MW102 Rev 1.pdf

PDF 470 KB Posted

Attached to
Amendment 0010 -Use the applicable Small Business Forms attached Federal contract opportunity
Solicitation number
n44255
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document package includes plans for a maritime utility infrastructure project and a related federal solicitation. The plans detail piping layout and containment requirements for potable water, sanitary sewer, and oily waste lines running through a trestle and pier, including flow meters, valves, insulation, leak detection sensors and control panels. The solicitation from the Department of the Navy seeks bids to construct a berthing pier, trestle, vessel maintenance facility, fuel distribution and storage systems to support a Maritime Force Protection Unit's security escort and defense operations in the Strait of Juan de Fuca. Responses are due by a specified date.

View the file

Other files for this federal contract opportunity

Other files attached to Amendment 0010 -Use the applicable Small Business Forms attached, newest first.
File Type Posted
VMF Site 1 from Sturgeon St.jpg JPG image
KB Spit 1 - Pier Location.jpg JPG image
MW101 Rev 1.pdf PDF
EW111 Rev 2.pdf PDF
EB131 Rev 1.pdf PDF
22 13 29 Rev.pdf PDF
08 41 13 Rev.pdf PDF
EW404 Rev 3.pdf PDF
Attachment K.docx DOCX document
01 32 17.00 20 Rev.pdf PDF
Sealion Road.jpg JPG image
VMF SIte 3 from Sturgeon St.jpg JPG image
VMF Site 2 from Sturgeon St.jpg JPG image
106 Rev 1.pdf PDF
EW122 Rev 1.pdf PDF
EB606 Rev 1.pdf PDF
MW412 Rev 1.pdf PDF
EW613 Rev 2.pdf PDF
SW521 Rev 2.pdf PDF
09 90 00 Rev.pdf PDF
33 52 11 Rev.pdf PDF
Amendment 0007.pdf PDF
Revised_Sections 00100 and 00800.pdf PDF
P907 TPS Geotech Report_0006.pdf PDF
P907 TPS UST Site Assess Report_0006.pdf PDF
PPIs Continued.pdf PDF
P907_Amend0006_Specs.pdf PDF
P907_Amend0006_Drawings.pdf PDF
EW404 Rev 1.pdf PDF
EW602 Rev 1.pdf PDF
EW611 Rev 1.pdf PDF
AB104 Rev1.pdf PDF
SW526 Rev 1.pdf PDF
EW612 Rev 1.pdf PDF
31 62 16.19.pdf PDF
SW601 Rev 1.pdf PDF
AB101 Rev 1.pdf PDF
EW601 Rev 1.pdf PDF
AB502 Rev 1.pdf PDF
CW161 Rev 1.pdf PDF
EW602 Rev 2.pdf PDF
Amendment 0004.pdf PDF
SF30 Continuation rev.pdf PDF
SITES WALK.pdf PDF
Amendment 0002 SF30.pdf PDF
Amend_1_Page_2.pdf PDF
Amendment 0001.docx DOCX document
RFP Attachment K_EXAMPLE Overhead Forms.xlsx XLSX spreadsheet
Attachment J.pdf PDF
Sections A-L forms.pdf PDF
Show all 50

Amendment 0010 -Use the applicable Small Business Forms attached has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MW101

M W

8" POTABLE WATER

4" SANITARY SEWER, DOUBLE

CONTAINED (PUMPED)

3" OILY WASTE, DOUBLE

CONTAINED (PUMPED)

8" POTABLE WATER

4" SANITARY SEWER, DOUBLE

CONTAINED (PUMPED)

3" OILY WASTE, DOUBLE

CONTAINED (PUMPED)

MW101

E

D

C

B

A

1 3 4 5 6

T1 T2 T3

A3

MW301

TRESTLE-PIER

SEISMIC JOINT

M W

PAOW-5

PASS-5

PAPW-5

C1

MW601

A3

MW402

C2

MW601

C4

MW601

B3

MW402

A1

MW301

4 6

B1

MW402

TRESTLE PIER

OW RISER NO. 5

SS RISER NO. 3

ARV-P1

A1

MW503

ARV-P3

A4

MW503

ARV-P2

A4

MW503

FM-3

FM-2

FM-1

20"X60"X20" HIGH8

20"X24"X20" HIGH 8

RISER VALVE TREE IS

ABOVE TRENCH LID

20"X20"X18" HIGH 10

C2

MW301

8 10

8 10

SP-2

1-1/2"

C1

MW301

HEAT TRACE PANEL

FLOW METER PANEL

ISOLATION VALVE12

ISOLATION

VALVE 12

telephone: 206.448.1911

2301 Fifth Avenue, Suite 401 www.notkin.com facsimile: 206.448.9485

Seattle, WA 98121

Contact: Peter Sloane, P.E.

notkin#: 217069 mechanical engineers notkin

SCALE:

