MW102 Rev 1.pdf
PDF 470 KB Posted
- Attached to
- Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
- Solicitation number
- n44255
About this file
This document package includes plans for a maritime utility infrastructure project and a related federal solicitation. The plans detail piping layout and containment requirements for potable water, sanitary sewer, and oily waste lines running through a trestle and pier, including flow meters, valves, insulation, leak detection sensors and control panels. The solicitation from the Department of the Navy seeks bids to construct a berthing pier, trestle, vessel maintenance facility, fuel distribution and storage systems to support a Maritime Force Protection Unit's security escort and defense operations in the Strait of Juan de Fuca. Responses are due by a specified date.
View the file
Other files for this federal contract opportunity
Show all 50
Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MW101
M W
8" POTABLE WATER
4" SANITARY SEWER, DOUBLE
CONTAINED (PUMPED)
3" OILY WASTE, DOUBLE
CONTAINED (PUMPED)
8" POTABLE WATER
4" SANITARY SEWER, DOUBLE
CONTAINED (PUMPED)
3" OILY WASTE, DOUBLE
CONTAINED (PUMPED)
MW101
E
D
C
B
A
1 3 4 5 6
T1 T2 T3
A3
MW301
TRESTLE-PIER
SEISMIC JOINT
M W
PAOW-5
PASS-5
PAPW-5
C1
MW601
A3
MW402
C2
MW601
C4
MW601
B3
MW402
A1
MW301
4 6
B1
MW402
TRESTLE PIER
OW RISER NO. 5
SS RISER NO. 3
ARV-P1
A1
MW503
ARV-P3
A4
MW503
ARV-P2
A4
MW503
FM-3
FM-2
FM-1
20"X60"X20" HIGH8
20"X24"X20" HIGH 8
RISER VALVE TREE IS
ABOVE TRENCH LID
20"X20"X18" HIGH 10
C2
MW301
8 10
8 10
SP-2
1-1/2"
C1
MW301
HEAT TRACE PANEL
FLOW METER PANEL
ISOLATION VALVE12
ISOLATION
VALVE 12
telephone: 206.448.1911
2301 Fifth Avenue, Suite 401 www.notkin.com facsimile: 206.448.9485
Seattle, WA 98121
Contact: Peter Sloane, P.E.
notkin#: 217069 mechanical engineers notkin
SCALE:
EPROJECT NO.:
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
SHEET OF
DRAWFORM REVISION: 31 JANUARY 2017
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
AS NOTED
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
N A
V F
A C
N W
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S
IL
V E
R D
A L
E W
A S
H
IN
G T
O N
N A
V A
L B
A S
E K
IT
S
A P
-B A
N G
O R
S
IL
V E
R D
A L E
W
A S
H
IN
G T
O N
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
S
YM
D
ES
C R
IP
TI
O N
D A
TE
A P P R
FIRE PROTECTION
D. GIBSON/T. BOLING
1389895
K. PAULSON
/2 /2
:2
:3
P M
C R e v it P ro je c ts
\P -9
\P
-P
IE
R
-1
-M
E C
H -R d e ta c h e d
.r v t
F Y
M
C O
N P
R O
J E
C T
P -9
T P
P P
IE
R
A N
D M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
T P
P T
R E
S T
LE
A
N D
P
IE
R P
LA
N
A
R E
A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
N O
R T
H W
E S
T
KHRPS LDS
MW102
192 269
16046540
B. GALLOWAY
B. NIXON
SCALE: 1/8" = 1'-0"
TPP TRESTLE AND PIER PLAN - AREA 2
NA1 0' 4' 8' 16'
SHEET KEYNOTES:
PROVIDE HEAT TRACE JUNCTION BOX AT BASE
OF RISER FOR POWER CONNECTION TO RISER
HEAT TRACE SYSTEM.
PROVIDE 1" INSULATION & T316 SST WEATHER
JACKETON PW PIPE AND FITTINGS IN
TRENCHES.
