About this file

This document is a mechanical return/exhaust duct plan (M104) for the Design Wing Relocation in Building 1005 at a Marine Corps Base. The detailed architectural drawing shows a comprehensive mechanical system layout with multiple duct sizes ranging from 14"x14" to 32"x36", indicating a complex HVAC infrastructure design. The technical drawing includes specific notes about mechanical system requirements, such as duct location, sizing, and installation guidelines. The plan appears to be part of a construction document set for a Marine Corps facility renovation or new construction project, specifically focused on the mechanical ventilation system's routing and configuration across different rooms and spaces within the building.

View the file

Other files

File Type Posted
N4008524R2785 Amendment 0008.pdf PDF
N4008524R2785 Amendment 0007.pdf PDF
M101_rev 2.pdf PDF
N4008524R2785 Amendment 0006.pdf PDF
VMR- uncapped.jpg JPG image
E-101.pdf PDF
E-105.pdf PDF
M103.pdf PDF
M602.pdf PDF
23 73 33_Amendment 2.pdf PDF
E-103.pdf PDF
E-104.pdf PDF
E-107.pdf PDF
M601.pdf PDF
VMR- capped.jpg JPG image
T-1.pdf PDF
25 05 11.00.pdf PDF
A-105.pdf PDF
A-501.pdf PDF
E-102.pdf PDF
M501.pdf PDF
N4008524R2785 Amendment 0005.pdf PDF
23 09 00.pdf PDF
23 09 23.13 20 Attachment 4.pdf PDF
01 32 16.00 20.pdf PDF
22 00 00.pdf PDF
23 09 23.13 20 Attachment 2.pdf PDF
23 09 13.pdf PDF
23 09 23.02.pdf PDF
Attachment N - Revised Eletrical-Telecomm Sheets.pdf PDF
Attachment O - Revised Specs pg3.pdf PDF
Attachment M - Specifications TOC.pdf PDF
N4008524R2785 Amendment 0003.pdf PDF
Attachment P - Site Visit Log.pdf PDF
N4008524R2785 Amendment 0002.pdf PDF
Attachment I - Site Visit Information REVISED.pdf PDF
Attachment I - Site Visit Information.pdf PDF
Attachment J - Site Visit Participant Log.xlsx XLSX spreadsheet
Attachment L - Electrical Room.pdf PDF
N4008524R2785 Amendment 0001.pdf PDF
Attachment K - Asbestos Inspection Report.pdf PDF
Attachment A - PPI LOG TEMPLATE.xlsx XLSX spreadsheet
Attachment B - CONSTRUCTION AND DESIGN EXPERIENCE PROJECT DATA.docx DOCX document
Attachment E - B1005 Drawings.pdf PDF
Attachment F - B1005 Specifications.pdf PDF
Attachment H - PIEE VENDOR ACCESS INSTRUCTIONS.pdf PDF
N4008524R2785 Small Business Marine Corps MACC for General Construction.pdf PDF
Attachment C- PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
Attachment D - B1005 Price Proposal Form.docx DOCX document
Attachment G - B1005 Statement of Work.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

300 302

"x

20"x20"

28"x28"

"x

"x

22"x22"

"x

DESIGN WING RELOCATION

BUILDING 1005

30"x18"

"x

MECHANICAL RETURN/EXHAUST DUCT PLAN1

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

J F ORR PE

AutoCAD SHX Text

SATISFACTORY TO: DATE

AutoCAD SHX Text

APPROVED: PWO OR OICC DATE

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

C MAAS

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

CONST. CONTR.

AutoCAD SHX Text

MECHANICAL - HVAC RETURN DUCTWORK

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

AutoCAD SHX Text E1

AutoCAD SHX Text

SIZE

AutoCAD SHX Text 80091

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text M104

AutoCAD SHX Text

J BELY

AutoCAD SHX Text

K ROOT

AutoCAD SHX Text 60036677

AutoCAD SHX Text 12'

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text 16'

AutoCAD SHX Text 20'

AutoCAD SHX Text

NA

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text 21-0019

AutoCAD SHX Text

SCALE: NOTED

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text 05-21-0019

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text

AutoCAD SHX Text

%%UNEW WORK GENERAL NOTES:

AutoCAD SHX Text UL LISTED FIRE DAMPERS FOR P533 ASSEMBLY MUST BE PROVIDED AT ALL RETURN AND EXHAUST PENETRATION LOCATIONS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

UH

AutoCAD SHX Text

AutoCAD SHX Text

EF

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AH

AutoCAD SHX Text

AutoCAD SHX Text

SS

AutoCAD SHX Text

SCALE: 3/16" = 1'-0"

AutoCAD SHX Text M104

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text

AMENDMENT 2. CHANGED RETURN SIZES.

AutoCAD SHX Text 03/28/25

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UNEW WORK KEYNOTES:

AutoCAD SHX Text LOUVER TO BE INSTALLED ABOVE DOOR. COORDINATE LOUVER LOCATION WITH DOOR. ANY CHANGES DUE TO DIFFERENCES BETWEEN BASIS OF DESIGN AND CONTRACTOR PROCURED EQUIPMENT MUST BE RESOLVED AT NO ADDITIONAL COST TO THE GOVERNMENT. PROVIDE RH-1 FOR EACH RANGE WITH INLINE FANS AND EXHAUST DUCT TO ROOF. TERMINATE WITH ROOF CAP WITH BACKDRAFT DAMPER. EACH VENT HOOD SHALL HAVE ITS OWN DEDICATED EXHAUST DUCT AND ROOF CAP. COMBINING EXHAUST DUCTS IS NOT PERMITTED. BALANCE EXISTING RETURN GRILLE TO 600 CFM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text