EPROJECT NO.:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

SHEET OF

DRAWFORM REVISION: 31 JANUARY 2017

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

AS NOTED

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

N A

V F

A C

N W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S

IL

V E

R D

A L

E W

A S

H

IN

G T

O N

N A

V A

L B

A S

E K

IT

S

A P

-B A

N G

O R

S

IL

V E

R D

A L E

W

A S

H

IN

G T

O N

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

S

YM

D

ES

C R

IP

TI

O N

D A

TE

A P P R

FIRE PROTECTION

D. GIBSON/T. BOLING

1389895

K. PAULSON

/2 /2

:2

:3

P M

C R e v it P ro je c ts

\P -9

\P

-P

IE

R

-1

-M

E C

H -R d e ta c h e d

.r v t

F Y

M

C O

N P

R O

J E

C T

P -9

T P

P P

IE

R

A N

D M

A

IN

T E

N A

N C

E F

A C

IL

IT

Y

T P

P T

R E

S T

LE

A

N D

P

IE

R P

LA

N

A

R E

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

N O

R T

H W

E S

T

KHRPS LDS

MW102

192 269

16046540

B. GALLOWAY

B. NIXON

SCALE: 1/8" = 1'-0"

TPP TRESTLE AND PIER PLAN - AREA 2

NA1 0' 4' 8' 16'

SHEET KEYNOTES:

PROVIDE HEAT TRACE JUNCTION BOX AT BASE

OF RISER FOR POWER CONNECTION TO RISER

HEAT TRACE SYSTEM.

PROVIDE 1" INSULATION & T316 SST WEATHER

JACKETON PW PIPE AND FITTINGS IN

TRENCHES.

PROVIDE 1/2" INSULATION & T316 SST WEATHER

JACKET ON OW AND SS PIPE, FITTINGS, AND

VALVES IN TRENCHES.

THE PIPES ELBOW DOWNWARD (IN THE

DIRECTION NORTHWARD TOWARDS THE PIER

SHIP UTILITY CONNECTIONS)

SUMP PUMP TIES INTO THE SANITARY SEWER

MAIN THROUGH A 1.5" CHECK VALVE, BALL

VALVE, AND PIPE. SEE DETAIL A3/MW502.

PW RISER NO. 1 (SOUTH END)

PROVIDE FLOW METER WITH FLANGED

ISOLATION VALVE UPSTREAM AND

DOWNSTREAM.

PROVIDE ALL T316 SST 14 GA CONTAINMENT

BOX WITH GASKETED LID FLASHED AND

LATCHED TO PREVENT WATER INTRUSION.

PROVIDE 1/2" THICK FLEXIBLE ELASTOMERIC

CELLULAR INSULATION ON OUTSIDE OF

CONTAINMENT BOX. PROVIDE ENTRY BOOT AT

ALL WALL PENETRATIONS TO ACCOMODATE

DOUBLE WALL PIPE TO SINGLE WALL PIPE

INSIDE BOX, OR LEAK DETECTION CABLES, OR

CONTROL CABLES. SEE DETAIL C1 / MW412.

PROVIDE 316 SST NEMA 4X ENCLOSURE

(36"WX36"HX12" DEEP) MOUNTED UTILIZING SST

CHANNEL STRUT UP 36" ABOVE DECK TO

HOUSE (3) REMOTE TRANSMITTERS FOR FM-1,

FM-2, AND FM-3. SEE ELECTRICAL EW112 FOR

CONNECTION TO AMI MONITORING SYSTEM AND

CONDUIT ROUTING.

PROVIDE SINGLE POINT DISTINGUISHING LEAK

SENSOR IN EACH CONTAINMENT BOX ON PIER,

TRESTLE, AND ABUTMENT UTILITY VAULT, AND

CONNECTION CABLES IN CONDUIT FROM

SENSORS TO LEAK DETECTION MONITORING /

ALARM PANEL LDS-3 (SEE MW101 FOR

LOCATION).

PROVIDE 316 SST NEMA 4X ENCLOSURE

(36"WX36"HX12" DEEP) MOUNTED UTILIZING SST

CHANNEL STRUT UP 36" ABOVE DECK TO

HOUSE HEAT TRACE CONTROLS. PROVIDE

HEAT TRACE MULTIPOINT CONTROL AND

MONITORING SYSTEM PANEL (208/120 VOLT, 1

PHASE) INCLUDING COMMON HEAT TRACE

FAILURE ALARM AT LOCAL PANEL AND AT B1305

BASE MONITORING SYSTEM. SEE ELECTRICAL

EW112 AND EW113 FOR CONDUIT AND CABLE

ROUTING FROM HEAT TRACE PANEL. PROVIDE

WARNING SIGN ON FACE OF THE HEAT TRACE

ENCLOSURE WHICH READS: "HEAT TAPE

SYSTEM (SELF LIMITING). DO NOT DISCONNECT

POWER."

PROVIDE FLOW METER FM-1 WITH FLANGED

ISOLATION VALVES UPSTREAM AND

DOWNSTREAM WITH MINIMUM DISTANCE PER

METER SENSOR REQUIREMENTS. PROVIDE

1-1/2" THICK REMOVABLE INSULATION PAD

OVER METER FM-1 SENSOR AND VALVES.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

SCALE: NONE

KEY PLAN

GENERAL NOTES:

PIPING SHOWN IS IN TRENCHES BELOW

THE DECK ACCESS LIDS UNLESS

NOTED OTHERWISE.

1.

P

PI

0/

A

JM

Sheets
MW102 - TPP TRESTLE AND PIER PLAN - AREA 2

File details come from the government source that posted it. Updated .