0006.pdf PDF
P907 TPP Pier Geotech Report_0006.pdf PDF
EW404 Rev 1.pdf PDF
EW602 Rev 1.pdf PDF
EW611 Rev 1.pdf PDF
AB104 Rev1.pdf PDF
SW526 Rev 1.pdf PDF
EW401 Rev4.pdf PDF
CS501 Rev 1.pdf PDF
EW629 Rev 1.pdf PDF
P-907 ESA_Requirements.pdf PDF
01 14 00.pdf PDF
05 52 00.pdf PDF
P907 TPS UST Site Assessment Report.pdf PDF
EW001 Rev 1.pdf PDF
AB501 Rev 1.pdf PDF
1100 kW Generator Photo Collection.pdf PDF
P907 TPS Fuel Facility and Vessel Maintenance Facility Geotechnical Report.pdf PDF
EW603 Rev1.pdf PDF
Amendment 0004.pdf PDF
SF30 Continuation rev.pdf PDF
Amendment 0002 SF30.pdf PDF
Amend_1_Page_2.pdf PDF
RFP Attachment K_EXAMPLE Overhead Forms.xlsx XLSX spreadsheet
Attachment J.pdf PDF
Show all 50

Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8" POTABLE WATER

4" SANITARY SEWER, DOUBLE

CONTAINED (PUMPED)

3" OILY WASTE, DOUBLE

CONTAINED (PUMPED)

C3

MW301

J H G F

T1

T2

T3

M W

M W

3 3

A1

MW402

4" SS UNDERGROUND

3" OILY WASTE

UNDERGROUND

M W

M W

TRESTLE

ABUTMENT (SHORE SIDE)

8"PW SEE CW154

B1

MW301

LIFT STATION PUMP CONTROL PANEL 6

LEAK DETECTION PANEL 4LDS-3

A1

MW413

VAULT

SUMP

telephone: 206.448.1911

2301 Fifth Avenue, Suite 401 www.notkin.com facsimile: 206.448.9485

Seattle, WA 98121

Contact: Peter Sloane, P.E.

notkin#: 217069 mechanical engineers notkin

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

N A

V F

A C

N W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

IL

V E

R D

A L

E W

A S

H

IN

G T

O N

N A

V A

L B

A S

E K

IT

S

A P

-B A

N G

O R

S

IL

V E

R D

A L E

W

A S

H

IN

G T

O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

K. PAULSON

/2 /2

:2

:0

P M

C R e v it P ro je c ts

\P -9

\P

-P

IE

R

-1

-M

E C

H -R d e ta c h e d

.r v t

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

T P

P T

R E

S T

LE

A

N D

P

IE

R P

LA

N

A

R E

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R T

H W

E S

T

IRRPS LDS

MW101

191 269

16046539

B. GALLOWAY

B. NIXON

SCALE: 1/8" = 1'-0"

TPP TRESTLE AND PIER PLAN - AREA 1

A1

N0' 4' 8' 16'

SHEET KEYNOTES:

NOT USED.

PROVIDE 1" INSULATION & T316 SST

WEATHER JACKET ON PW PIPE AND

FITTINGS IN TRENCHES.

PROVIDE 1/2" INSULATION & T316 SST

WEATHER JACKET ON OW AND SS PIPE,

FITTINGS, AND VALVES IN TRENCHES.

PROVIDE LEAK DETECTION

MONITORING ALARM PANEL (LDS-3),

SEE A1/MW402. SEE ELECTRICAL

DRAWINGS FOR FIBER CABLE AND

CONDUIT TO NETWORK CABINET IN

FUELING FACILITY UTILITY ENCLOSURE.

PROVIDE SINGLE POINT

DISTINGUISHING LEAK SENSOR IN

EACH CONTAINMENT BOX ON PIER,

TRESTLE, AND ABUTMENT UTILITY

VAULT, AND CONNECTION CABLES IN

CONDUIT FROM SENSORS TO LEAK

DETECTION MONITORING / ALARM

PANEL LDS-3.

PROVIDE LIFT STATION PUMP CONTROL

PANEL, SEE A1/MW402.

1.

2.

3.

4.

5.

6.

SCALE: NONE

KEY PLAN

MW002, MW401, MW402

P

PI

0/

A

JM

Sheets
MW101 - TPP TRESTLE AND PIER PLAN - AREA 1

File details come from the government source that posted it. Updated .