PROVIDE 1/2" INSULATION & T316 SST WEATHER
JACKET ON OW AND SS PIPE, FITTINGS, AND
VALVES IN TRENCHES.
THE PIPES ELBOW DOWNWARD (IN THE
DIRECTION NORTHWARD TOWARDS THE PIER
SHIP UTILITY CONNECTIONS)
SUMP PUMP TIES INTO THE SANITARY SEWER
MAIN THROUGH A 1.5" CHECK VALVE, BALL
VALVE, AND PIPE. SEE DETAIL A3/MW502.
PW RISER NO. 1 (SOUTH END)
PROVIDE FLOW METER WITH FLANGED
ISOLATION VALVE UPSTREAM AND
DOWNSTREAM.
PROVIDE ALL T316 SST 14 GA CONTAINMENT
BOX WITH GASKETED LID FLASHED AND
LATCHED TO PREVENT WATER INTRUSION.
PROVIDE 1/2" THICK FLEXIBLE ELASTOMERIC
CELLULAR INSULATION ON OUTSIDE OF
CONTAINMENT BOX. PROVIDE ENTRY BOOT AT
ALL WALL PENETRATIONS TO ACCOMODATE
DOUBLE WALL PIPE TO SINGLE WALL PIPE
INSIDE BOX, OR LEAK DETECTION CABLES, OR
CONTROL CABLES. SEE DETAIL C1 / MW412.
PROVIDE 316 SST NEMA 4X ENCLOSURE
(36"WX36"HX12" DEEP) MOUNTED UTILIZING SST
CHANNEL STRUT UP 36" ABOVE DECK TO
HOUSE (3) REMOTE TRANSMITTERS FOR FM-1,
FM-2, AND FM-3. SEE ELECTRICAL EW112 FOR
CONNECTION TO AMI MONITORING SYSTEM AND
CONDUIT ROUTING.
PROVIDE SINGLE POINT DISTINGUISHING LEAK
SENSOR IN EACH CONTAINMENT BOX ON PIER,
TRESTLE, AND ABUTMENT UTILITY VAULT, AND
CONNECTION CABLES IN CONDUIT FROM
SENSORS TO LEAK DETECTION MONITORING /
ALARM PANEL LDS-3 (SEE MW101 FOR
LOCATION).
PROVIDE 316 SST NEMA 4X ENCLOSURE
(36"WX36"HX12" DEEP) MOUNTED UTILIZING SST
CHANNEL STRUT UP 36" ABOVE DECK TO
HOUSE HEAT TRACE CONTROLS. PROVIDE
HEAT TRACE MULTIPOINT CONTROL AND
MONITORING SYSTEM PANEL (208/120 VOLT, 1
PHASE) INCLUDING COMMON HEAT TRACE
FAILURE ALARM AT LOCAL PANEL AND AT B1305
BASE MONITORING SYSTEM. SEE ELECTRICAL
EW112 AND EW113 FOR CONDUIT AND CABLE
ROUTING FROM HEAT TRACE PANEL. PROVIDE
WARNING SIGN ON FACE OF THE HEAT TRACE
ENCLOSURE WHICH READS: "HEAT TAPE
SYSTEM (SELF LIMITING). DO NOT DISCONNECT
POWER."
PROVIDE FLOW METER FM-1 WITH FLANGED
ISOLATION VALVES UPSTREAM AND
DOWNSTREAM WITH MINIMUM DISTANCE PER
METER SENSOR REQUIREMENTS. PROVIDE
1-1/2" THICK REMOVABLE INSULATION PAD
OVER METER FM-1 SENSOR AND VALVES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
SCALE: NONE
KEY PLAN
GENERAL NOTES:
PIPING SHOWN IS IN TRENCHES BELOW
THE DECK ACCESS LIDS UNLESS
NOTED OTHERWISE.
1.
P
PI
0/
A
JM
| Sheets |
| MW102 - TPP TRESTLE AND PIER PLAN - AREA 2 |
File details come from the government source that posted it. Updated .